GROWATT 1122AS-S-V1 3 Phase AC Charger Installation Guide

June 13, 2024
Growatt

1122AS-S-V1 3 Phase AC Charger
Installation Guide THOR 11/22AS-S-V1
3-phase AC charger Quick installation guide

1122AS-S-V1 3 Phase AC Charger

Disclaimer
This user manual is copyrighted by Shenzhen Growth New Energy Co. ,ltd.(Hereinafter referred to as “Growth”) No company or person may extract or copy part or all of this user manual without the written permission of Growth. Content must not be transmitted in any form, including materials and publications. All rights reserved. Growth has the final right to interpret this user manual. The information in this manual is subject to change without notice.
Thank you for using Growth THOR EV chargers equipment!
THOR series intelligent three-phase AC charger is a power supply device that uses professional and advanced technology to provide energy supply to electric vehicles, it also has friendly man-machine
interface and versatile functions of control, billing, and communication.
The charger can be connected to a back-office server to realize the functions of reservation and payment via Mobile phone APP. Diversified communication options, including wired Ethernet, WIFI, 4G is available for back-office server connection.

Product description

GROWATT 1122AS-S-V1 3 Phase AC Charger - Description

  1. LOGO and status indicator
  2. LCD display
  3. RFID ready
  4. Start or stop button
  5. Socket outlet(plug holder for cabled version)
  6. Mounting bracket
  7. Side window and nameplate
  8. Waterproof cable gland for AC input cables
  9. Waterproof cable gland for communication wires

Wiring definition in the side window

GROWATT 1122AS-S-V1 3 Phase AC Charger - Figure 1

  1. Terminal block for CT/meter wiring. The terminal definition is: 485A/485B is RS485 terminal for meter connection; la+/la-, Ib+/lb-, Ic+/lc- is for CT connection
  2. AC input terminals. Terminal definition is: L 1/L2/L3/N/PE
  3. Peak&Off Peak Charging Enable signal is: sense UN

Packaging list

No. Name Qty Remark
1 Charger 1
2 User manual 1
3 Quality certificate 1
4 Mounting bracket 1
5 Cable hook 1 For cabled version
6 ST6.3X40 Stainless steel hex-head self-drilling screws 4-7 4 for socket

version, 7 for cabled version(3 of the 7 screws is for cable hook fixing)
7| 12X46 Plastic expansion plugs| 4-7| 4 for socket version, 7 for cabled version(3 of the 7 plugs is for cable hook fixing)
8| User card| 1| RFID function will be equipped with user card

Installation and wiring

3.1 Mount on a wall
3.1.1 Open the packaging, you’ll see a EV charger, a mounting bracket, a user manual and a bag of mounting accessories. There is also an RFID card if the EV charger is RFID version. For cabled version, a cable hooker is also included inside.

3.1.2 Remove the mounting bracket from the EV charger, use it as a template to mark the position of the drill holes. Drill the holes and hammer the expansion bolts in the accessories bag into the holes. Then fix the mounting bracket onto the wall.

3.1.3 Put the EV charger onto the bracket, and fix it with the 2 screws at the bottom of the EV charger. The installation is done.

3.1.4 Crimp the below shown insulated ferrule or ring terminals on the end of the AC input wires. Connect the wires into the terminal block of the EV charger as below. Close the side window with the cover, then the wiring is done. GROWATT 1122AS-S-V1 3 Phase AC Charger - Figure
5

3.2 Mount on a pole
3.2.1 Open the packaging of the pole, take out the pole and mounting accessories.

GROWATT 1122AS-S-V1 3 Phase AC Charger - Figure 6

3.2.2 The pole must be installed on a hard surface, concrete surface is recommended, it can also be mounted on a solid ground. Drill holes according to the requirements marked on the illustration for fixing expansion bolts.

3.2.3 Fix the pole onto the holes with expansion bolts. The input cables shall go into the pole from the bottom middle area and come out of it from the area below the cable hooker.

3.2.4 Fix the mounting bracket onto the pole.
3.2.5 Position the EV charger onto the bracket and secure it on the bracket with the 2 screws. GROWATT 1122AS-S-V1 3 Phase AC Charger - Figure
9

3.2.6 Crimp the below shown insulated ferrule or ring terminals on the end of the AC input wires. Connect the wires into the terminal block of the EV charger as below. Close the side window with the cover, then the wiring is done. GROWATT 1122AS-S-V1 3 Phase AC Charger - Figure
10

 APP download, register, and login

4.1 APP download.

http://server-cn.growCatt.com/app/xml/download_cn.png.jsp

Users can scan the QR code (Android and I0S) with the WeChat, or go to the App Store and Google Play to search for Shine Phone or log in to our monitoring website server.growatt.com or server-cn.growatt.com to download.
4.2 Register
Before using Shine Phone APP the first time, the user must register an account in advance.
There are two steps when users register the account:
(1) Fill in the account registration informationGROWATT 1122AS-S-V1 3 Phase
AC Charger - Figure 11

a) Fill in the account information. To fill in the account information, you need to select the account country (required), fill in the user name (required), password (required), confirm password (required), telephone (required in China,  optional for other regions), email (optional in China, required for other regions), installer code(optional).
b) The user terms must be checked manually to agree before registering, all required fields must be filled in before registering.
(2) Add Plant GROWATT 1122AS-S-V1 3 Phase AC Charger - Figure
12

a) When customers add plant, they need to fill in the name of the plant (required), installation date (required), national city (required), detailed address (optional), time zone (required), PV capacity (required), plant type (required,  Household plant/ /Commercial plant/Ground plant), fund income (optional), plant picture (optional, when the user does not upload pictures, a default plant picture will be given).
b) There are two ways to fill in the plant address, automatic acquisition, and manual input. Automatic acquisition, through satellite positioning, obtain the current location of the user, then the detailed location will be filled automatically  of the country .Manual input, the user manually input the country, city and detailed address.
c) This page can be skipped. After skipping, the user registration account will be longlined directly, enter the APP plant page. Skipping the process of adding plant, the default plant will not be generated. When enter the APP plant page, the  system will remind the user to add the plant.

4.3 Sign in and log out

GROWATT 1122AS-S-V1 3 Phase AC Charger - Figure 13

The user can log in the APP through the existing account and password. The system automatically determines the account’s attributes and distributes the server. The Shine Phone system is divided into China and Worldwide servers. After  the users log in successfully, for the next time log in, you can directly select the account number from the information the phone remembered.

EV Charger Internet Configuration

For new users, please click the “+” in the upper right corner of the overview, select “GroHome” and add device (EV Charger), for users who already have had “GroHome” page, go to the “GroHome” page directly and click the “+” in the
upper right corner to add device (EV Charger) GROWATT 1122AS-S-V1 3 Phase AC
Charger - Figure 14If the users haven’t build the “power plant” before and click “add device”, the app will remind you to add a plant firstly, and the app will allow to “add device” after finishing filling the information of the plant. GROWATT 1122AS-S-V1 3 Phase AC Charger -
Figure 15

5.1 WiFi Configuration
a) Choose a related power plant after adding the device (Note: a power plant is required to build before adding the EV Charger)
b) Enter the serial number of the EV charger or scan the Bar/QR code to add the EV charger
c) Select “WiFi” for network configuration
d) Enable the “WLAN” in the setting and connect to the “WIFI” whose name is consistent with the serial number of the EV charger, then enter the WiFi password (default WiFi password is: 12345678) and click “next”
e) Enter the WiFi name and password of your router (the connected WiFi is required2.4GHz WiFi, and the network should be available), and then click “Next”
f) Please wait 2-5 minutes and refresh the EV charger status to confirm whether the communication is successful
Note: If the EV charger has been configured before, then don’t need to configure the network again. GROWATT 1122AS-S-V1 3 Phase AC Charger - Figure
16GROWATT 1122AS-S-V1 3 Phase AC Charger -
Figure 17

Advanced Setting
If the EV charger has an external current sensing device, then click the “advanced “in the WiFi configuration page, and choose the corresponding configuration (CT or meter type, choose the right brand of the meter type, Acre I or Easton) GROWATT 1122AS-S-V1 3 Phase AC Charger - Figure
185.2 Network Cable Connection Configuration
a) Choose a related power plant after adding the device (Note: a power plant is required to build before adding the EV Charger
b) Enter the serial number of the EV charger or scan the Bar/QR code to add the EV charger
c) Select “Network Cable” for network configuration
d) Click “cancel” and the network will be connected dynamically based on the dynamic IP mode.
e)Waiting for 2-5 minutes which EV charger will refresh its status, and confirm whether the communication is successful GROWATT 1122AS-S-V1 3 Phase
AC Charger - Figure 19

Note: If the users want to set the static IP mode

  1. Click “go to set” during (d) step and make sure the network cable is disconnected
  2. Do the hotspot connection, connect to the WiFi whose name is consistent with the series number of EV charger, and enter the default password:12345678
  3. Make sure the parameters of IP and gateway are the same as that of the router and click “next”
  4. Connect the network cable and wait for 2-5 minutes which EV charger will refresh its status, and confirm whether the communication is successful

GROWATT 1122AS-S-V1 3 Phase AC Charger - Figure 20

5.3 4G Configuration
If the EV charger is a 4G model, then the user can click the “skip” directly during the page of network configuration methods. GROWATT 1122AS-S-V1 3
Phase AC Charger - Figure 21

5.4 AP Mode Configuration
If the network connection is abnormal, the users can use the AP mode to reset the network or do some basic setting
a)Click the AP mode, and enter the hotspot connection, click “next” to switch to other pairing mode.
b)Connect the WiFi whose name is consistent with the series number of the EV charger and click next
c)User can check the basic information, and do some basic parameters setting like network setting, server setting and EV charger setting
d)After that, waiting for 2-5 minutes which the EV charger wit I refresh its status GROWATT 1122AS-S-V1 3 Phase AC Charger - Figure
22

Note: Network setting; connect to wifi;
The wifi name and wifi password should be entered manually .Before entering the wifi name or wifi password ,users should enter ‘000000’ first and choose the item again to input the name or password of the wifi.

