THERMO-X-AIR is a high-quality heating unit manufactured by THERMOLEC LTD. It is designed to provide efficient heating and ventilation for various applications. Please read the installation instructions carefully before proceeding with the installation.
Mechanical Installation
The THERMO-X-AIR unit comes with the following components:
- Damper (optional)
- Thermal cutout
- Reversible Airflow
- Washable filter
- Fan
During installation, please keep the following points in mind:
- Do not install elbows closer than 8 inches to the inlet or the outlet of the unit.
- Use 6” round insulated duct for the inlet connection and uninsulated for the outlet. Minimize the use of elbows.
- Attach the unit to a suitable support. This model is small enough to be located between standard 16 spaced floor joists. Always allow a minimum 1/2” clearance above the heater. To simplify installation, attach the mounting bracket and then hook the top of the unit on the bracket and only screw in the bottom flange.
Electronic Controller
The THERMO-X-AIR unit features an electronic controller thatadjusts the heating capacity to the volume of air and shuts down the heater when there is no air flow. The minimum amount of air required (in cubic feet per minute) to operate the unit is given in the last column of the table on side 2 (CFM).
Product Usage Instructions
- Ensure that the THERMO-X-AIR unit is properly installed according to the mechanical installation instructions provided.
- Connect a suitable power source to the unit. The unit isavailable in both 120V and 240V options.
- Set the desired temperature using the temperature set point adjuster on the unit.
- Monitor the airflow using the air flow sensor and ductsensor. Ensure that the minimum required air flow (CFM) ismaintained for proper operation.
- If an optional damper is installed, adjust it accordingly to control the airflow.
- Regularly clean the washable filter to ensure efficient operation and prevent dust buildup.
- In case of any issues or malfunctions, refer to the troubleshooting section of the user manual or contact THERMOLEC LTD. for assistance.
Installation instructions
Please read instructions carefully before installation
Mechanical Installation.
- The direction of airflow is reversable by simply rotating the unit 180° in the horizontal position only. This is possible due to the automatic cutouts on the top and bottom of the unit.
- Do not install elbowscloser than 8 inches to the inlet or the outlet of the unit.
- Use 6” round insulated duct for the inlet connection and uninsulated for the outlet. Minimize the use of elbows.
- The electronic controller ajust the heating capacity to the volume of air and shuts down the heater when there is no air flow. The minimum amount of air required (in cubic feet per minute) to operate the unit is given in the last column of the table on side 2 (CFM).
- Attach the unit to a suitable support. This model is small enough to be located between standard 16” spaced floor joists. Always allow a minimum 1/2” clearance above the heater. To simplify installation, attach the mounting bracket and then hook the top of the unit on the bracket and only screw in the bottom flange.
Electrical Installation
NOTE: When the Room Control AND a current sensor is connected to the
D22-TFS the current sensor will take priority in switching on the unit.
- Please conform to all local and national electrical codes for wiring. The system should be supplied by a separate cable, of appropriate gauge, and with appropriate protection. Please refer to the following table.
- Install the one touch room control in an appropriate location on the wall according to the user’s choice.
- After installing and wiring the system, use the potentiometer to adjust the desired temperature and the fan speed control to adjust the air volume.
- A connection to drive simultaneously a 120VAC max. 3 amps. exhaust fan is supplied to be used if required.
Remember: For technical assistance, please use our free help line: 1-800-336-9130
-
Automatic Reset Thermal Cut-outs (on top and bottom)
Safety feature preventing overheating; will reset automatically after cool- off. -
Washable Filter
Easy access filter. -
Enclosure
Corrosion resistant galvanized steel. -
Fan
High quality tube axial fan with ball bearings for lowest noise and longest life. -
Air Flow Sensor
Modulates the heating capacity according to the quantity of air flowing through
the heater. -
Manual Reset Thermal Cut-out
Additional safety feature which prevents the frame from overheating. -
Temperature Sensor
Controls the heater proportionally to maintain the pre-set air temperature in the duct. -
Open Coil Elements
Made of the highest grade nickel-chrome resistance wire, they will not age or oxidize, thus assuring longer heater life. -
Fan Speed Control
To adjust the air volume. -
Built-in Electronic Temperature Controller and Sensor
Proportionally modulates the heating load to match the exact capacity required, thus minimizing operating cost. -
Round Collars
Simplifies the installation and considerably reduces field labor. -
Connection for Exhaust Fan Supplied
120VAC up to 3 amps. max. output to drive simultaneously an exhaust fan when required. -
Damper
Automatically opens when the heater is in operation.
- One Touch Room Control Allows full or intermittent ventilation.Pilot lights indicate the selected mode
Room Controller Instructions
MINI FRESH AIR MAKE-UP – THERMO-X-AIR
Field of Application:
- Fresh Air Make-up for residential houses, condos or apartments. Scope:
- Standard house from 1800 to 2000 square feet.
- An airflow of 60 cubic feet per minute (CFM) is required for a minimum of 2.0 KW.
Operating Procedure:
- Make sure the fan is adjusted at 60 CFM.
- Adjust the output temperature of the THERMO-X-AIR on the D22-TFS module.
- Use the push button Room Controller (installed near the entrance door) for either a continuous or intermittent operation, depending upon how many air changes you require.
- For a dry contact operation (on-off) please contact Thermolec.
N.B.
For homes with a surface area of more than 2000 square feet, the required
airflow is 90 CFM for a minimum of 3.0 KW. Connect the bathroom fan to the F F
terminals in the THERMO-X-AIR. The operation is exactly the same as the 60 CFM
unit.
Push Button Room Controller
The buttons control three functions: Stop, Continuous Ventilation and
Intermittent Ventilation. A pilot light confirms the chosen mode.
Function 1: Stop
Function 2 Continuous Ventilation
Function 3 Intermittent Ventilation
- 2060 Lucien-Thimens Montreal, Quebec H4R
- 1L1 Tel: 514-336-9130 Fax: 514-336-3270 The Leader in Modulated Heating
- www.thermolec.com