oasis CX Logix Controller Instruction Manual
- June 12, 2024
- Oasis
Table of Contents
- IMPORTANT WARNINGS & SAFETY INSTRUCTIONS
- GENERAL OVERVIEW
- SPECIFICATIONS
- MAINTENANCE
- HELPFUL HINTS
- CONTENTS
- TOOLS NEEDED
- POOL PREPARATION
- INSTALLING THE pH CONTROLLER
- NAVIGATING THE LCD pH MENUS ON YOUR SANITISER
- TROUBLESHOOTING
- SPARE PART NUMBERS
- WARRANTY
- TECHNICAL SUPPORT
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Oasis
CX Logix
INSTALLATION AND OPERATION MANUAL
For more details visit
oasisaquatics.com.au
sales@sunloverheating.com.au
Head Office
62 Parkhurst Dr
Knoxfield VIC 3180
T: 03 9887 2131
| New South Wales
Unit 2,10 Boden Rd
Seven Hills NSW 2147
T: 02 9838 0000|
Queensland
Unit 4, 8 Reichert Dr
Molendinar QLD 4214
T: 07 5679 6821
---|---|---
IMPORTANT WARNINGS & SAFETY INSTRUCTIONS
Important Warnings
This manual contains important information about the installation, operation,
and safe use of this product.
This information should be given to the owner and/or operator of this
equipment. When installing and using this electrical equipment, basic safety
precautions should always be followed. Failure to follow safety warnings and
instructions in this manual can result in serious injury and/or damage to your
equipment. Read and follow all warning notices and instructions which are
included in this manual.
- The pH controller case contains live components internally. There is a danger of electric shock if opened. If the power cord is damaged then it should be replaced by the manufacturer, their agent or similar qualified person, to avoid a hazard.
- The product shall be installed by a qualified person in accordance with AS/NZS 3000 wiring rules.
- The pH controller should be installed in the correct pool zone and connected to supply via a power outlet that is protected by a residual current device (RCD) having a rated residual operating current not exceeding 30mA. The power outlet should have a degree of protection suitable for the pool zone.
- To reduce the risk of injury, do not permit people (including children) with lack of experience and knowledge, to use this appliance unless they have been given supervision or instruction concerning use of the appliance.
- To reduce the risk of accidents or incidents, service on the unit should only be performed by a qualified pool service professional, after disconnecting it from the mains power supply.
- During the installation check the following:
- that the injector point pressure is lower than 150kPa (to ensure optimum flow)
- that the peristaltic pump’s acrylic front cover is correctly fitted
- that the suction tube is securely fitted in the acid container, with weight touching the bottom and the drum label is fitted on the outside of the container
- that the suction tube is fitted to the left side and the injector tube to the right
- that the injector valve o’ring is fitted between the valve and the CLEAR faucet tee and the BLACK lock nut is securely fastened
Important Safety Instructions
When mixing acid with water, ALWAYS ADD ACID TO WATER. NEVER ADD WATER TO
ACID.
Always wear the appropriate safety equipment specified by the acid supplier
when handling acid.
The system uses a 1 : 3 Acid : Water mix ratio (e.g. with a 20 litre drum add
15 litres water then 5 litres acid). It is important to use this mix for the
correct acid volume to be added.
DO NOT PLUG UNIT IN IF CARTON HAS BEEN WET.
When using the CX Logix:
- Observe all applicable local, state, and federal safety regulations.
- Take proper precautions with prescribed environmental and operational conditions.
- Consider chemical compatibility with all wetted materials.
GENERAL OVERVIEW
Congratulations on your recent purchase of your Oasis CX Logix controller.
Please take a moment to read through the entire manual before installing your
new unit. Your CX Logix controller must be installed and operated as
specified.
While every effort has been made to ensure that the information contained in
this guide is accurate and complete, no liability can be accepted for any
errors or omissions. Crystal Aquatic Systems reserves the right to change the
specifications of the hardware and software described herein at any time
without prior notice.
The pH in your swimming pool will slowly rise due to factors such as
alkalinity, the addition of fresh water and as sanitiser is produced in a
salt/mineral water system. A rise in pH reduces the effectiveness of the
sanitiser, so it is important to ensure that the pH remains in the correct
range.
The pH of the water can be lowered by the addition of hydrochloric acid – and
if your system has the optional pH control, this can be done automatically.
The CX Logix controller uses an algorithm to calculate how much how much acid
needs to be dosed to correct the pH.
Note: While the algorithmic pH control is effective, it does not measure
pH. pH testing should be undertaken manually on a weekly basis to ensure the
pH is correct.
SPECIFICATIONS
Volts & Amps Input (ac) | 220-245 V, 0.1 A |
---|---|
Total Power Consumption) | 13 W Motor, 20 W Max. |
Frequency | 50 Hz |
Output as Controlled by Sanitiser | 0-1000 ml per hour |
Rated Pressure | 350 kPa (optimum for injector is 150 kPa) |
Squeeze Tube | Tygon® Norprene® (Commercial spec) |
Motor Speed | 10 RPM |
Tubing Size | 4m long x 6mm diameter Clear Flexible PVC |
Power Cord | Approved piggy-back type |
Wall Mounting | Simple Click ON – Clip OFF |
Water Connection | CLEAR Acrylic Faucet Tee 50mm pipe |
Water Flow Rate (L/min) | 80-650 L/min |
Ingress Protection Rating | IP35 |
NOTE Certain specification may change without notice for reasons of improvement or better performance.
MAINTENANCE
Whilst this pH controller is built from the best engineered practices and
material, please ensure you regularly undertake the following basic
maintenance:
Injection Point on Injector Valve
Check the injection point periodically, by looking through the CLEAR faucet
tee, for build-up of solid matter at the end of the clear flexible PVC tubing.
This could only occur from contaminants in your acid container and the result
is a blockage hindering the flow of acid and reducing the life of the pump
tube and roller block. While unscrewing the BLACK lock nut, take care not to
lose the rubber O-ring.
Lubricate Squeeze Tube
Lubricate the pump squeeze tube every 3-6 months. Use a silicone-based
lubricant only as petroleum-based lubricants will cause damage to the tube and
rollers.
Replace Squeeze Tube
Depending on usage, the squeeze tube may need replacement after 1-2 years of
use. Before replacing, please ensure that the suction and injection tubes are
empty. To change the squeeze tube, please follow the instructions included
with the replacement kit. Only use our original sized commercial grade Tygon®
Norprene® tube as incorrect sizing will result in early failure of the Tri
Roller Block.
HELPFUL HINTS
- Read and keep your manual in a safe place.
- Test your swimming pool water on a regular basis and take your pool water sample to your local pool professional at least twice a month.
CONTENTS
TOOLS NEEDED
POOL PREPARATION
Please ensure that your pH is balanced to the recommended level for your
swimming pool surface.
Ideal pH Levels:
Concrete Pools | 7.4 – 7.6 |
---|---|
Fibre glass and Vinyl Pools | 7.0 – 7.2 |
A pH of 8.0 makes your chlorine only about 26% efficient so that is why it is
critical to keep your pH in range. A correct pH level must be maintained to
prevent problems such as black spot, staining, cloudy water etc. An incorrect
pH level can damage the surface finish and walls of your pool.
When pH is high you can add Hydrochloric Acid to lower the pH. When pH is low
you can add sodium bicarbonate (soda ash) to increase the pH.
INSTALLING THE pH CONTROLLER
Installation Diagram
1 Pool Filter
4 Pool Sanitiser
7 Injection with Tee| 2 Heat Pump
5 Cell Housing
8 Suction with Drum weight & label| 3 Pool Pump
6 CX Controller
9 PVC Flexible Tube 6m
---|---|---
STEP 1 Remove the contents from the box and carefully plan all steps
using the installation diagram, and by reviewing the steps below.
STEP 2 Position the CX Logix controller box as indicated in the
installation diagram, ensuring it is NOT too close to other equipment or power
outlets, but close enough to the Oasis Chlorinator power supply so the piggy-
back power cord can plug in to its socket outlet.
STEP 3 Attach the CX Logix controller to the wall by removing the simple
“Click ON – Click OFF” wall mounting bracket that is attached to the
controller case. Use the wall plugs and screws provided.
This unique design keeps the controller case unexposed to any possible water entry.
STEP 4 Fit the CLEAR faucet tee c/w injection valve to the pool water
line, avoiding high pressure areas (i.e., after the pump, filter, and prior to
heat pump). It can be installed prior to the cell housing (or after if
needed).
STEP 5 Cut and connect a length of clear flexible PVC tube that will
reach from the outlet at the base of the peristaltic pump (right side) to the
injection valve, that is mounted in the CLEAR faucet tee, using the tube nut
to secure the tube.
STEP 6 Do not cut the other length of clear flexible PVC tube yet. Place
the acid drum (with the required mix) in the required position, in a
ventilated area, preferably not near this or other pool equipment (at least 2m
or more away), as the acid is corrosive and equipment damage will occur.
The system uses a 1 : 3 Acid : Water mix ratio (e.g. with a 20 litre drum add
15 litres water then 5 litres acid). It is important to use this mix for the
correct acid volume to be added.
Important Safety Instruction: When mixing acid with water, ALWAYS ADD ACID TO
WATER. NEVER ADD WATER TO ACID. Always wear the appropriate safety equipment
specified by the acid supplier when handling acid.
STEP 7 Pass this clear flexible PVC tube through the drum label and a
6.0mm hole in the acid drum vent cap. Connect the clear flexible PVC tube to
the suction valve that is mounted to the drum weight, using the tube nut to
secure the tube. Before placing the tubing into the drum, measure the tubing
against the outside of the drum and measure the feed tubing so that there is
sufficient tubing. Lower the drum weight into the acid drum and screw on the
drum cap.
STEP 8 Connect the pH Signal Cable with 5 Pin Plug to the Oasis CX
Premium Salt & Mineral Chlorinator programming cable port. This is where the
signal from the chlorinator comes from to turn the pH controller ON & OFF.
STEP 9 Connect the piggy-back power cord to the AC socket outlet of the
Oasis CX Premium Salt & Mineral Chlorinator and the pool pump plugs in to the
other end of the piggy-back socket.
STEP 10 Start up your pool pump and check the system for any leaks.
Repair any such issues.
STEP 11 Prime the acid feed lines and finalise run settings using the
menus below.
NAVIGATING THE LCD pH MENUS ON YOUR SANITISER
As fresh water is added, or chlorine is produced the pool pH will slowly
increase. This can be offset by adding small doses of acid to the pool
automatically. This pH controller uses a maintenance free algorithm that
calculates the amount of acid, per dose, that is needed to maintain the pH.
Initially it is based on the size of your pool, but through your testing, it
can smartly be adjusted to make it truly near-maintenance free for you the
owner.
NOTE: It is important that the system is initially adjusted based on pH
result to suit your pool and that pool pH is still checked regularly.
Accessing the pH Control Menu
These are the menus on the Oasis CX Premium Salt & Mineral Chlorinator On the
power pack press OK to access the Main Menu system and use the +/- buttons to
scroll through the menu until the LCD reads ‘pH Control Mode’.
Press OK to enter this mode.
13 Winter / Blanket
14 pH Control Mode
[+] UP [-] DN [OK] ENTER
pH Control Mode – Turning on the pH Mode
The default setting on the chlorinator is for the acid dosing system to be
‘OFF’.
This needs to be turned to ‘ON’ to operate the CX Logix.
To turn ON the acid dosing of the pH controller, enter the ‘pH MODE’ menu from
the ‘pH Control Mode’ menu explained in 10.1
Using the [+], [-] & [OK] button change the selection from OFF to ON.
pH CONTROL MODE
pH Mode: OFF
[+] or [-] to change
[OK] ENTER [<] EXIT
pH1 Run Time – How the dosing system works
The default setting on the chlorinator is for the acid dosing system to be ON.
This ‘pH1 Run Time’ is programmed automatically when setting up the volume of
the swimming pool in the chlorinator. The system calculates how many minutes
per day your pH controller should run based on the volume of your pool, and
this can be manually changed.
To adjust the run time, enter the ‘pH1 Run Time’ menu from the ‘pH Control
Mode’ menu explained in 10.1, using the [+], [-] & [OK] button.
pH CONTROL MODE
pH1 Run Time
pH2 Demand or Prime
[+] UP [-] DN [OK] ENTER
The LCD will now show ‘On Time: —- min/day’. Press [+] or [-] to adjust the ON Time in min/day. Pressing [OK] saves the required run time and returns to you to the main menu. Saving this Run Time will result in the time being saved as the new default running time of the unit. Entering 0 min/day means the system will not run at all.
pH1 RUN TIME
ON Time:—- min/day
[+] or [-] to change
[OK] SAVE [<] BACK
pH2 Demand or Prime – Add acid manually or prime clear flexible PVC tubes
The ‘pH2 DEMAND or PRIME’ quantity can be manually adjusted from 0 – 5000 ml.
The default reading is always 100 ml. This function is useful for:
- Priming tubes after an acid drum change.
- Adding the required acid from your acid demand test.
IMPORTANT: Enter the exact amount from your test result in ml (e.g.,
500ml) and the system automatically adds 4 times that amount, thereby allowing
for the 1:3 ACID: WATER mix ratio in the acid drum.
To enter a required amount of acid in mL, enter the ‘pH2 Demand or Prime’ menu
from the ‘pH Control Mode’ menu explained in 10.1, using the [+], [-] & [OK]
button
pH CONTROL MODE
pH1 Run Time
pH2 Demand or Prime
[+] UP [-] DN [OK] ENTER
The LCD will now show ‘Acid Demand: 100 ml’. Press [+] or [-] to adjust the
quantity of acid required in millilitres (ml). Pressing [OK] saves the
required quantity, the peristaltic pump starts turning and the ml reading
starts counting down.
You can adjust the quantity in this menu if you wish or you can press [<] and
return to the chlorinator default display screen. If the lines are primed, you
can stop the peristaltic pump by entering a reading of ‘0 ml’.
pH DEMAND OR PRIME
Acid Demand: xxxx ml [+] or [-] to change [OK] SAVE [<] BACK
Turning OFF the CX Logix
Enter the pH Control Mode menu on the Oasis CX Premium Salt & Mineral
Chlorinator.
On the power pack press OK to access the Main Menu system and use the +/-
buttons to scroll through the menu until the LCD reads ‘pH Control Mode’.
Press OK to enter this mode.
13 Winter / Blanket
14 pH Control Mode
[+] UP [-] DN [OK] ENTER
If the setting on the chlorinator has previously been set for the acid dosing
system to be ‘ON’ and the system needs to be turned ‘OFF’ use the following
procedure.
To turn OFF the acid dosing of the pH controller, press [OK] on the ‘pH mode:
ON’ menu from ‘pH Control Mode’ menu explained in 10.1.
Then use the [+] or [-] button to change the selection from ON to OFF and
press [OK] to save.
pH CONTROL MODE
pH Mode: ON
[+] or [-] to change
[OK] SAVE [<] EXIT
TROUBLESHOOTING
If you suspect for any reason your Oasis CX Logix Controller is not performing or running as it should be, here are some handy troubleshooting tips that may assist you.
Fault Indication | Potential Cause | Remedy |
---|---|---|
6.1 pH controller is not turning on | pH control mode has not been turned on. |
See Manual Section 10.1
pH controller power cord not plugged in| Check that power cord is plugged in
to the sanitiser AC socket outlet
No demand for it to turn on from the sanitiser| The demand takes place each
day at the start of T1 ON time or 8am (if no T1 ON time set).
Check if signal for pH required is ON.
Demand signal is present but
peristaltic pump is not turning| Contact your service agent
6.2 Everything displays correctly but pH level is not changing when testing
pool water| Acid drum is low or empty| Check acid level and replenish if
necessary
6.3 pH controller is not running when sanitiser is in auto mode| The pH
controller has already operated in today’s timer cycle| The pH controller will
not run again if it has
already completed its automatic cycle
6.4 pH controller is running but the pool pump is not on| Pump is not plugged
in or there is a problem with flow| The system should automatically stop when
the pool pump stops but check that there is not a closed valve and that all
pool equipment is plugged in and working
properly
6.5 pH Controller tri-roller is turning but acid is not pumping| Air leaks on
the squeeze tube, injector tube or suction tube due to potential breaks| Check
the tubes for damage or leaks and repair such or replace tubes
Excessive wear on the squeeze tube| Order a replacement squeeze tube kit and
replace the tube
Excessive wear on the tri-roller black| Order a replacement tri-roller block
assembly and replace the entire tri-roller block
6.6 Water flow returning from pool to the acid drum| In the unlikely event of
this happening,| it can only be one of two things:
Worn/damaged injector sleeve| Replace the injector sleeve
Worn tri-roller block| Replace the tri-roller block
6.7 pH level in the pool is too high or too low| Incorrect pH run time| Adjust
pH run time to suit as per procedure in 10.2
Incorrect ACID:WATER mix| The system uses a 1:3 mix ration.
Ensure you have this required mix
Incorrect ACID DEMAND amount entered| You should only enter the required acid,
not thew mix. So, if you need 500ml only enter this. The system allows for the
1:3 mix.
SPARE PART NUMBERS
POWER PACK
| CODE| Description
---|---|---
1| N01185| CLEAR Faucet Tee 50mm x 3/4″ BSP
2| N01186| pH Injector O’Ring Seal EPDM BLACK
3| N01339-2| pH Controller Front Cover – pH LOGIX CAS
4| N01340| Acrylic Cover – pH Controller CLEAR
5| N01350| pH Drum Weight
6| N01353| pH Tri Roller Block pH-1 (Assembled)
7| N01355| pH Squeeze Tube Kit BLACK c/w Adaptors, Nuts, Clamps & Lube
8| N01357| pH Motor – 240Vac 13W 10rpm
9| N01360| pH Clear Flexible PVC Tubing, CLEAR, OD=6.0mm
10| N01361| pH Drum Label
11| N01362| PCB – pH LOGIX Main PCB
12| N01364| Power Cord – pH c/w Piggyback Socket
13| N01367| pH Non-Return Injector Valve c/w Sleeve & Tube Nut
14| N01368| pH Suction Valve c/w Tube Nut
WARRANTY
THIS EQUIPMENT HAS BEEN MANUFACTURED AND TESTED TO THE HIGHEST STANDARD AND
ACCORDINGLY CARRIES THE FOLLOWING WARRANTY.
Your Oasis CX Logix controller is covered by a twelve (12) month warranty
against defects in workmanship and materials if used for its intended purpose
and maintained according to instructions.
This warranty is limited to repair or replacement, depending on the problem of
the product.
The customer is liable to return the product to Oasis Aquatics. Please ensure
proper packaging so that no additional damages occur during transport.
Should you need to lodge a warranty request, ensure to include:
Product serial number
Purchase date
Type of failure/s
The Warranty is void under the following circumstances:
- Water damage from external sources
- Insect infestation or penetration by dust, sand or other foreign particles inside the controller
- Equipment that has been misused, neglected, damaged, repaired without authorisation or altered in any way
- Installation is carried out incorrectly by any person other than a person authorised by us to do so
- Damage beyond our control
This warranty is not transferable under any circumstance. Keep your original
purchase invoice and serial number in a safe place.
Oasis Aquatics shall have no liability for incidental or consequential
damages. No person is authorized to make any representation or warranty on
behalf of Oasis Aquatics other than what is stated here.
This limited warranty is the sole and complete warranty for Oasis Aquatics and
shall be limited to the cost of the meter.
TECHNICAL SUPPORT
For all warranty enquiries please contact your local distributor or contact Sunlover Heating directly and we will either direct you to your nearest authorised repairer or assist you.
ASIS AQUATICS
Ph: 1800 815 913
Website: oasisaquatics.com.au
Email: info@oasisaquatics.com.au
DISCLAIMER
Information in this guide is intended to provide general information on a
particular subject(s) in good faith and is not an exhaustive treatment of such
subject(s). Its use is beyond the control of the author, contributor,
publishers and distributors and should not be relied upon without consulting
your local professional for comprehensive advice.
This guide includes subject(s) that should only be performed by or under the
direction and advice of your local professional and under no circumstances
should the guide be used as a substitute for such professionals.
No representations or warranties are made that the content, advice and
recommendations in this guide are current, free from errors or omissions, or
appropriate for the user’s circumstances or abilities.
No liability or responsibility is accepted for any loss suffered as a result
of any user’s reliance on such content.
A part of the
Victoria
62 Parkhurst Drive
Knoxfield VIC 3180
Australia
T: 03 9887 2131| New South Wales
Unit 2, 10 Boden Road
Seven Hills NSW 2147
Australia
T: 02 9838 0000| Queensland
Unit 4, 8 Reichert Drive
Molendinar QLD 4214
Australia
T: 07 5679 6821
---|---|---
oasisaquatics.com.au
info@oasisaquatics.com.au
CX Logix Operation MANUAL – Updated July 2022
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>