DMX4ALL D-44869 ArtNet LED Dimmer 6 User Manual
- June 12, 2024
- DMX4ALL
Table of Contents
- D-44869 ArtNet LED Dimmer 6
- Description
- Technical Data
- Content
- Examples for Connections
- LED-Display
- Set IP with IP-Configurator
- Set IP with web browser
- Device Configuration
- Master Dimmer
- User-defined color changes / programs
- Editing via Web-Browser
- Editing via DMX-Configurator
- Editing via Android App / Executing programs
- Digital Inputs IN1/IN2
- Live-Controlling via App
- Operating in WLAN
- Factory Reset without Web-Interface
- Executing Update
- Dimension
- Equipment
- CE-Conformity
- Disposal
- Warning
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
ArtNet-LED-Dimmer 6
User Manual
D-44869 ArtNet LED Dimmer 6
Art-Net™ Designed by and Copyright Artistic Licence Holdings Ltd.
For your own safety, please read this user manual and warnings carefully
before installation.
For the described range of functions the firmware version 1.1 or higher is
needed (Execute the Firmware-Update see page 18).
Description
The ArtNet Dimmer 6 is a compact LED-Dimmer with 6 separate LED-outputs.
These can be used for RGB/ RGB+W / RGB + W WW or for single color stripes.
High Power Outputs
Each output can drive a current up to 10A.
So it is possible to connect a maximum load on each output of 120W (12V) or
240W (24V).
16 Million Colors
With the RGB-LED-Stripe up to 16 million colors can be adjusted.
By using an additional single color white stripe it is possible to make color
neutral illuminations or pastel colors.
User Defined Color Changes
The ArtNet-LED Dimmer 6 has also 10 user configurable color programs which can
be defined via the web browser or the Android App „DMX4ALL Remote“.
Two digital inputs
The digital inputs IN1 and IN2 can be used to select the color changes /
programs with a push button.
User-friendly Configuration
A user-friendly configuration via a web browser allows a fast and
uncomplicated setting of all parameters.
Power Supply for WLAN-Bridge
In addition, the ArtNet-Dimmer 6 has a USB connector providing a power supply
with 5V/500mA for external devices e.x. a WLAN bridge.
As WLAN-bridge we suggest: TP-Link TL-WR702N or TP-Link TL-WR802N.
Control with App
The control of this device is possible by using the free Android-App “DMX
Remote”.
Firmware-Update-Function
In order to take advantage of future features, the ArtNet-LED-Dimmer 6 has a
firmware update function.
This can be launched from the browser so that no access to the device is
necessary!
DMX4ALL-Command interface
The ArtNet-LED-Dimmer 6 has another TCP communication interface.
This interface uses DMX4ALL-commands via TCP packets.
NEW ADVANCED SCOPE OF FUNCTIONS: Now, this allows to fade outputs to a value
over a specified period of time.
Technical Data
Power supply: 12-24V DC / 100 mA
LED-Voltage: 12-24V DC (no AC voltage !)
Connection: RJ45 Ethernet Screw terminals USB-Typ-A 1.1 /2.0
LED-Connection: 6x Output max. 10A per output (in sum 60A) common anode
(+)
PWM-Frequency: 250 Hz / 500 Hz / 1000 Hz / 2000 Hz
USB-Connection: 5V/500mA for power supply external devices (e.g. WLAN-
Bridge)
Protocol: Art-Net 3™ (downward compatible) DMX4ALL Commands
Dimension: 64,2 mm x 82 mm x 20 mm
Content
1x ArtNet-LED-Dimmer 6
1x Quick guide german and english
Examples for Connections
Example with 2 separate controllable RGB-LED-Stripes and a central power
supply:———
Connections according to the needed power for the LED-Stripes directly wired
from power supply !
Example with a RGB-LED-Stripe (12V) and 3 single color LED-Stripes (24V) with
separated power supply:——— Connections according to the needed power for the LED-
Stripes directly wired from power supply !
LED-Display
LED green
The green LED lights up if no Ethernet connection is available and lights up
permanent if an Ethernet connection exists.
LED yellow
The yellow LED lights up as soon as data are received.
Set IP with IP-Configurator
The IP Configurator allows to set the IP address and the net mask even if the
network setting of the PC is not in the IP range of the ArtNet LED Dimmer 6.
– Install the software IP-Configurator
– Connect the ArtNet-LED-Dimmer 6 with the network and start the device
– Start the software IP-Configurator– The ArtNet-LED-Dimmer 6 is shown in the list
– Click the entry
– Enter the IP and net mask
– Click SET
Set IP with web browser
The assigned IP-address 2.0.0.10 by delivery will be used for the web-
interface as well as for the ArtNet.
Set the computers network card to this IP range to access the IP address
2.0.0.10 via the web browser.
The network settings of the PC must be configured to the IP-address 2.0.0.1
and the subnet mask to 255.0.0.0.
Please quote the ArtNet-specifications for further details.
Device Configuration
Please call the ArtNet-LED-Dimmer 6 IP in the address bar of the web browser
(delivery status 2.0.0.10) to get the following configuration page: Each
node needs an own IP-address, so the assignment in the network occurs clearly.
According to the ArtNet-specifications please use the IPaddresses 2.x.x.x or
10.x.x.x.
The Subnetmask is 255.0.0.0 according to the ArtNet-specifications.
Using other IP-addresses
Other IP addresses are possible too, e.g. 192.168.1.10. In this case the
Netmask must be changed to 255.255.255.0!
For an easier identification you can assign each node with any names.
The Short-name is limited to 18 signs and the Long-name to 64 signs.
In the ArtNet settings the adjustment for the Subnet, Net and Port (Universe)
is possible.
The DMX-Starting address specifies the channel in the DMX-Universe at which
the LED outputs are responded. Thereby the DMX-Starting address corresponds to
the output 1 and the following addresses correspond to the outputs 2-4.
The Master Dimmer can be activated if all outputs should be dim via another
ArtNetChannel.
This is possible during the StandAlone-Operation as well as via the
ArtNetOperation. Thereby the Master-Channel is the first channel. An
adjustable Default value shows which value is identified after switch on the
dimmer.
The PWM-Output frequency from the LED-driver is adjustable under Output
Frequency. You can select between the values 250Hz / 500 Hz / 1000Hz and
2000Hz.
POWER ON defaults (StandAlone) allows operating without connecting an ArtNet
device. The adjusted program will be run after switching on the device. If
data are received from an ArtNet-controlling device for an output greater than
0, the program will be automatically finished and the outputs get the settings
coming from ArtNet.
Enable ArtNet-Master for StandAlone is for outputting the StandAlone-Programs.
The outputted values are transmitted via ArtNet to the adjusted
Net/SubNet/Universe from at the assigned start address via Broadcast. So it is
possible to run several ArtNet-LED-Dimmer synchronously.
An user-defined color-gradient can be used under User Color. The User Color
Setup is described on the following pages.
The Factory Settings will be restored with entering the number 7319.
SAVE restored the configuration respectively restored the Factory settings.
Master Dimmer
The ArtNet-LED-Dimmer 6 supports a Master-Dimmer to dim all outputs at the
same time. This Master-Dimmer must be activated in the Web-configuration.
The ArtNet channel given by the Start-address is used for the Master-Dimmer
channel. The assignment occurs as follows:Is no Master-Dimmer activated the assignment is
as follows:The
Master-Dimmer can be used also to dim the expressed Stand-Alone-Program or to
dim the user-defined color-change.
The Default-Value shows which value is used for running the Master-Dimmer
after switching on the device.
It is also possible to change the Master-Dimmer by ArtNet during the
StandAlone-Program is running. In this case the output values must be hold to
0 ! If an output value greater than 0 will be received the reproduction ends
and the Live-Output of the received values starts.
User-defined color changes / programs
The ArtNet-LED-Dimmer 6 has 10 user-defined color changes / programs (User
Color) which allow an open defined color-reproduction up to 16 steps.
These programs are predefined for operating with RGB-LED-Stripes in the
delivery conditions. All programs (User 1 – User 10) can be editing free.
Editing via Web-Browser
For editing a program please select this program under the main menu 1 and
then call Edit User Color 2.By clicking User Color Setup within the main menu from the
Web-interface the dialog USER COLOR SETUP for editing the user-defined color-
change / programs is shown:Entering User color change a table of the current 16 steps
is shown (Step 1 up to Step 16). If there are not used steps there is no value
in the table.
Each step consists of a Fade Time, a Wait Time and 6 brightness-values for the
outputs (CH1 – CH6).
Naming the user-defined programs
For a simply recognition of the created program this will be named. This name
will be used for calling within the Remote-App.
Deleting the user-defined programs
By clicking Clear the whole table will be deleted.
Creating Steps
With New color Step you can enter the values for a new step.
The Fade Time is divided in 0,1s units between 0 and 65000. A value of 10
corresponds to 1 second and a value of 600 corresponds to 1 minute.
The Wait Time is just the same in 0,1s units between 0 and 65000. A value of
10 corresponds to 1 second and a value of 600 corresponds to 1 minute.
In the fields Channel 1 up to Channel 6 the brightness value 0-255 for the
outputs 1 up to 6 will be entered. A value to 255 corresponds to 100%.
Click Add and the step after the last used step will be attached and adopted
into the scale.
By activating the selection box Use actual channel values the current
brightness values which are set up will be adopted, not the entry field’s
brightness values. Thus it is possible to set up any color via App and to
adopt this one as a step in the user-defined color change. The Fade Time and
Wait Time must be specified furthermore.
The table has to be stored with Save. If Save will be not executed the
settings will be not adopted permanent and after turning off the ArtNet-LED-
Dimmer 6 all settings will be lost.
Saving the user-defined program
Select Save for storing the scale in the ArtNet-LED-Dimmer 6. After
switching on the device the color change will be replayed as long as a set up
via Ethernet for example via App takes place.
Editing via DMX-Configurator
The user-defined color changes / programs can be edited with the free
DMXConfigurator software.
First, an ArtNet connection is needed.
Then, the color changes / programs can be read out from the ArtNet LED Dimmer
6 within the menu Hardware→Read stand alone programs.Now,
the color changes / programs are imported and ready for editing.
The DMX channels 1 up to 6 (Ch1 up to Ch6) correspond to the outputs 1 to 6 at
the dimmer.After completed editing, the color changes / programs
are transferred to the ArtNet DMX Dimmer 6 via the menu Hardware→Write stand
alone programs.
Editing via Android App / Executing programs
The user defined color changes / programs the ArtNet-LED-Dimmer 6 can be
called / edited via the Android App DMX4ALL Remote.
The App DMX4ALL Remote is free available in the Google Play-Store and can be
installed on Smartphones with Android 4.0 or higher.
After starting the App for the first time the ArtNet-LED-Dimmer 6 IP must be
declared in the main settings .After leaving the settings the programs out of the
ArtNet-LED-Dimmer 6 will be load and shown in the list.By
tipping a programs name within the list the according program will be run via
the ArtNet-LED-Dimmer. The executed program is marked with a symbol .
By tipping the ongoing program will be stopped.
By tipping a stopped program will be replayed furthermore.
Tipping the switch the outputs will be switched off or on. If the Blackout-
function is activated this button is displayed in a red color.
By tipping the RGB Channel Control opens. Hereby the ArtNet-LED-Dimmer can be
used live.
For adjusting the playback speed and brightness two sliders (Speed,
Brightness) exist.
Editing programs
For editing a program, the programs name must be pushed for al longer time
(ca. 1 second). The User Step Editor opens:
A list with all single steps will be shown. In each entry the Fade Time, Wait
Time and the channel value is shown.
Above the list the programs name is shown, which is editable too.
Short tipping to an entry select this and the values will be displayed the
area below (Step parameter) as well as transmitted to the ArtNet-LED-Dimmer.
The entry is marked darkly: Long holding an entry deletes the selected step.
The area Step Parameter displayed the adjusted values. Via the sliders the
channel values will be adjusted and transmitted to the ArtNet-LED-Dimmer. So,
the adjusted light picture can be reviewed.
The Fade Time and Wait Time define the wait time and fade time in seconds.
Add adds a step with the current value, which are adjusted under the Step
Parameters, to the end of the list.
Replace replaces the selected entry with the current Step Parameter values.
Clear deletes all entries in the list.
Save on Device stores the created program to the ArtNet-LED-Dimmer.
A request appears if the program should be stored (Save Steps only) or whether
the program should be stored and defined as start-program (Save Steps + Set as
start program).
Save Program
Do you want to save ?
Save nothing| Save steps only| Save steps + Set as start program
Export / Import programs
It is possible to export or import an created program as file on a
Smartphone with .The internal memory as well as an external memory by a
SD-card can be used for the export / import.
By tipping Internal Memory or External Memory the storage location will be
selected.
The shown files (.dmx) can be load with tipping and deleted with long holding.
Storing the current program occurs with tipping Save Prog. The files name will
be assigned automatically.
Digital Inputs IN1/IN2
The digital inputs IN1 and IN2 can be used to select the color changes /
programs with a push button.
Input IN1: switches to next color changes / programs
Input IN2: switches to previous color changes / programs
If a push button is connected between IN1 and GND (see figure), it can be used
to select the self-defined color changes / programs in rising order (User 1 >
User 10). If the last of the color changes / programs is executed and the
button is pressed again, the first of the color changes / programs starts
again.If a
button is connected between IN2 and GND, it can be used to select the color
changes / programs in reverse order (User 10 > User 1).
If the first of the color changes / programs is executed and the button is
pressed again, the last of the color changes / programs starts.
If a color change / program doesn’t contain a stored program step, it will be
skipped when selected by the button/s.
Live-Controlling via App
The ArtNet-LED-Dimmer 6 can be controlled live via an App.
Android Smartphones
– Light Remote LITE (with costs)
App for an easy remote control for Art-NetInstallations integrated a user-
friendly design, an attractive arranged surface with easy possibilities for
color settings.
⇒ Advised for installations with one ArtNetLED-Dimmer – Light Remote (with
costs)
App for an easy remote control for Art-NetInstallations integrated a user-
friendly design, an attractive arranged surface with easy possibilities for
color settings.
⇒ Recommended for installations with several ArtNet-LED-Dimmer
– SmartRemote (free)
App for an easy remote control of Art-Net installations integrates a user-
friendly design, an attractive designed interface with simple options for
color adjustment.
⇒ Recommended for installations with several ArtNet-LED-Dimmer
Operating in WLAN
The ArtNet-LED-Dimmer 6 can be operated with a WLAN Router/Access-Point or
with a WLAN-bridge.
Operating with WLAN Router/Access-Point
Operating with WLAN- Bridge
- Smartphone / Tablet / PC
- WLAN Router/Access-Point
- ArtNet-LED-Dimmer 6
- WLAN-Bridge e.g. TL-WR702N
Factory Reset without Web-Interface
The ArtNet-LED Dimmer 6 can be reset into the delivery conditions with the
Resetbutton within the device.
Please proceed als follows:
– Turn off the device
– Push button and hold
– Turn on the device
– The yellow LED lights up
– Release button
– Push the button and hold again
– Green and yellow LED lights up alternately ca. 10 seconds.
– Release the button meanwhile
– The reset will be executed and the LEDs lights up 3x simultaneously to the
confirmation.
Alternatively, you can generate the delivery conditions via the Web browser:
– Open the Main Setup within the web browser
– Enter the shown Code „7319“ in the Factory defaults
– Click Save
– Then, please wait 20 seconds at least
Executing Update
The ArtNet-LED Dimmer 6 has an Update-function which allows transferring
prospective Firmware versions.
Please proceed als follows:
– Turn off the device
– Push button and hold
– Turn on the device
– Yellow LED lights up
– Release button
– Generate Network-connection to PC
– Start Update-Software DMX4ALL LAN-Updater
– Select ArtNet-LED-Dimmer 6 from list
– Click Firmware-Update
– Select Firmware-Data (.bin) and certify
– Please wait until Update has finished
Dimension
(all details in mm)
Equipment
RGB-LED-Stripe 5mLED-Stripe white![DMX4ALL D-44869 ArtNet LED Dimmer 6
- fig 25](https://manuals.plus/wp-content/uploads/2023/08/DMX4ALL-D-44869 -ArtNet-LED-Dimmer-6-fig-25.jpg)Power supply 12V / 5A
CE-Conformity
This assembly (board) is controlled by a microprocessor and uses high frequency. In order to maintain the properties of the module with regard to CE conformity, installation into a closed metal housing in accordance with the EMC directive 2014/30/EU is necessary.
Disposal
Electronical and electronic products must not be disposed in domestic waste.
Dispose the product at the end of its service life in accordance with
applicable legal regulations.
Information on this can be obtained from your local waste disposal company.
Warning
This device is no toy. Keep out of the reach of children. Parents are liable
for consequential damages caused by nonobservance for their children.
Risk-Notes
You purchased a technical product. Conformable to the best available
technology the following risks should not excluded:
Failure risk:
The device can drop out partially or completely at any time without warning.
To reduce the probability of a failure a redundant system structure is
necessary.
Initiation risk:
For the installation of the board, the board must be connected and adjusted to
foreign components according to the device paperwork. This work can only be
done by qualified personnel, which read the full device paperwork and
understand it.
Operating risk:
The Change or the operation under special conditions of the installed
systems/components could as well as hidden defects cause to breakdown within
the running time.
Misusage risk:
Any nonstandard use could cause incalculable risks and is not allowed.
Warning:
It is not allowed to use the device in an operation, where the safety of
persons depend on this device.
Last change: 16.08.2022
© Copyright DMX4ALL GmbH
All rights reserve. No part of this manual may be reproduced in any form
(photocopy, pressure, microfilm or in another procedure) without written
permission or processed, multiplied or spread using electronic systems.
All information contained in this manual was arranged with largest care and
after best knowledge. Nevertheless, errors are to be excluded not completely.
For this reason, I see myself compelled to point out that I can take over
neither a warranty nor the legal responsibility or any adhesion for
consequences, which decrease/go back to incorrect data. This document does not
contain assured characteristics. The guidance and the characteristics can be
changed at any time and without previous announcement.
WWW.DMX4ALL.DE
DMX4ALL GmbH
Reiterweg 2A
D-44869 Bochum
Germany
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>