DMX4ALL DMX 8 Relais Inrush User Manual

June 12, 2024
DMX4ALL

DMX4ALL-LOGO

DMX4ALL DMX 8 Relais Inrush

DMX4ALL-DMX-8-Relais-Inrush-product 

Product Information

Description
The DMX-RELAIS 8 INRUSH is designed for several control tasks. It has 8 potential free switching outputs with up to 8A switching capacity. The relay interface is suitable for both direct voltage (DC) and alternating voltage (AC). It also features an adjustable DMX FAIL function, RDM support, LED state display, and several operation modes.

Technical Data

Power supply 12-24V DC (280mA @ 12V / 180mA @ 24V)
Protocol DMX512 RDM
DMX-Channels 8 DMX channels
DMX-FAIL HOLD / 0-100%
Operation modes Hysteresis 127/128, Hysteresis 0/1, Hysteresis 100/150,

Exclusive, Monostable 1Second
Output| 8 potential-free switching output (closer / NO)
Switching capacity| AC: max. 8A / 250V~, DC: According to the max. DC load
graph
Connections| Screw terminals
Dimensions| 99mm x 82mm

Product Usage Instructions

Max. DC Load
The maximum current the switch contacts of the DMX RELAIS 8 INRUSH can switch is shown in the following graph depending on the switching voltage:

Description

The DMX-RELAIS 8 INRUSH is designed for several control tasks.

8 potential free switching outputs
The DMX-RELAIS 8 INRUSH has 8 potential free switching outputs (closer / NO) up to 8A switching capacity.

Switching contact for direct and alternating voltage
The relay interface is suitable to direct voltage (DC) or alternating voltage (AC).

DMX FAIL-Function
An adjustable DMX FAIL function offers the option to hold the current state (HOLD) or to adopt a predefined value if the DMX signal fails.

RDM support
The DMX-RELAIS 8 INRUSH allows the configuration via RDM or DMX.

LED-State Display
The DMX state is indicated via the LED status.

Several operation modes
The DMX-RELAIS 8 INRUSH offers several operating modes which can be set via jumper or RDM:

  • Hysteresis 127/128
  • Hysteresis 0/1
  • Hysteresis 100/150
  • Exclusive
  • Monostable 1Second

Top hat rail mounting available
Suitable for the DMX-RELAIS 8 INRUSH the DIN rail housing 1050 is available as accessory. Together with the top-hat rail housing 1050, the interface is optimally suited for control cabinet installation.

Technical Data

  • Power supply: 12-24V DC
    • (280mA @ 12V / 180mA @ 24V)
    • (Units before 2014 only 12V CD / 400mA)
  • Protocol: DMX512 RDM
  • DMX-Channels: 8 DMX channels
  • DMX-FAIL: HOLD / 0-100%
  • Operation modes :
    • Hysteresis 127/128
    • Hysteresis 0/1
    • Hysteresis 100/150
    • Exclusive Monostable 1Second
  • Output: 8 potential-free switching output (closer / NO) 165A@20ms peak switch-on current
    • AC: Each max. 8A / 250V~
    • DC: According to the max. DC load graph
  • Connections: Screw terminals
  • Dimensions: 99mm x 82mm

Max. DC load
The maximum current the switch contacts of the DMX RELAIS 8 INRUSH can switch is shown in the following graph depending on the switching voltage:

Connection

DMX4ALL-DMX-8-Relais-Inrush-fig- \(2\)

Switch contact

  • AC: each max. 8A / 250V~
  • DC: According to the max.

DC load graph (165A@20ms peak switch-on current)

LED-Display-Codes
The integrated green LED is a multi-function display. During to the normal operation mode the LED lights permanently. In this case the device is working. Furthermore, the LED shows the current status.

In this case the LED lights up in short pitches and then is missing for longer time. The number of the flashing lights is equal to the status number.

Event- number Error Description
1 NO DMX There is no DMX signal
2 Address error Please check the set DMX address

Addressing
The start address is adjustable about DIP switch 1-9. Thereby switch 1 has the valency 20 (=1), switch 2 the valency 21 (=2) and so on, up to switch 9 with the valency 28 (=256).

The sum of the values of the switches set to ON corresponds to the start address.

DMX-HOLD Function
The DMX-RELAIS 8 INRUSH has a DMX-FAIL function keeping the last DMX value (HOLD) or uses a predefined value set by RDM in case of a failed DMX signal. The HOLD function can be activated via RDM or switch 10:

  • Switch 10 ON  DMX-HOLD activated
  • Switch 10 OFF  DMX-HOLD not activated
    • (RDM configuration is used)

If HOLD is switched on (switch 10 = ON), the last received DMX values remain in case of a DMX signal failure.
If HOLD is switched off (switch 10 = OFF), the DMX values are replaced with a value set by RDM in case of a DMX signal failure. In the delivery state this value is 0, so that the relays switch off.

In case of a power failure, the DMX values held with HOLD are discarded!
A value set by RDM is deleted when HOLD is selected. After switching off the HOLD function, the default value 0 is used.

Select operating mode

Hysteresis 127/128
In this operating mode, the relays switch independently of each other each via one DMX channel. The switching threshold (Hysteresis) is 127/128 which means that the relay is switched off when the DMX value is 127 or less and that the relay is switched on when the DMX value is 128 or greater.

DMX

Channel

| DMX

Value

|

Function

---|---|---

1

| 0-127| Output 1 OFF
128-255| Output 1 ON

2

| 0-127| Output 2 OFF
128-255| Output 2 ON

3

| 0-127| Output 3 OFF
128-255| Output 3 ON

4

| 0-127| Output 4 OFF
128-255| Output 4 ON

5

| 0-127| Output 5 OFF
128-255| Output 5 ON

6

| 0-127| Output 6 OFF
128-255| Output 6 ON

7

| 0-127| Output 7 OFF
128-255| Output 7 ON

8

| 0-127| Output 8 OFF
128-255| Output 8 ON

For this operation mode choose via RDM the Personality 1.

Hysteresis 0/1
In this operating mode, the relays switch independently of each other each via one DMX channel. The switching threshold (Hysteresis) is 0/1 which means that the relay is switched off when the DMX value is 0 and that the relay is switched on when the DMX value is 1 or greater

DMX

Channel

| DMX

Value

|

Function

---|---|---

1

| 0| Output 1 OFF
1-255| Output 1 ON

2

| 0| Output 2 OFF
1-255| Output 2 ON
3| 0| Output 3 OFF
1-255| Output 3 ON

4

| 0| Output 4 OFF
1-255| Output 4 ON

5

| 0| Output 5 OFF
1-255| Output 5 ON

6

| 0| Output 6 OFF
1-255| Output 6 ON

7

| 0| Output 7 OFF
1-255| Output 7 ON

8

| 0| Output 8 OFF
1-255| Output 8 ON

For this operation mode choose via RDM the Personality 2.

Hysteresis 100/150
In this operating mode, the relays switch independently of each other each via one DMX channel.  The switching threshold (Hysteresis) is 100/150 which means that the relay is switched off when the DMX value is 100 or less and that the relay is switched on when the DMX value is 150 or greater.

DMX

Channel

| DMX

Value

|

Function

---|---|---

1

| 0-100| Output 1 OFF
101-149| Output 1 NO ACTION
150-255| Output 1 ON

2

| 0-100| Output 2 OFF
101-149| Output 2 NO ACTION
150-255| Output 2 ON

3

| 0-100| Output 3 OFF
101-149| Output 3 NO ACTION
150-255| Output 3 ON

4

| 0-100| Output 4 OFF
101-149| Output 4 NO ACTION
150-255| Output 4 ON

5

| 0-100| Output 5 OFF
101-149| Output 5 NO ACTION
150-255| Output 5 ON

6

| 0-100| Output 6 OFF
101-149| Output 6 NO ACTION
150-255| Output 6 ON

7

| 0-100| Output 7 OFF
101-149| Output 7 NO ACTION
150-255| Output 7 ON

8

| 0-100| Output 8 OFF
101-149| Output 8 NO ACTION
150-255| Output 8 ON

For this operation mode choose via RDM the Personality 3.

Exclusive (Jalousie-Control)
In this operating mode, 2 relays are linked to one another so that only one relay can switch at a time.  The switching threshold (hysteresis) is 127/128, which means that the relay is switched off when the DMX value is 127 or less. The relay is switched on when the DMX value is 128 or greater.  However, two linked relays (1 + 2/3 + 4/5 + 6/7 + 8) cannot be switched on at the same time.

DMX

Channel

| DMX

Value

|

Function

---|---|---

1

| 0-127| Output 1 OFF
128-255| Output 1 ON, if output 2 OFF

2

| 0-127| Output 2 OFF
128-255| Output 2 ON, if output 1 OFF

3

| 0-127| Output 3 OFF
128-255| Output 3 ON, if output 2 OFF

4

| 0-127| Output 4 OFF
128-255| Output 4 ON, if output 3 OFF

5

| 0-127| Output 5 OFF
128-255| Output 5 ON, if output 4 OFF

6

| 0-127| Output 6 OFF
128-255| Output 6 ON, if output 5 OFF

7

| 0-127| Output 7 OFF
128-255| Output 7 ON, if output 6 OFF

8

| 0-127| Output 8 OFF
128-255| Output 8 ON, if output 7 OFF

For this operation mode choose via RDM the Personality 4.

Monostable 1Second (Impulse)
In this operating mode, the relays switch independently of each other each via one DMX channel.  As soon as the DMX value is 128 or greater, the relay switches for 1 second. After that, the DMX value must first drop below 128 in order to trigger another switching pulse.

DMX

Channel

| DMX

Value

|

Function

---|---|---

1

| 0-127| Output 1 OFF
128-255| Output 1 1x 1-second ON

2

| 0-127| Output 2 OFF
128-255| Output 2 1x 1- second ON

3

| 0-127| Output 3 OFF
128-255| Output 3 1x 1- second ON

4

| 0-127| Output 4 OFF
128-255| Output 4 1x 1- second ON

5

| 0-127| Output 5 OFF
128-255| Output 5 1x 1- second ON

6

| 0-127| Output 6 OFF
128-255| Output 6 1x 1- second ON

7

| 0-127| Output 7 OFF
128-255| Output 7 1x 1- second ON

8

| 0-127| Output 8 OFF
128-255| Output 8 1x 1- second ON

For this operation mode choose via RDM the Personality 5.

RDM (from hardware V2.2)
RDM is the short form for Remote Device Management. As soon as the device is within the system, device-dependent settings can occur remotely via RDM command due to the uniquely assigned UID. A direct access to the device is not necessary. If the DMX start address is set via RDM, all address switches at the DMX- RELAIS 8 INRUSH must be set to OFF ! A DMX start address set by the address switches is always prior !

This device supports the following RDM commands:

Parameter ID| Discovery

Command

| SET

Command

| GET

Command

| ANSI/

PID

---|---|---|---|---
DISC_UNIQUE_BRANCH| |  |  | E1.20
DISC_MUTE| |  |  | E1.20
DISC_UN_MUTE| |  |  | E1.20
DEVICE_INFO|  |  | | E1.20
SUPPORTED_PARAMETERS|  |  | | E1.20
PARAMETER_DESCRIPTION|  |  | | E1.20
SOFTWARE_VERSION_LABEL|  |  | | E1.20
DMX_START_ADDRESS|  | | | E1.20
DEVICE_LABEL|  | | | E1.20
MANUFACTURER_LABEL|  |  | | E1.20
DEVICE_MODEL_DESCRIPTION|  | | | E1.20
IDENTIFY_DEVICE|  | | | E1.20
FACTORY_DEFAULTS|  | | | E1.20
DMX_PERSONALITY|  | | | E1.20
DMX_PERSONALITY_DESCRIPTION|  |  | | E1.20
DISPLAY_LEVEL|  | | | E1.20
DMX_FAIL_MODE|  | | | E1.37
Parameter ID| Discovery Command| SET

Command

| GET

Command

| ANSI/ PID
---|---|---|---|---
SERIAL_NUMBER1)|  |  | | PID: 0xD400
IDENTIFY_MODE1)|  | | | PID: 0xD402

Manufacturer depending RDM control commands (MSC – Manufacturer Specific Type)

Manufacturer depending RDM control commands:

SERIAL_NUMBER

PID: 0xD400
Outputs a text description (ASCII-Text) of the device serial number

GET| Send:| PDL=0|
---|---|---|---
 | Receive:| PDL=21| (21 Byte ASCII-Text)

IDENTIFY_MODE

PID: 0xD402
Stellt den Mode ein der mit IDENTIFY_DEVICE ausgeführt wird

GET| Send:

Receive:

| PDL=0

PDL=1

|

(1 Byte IDENTIFY_MODE_ID)

---|---|---|---
SET| Send: Receive:| PDL=1 PDL=0| (1 Byte IDENTIFY_MODE_ID)

IDENTIFY_MODE_ID Funktion

  • FULL Identify

All relays switch ON / OFF simultaneously and the status LED flashes

  • LOUD Identify

The relays switch ON / OFF one after the other and the status LED flashes

  • QUIET Identify

The relays do not switch, only the status LED flashes

Dimensions

DMX4ALL-DMX-8-Relais-Inrush-fig- \(5\)

Accessories

  • Top-hat rail housing 1050
  • Power supply 12V

CE-Conformity
This assembly (board) is controlled by a microprocessor and uses high frequency. In order to maintain the properties of the module with regard to CE conformity, installation into a closed metal housing in accordance with the EMC directive 2014/30/EU is necessary.

Disposal
Electronical and electronic products must not be disposed in domestic waste. Dispose the product at the end of its service life in accordance with applicable legal regulations.Information on this can be obtained from your local waste disposal company

Warning
This device is no toy. Keep out of the reach of children. Parents are liable for consequential damages caused by nonobservance for their children

Risk-Notes
You purchased a technical product. Conformable to the best available technology the following risks should not excluded:

Failure risk:
The device can drop out partially or completely at any time without warning. To reduce the probability of a failure a redundant system structure is necessary.

Initiation risk:
For the installation of the board, the board must be connected and adjusted to foreign components according to the device paperwork. This work can only bedone by qualified personnel, which read the full device paperwork and understand it.

Operating risk:
The Change or the operation under special conditions of the installed systems/components could as well as hidden defects cause to breakdown within the running time.

Misusage risk:
Any nonstandard use could cause incalculable risks and is not allowed.

Warning : It is not allowed to use the device in an operation, where the safety of persons depend on this device.

Last changes: 29.06.2022

© Copyright DMX4ALL GmbH
All rights reserved. No part of this manual may be reproduced in any form (photocopy, pressure, microfilm or in another procedure) without written permission or processed, multiplied or spread using electronic systems. All information contained in this manual was arranged with largest care and after best knowledge. Nevertheless, errors are to be excluded not completely. It is pointed out that neither a guarantee nor the legal responsibility or any liability for consequences which are due to incorrect information is assumed. This document does not contain assured characteristics. The guidance and the features may be changed at any time and without previous announcement.

DMX4ALL GmbH Reiterweg 2A D-44869 Bochum Germany
WWW.DMX4ALL.DE

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

DMX4ALL User Manuals

Related Manuals