DMX4ALL DMX 8 Relais Inrush User Manual
- June 12, 2024
- DMX4ALL
Table of Contents
DMX4ALL DMX 8 Relais Inrush
Product Information
Description
The DMX-RELAIS 8 INRUSH is designed for several control tasks. It has 8
potential free switching outputs with up to 8A switching capacity. The relay
interface is suitable for both direct voltage (DC) and alternating voltage
(AC). It also features an adjustable DMX FAIL function, RDM support, LED state
display, and several operation modes.
Technical Data
Power supply | 12-24V DC (280mA @ 12V / 180mA @ 24V) |
---|---|
Protocol | DMX512 RDM |
DMX-Channels | 8 DMX channels |
DMX-FAIL | HOLD / 0-100% |
Operation modes | Hysteresis 127/128, Hysteresis 0/1, Hysteresis 100/150, |
Exclusive, Monostable 1Second
Output| 8 potential-free switching output (closer / NO)
Switching capacity| AC: max. 8A / 250V~, DC: According to the max. DC load
graph
Connections| Screw terminals
Dimensions| 99mm x 82mm
Product Usage Instructions
Max. DC Load
The maximum current the switch contacts of the DMX RELAIS 8 INRUSH can
switch is shown in the following graph depending on the switching voltage:
Description
The DMX-RELAIS 8 INRUSH is designed for several control tasks.
8 potential free switching outputs
The DMX-RELAIS 8 INRUSH has 8 potential free switching outputs (closer /
NO) up to 8A switching capacity.
Switching contact for direct and alternating voltage
The relay interface is suitable to direct voltage (DC) or alternating
voltage (AC).
DMX FAIL-Function
An adjustable DMX FAIL function offers the option to hold the current state
(HOLD) or to adopt a predefined value if the DMX signal fails.
RDM support
The DMX-RELAIS 8 INRUSH allows the configuration via RDM or DMX.
LED-State Display
The DMX state is indicated via the LED status.
Several operation modes
The DMX-RELAIS 8 INRUSH offers several operating modes which can be set via
jumper or RDM:
- Hysteresis 127/128
- Hysteresis 0/1
- Hysteresis 100/150
- Exclusive
- Monostable 1Second
Top hat rail mounting available
Suitable for the DMX-RELAIS 8 INRUSH the DIN rail housing 1050 is available
as accessory. Together with the top-hat rail housing 1050, the interface is
optimally suited for control cabinet installation.
Technical Data
- Power supply: 12-24V DC
- (280mA @ 12V / 180mA @ 24V)
- (Units before 2014 only 12V CD / 400mA)
- Protocol: DMX512 RDM
- DMX-Channels: 8 DMX channels
- DMX-FAIL: HOLD / 0-100%
- Operation modes :
- Hysteresis 127/128
- Hysteresis 0/1
- Hysteresis 100/150
- Exclusive Monostable 1Second
- Output: 8 potential-free switching output (closer / NO) 165A@20ms peak switch-on current
- AC: Each max. 8A / 250V~
- DC: According to the max. DC load graph
- Connections: Screw terminals
- Dimensions: 99mm x 82mm
Max. DC load
The maximum current the switch contacts of the DMX RELAIS 8 INRUSH can
switch is shown in the following graph depending on the switching voltage:
Connection
Switch contact
- AC: each max. 8A / 250V~
- DC: According to the max.
DC load graph (165A@20ms peak switch-on current)
LED-Display-Codes
The integrated green LED is a multi-function display. During to the normal
operation mode the LED lights permanently. In this case the device is working.
Furthermore, the LED shows the current status.
In this case the LED lights up in short pitches and then is missing for longer time. The number of the flashing lights is equal to the status number.
Event- number | Error | Description |
---|---|---|
1 | NO DMX | There is no DMX signal |
2 | Address error | Please check the set DMX address |
Addressing
The start address is adjustable about DIP switch 1-9. Thereby switch 1 has
the valency 20 (=1), switch 2 the valency 21 (=2) and so on, up to switch 9
with the valency 28 (=256).
The sum of the values of the switches set to ON corresponds to the start address.
DMX-HOLD Function
The DMX-RELAIS 8 INRUSH has a DMX-FAIL function keeping the last DMX value
(HOLD) or uses a predefined value set by RDM in case of a failed DMX signal.
The HOLD function can be activated via RDM or switch 10:
- Switch 10 ON DMX-HOLD activated
- Switch 10 OFF DMX-HOLD not activated
- (RDM configuration is used)
If HOLD is switched on (switch 10 = ON), the last received DMX values remain
in case of a DMX signal failure.
If HOLD is switched off (switch 10 = OFF), the DMX values are replaced with a
value set by RDM in case of a DMX signal failure. In the delivery state this
value is 0, so that the relays switch off.
In case of a power failure, the DMX values held with HOLD are discarded!
A value set by RDM is deleted when HOLD is selected. After switching off the
HOLD function, the default value 0 is used.
Select operating mode
Hysteresis 127/128
In this operating mode, the relays switch independently of each other each via
one DMX channel. The switching threshold (Hysteresis) is 127/128 which means
that the relay is switched off when the DMX value is 127 or less and that the
relay is switched on when the DMX value is 128 or greater.
DMX
Channel
| DMX
Value
|
Function
---|---|---
1
| 0-127| Output 1 OFF
128-255| Output 1 ON
2
| 0-127| Output 2 OFF
128-255| Output 2 ON
3
| 0-127| Output 3 OFF
128-255| Output 3 ON
4
| 0-127| Output 4 OFF
128-255| Output 4 ON
5
| 0-127| Output 5 OFF
128-255| Output 5 ON
6
| 0-127| Output 6 OFF
128-255| Output 6 ON
7
| 0-127| Output 7 OFF
128-255| Output 7 ON
8
| 0-127| Output 8 OFF
128-255| Output 8 ON
For this operation mode choose via RDM the Personality 1.
Hysteresis 0/1
In this operating mode, the relays switch independently of each other each
via one DMX channel. The switching threshold (Hysteresis) is 0/1 which means
that the relay is switched off when the DMX value is 0 and that the relay is
switched on when the DMX value is 1 or greater
DMX
Channel
| DMX
Value
|
Function
---|---|---
1
| 0| Output 1 OFF
1-255| Output 1 ON
2
| 0| Output 2 OFF
1-255| Output 2 ON
3| 0| Output 3 OFF
1-255| Output 3 ON
4
| 0| Output 4 OFF
1-255| Output 4 ON
5
| 0| Output 5 OFF
1-255| Output 5 ON
6
| 0| Output 6 OFF
1-255| Output 6 ON
7
| 0| Output 7 OFF
1-255| Output 7 ON
8
| 0| Output 8 OFF
1-255| Output 8 ON
For this operation mode choose via RDM the Personality 2.
Hysteresis 100/150
In this operating mode, the relays switch independently of each other each
via one DMX channel. The switching threshold (Hysteresis) is 100/150 which
means that the relay is switched off when the DMX value is 100 or less and
that the relay is switched on when the DMX value is 150 or greater.
DMX
Channel
| DMX
Value
|
Function
---|---|---
1
| 0-100| Output 1 OFF
101-149| Output 1 NO ACTION
150-255| Output 1 ON
2
| 0-100| Output 2 OFF
101-149| Output 2 NO ACTION
150-255| Output 2 ON
3
| 0-100| Output 3 OFF
101-149| Output 3 NO ACTION
150-255| Output 3 ON
4
| 0-100| Output 4 OFF
101-149| Output 4 NO ACTION
150-255| Output 4 ON
5
| 0-100| Output 5 OFF
101-149| Output 5 NO ACTION
150-255| Output 5 ON
6
| 0-100| Output 6 OFF
101-149| Output 6 NO ACTION
150-255| Output 6 ON
7
| 0-100| Output 7 OFF
101-149| Output 7 NO ACTION
150-255| Output 7 ON
8
| 0-100| Output 8 OFF
101-149| Output 8 NO ACTION
150-255| Output 8 ON
For this operation mode choose via RDM the Personality 3.
Exclusive (Jalousie-Control)
In this operating mode, 2 relays are linked to one another so that only one
relay can switch at a time. The switching threshold (hysteresis) is 127/128,
which means that the relay is switched off when the DMX value is 127 or less.
The relay is switched on when the DMX value is 128 or greater. However, two
linked relays (1 + 2/3 + 4/5 + 6/7 + 8) cannot be switched on at the same
time.
DMX
Channel
| DMX
Value
|
Function
---|---|---
1
| 0-127| Output 1 OFF
128-255| Output 1 ON, if output 2 OFF
2
| 0-127| Output 2 OFF
128-255| Output 2 ON, if output 1 OFF
3
| 0-127| Output 3 OFF
128-255| Output 3 ON, if output 2 OFF
4
| 0-127| Output 4 OFF
128-255| Output 4 ON, if output 3 OFF
5
| 0-127| Output 5 OFF
128-255| Output 5 ON, if output 4 OFF
6
| 0-127| Output 6 OFF
128-255| Output 6 ON, if output 5 OFF
7
| 0-127| Output 7 OFF
128-255| Output 7 ON, if output 6 OFF
8
| 0-127| Output 8 OFF
128-255| Output 8 ON, if output 7 OFF
For this operation mode choose via RDM the Personality 4.
Monostable 1Second (Impulse)
In this operating mode, the relays switch independently of each other each
via one DMX channel. As soon as the DMX value is 128 or greater, the relay
switches for 1 second. After that, the DMX value must first drop below 128 in
order to trigger another switching pulse.
DMX
Channel
| DMX
Value
|
Function
---|---|---
1
| 0-127| Output 1 OFF
128-255| Output 1 1x 1-second ON
2
| 0-127| Output 2 OFF
128-255| Output 2 1x 1- second ON
3
| 0-127| Output 3 OFF
128-255| Output 3 1x 1- second ON
4
| 0-127| Output 4 OFF
128-255| Output 4 1x 1- second ON
5
| 0-127| Output 5 OFF
128-255| Output 5 1x 1- second ON
6
| 0-127| Output 6 OFF
128-255| Output 6 1x 1- second ON
7
| 0-127| Output 7 OFF
128-255| Output 7 1x 1- second ON
8
| 0-127| Output 8 OFF
128-255| Output 8 1x 1- second ON
For this operation mode choose via RDM the Personality 5.
RDM (from hardware V2.2)
RDM is the short form for Remote Device Management. As soon as the device is
within the system, device-dependent settings can occur remotely via RDM
command due to the uniquely assigned UID. A direct access to the device is not
necessary. If the DMX start address is set via RDM, all address switches at
the DMX- RELAIS 8 INRUSH must be set to OFF ! A DMX start address set by the
address switches is always prior !
This device supports the following RDM commands:
Parameter ID| Discovery
Command
| SET
Command
| GET
Command
| ANSI/
PID
---|---|---|---|---
DISC_UNIQUE_BRANCH| | | | E1.20
DISC_MUTE| | | | E1.20
DISC_UN_MUTE| | | | E1.20
DEVICE_INFO| | | | E1.20
SUPPORTED_PARAMETERS| | | | E1.20
PARAMETER_DESCRIPTION| | | | E1.20
SOFTWARE_VERSION_LABEL| | | | E1.20
DMX_START_ADDRESS| | | | E1.20
DEVICE_LABEL| | | | E1.20
MANUFACTURER_LABEL| | | | E1.20
DEVICE_MODEL_DESCRIPTION| | | | E1.20
IDENTIFY_DEVICE| | | | E1.20
FACTORY_DEFAULTS| | | | E1.20
DMX_PERSONALITY| | | | E1.20
DMX_PERSONALITY_DESCRIPTION| | | | E1.20
DISPLAY_LEVEL| | | | E1.20
DMX_FAIL_MODE| | | | E1.37
Parameter ID| Discovery Command| SET
Command
| GET
Command
| ANSI/ PID
---|---|---|---|---
SERIAL_NUMBER1)| | | | PID: 0xD400
IDENTIFY_MODE1)| | | | PID: 0xD402
Manufacturer depending RDM control commands (MSC – Manufacturer Specific Type)
Manufacturer depending RDM control commands:
SERIAL_NUMBER
PID: 0xD400
Outputs a text description (ASCII-Text) of the device serial number
GET| Send:| PDL=0|
---|---|---|---
| Receive:| PDL=21| (21 Byte ASCII-Text)
IDENTIFY_MODE
PID: 0xD402
Stellt den Mode ein der mit IDENTIFY_DEVICE ausgeführt wird
GET| Send:
Receive:
| PDL=0
PDL=1
|
(1 Byte IDENTIFY_MODE_ID)
---|---|---|---
SET| Send: Receive:| PDL=1 PDL=0| (1 Byte IDENTIFY_MODE_ID)
IDENTIFY_MODE_ID Funktion
- FULL Identify
All relays switch ON / OFF simultaneously and the status LED flashes
- LOUD Identify
The relays switch ON / OFF one after the other and the status LED flashes
- QUIET Identify
The relays do not switch, only the status LED flashes
Dimensions
Accessories
- Top-hat rail housing 1050
- Power supply 12V
CE-Conformity
This assembly (board) is controlled by a microprocessor and uses high
frequency. In order to maintain the properties of the module with regard to CE
conformity, installation into a closed metal housing in accordance with the
EMC directive 2014/30/EU is necessary.
Disposal
Electronical and electronic products must not be disposed in domestic
waste. Dispose the product at the end of its service life in accordance with
applicable legal regulations.Information on this can be obtained from your
local waste disposal company
Warning
This device is no toy. Keep out of the reach of children. Parents are
liable for consequential damages caused by nonobservance for their children
Risk-Notes
You purchased a technical product. Conformable to the best available
technology the following risks should not excluded:
Failure risk:
The device can drop out partially or completely at any time without warning.
To reduce the probability of a failure a redundant system structure is
necessary.
Initiation risk:
For the installation of the board, the board must be connected and adjusted to
foreign components according to the device paperwork. This work can only
bedone by qualified personnel, which read the full device paperwork and
understand it.
Operating risk:
The Change or the operation under special conditions of the installed
systems/components could as well as hidden defects cause to breakdown within
the running time.
Misusage risk:
Any nonstandard use could cause incalculable risks and is not allowed.
Warning : It is not allowed to use the device in an operation, where the safety of persons depend on this device.
Last changes: 29.06.2022
© Copyright DMX4ALL GmbH
All rights reserved. No part of this manual may be reproduced in any form
(photocopy, pressure, microfilm or in another procedure) without written
permission or processed, multiplied or spread using electronic systems. All
information contained in this manual was arranged with largest care and after
best knowledge. Nevertheless, errors are to be excluded not completely. It is
pointed out that neither a guarantee nor the legal responsibility or any
liability for consequences which are due to incorrect information is assumed.
This document does not contain assured characteristics. The guidance and the
features may be changed at any time and without previous announcement.
DMX4ALL GmbH Reiterweg 2A D-44869 Bochum Germany
WWW.DMX4ALL.DE
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>