Operation instruction and LCD description

6.1 Charging mode and Operation
User can go to the “setting” page and click the Charger setting”, to set the charging activation way like APP, RFID, plug and charge GROWATT 1122AS-S-V1
3 Phase AC Charger - Figure 23

APP mode:
Initiate or cease charging by using APP. You can also use APP for reservations and choose the work mode you need. GROWATT 1122AS-S-V1 3 Phase AC Charger -
Figure 24

APP mode operation process flow

RFID mode:
Charging can only be initiated or ceased by swiping RFID card.

GROWATT 1122AS-S-V1 3 Phase AC Charger - Figure 25RFID mode operation process flow

Plug& Charge:
Charging will start automatically after EV plugged in. If you want to stop the charging, just press the forced on/off button on the side of the charger.

GROWATT 1122AS-S-V1 3 Phase AC Charger - Figure 26

Plug&Charge mode operation process flow

6.2 LCD interface introduction

GROWATT 1122AS-S-V1 3 Phase AC Charger - Figure 27GROWATT 1122AS-S-V1 3 Phase AC Charger - Figure
28

EV Charger Work Modes

7.1 Fast Mode
Plug & Charge
Click “charge” directly and the EV will be charged at maximum power coming from a renewable energy source or simply from the grid, especially quick if you’re in a hurry, and support multiple control strategies of timer, charging capacity, charging budget.
Note: the reservation function can only be set when the EV charger is in idle status

Time Reservation
It can be divided into charging time and charging period reservation, users can set when it will start to charge and how long the charging will continue, also can enable “every day” to make it work following that strategy to work all the time

GROWATT 1122AS-S-V1 3 Phase AC Charger - Figure .30

Charging Capacity Reservation
Users can set the target charging capacity(kWh) and the start time through clicking “energy, and also can enable “every day” to make it to work following that strategy to work all the time GROWATT 1122AS-S-V1 3 Phase AC Charger -
Figure 30

Charging Budget Reservation
Users can set the target charging budget and the start time through clicking the “cost”, and also can enable “every day” to make it to work following that strategy to work all the time GROWATT 1122AS-S-V1 3 Phase AC Charger -
Figure 31

7.2 PV Linkage Mode
Introduction
Driven by solar, charge your car with renewable energy, the EV will be charged by the surplus solar power dynamically, combining PV and EV charger together to maximize the solar self-consumption rate and cut your bill.
Note: Under the PV-Linkage mode, the EV charger will automatically start charging when the surplus solar power is sufficient.

Wiring
To monitor the real-time power import and export from the grid, a CT or meter is required for this function to work properly
If CT is used, the wiring will be as below

GROWATT 1122AS-S-V1 3 Phase AC Charger - Figure 33

APP Operation
The PV linkage mode require the EV charger to connect with an external current sensing device, and choose the corresponding configuration (CT or meter type, choose the right brand of the meter type, Acral or Eastron)

Note: Users can choose different meters to monitor the real-time power import and export from the grid. For single-phase grid Acral DDS1352,Eastron SDM230 or Eastron SDM120 MID is feasible. For three-phase grid Acral DTSD1352, Eastron SDM630, Eastron SDM72O MID or Din-rail OT SU666 MID is feasible.
Function of importing from the grid
Disable the function of importing power from the grid
The EV will be charged dynamically only by surplus solar power when the surplus solar power is greater than Min. operation power*. When surplus solar power is lower than Min. operation power, then the EV charger will stop charging.

Enabling this function will allow the EV charger to take power from the grid. During the solar power insufficient period, the EV charger will operate according to the default minimum charging power. For single phase EV charger the default value is 1.4kW.As for three phase EV charger, it’s 4.1kW.Once allowing the power take from the grid and set P(kW)value. For single-phase, P<1.4kW; For three-phase, P<4.1kW; When the excess solar power is greater than (1.4-P)kW or (4.1-P)kW value, the charger will start and charge at the power of 1.4kW or 4.1kW; For single-phase P> 1.4kW; For three-phase P> 4.1kW;the charger will start directly and charge at the power of P(kW),If the excess solar power is greater than P value, the charging power will follow the excess solar power. Note: *Min. operation power: 1.4kW for single phase EV charger, and 4.1kW for three-phase EV Charger
Boost Function
‘Manual Boost Function
It is useful if users arrive home with an almost empty battery and users want to charge the EV quickly to ensure enough energy for a short trip when the solar energy is insufficient. While users enable the manual boost function and set “start time” and “end time”, the EV charger will charge the EV at its max. power during a set period even drawing the power from the grid, after that, it will recover back to the normal PV linkage mode. GROWATT 1122AS-S-V1 3 Phase
AC Charger - Figure 36

·Smart Boost Function
It’s useful to guarantees EV’s battery capacity before a set time when the solar energy is insufficient.
While users enable the smart boost function and set “Pick-up time” and “Preset electricity”, the EV charger will charge the EV with a target kWh figured by a set time, it may draw the power from the grid to guarantee the EV’s battery capacity when the solar energy is insufficient.
Example: if the users enable smart boost and set the “pick-up time” is 22:00, and “preset electricity” is 20kWh.
In sunlight hours, the EV has been charged by surplus solar energy with the only 10kWh of charge accumulated, because users activated the smart boost, then the THOR EV Charger will automatically boost the charge to the required 20kWh by 22:00 even taking power from the grid.

7 .3 Off-peak modes
Introduction
Once enable the Off-Peak mode, the EV charger will automatically charge the EV when it’s at off-peak time to reduce the electricity bill. Users also can customize their low-rate charging time in the off-peak mode page Note: Users need to  input the charging rates in the setting page manually before enabling off-peak modes
Note: Under the Off-peak mode, the EV charger will automatically start charging at the low-rate charging time. GROWATT 1122AS-S-V1 3 Phase AC
Charger - Figure 38

Smart Boost Function
It’s useful to guarantees EV’s battery capacity before a set time when the off-peak time is not long enough.
While users enable the smart boost function and set “pick-up time” and “preset electricity”, the EV charger will charge the EV with a target kWh figured by a set time, it may draw the power from the grid to guarantee the EV’s battery capacity when the off-peak time is not long enough.GROWATT 1122AS-S-V1 3
Phase AC Charger - Figure 39

7 .4 Load balancing function
The EV charger can read the incoming power to the house with an additional CT/Meter. Then the EV charger will adjust its charging power dynamically according to the home power to avoid exceeding the limited point, always charge
your car at the maximum charging speed without triggering the power limitation.
Note: The load balancing function require an external CT/Meter, and please follow the wiring method of PV linkage mode. GROWATT 1122AS-S-V1 3
Phase AC Charger - Figure 40

Other Settings

The setting page includes basic information, network setting, pile setting, load balancing and authorization management. Basic information: EV charger ID, EV charger name, country and city, version number.

Network setting: network connection method, network mode setting, gateway settings, subnet mask, DNS address

Charger setting:

  1. Charging activation: users can set the charging activation way like APP, RFID, plug and charge
  2. Charging rates: users can set their charging fees, which could be used for the calculation of electricity cost and off-peak mode.
  3. Currency: Users can set the currency to calculate the budget etc.
  4. Allow charging time: user can use it to limit the time to use the EV charger.
  5. Maximum output current of the EV charger: users can use it to limit the max. power output from the EV charger.
  6. Warm up function: ln the case of extremely cold weather, the EV mostly needs to preheat and defrost after starting. Once the warm-up function is enabled, when the EV is fully charged, the EV charger will preheat the EV, which can  reduce battery consumption.
  7. LCD: users can disable or enable the LCD.
  8. External current sampling wiring method: When CT meter is used, the external current sampling wiring method should be CT2000 or CT3000.When direct connection meter is used, the external current sampling wiring method is METER.

Authorization management:
Permissions: it’s useful for authorization management, add and authorize the other account which can use the EV Charger directly GROWATT 1122AS-S-V1 3
Phase AC Charger - Figure 45

·Version upgrade
Users can check the latest version of the inverter’s firmware and the current version they are used now. If there is new version, users can upgrade by clicking the ‘Upgrade’.

Record

a)Charging record:
Display the serial number of the EV charger, number of the charging gun, start time, end time, charging time, charging cost, charging capacity, and self­ consumption rate b )Appointment record:
Display the list of charging schedules that have been set before.

Data
The users can read the total charge capacity(kWh) and cost, also the self­ consumption energy and rate by day, month, and year.

Configuration through internal web (Service Tool )

After the installation and wiring is done, connect the Charger to a computer and configure parameters via the web browser of the computer, then the Charger can be ready for use.
11.1 Set computer’s IP
The Charger’s default IP address is 192.168.1.5. To access the parameter setting interface, you’ll need to first set the computer’s IP to 192.168.1.x(x can be any value between 1 and 255 except for 5, e.g. 192.168.1. 10).
To set a static IP on your Windows computer:

  1. Click Start Menu > Control Panel > Network and Sharing Center. (For Windows 8 and higher, search for and open Control Panel and select Network and Internet).
  2. Click Change adapter settings.GROWATT 1122AS-S-V1 3 Phase AC Charger - Figure50
  3. Right-click on Local Area Connection and click on Properties.GROWATT 1122AS-S-V1 3 Phase AC Charger - Figure51
  4. Select Internet Protocol Version 4 (TCP/IPv4) and click on Properties.
  5. Select “Use the following IP address” and enter the IP address, Subnet Mask, Default Gateway. Click OK and close the Local Area Connection properties window.

11.2 Configure parameters
Connect the charger to a computer via a network cable. Open the web browser and type in http://192.168.1.5:8080/ in the address field and click enter, then the parameter setting  page of the charger will be opened up. Parameter setting  can only be done via web browser on a computer. It is suggested to use IE or Firefox, other browser might have compatibility problem.
GROWATT 1122AS-S-V1 3 Phase AC Charger - Figure54GROWATT 1122AS-S-V1 3 Phase AC Charger -
Figure55

Explanation of parameters:

  1. Firmware version of the Charger. This item cannot be modified here on the setting page.GROWATT 1122AS-S-V1 3 Phase AC Charger - Figure56

  2. Charger ID, this is the unique identification of the Charger. If the charger is to be connected to Grewal! back-office server, this ID must be set as the serial number on the nameplate of the Charger. Otherwise the Charger cannot be registered on the server.GROWATT 1122AS-S-V1 3 Phase AC Charger - Figure57

  3. Charger IP. The default IP is 192.168.1.5. It is not suggested to change the default IP.
    If you have changed the default IP and forgot the new IP, you can reset the charger to factory setting by long press the reset button(the reset button on control board, not the red emergency stop button) until the charger reboot. Then you can use the default 192.168.1.5 for access.
    Please note: After restoring the charger to factory setting, you’ll need to reset the charger ID(same as serial number, can be found on the nameplate sticker) and server url, otherwise the charger won’t be connected to the back- office server.GROWATT 1122AS-S-V1 3 Phase AC Charger -
Figure58

  4. Charger gateway. The default value is 192.168.1.1. It is not suggested to change. If the gateway has been reset to other value and you have forgotten the new value, you can restore the charger to factory setting by long press the reset button.GROWATT 1122AS-S-V1 3 Phase AC Charger - Figure59

  5. Charger Subnet mask. The default value is 255.255 255.0. It is not suggested to change. If the subnet mask has been reset to other value and you have forgotten the new value, you can restore the charger to factory setting by long press the reset button.GROWATT 1122AS-S-V1 3 Phase AC Charger - Figure 60

  6. MAC address. This is the MAC address used for LAN cable connection. If the charger is connected to Growth back-office server via LAN cable and the router has MAC access control, then you can put this MAC in the router to allow the charger to access serverGROWATT 1122AS-S-V1 3 Phase AC Charger - Figure 61

  7. Server URL is to set the domain name or IP address of the back office server to be connected.
    The domain name of Grewal! server is “Ws:/fevcharge Growatt.com:8080/ocpp/Ws”; IP address is ws://192.168.1.5.8080/0cpp/ws”. Authentication Key and Heartbeat Interval is used for testing and no need to reset.GROWATT 1122AS-S-V1 3
Phase AC Charger - Figure62

  8. Charging fee per unit of electricity.GROWATT 1122AS-S-V1 3 Phase AC Charger - Figure 63

  9. PIN of the charger, used to verify the PIN of user card, To use a RFID card with the charger, their PIN must be consistent. If the user card has a different PIN, then it cannot be used on this charger. The default PIN setting of the charger is 242007.GROWATT 1122AS-S-V1 3 Phase AC Charger - Figure 64

  10. Peak time period. Set the time period of peak tariff.GROWATT 1122AS-S-V1 3 Phase AC Charger - Figure 65

  11. Off-peak time period. Set the time period of off-peak tariff.GROWATT 1122AS-S-V1 3 Phase AC Charger - Figure 66

  12. Time of the charger. Set according to the local time. After the charger is connected to back-office server, the time will be synchronized with the server’s time. If the charger has no server connection, then you’ll have to reset the time  every time you turn off and back on the charger.GROWATT 1122AS-S-V1 3 Phase AC Charger - Figure 67

  13. Language of LCD screenGROWATT 1122AS-S-V1 3 Phase AC Charger - Figure 68

  14. Charger DNS setting, this only needs setting when the charger is to connect to server via LAN cable.GROWATT 1122AS-S-V1 3 Phase AC Charger - Figure 69

  15. Set the max output of the charger.GROWATT 1122AS-S-V1 3 Phase AC Charger - Figure 70

  16. Charging mode setting. 1: APP/RFID mode; 2: RFID mode; 3: Plug&Charge mode.GROWATT 1122AS-S-V1 3 Phase AC Charger - Figure 71

    1. WiFi SSID(wireless network name) and WiFi Key(WiFi password) is used for WiFi connection.GROWATT 1122AS-S-V1 3 Phase AC Charger - Figure 72
    1. Set peak tariff and off-peak tariff.GROWATT 1122AS-S-V1 3 Phase AC Charger - Figure 73
  17. (32)

  18. Max power import to the property, Power sampling device selection, meter value collection interval. These 3 parameters are used for power management setting.GROWATT 1122AS-S-V1 3 Phase AC Charger - Figure 74

  19. Over temperature protection value, not suggested to change.GROWATT 1122AS-S-V1 3 Phase AC Charger - Figure 75

  20. Charging-allowed time. Charging can only start within this time period. This is used for off-peak charging setting.
    If you want to charge out of this period, just press the forced on/off button at the side of the charger.GROWATT 1122AS-S-V1 3 Phase AC Charger - Figure
75

  21. DC residual current sampling value calibration. Enter O and press “Set and Reboot” to calibrate the DC RCD ring.GROWATT 1122AS-S-V1 3 Phase AC Charger - Figure 77

  22. (34) Bluetooth setting. Only needs setting when the charger is equipped with Bluetooth.GROWATT 1122AS-S-V1 3 Phase AC Charger - Figure 78

  23. (28) (35) 4G connection setting.GROWATT 1122AS-S-V1 3 Phase AC Charger - Figure 79

  24. This is for communication testing, no need to reset.GROWATT 1122AS-S-V1 3 Phase AC Charger - Figure 80

  25. DC residual current real-time detection value.GROWATT 1122AS-S-V1 3 Phase AC Charger - Figure 81

  26. Press this button for the parameter change to take effect.GROWATT 1122AS-S-V1 3 Phase AC Charger - Figure 82

  27. This is used to upgrade firmware.GROWATT 1122AS-S-V1 3 Phase AC Charger - Figure 83

There are 2 ways to update firmware for EV charger

  1. Update by SD card
  2. Update on parameter setting page

11.3 Update by SD card
The firmware file must be named as “App.bin”.

  1. Prepare a microSD card with capacity not greater than 4G. Format the SD card using FAT32.GROWATT 1122AS-S-V1 3 Phase AC Charger - Figure 84
  2. In the root directory of the SD card, rename the firmware file as “App.bin”. And create a txt file with name of “UploadConfig.t”.GROWATT 1122AS-S-V1 3 Phase AC Charger - Figure 85
  3. Open the txt file, write “state=1” in it and save the file.GROWATT 1122AS-S-V1 3 Phase AC Charger - Figure 86
  4. Insert the SD card into the charger, turn off and back on the charger, the update will start automatically. The indicator will first flash red and then flash green with a long beep as the end of the update(sometimes the beep sound may  not be clearly heard). After the update is done, turn off the charger and remove the SD card.GROWATT 1122AS-S-V1 3 Phase AC Charger - Figure 87
  5. Check the current FW version on LCD or the parameter setting page.
    To check FW version on the paramete setting page
    Connect the charger to computer via a network cable, the computer’s IP must be within the 192.168.1.x segment(x is any value between 1 and 255 except 5).Open the web browser, type in the charger’s default IP of “http:l/192.168.1.5:8080” and click enter, then you can check the firmware version on the appeared parameter setting page.

GROWATT 1122AS-S-V1 3 Phase AC Charger - Figure 88

11.4 Update on parameter setting page
Using this method for update doesn’t require any specific name for the firmware file.

  1. Connect the charger to a computer with IP address set as 192.168.1.x(x can be any value between 1 and 255 except 5) via a network cable. Open web browser and type in the charger’s default IP address-http:/1192.168.1.5:8080, click  enter then you’ll get into the parameter setting page. GROWATT 1122AS-S-V1 3 Phase AC Charger - Figure 89

  2. Scroll down to the below fieldGROWATT 1122AS-S-V1 3 Phase AC Charger - Figure 90

  3. Click the “Browse” button and select the firmware file. Click “Upload”, then update will start automatically.GROWATT 1122AS-S-V1 3 Phase AC Charger - Figure 91During the update, the LED indicator will behave as below,
    First flash red and goes out with a short beep sound, during this period the firmware file is transmitted to the charger’s flash memory from the computer:
    Then flash red again for some seconds and quickly change to green light flashing. During this period, the charger is updating the firmware to its micro controller.
    When the greenlight goes out, there will be a long beep sound. That means the firmware is successfully updated.
    The beep sound may not be audible with the front cover fixed on the charger.
    If the update doesn’t start after click “Upload”, Turn off and back on the charge to try again.

  4. You might see below content. If the charger is already successfully reboot after the firmware update, close the browser and open it again to check the current firmware version.GROWATT 1122AS-S-V1 3 Phase AC Charger - Figure 92

Troubleshooting

12.1 Troubleshoot by LED behavior or LCD display
If fault occurs, users can check the fault information on the LCD or by the number of blinks of the LED indicator light. Each fault is indicated with a sequence of different numbers of LED blinking. A pause of 3 seconds between each  sequence indicates the beginning or end of a sequence. If multiple faults happen at the same time, each sequence of blinking shows in chronological order at an interval of 3 seconds.
Please see the table below for detail information

No.| Fault code on LCD (if available)| Number of blinks of the LED| Fault description
---|---|---|---
1| 100| 3| The red emergency stop button is pressed or broken
2| 101| 1| Over voltage on phase L3
3| 102| 2| Under voltage on phase L3
4| 103| 1| Over voltage on phase L2
5| 104| 2| Under voltage on phase L2
6| 105| 1| Over voltage on phase Ll
7| 106| 2| Under voltage on phase L1
8| 107| 2| Under voltage on all 3 phases
9| 108| 4| Over current
10| 109| 5| Over temperature
11| 110| 6| RCD leakage Protection
12| 111| 7| 485 Fault
13| 112| | Reserved
14| 114| 10| Relay fault
15| 115| 11| PE fault
16| 116| 12| PEN fault
17| 117| 13| Out of service
18| 118| 14| Door opened

12.2 Firmware update fails
12.2.1 Firmware update failure with SD card:
a. Check if the capacity is over 4G bytes, please use a SD card of less than 4G to retry;
b. Check if the SO card is formatted with FAT32;
c. Check if the firmware file is renamed as App.bin;
d. Check if you have filled in “state=1” in the UploadConfig.txt file.
12.2.2 Firmware update failure with laptop:
Please try with IE browser. Or reboot the laptop to retry.
12.3 WiFi connection & APP issue

a. Please check and input the correct WiFi SSID and password to retry; GROWATT 1122AS-S-V1 3 Phase AC Charger - Figure 94If you check the WiFi setting on the APP, please tum off and back on the charger and connect your mobile to the WiFi emitted by the charger for checking and setting. b. Check if there is access control in the router, e.g. MAC filtering, port blocking, etc.
To verify this, you can use your mobile phone to create a hotspot and try to connect the charger to this mobile hotspot. If charger can connect to the hotspot, but cannot connect to the router, there must be access control in the router,  please check with the site owner for this.
Check if charger is connected on Device list of the hotspot setting page GROWATT 1122AS-S-V1 3 Phase AC Charger - Figure 96d. 1. Some routers have 2 WiFi, one is 2.4GHz, the other is 5GHz. Most homes just use the 5GHz WiFi as their default WiFi. But the charger can only connect to the 2.4GHz WiFi. So if the charger can connect to your mobile phone  hotspot, but cannot connect to the home WiFi. Please check with the home owner or check on their router to see if you are  using the 5GHz WiFi. Please do use the 2.4GHz WiFi for charger connection.
2.When the WiFi signal strength is lower than – 75dbm, the charging point will not be able to connect with WiFi.
(1)Download the WiFi signal strength test tool from the app store to check whether the WiFi signal strength connected to the charging point is greater than – 75dbm.
(2)If the WiFi signal strength is weak, it is recommended to use AP repeater to increase the signal strength, which can enlarge the WiFi signal range. GROWATT 1122AS-S-V1 3 Phase AC Charger - Figure 97

d. Check if the charger is still connected to the computer. Please unplug it from computer otherwise the charger won’t connect to the back-office server.
e. Check if server address is correct in the” Server URL” field. The correct setting is Ws:/less-charge.Growattpower.com:80/ocpp/Ws GROWATT 1122AS-S-V1 3
Phase AC Charger - Figure 98

12.4 Cannot access parameter setting page
a. Check if you have connected the charger to your computer,
b. Check if you have change the computer’s IP to 192.168.1.x(x can be any value between 1 and 255 except 5).
To set a static IP on your Windows computer:
(1). Click Start Menu>Control Panel>Network and Sharing Center. (For Windows 8 and higher, search for and open Control Panel and select Network and Internet).
(2). Click Change adapter settings.

GROWATT 1122AS-S-V1 3 Phase AC Charger - Figure 99(3). Right-click on Local Area Connection and click on Properties.
­GROWATT 1122AS-S-V1 3 Phase AC Charger - Figure100

(4). Select Internet Protocol Version 4 (TCP/IPv4) and click on Properties.

(5). Select “Use the following IP address” and enter the IP address, Subnet Mask, Default Gateway. Click OK and close the Local Area Connection properties window.

c. Check what web browser is being used, it’s suggested to use Firefox or IE, Chrome cannot be used to update firmware.
d. Check if you have input the complete content, which is http://192.168.1.5:8080, in the address field, do not leave out the http://orthe”.8080″.
e. Sometimes you may need to restart the charger to access its parameter setting page.
f. If you have changed the charger’s IP to other value and cannot remember, you can restore the charger to factory setting by long press the reset button. Then you can access it using http://192.168.1.5:8080

Please note: After restoring the charger to factory setting, you’ll need to reset the charger ID and severer, otherwise the charger won’t be connected to the back-office server.

12.5 Charging issue
If charging cannot start after the car is plugged in,
a. Check if the red emergency stop button is pressed.
b. Check what charge mode is being used
APPIRFID: Charge can only be started/stopped by APP or RFID card, and the charger must be connected to the back office server already;
RFID: Charge can only be started/stopped by RFID card;
Plug &Charge: Charge will start automatically when car is plugged in. GROWATT 1122AS-S-V1 3 Phase AC Charger - Figure104

c. Check if off-peak charging is set and if charger’s time is correct.
If off-peak charging is set, charge can only start within the charging allowed time period. GROWATT 1122AS-S-V1 3 Phase AC Charger -
Figure105

Specification

Model THOR 11/22AS-S-V1
Dimension(mm) 240/380/164mm
Weight(kg) <5.5/6.5
Display LCD
Casing Material Stainless steel& Engineering plastics& Acrylic

Input
Voltage| AC 400V
Output
Voltage| AC 400V
Max current| 16/32A
IP Protection degree| IP65
Working environment temperature| -25°C- +50°C
Relative humidity| 5%–95%
Altitude| 2000m
Frequency| 50/60Hz
Communication| Ethernet/WIFI/4G
Charging mode| APP/RFID/Plug and charge
Standby power| <8W
Standard| IEC-62196-2;EN61851
Mounting| Po I e/Wall
Certificate| CE
Protection features
Overvoltage| 450V
Under voltage| 329V
Overcurrent| 18/35.2A
Short-circuit| Yes
Leakage protection| 6mA DC fault current protection
Over temperature| Yes
Lightning protection| Type II

Table 2-1 Product technical specifications

Network standard Wireless standard:IEEE802.11n,IEEE802.11g,IEEE802.11b
Wireless transmission rate 11n: up to 150Mbps

11g: up to 54Mbps
11b: up to 11Mbps
Channel| 2.4g: 1-14
Frequency| 2412-2488MHZ
Transmit power| 12-18DBM
Interface| 2serial port, lush port (host/slave) ,GPIO
Antenna| External/internal antenna
WIFI working mode| Wireless network card/wireless access point
Wireless security| Wireless MAC address filtering
Wireless safety function switch
64/128/152 bit WEP encryption
WPA-PSK/WPA2-PSK,WPANVPA2 security mechanism
Other parameters
Status indicator| Status induction
Environmental standard| Working temperature:-20-85t
Working humidity: 10%-90%RH (Non-condensing)
Storage temp:-40-30t
Storage humidity:5%-90%RH (Non-condensing)
Other performance| Band bandwidth optional:2OMHz,4OMHz

Annex

14.1 Electrical diagram

GROWATT 1122AS-S-V1 3 Phase AC Charger - Figure106

14.2 Contact
Company Name: Shenzhen Growth new energy Co.,Ltd
Address: 4-13F,Building A, Sino-German(Europe) Industrial Park,Hangcheng Ave,Bao’an
District,Shenzhen,China
Website: www.ginverter.com
Service line: +86 755 2998 8492
E-mail: info@ginverter.com

EU Declaration of conformity

This declaration is issued under the sole responsibility of the manufacturer Shenzhen Growth New Energy Co., Ltd. This is to declare that the products listed below have been developed, constructed and manufactured according to the
following EU directives:
• LVD directive 2014/35/EU& EMC directive 2014/30/EU
The applied harmonized standards are shown in the following list

Product Standard

THOR 07 AS-P-V1
THOR 07 AS-S-V1
THOR 11AS-P-V1
THOR 11AS-S-V1
THOR 22AS-P-V1
THOR 22AS-S-V1| EN IEC 61851-1 :2019
EN IEC 61851-1:2O21

https://oss.growatt.com/common/knowledgeShareH5No?lang=cn&type=104

SHENZHEN GROWATT NEW ENERGY CO.,L TD.
4-13F,Building A, Sino-German(Europe)
Industrial Park,Hangcheng Ave,Bao’an
District, Shenzhen, China
T +86 755 27471900
E info@ginverter.com
W www.ginverter.com
Revised date:2022-09-08

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals