cata CTRS-50 REV SLIM Water Boiler Instruction Manual

June 12, 2024
cata

cata CTRS-50 REV SLIM Water Boiler

Product Information

  • Model: CTRS-50 REV SLIM, CTRS-80 REV SLIM
  • Volume (L): CTRS-50 REV SLIM – 47L, CTRS-80 REV SLIM – 74L
  • Power (W): 2000W
  • Voltage (ACV): 220-240V
  • Waterproof Rating: IPX4

Product Usage Instructions

  1. This electric water heater should be installed in a solid wall. Ensure that the wall can bear the weight of the heater fully filled with water.
  2. Select a proper location for installation and determine the positions of the two installation holes for expansion bolts with hooks.
  3. Make two holes in the wall with the correct depth and size matching the expansion bolts. Insert the screws, place the hooks upwards, and tighten the nuts to firmly fix them.
  4. Hang the electric water heater on the hooks securely.
  5. Install the supply socket in the wall. The socket should meet the following requirements: 250V/10A, single phase, three electrodes. It is recommended to place the socket above the heater at a height not less than 1.8m from the ground.

We would like to sincerely thank you for selecting our electric water heater. Please read this manual carefully before use and the methods for the installa- tion and use of this electric water heater, to make full use of its excellent performances.

WARNING

  • Before installing this water heater, check and confirm the earth electrode on the socket is reliably grounded, without electricity. Otherwise, the electric water heater can not be installed or used.
  • Do not use mobile sockets.
  • Incorrect installation and use of this electric water heater may result in serious injuries to human bodies and losses of property.

Performance characteristics

  1. Total automatic control: automatic addition o f cold water, automatic heat-ing.
  2. Three-fold safety protection: multiple safety protection devices, such as dry heating protection, extra-temperature protection, high hydraulic pressure protection, etc., safe and reliable.
  3. Sapphire enamel inner container: manufactured by using advanced electr- ostatic dry method enamel technique, antirust, corrosion-proof, incrusta-tion- resistant, leak-prevention, with longer lifetime.
  4. Heating pipes designed with low thermal load: safe and reliable, with longer lifetime.
  5. Equipped with corrosion-proof and incrustation-retardant equipment: durable products.
  6. Thickened urethane integral foaming: good thermal insulation effect, energy efficient and electricity saving.
  7. Imported temperature controller: accurate and reliable control of tempera-ture.
  8. Adjustable range of water temperature from 30 to 75℃.
  9. Simple operation and easy use.

Specifications


Model

| Volum (L)| Potencia (W)| Volt (ACV)| Presion (MPa)| Maxico temperatura del agua| Clase

protección

| ****

Impermeabilidad

---|---|---|---|---|---|---|---
CTRS-50REVSLIM| 47| 2000| 220-240| 0.75| 75| I| IPX4
CTRS-80REVSLIM| 74| 2000| 220-240| 0.75| 75| I| IPX4

Brief introduction of product structure

cata CTRS-50 REV SLIM Water Boiler-FIG1

Methods of installation

Note:Please make sure to use the accessories provided by our company to install this electric water heater. This electric water heater can not be hung on the support until it has been checked that it is firm and reliable. Otherwise, the electric water heater may face from the wall, resulting in damage of the heater, even serious accidents or injuries to people. When determining the locations of the bolt holes, it shall be ensured that there is a clearance not less than 0.2m on the right side of the electric heater, to facilitate the maintenance of the heater, if necessary.

Installation of the main machine

  1. This electric water heater should be installed in a solid wall. If the strength of the wall can’t bear theweight equalling twice. The total weight of the heater fully filled with water, it will be necessary to install a special support.
  2. After selecting a proper location, determine the positions of the two installa- tion holes used for expansion bolts with hook (determined according to the specification of the product you select). Make two holes in the wall with the right depth by drilling the correct size matching the expansion bolts attached, insert the screws, place the hook upwards, tighten the nuts so that they are firmly fixed, and then hang the electric water heater on it (see Fig.2).cata CTRS-50 REV SLIM Water Boiler-FIG2
  3. Install the supply socket in the wall. The requirements for the socket are as follows: 250V/10A, single phase, three electrodes. It is recommended to place the socket on the right above the heater. The height from the socket to the ground shall not be less than 1.8m (see Fig.3).
  4. The heater can be installed, anywhere in the house not exposed to direct sunlight or rain. However, in order to reduce the pipeline heat losses, the installation position of the heater shall be closed to the location for use of water as near as possible.

Connection of pipelines

  1. The dimension of each pipe part is G1/2.
  2. Connection of one-way safety valve:install the one-way safety valve attached with the machine at the water inlet of the main machine.(Pay attention to keep the installed drainage flexible pipes of the safety valve sloping downwards and connected with the atmosphere.)
  3. In order to avoid leakage when connecting the pipelines, the rubber seal gaskets provided with the machine must be added at the end of the threads (see Fig.4).cata CTRS-50 REV SLIM Water Boiler-FIG5
  4. If the users want to make a multi-way supply system, refer to the method shown in Fig.5 for connection of the pipelines.cata CTRS-50 REV SLIM Water Boiler-FIG6

Methods of use

  1. First, open any of the outlet valves at the outlet of the water heater, then,open the inlet valve. The electric water heater begins to be filled with water. When there is water coming out of the outlet valve normally, it implies that the heater has been fully filled with water, and the outlet valve can be closed.
    Note: During normal operation, the inlet valve shall be set in the status of “open”.

  2. Insert the supply plug into the socket, the two indicator lights will be on at the same time..

  3. This machine can automatically control the temperature. When the water temperature inside the machine has reached the set temperature (It is set to 75℃), it will be turned off automatically, and step into the status of thermal insulation; when the water temperature is decreased to a certain point, it will be turned on automatically to restore the heating, and the use of hot water will not be interrupted. When the heater is switched off auto- matically, the heating indicator will turn off.

  4. Operating Of The Unitcata CTRS-50 REV SLIM Water Boiler-FIG7

  5. “1” button is for frequency switch. When press firstly, display screen “4” will show the three frequency option( index number “1” means 1200W, index number “2” means 2000W , index number “3” means smart control energy saving mode) , The number “3” of light “6“ will blink on the screen .

  6. “2” is the on/off button, when press , water heater start working,display screen will be lighted up. Then press again, electricty will be cut off, and display screen will be shut down.

  7. “3” is for temperature adjustment knob with 360 °loop. Temperature increases by clockwise rotation, and decreases if anticlockwise. During the rotation , desplay screen ” 4″ will change accordingly. When temperature setting meets customers’ requirements, stop rotating and display screen “4” will flash for around 3 seconds, which means temperature has been setted successfully. After flashing ,display screen “4” value will return to current inner water heater temperature. After the smart control energy saving mode, the knob can not be adjusted.

  8. “6” is for frequency display. If number ” 1″ comes out , it means 1200W(only one tank is heating ) ; If number “2” comes out , it means 2000W (the two inner tank has been being heated up ), If number ” 3″ comes out , it means smart control energy saving mode, the water temperature is automatically changed. The appliance works to reduce the electricity energy of the user consumption, which allows heat loss to be minimized and energy savings to be maximized. This function is manually activated, The user can press the MODE button three time at 0 AM local time to start the smart control function and calibrate the time and hot water usage;

  9. From “5” &“7”(this horizontal strip ) , customer could tell heating status . The light “5” will turn on when power is connected. The light “5“ will blink , when smart control energy saving mode is started , According the temperature setted, the light “7” will be shown in red which means water heater is being heated. When inner water heater temperature reaches the setted value , light “7” will turns off , which means water heater enter into warm-keeping status.

  10. “4” could show the current inner water temperature as well as setted temperature value.If no person operates on water heater , the value in display screen ” 4″ means current temperature value .By spinning knob “3” , “4” values will vary accordingly ( i.e temperature setting process) , when finish temperature setting , “4” values will return back to actual current inner water heater temperatrue.

Error code for serviceman’s use
E2: Dry Ashing—Top up with water and re-heat.
E3: Overheating—Check the heating system or replace it.
E4: Sensor Fault—Check the sensor or replace it.

Cautions

  1. The supply socket must be earthed reliably. The rated current of the socket shall not be lower than 10A. The socket and plug shall be kept dry to prevent electric leakage. Inspect frequently whether the plugs are well plugged in the socket. Inspect method is as follows: insert the power supply plug into the socket,after using for half an hour, shut down the unit and pull the plug out, and inspect the plug in case it scalds your hand. If tempeature is over 50℃, please plug in another socket. to avoid the plug being damaged, fire or other personnel accidents result from badcontact.
  2. For the places or the wall where the water may splash, the installation height of the socket shall not be lower than 1.8m.
  3. The wall in which the electric water heater is installed shall be able to bear the weight equalling twice the weight of the heater fully filled with water without distortion or cracks. Otherwise, other strengthening measures should be adopted.
  4. The one-way safety valve attached to the machine must be installed to the cold water inlet of this machine (see Fig.6).
  5. For the first use (or the first use after maintenance or cleaning), the heater can not be switched on until it has been (fully) filled with water. When filling with water, at least one of the outlet valves at the outlet of the heater must be opened to release the air. This valve can be closed after the heater has been (fully) filled with water.
  6. During the heating, there may be drops of water dripping from the pressure release hole of the one-way safety valve. This is a normal phenomenon. If there is a large amount of water leaking, please contact the professional maintenance personnel for repair. This pressure release hole shall, under no circumstances, be blocked; otherwise, the heater may be damaged, even resulting in safety accidents.cata CTRS-50 REV SLIM Water Boiler-FIG8
  7. The drainage pipe connected to the pressure release hole must be kept sloping downwards.
  8. Since the water temperature inside the heater can reach up to 75℃, the hot water must not be exposed to people when it is initially used. Adjust the water to a reasonable tempeature to avoid scalding..
  9. In order to drain off the water inside the inner container, it can be drained off from the exit port (Twist the thread screw of the exit port), and it can also be drained off from the one-way safety valve (Twist the thread screw off the one-way safety valve, and lift the drain handle upwards).
  10. If the flexible power supply cord is damaged, the special supply cord provided by the manufacturer must be used, and replaced by the profes- sional maintenance personnel.
  11. If any parts or components of this electric water heater are damaged, please contact the professional maintenance personnel for repair, and use the special spare parts and components provided by our company.

Maintenance

  1. Check the power supply plug and socket frequently to make sure that they have good, reliable contact and are well grounded without overheating.
  2. If the heater is not going to be used for a long time, especially in the regions with low temperatures (lower than 0℃), in order to prevent the heater being damaged due to the freezing of water in the inner container, the water inside the heater shall be drained away (refer to Item 9, Cautions of this manual for the method to drain away the water inside the inner container).
  3. The recommended water hardness for an optimum working performance of the water heater should not exceed 120 mg/l of CaCo3 (Calcium Carbon-ate). In case of exceeding this quantity, it is recommended to use alterna-tive decalcifying systems (You can check your local water hardness in the Water Board of you local Town Hall.) Should there be any failures due to the deposits originated by the water quality, will not be covered by the guar-antee.
  4. To guarantee the long-term durability and efficiency of your water heater, it is recommended to clean its inner tank and the deposits in the heating com-ponents on a regular basis.
  5. It is also recommended to check the magnesium anode periodically (minimum once a year or every six months depending on the waterhardness).
  6. If the magnesium anode of your water tank is worn out due to the deposits originated by the water quality, the After Sales Service will have to replace it by a new one. The cost of the materials of the replacement of the magne-sium anode will be covered within the guarantee period, however, the cost of the workforce or services for this replacement will not be included.
  7. It is recommended to clean the surface of the water heater with soapy water, never use abrasive products or solvents.
  8. During the guarantee period, the maintenance will be done by Teka´s Official After Sales Service. Any services undertaken by non-Teka Official After Sales services will be excluded from the guarantee.cata CTRS-50 REV SLIM Water Boiler-FIG10

Failures and treatment

Failures Reasons Treatment

The heating indicator

light is off.

|

Failures of the

temperature controller.

|

Contact with professional staff for repair.

No water coming out

of the hot water outlet.

| 1. The running water supply

is cut off.

2. The hydraulic pressure

is too low.

3. The inlet valve running water is not open.

| 1. Wait for restoration of running water supply.

2.  Use the heater again when the hydraulic pressure is increased.

3. Open the inlet valve running water.

The water temperature

is too high.

| Failures of the temperature control system.| Contact with professional staff for repair.

Water leak

| Seal problem of the joint of each pipe.|

Seal up the joints.

Wiring diagram

cata CTRS-50 REV SLIM Water Boiler-FIG9

Produce information with EU regulation

  • The electrical storage water heater CTRS-50 REV SLIM of the company Cata Electrodomesticos S.L. was tested with a declared load profile of the size “M”
    The product fulfills and corresponds to the requirements of the commission regulation standards (No 814/2013) for electrical storage water heater and achieved a water heating energy efficiency of ηwh=41.3%
    that correspond to the water heating efficiency class “B”
    In accordance with AnnexⅡ Enercy Efficiency Classes article 1 of the commission regulation (No 812/2013)
    The evaluation of the result of this report with respect of conformity with the related commission regulation (No 812/2013 and 814/2019) is only a part of the conformity assessment to achieve the ErP-Label.
    Electricity consumption Qelec, water heating energy efficiency ηwh and mixed water at 40℃(V40)
Description Parameter Value Unit
k-Value k 0.23
Smart control compliance smart 1
Smart control factor SCF 21.5 %
Conversion coefficient CC 2.5
Ambient correction term Qcor 0.137732
Referenct energy Qref 5.845 kWh
Useful energy content QH2O 7.318 kWh
Correction ratio of reference and useful energy Qref/QH2O 0.799 kWh
Daily electricity consumption (measured) Qtest_elec 7.143 kWh

Water temperature at the beginning of the 24h measurement

cycle

| T3| 72.0| ℃
Water temperature at the end of the 24h measurement cycle| T5| 69.9| ℃
Storage volume| Mact| 47| kg
Storage volume| Cact| 47| L
Daily electricity consumption (corrected)| Qelec| 8.829| kWh
Sequence of SMART tapping cycles used during the test| M/S/M/S/M
Useful energy content of the hot water drawn-off during smart period Qreference,H2O expressed in kWh:| Qreference,H2O|

26.012

|

kWh

Useful energy content of the hot water drawn-off during smart period Qsmart,H2O expressed in kWh:| Qsmart,H2O|

23.898

|

kWh

The weekly electricity consumption with smart controls| Qelec,week,smart| 29.020| kWh
The weekly electricity consumption without smart controls| Qelec,week| 36.980| kWh
Water heating energy efficiency| ηwh| 41.3| %
Annual Electricity Consumption| AEC| 1243| kWh
Water heating energy efficiency class| B
Water temperature without tapping| Tset| 63.6| ℃
Average water temperature of inlet cold water| θc| 11.1| ℃
Normalised value of the average temperature| θp| 60.6| ℃
Calculated volume that delivered hot water of at least 40℃| V40| 76| L

  • The electrical storage water heater CTRS-80 REV SLIM of the company Cata Electrodomesticos S.L. was tested with a declared load profile of the size “M”
  • The product fulfills and corresponds to the requirements of the commission regulation standards (No 814/2013) for electrical storage water heater and achieved a water heating energy efficiency of ηwh=39.0%  that correspond to the water heating efficiency class “B”
  • In accordance with AnnexⅡ Enercy Efficiency Classes article 1 of the commission regulation (No 812/2013)
  • The evaluation of the result of this report with respect of conformity with the related commission regulation (No 812/2013 and 814/2019) is only a part of the conformity assessment to achieve the ErP-Label.
  • Electricity consumption Qelec, water heating energy efficiency ηwh and mixed water at 40℃(V40)
Description Parameter Value Unit
k-Value k 0.23
Smart control compliance smart 1
Smart control factor SCF 38.1 %
Conversion coefficient CC 2.5
Ambient correction term Qcor -0.10732
Referenct energy Qref 5.845 kWh
Useful energy content QH2O 8.5238 kWh
Correction ratio of reference and useful energy Qref/QH2O 0.686 kWh
Daily electricity consumption (measured) Qtest_elec 14.177 kWh

Water temperature at the beginning of the 24h measurement

cycle

| T3| 71.0| ℃
Water temperature at the end of the 24h measurement cycle| T5| 70.6| ℃
Storage volume| Mact| 74| kg
Storage volume| Cact| 74| L
Daily electricity consumption (corrected)| Qelec| 9.745| kWh
Sequence of SMART tapping cycles used during the test| M/S/M/S/M
Useful energy content of the hot water drawn-off during smart period Qreference,H2O expressed in kWh:| Qreference,H2O|

32.610

|

kWh

Useful energy content of the hot water drawn-off during smart period Qsmart,H2O expressed in kWh:| Qsmart,H2O|

27.109

|

kWh

The weekly electricity consumption with smart controls| Qelec,week,smart| 35.020| kWh
The weekly electricity consumption without smart controls| Qelec,week| 56.580| kWh
Water heating energy efficiency| ηwh| 39| %
Annual Electricity Consumption| AEC| 1316| kWh
Water heating energy efficiency class| B
Water temperature without tapping| Tset| 64.7| ℃
Average water temperature of inlet cold water| θc| 10.6| ℃
Normalised value of the average temperature| θp| 59| ℃
Calculated volume that delivered hot water of at least 40℃| V40| 108| L

Description to ANNEX I

  1. supplier’s name or trade mark
  2. supplier’s model identifier
  3. the declared load profile, expressed by the appropriate letter and typical usage in accordance with Table 3 of Annex VII
  4. the water heating energy efficiency class of the model, determined in accordance with point 1 of Annex II
  5. the water heating energy efficiency in %, rounded to the nearest integer
  6. the annual electricity consumption in KWh in terms of final energy and/or the annual fuel consumption in GJ in terms of GCV, rounded to the nearest integer and calculated in accordance with point 4 of Annex VIII
  7. the thermostat temperature settings of the water heater, as placed on the market
  8. the daily electricity consumption Q elec in KWh, rounded to three decimal places
  9. the declared load profile, expressed by the appropriate letter in accordance with Table 1 of this Annex
  10. the mixed water at 40℃ V40 in litres, rounded to the nearest integer
  11. maximum temperature of the thermostat
  12. ‘out of the box-mode’ is the standard operating condition, setting or mode set by the manufacturer at factory level, to be active immediately after the appliance installation, suitable for normal use by the end-user according to the water tapping pattern for which the product has been designed and placed on the market
  13. the water heating energy efficiency in %, rounded to one decimal place
  14. All specific precautions for assembly, installation and maintenance are described in the operating and installation instructions. Read and follow the operating and installation instructions.
  15. All of the data that is included in the product information was determined by applying the specifications of the relevant European directives. Differences to product information listed elsewhere may result in different test conditions. Only the data that is contained in this product information is applicable and valid.

Import:
MULTIKOMPLEX BUDAPEST KFT.
a páraelszívók szakértője… 1995 óta
H – 1211 Budapest, Mansfeld Péter u. 27 (volt Bajáki Ferenc utca)
tel.: +(36-1) 427 0325, +(36-1) 427-0326; fax: +(36-1)427 0327
www.multikomplex.hu

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals