VIZULO Crocus LED Luminaire Instruction Manual

June 4, 2024
VIZULO

VIZULO Crocus LED Luminaire Instruction Manual
VIZULO Crocus LED Luminaire

Dimensions

Dimensions

Netto Weight

Netto Weight

The luminaire should be positioned so that prolonged staring into the luminaire at a distance closer than 3.25 m is not expected.

The light source contained in this luminaire shall only be replaced by the manufacturer or his service agent or a similar qualified person.

Caution, risk of electrical shock

Warning iconWARNING!

  • Do not touch LED modules!
  • Do not put any tools or other items on LED modules!
  • In case any LED is physically damaged (example shown below) the warranty is void.
    WARNING
  1. Inductions
  2. Inductions
  3. Inductions

Direction of light for asymmetric lens

Direction
Direction

MCB/Inrush current table

Tridonic LED driver (No dim/ Midnight dimming/ DALI)

Standard/High density| In-rush current (peak/duration)| B10A| B13A| B16A| B20A| B25A| B32A| B40A| C10A| C13A| C16A| C20A| C25A| C32A| C40A
6-12 LED, 8-26W| 15 A (226 μs)| 19| 25| 30| 37| 46| 59| 74| 31| 41| 50| 61| 76| 97| 122
12-20 LED, 20-43W| 25 A (236 μs)| 12| 16| 20| 26| 32| 41| 52| 20| 26| 33| 43| 53| 68| 86
20-28 LED, 30-64W| 32 A (335 µs)| 6| 8| 10| 13| 16| 20| 26| 10| 13| 16| 21| 26| 33| 42
28-48 LED, 45-96W| 42 A (238 µs)| 6| 8| 10| 13| 16| 20| 26| 10| 13| 17| 22| 27| 35| 44
48-64 LED, 70-144W| 65 A (268 µs)| 3| 4| 5| 6| 7| 9| 12| 5| 7| 8| 10| 12| 16| 20
64-108 LED, 100-211W| 80 A (225 µs)| 4| 6| 8| 10| 12| 16| 20| 6| 10| 13| 16| 20| 25| 32
108-128 LED, 135-288W| 130 A (268 µs)| 1| 2| 2| 3| 3| 4| 6| 2| 3| 4| 5| 6| 8| 10
128-160 LED, 200-380W| 160 A (225 µs)| 2| 3| 4| 5| 6| 8| 10| 3| 5| 6| 8| 10| 12| 16

Eco|  | B10A| B13A| B16A| B20A| B25A| B32A| B40A| C10A| C13A| C16A| C20A| C25A| C32A| C40A
4-4 LED, 9-20W| 15 A (226 μs)| 19| 25| 30| 37| 46| 59| 74| 31| 41| 50| 61| 76| 97| 122
4-8 LED, 20-38W| 25 A (236 μs)| 12| 16| 20| 26| 32| 41| 52| 20| 26| 33| 43| 53| 68| 86
8-12 LED, 30-57W| 32 A (335 µs)| 6| 8| 10| 13| 16| 20| 26| 10| 13| 16| 21| 26| 33| 42
12-24 LED, 45-96W| 42 A (238 µs)| 6| 8| 10| 13| 16| 20| 26| 10| 13| 17| 22| 27| 35| 44
24-32 LED, 70-144W| 65 A (268 µs)| 3| 4| 5| 6| 7| 9| 12| 5| 7| 8| 10| 12| 16| 20
32-52 LED, 100-211W| 80 A (225 µs)| 4| 6| 8| 10| 12| 16| 20| 6| 10| 13| 16| 20| 25| 32
52-64 LED, 135-288W| 130 A (268 µs)| 1| 2| 2| 3| 3| 4| 6| 2| 3| 4| 5| 6| 8| 10
64-96 LED, 200-380W| 160 A (225 µs)| 2| 3| 4| 5| 6| 8| 10| 3| 5| 6| 8| 10| 12| 16

Tridonic LED driver (Zhaga)
Standard/High density| In-rush current

(peak/duration)

| B10A| B13A| B16A| B20A| B25A| B32A| B40A| C10A| C13A| C16A| C20A| C25A| C32A| C40A
6-12 LED, 8-26W| 15 A (316 μs)| 16| 21| 25| 33| 41| 52| 66| 26| 35| 41| 55| 68| 88| 110
12-20 LED, 20-43W| 20 A (346 μs)| 11| 14| 17| 22| 27| 35| 44| 18| 23| 28| 36| 45| 57| 72
20-28 LED, 30-64W| 28 A (270 µs)| 10| 13| 16| 20| 25| 32| 40| 16| 21| 26| 33| 41| 52| 66
28-48 LED, 45-96W| 38 A (280 µs)| 6| 8| 10| 13| 16| 20| 26| 10| 13| 16| 21| 26| 33| 42
48-64 LED, 70-144W| 56 A (277 µs)| 3| 4| 5| 6| 7| 9| 12| 5| 6| 8| 10| 12| 16| 20
64-108 LED, 100-211W| 85 A (215 µs)| 3| 4| 5| 6| 7| 9| 12| 5| 6| 8| 10| 12| 16| 20
108-128 LED, 135-288W| 112 A (277 µs)| 1| 2| 2| 3| 3| 4| 6| 2| 3| 4| 5| 6| 8| 10
128-160 LED, 200-380W| 170 A (215 µs)| 1| 2| 2| 3| 3| 4| 6| 2| 3| 4| 5| 6| 8| 10
 |  |  |  |  |  |  |  |  |  |  |  |  |  |  |
Eco|  | B10A| B13A| B16A| B20A| B25A| B32A| B40A| C10A| C13A| C16A| C20A| C25A| C32A| C40A
4-4 LED, 9-20W| 15 A (316 μs)| 16| 21| 25| 33| 41| 52| 66| 26| 35| 41| 55| 68| 88| 110
4-8 LED, 20-39W| 20 A (346 μs)| 11| 14| 17| 22| 27| 35| 44| 18| 23| 28| 36| 45| 57| 72
8-12 LED, 30-57W| 28 A (270 µs)| 10| 13| 16| 20| 25| 32| 40| 16| 21| 26| 33| 41| 52| 66
12-24 LED, 45-96W| 38 A (280 µs)| 6| 8| 10| 13| 16| 20| 26| 10| 13| 16| 21| 26| 33| 42
24-32 LED, 70-144W| 56 A (277 µs)| 3| 4| 5| 6| 7| 9| 12| 5| 6| 8| 10| 12| 16| 20
32-52 LED, 100-211W| 85 A (215 µs)| 3| 4| 5| 6| 7| 9| 12| 5| 6| 8| 10| 12| 16| 20
52-64 LED, 135-288W| 112 A (277 µs)| 1| 2| 2| 3| 3| 4| 6| 2| 3| 4| 5| 6| 8| 10
64-96 LED, 200-380W| 170 A (215 µs)| 1| 2| 2| 3| 3| 4| 6| 2| 3| 4| 5| 6| 8| 10

Energy efficiency class of contained light source(s)

Standard

| CRI
---|---
70| 80| 90
CCT| 1800| F|  |
2200| E|  |
2500| E|  |
2700| D| E| F
3000| D| E| F
4000| C| D| E
5000| C| D| E
5700| C| D| E
6500| C|  | E

Eco

  CRI
70 80
CCT 2200
2700 E
3000 E
4000 D
5000 D
5700 D
6500 D

Terms of use and maintenance

Before luminaire is turned on, it should be mounted according with this mounting instruction or any other applicable regulations.

Mounting instructions

Mounting of luminaire must be performed by a qualied person according with following instructions:

  • The warranty of luminaire does not apply, if the mounting of luminaire has been performed in precipitation (rain, snow, hail).
  • The warranty of luminaire does not apply, if a control system unauthorized by VIZULO or an inapplicable LED driver has been used to drive the luminaire.
  • The warranty of luminaire does not apply, if it has been used in an unsuitable ambient temperature or has been supplied by voltage outside of the specied range.
  • The warranty of luminaire does not apply, if the LED driver program has been changed in any way.
  • The warranty of the luminaire does not apply, if the logged history data of the LED driver has been deleted without the permission of VIZULO.
  • The warranty of luminaire does not apply, if it has been mounted in unspecied angles or upside down (luminaire glass directed up), or it has been completely submerged under water.

Safety instructions

Any actions with the luminaire must be performed by a qualified person, who is certified according with national regulations and requirements.
To prevent any accidents person installing the luminaire must follow national safety requirements and following instructions:

  • The label containing technical parameters of the luminaire has to be studied before the work on it has begun.
  • Any luminaire build or design changes are prohibited.
  • The luminaire must be used in good technical condition and according with this instruction.
  • Only VIZULO authorized spare parts and accessories can be used to repair the luminaire.
  • The repair of luminaire has to be performed by a qualified and certified person.

Maintenance and repair

Luminaire has to be disconnected from electrical grid before it is opened and/or repaired!

  • The person working with the luminaire must follow national regulations and legislations that apply to maintenance and testing of electrical or electronic appliances.
  • The luminaire may need to be cleaned depending on its environment. Only a damp cloth or a sponge may be used to clean the luminaire. Use only household detergents diluted by water.
  • Only VIZULO authorized spare parts may be used for the luminaire.
  • Instruction for changing spare parts must be requested from VIZULO and studied before the repair is attempted.
  • LED modules, lens and LED drivers can be changed on an installed luminaire, but it is advised to perform this task indoor to avoid water entering the luminaire.
  • Spare parts (lens, LED modules and drivers) should be ordered from the information available on the luminaire label.

Logo

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals