brandywine communications QFS-106 Frequency Standard User Guide

June 12, 2024
brandywine communications

brandywine communications QFS-106 Frequency Standard

Product Information

  • Product Name: Frequency Standard QFS-106
  • Model Number: QFS-106
  • Part Number: 0150060XX
  • Revision: E
  • Date: July 2023
  • Manufacturer: Brandywine Communications
  • Address: 1153 Warner Ave
  • Contact Number: (714) 755 1050
  • Fax Number: (714) 755 0175
  • Website: http://www.brandywinecomm.com

Product Usage Instructions

Unpacking:

Follow the steps below to unpack the product:

  • Open the packaging carefully.
  • Remove the product from the packaging.
  • Ensure all included accessories and components are present.

Installation:

Follow the steps below to install the product:

  • Select a suitable location for the product.
  • Place the product on a stable surface.
  • Ensure proper ventilation around the product.

Connections:

Follow the steps below to make connections:

  • Refer to the provided diagrams to identify the appropriate ports.
  • Connect the necessary cables to the corresponding ports.
  • Ensure all connections are secure.

Powering the QFS-106:

To power the QFS-106, follow the steps below:

  • Ensure the product is connected to a suitable power supply.
  • Press the power button to turn on the QFS-106.

Loss of Input Signal:

If there is a loss of input signal, follow the steps below:

  • Check the input connection for any loose cables.
  • Ensure the input signal source is functioning properly.
  • Contact technical support if the issue persists.

Loss of Output Signal:

If there is a loss of output signal, follow the steps below:

  • Check the output connection for any loose cables.
  • Ensure the output signal destination is capable of receiving the signal.
  • Contact technical support if the issue persists.

Calibration:

To calibrate the product, refer to the calibration procedure provided in the user manual.

Brandywine Communications 1153 Warner Ave
(714) 755 1050
(714) 755 0175
http://www.brandywinecomm.com

INFORMATION TO THE USER FOR CLASS A DIGITAL DEVICE

WARNING: This equipment has been tested and found to comply with the limits for Class A digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction’s manual, may cause interference to radio communications. Operation of this equipment in a residential area is likely to cause interference in which case the user will be required to correct the interference at his own expense.
The user is cautioned that changes and modifications made to the equipment without approval of the manufacturer could void the user’s authority to operate this equipment.

Revision History

REVISION DATE COMMENTS ECO NUMBER
NC 10-26-04 Original release of QFS-106 user guide.
A 12-14-04 Revision of the rear panel and mechanical outline drawings.
B 08-03-05 Revision of Section 3.1.
C 02-14-11 Illustrations of fuse installation
D 10-24-17 Corrected Fuse Ratings
E 07-06-23 Added drawings directly into document file ECO12672

Specifications

I/O and Environmental (Rear Panel)

SPECIFICATION DESCRIPTION
Internal Reference Oscillator OCXO Stability
OCXO Aging 5 x 10-8 per year
Rubidium Stability ±1 x 10-10 at 0 to 50°C
Rubidium Aging 5 x 10-11 per month
Reference Input Label
Number of Reference Inputs 1 Input
Frequency 10 MHz Standard
Level 1 Vrms into 50 ohm
Connector BNC
Reference Output (Buffered from Reference Input) Label
Number of Reference Outputs 1 Output
Frequency 10 MHz Standard
Level 1 Vrms into 50 ohm
Distortion < 33 dBc
Connector BNC
Outputs Label

Output 3 (J3), Output 4 (J4),

Output 5 (J5), and Output 6 (J6)

Number of Frequency Outputs| 6 Buffered Outputs
Frequency| 10 MHz Standard
Level| 1 Vrms into 50 ohm
Distortion| < 33 dBc
Connector| BNC
Phase Noise at 10 MHz| 1 Hz| -90 dBc/Hz
10 Hz| -110 dBc/Hz
100 Hz| -140 dBc/Hz
1000 Hz| -150 dBc/Hz
10000 Hz| -157 dBc/Hz
Environmental| Temperature| -30 to +60°C
Humidity| 95% non-condensing
Fuse| VDC Model| 400 VDC and 4A
VAC Model| 115/230 VAC and 250mA
Power| VDC Power Supply| 09 – 18 VDC (12V Nominal)
18 – 36 VDC (28V Nominal)
36 – 72 VDC (48V Nominal)
VAC Power Supply| 115/230 VAC
Power Connection| VDC Connector| DC Connector
VDC Connector 2 Pin| Pin A -> Positive
Pin B -> Negative
VAC Connector| AC Connector
Dimension| Length (Rack Mount & Chassis)| 19.00” and 17.00”
Height| 1.720”
Width| 6.150”
Weight| Weight| Typically 3 lbs

Switch and Indicator (Front Panel)

SWITCH/INDICATOR COLOR DESCRIPTION
POWER SWITCH –– Used to switch the unit on and off
POWER LED GREEN Indicates that the unit has primary power
OUTPUT MONITOR 1 LED GREEN Indicates that Output 1 is present
OUTPUT MONITOR 2 LED GREEN Indicates that Output 2 is present
OUTPUT MONITOR 3 LED GREEN Indicates that Output 3 is present
OUTPUT MONITOR 4 LED GREEN Indicates that Output 4 is present
OUTPUT MONITOR 5 LED GREEN Indicates that Output 5 is present
OUTPUT MONITOR 6 LED GREEN Indicates that Output 6 is present
PLL LED RED Indicates that the unit is in power up mode or not locked to the

reference input
GREEN| Indicates that the unit is phased locked to the reference input
RB LOCKED LED| GREEN| Indicates that the rubidium oscillator has reached resonance lock if installed
CALIBRATE (POTENTIOMETER)| ––| Used to calibrate the oscillator

Unpacking and Installation

Unpacking

Carefully remove the QFS-106 from the shipping carton. The following items should be included in the shipment:

  • 1 QFS-106
  • 1 user guide
  • 1 power cord
  • 1 power mating connector (DC voltage only)

Note the power connection on the rear of the QFS-106 chassis. Please take note of the voltage displayed near this power connection.
If the AC or DC voltage setting is incorrect, use a small screw driver to remove the fuse holder. Reverse the fuse holder and re-insert the fuse holder, making sure that the correct AC or DC voltage is now displayed on the rear panel of the QFS-106.

brandywine communications QFS-106 Frequency Standard-
FIG1

Use the supplied power mating connector for the QFS-106 unit (DC voltage only). The user must connect the wires to the connector as shown in the table below.

DC MODEL DESCRIPTION
Pin A Positive input voltage
Pin B Negative input voltage
Mating Connector Amphenol 97-3106A-10SL-4S
Strain Relief Amphenol 97-3057-1004-1

Installation

The QFS-106 may be bolted directly onto a 19” rack mount enclosure.

Connections
Connect the power source to the QFS-106. Now connect the input reference signal and output reference signals to the appropriate connectors on the rear panel of the QFS-106. The Reference Output connector may be used when daisy- chaining multiple QFS-106 units.

brandywine communications QFS-106 Frequency Standard-
FIG2

When daisy-chaining multiple QFS-106 units, these units should be connected as shown in Figure 1. This configuration ensures that all outputs are accurately locked to a common reference with minimal injection of the phase lock loop noise.

Operation

Powering the QFS-106
Once all the connections to the QFS-106 have been made, apply power to the unit by switching the power switch to the on position. The power switch is located on the rear panel of the unit. The Power LED and Output Monitor LEDs (1 – 6) on the front panel of the unit will illuminate green.
Please note that units fitted with the quartz oscillators will take approximately five minutes to warm up and these units will reach full accuracy after twenty-four hours. Units fitted with the rubidium oscillators will take approximately ten minutes to warm up.

Loss of Input Signal
The PLL LED illuminates green when an input signal is present on the Reference Input connector on the rear panel of the unit. If the reference input fails, the front panel PLL LED will extinguish.

Loss of Output Signal
The Output Monitor LEDs (1 – 6) illuminate green when output signals are present on the Outputs connectors on the rear panel of the unit. If one or more outputs fail, the front panel Output Monitor LEDs (1 – 6) will extinguish.
Please note that a short circuit on the output cable may not always trigger the output alarm.

Calibration

The QFS-106 is a free running standard that requires periodic recalibration. The unit must be calibrated against a frequency standard that is at least ten times more accurate than the oscillator fitted in the QFS-106 unit. Therefore OCXO oscillator units must be calibrated against a rubidium reference. Rubidium oscillator units must be calibrated against a cesium frequency standard or GPS disciplined rubidium. The front panel mounted potentiometer is used to adjust the frequency of the QFS-106 unit. The table below describes this calibration.

OUTPUT POTENTIOMETER OUTPUT LEVEL ADJUSTMENT
Calibrate 20 turn potentiometer (front panel) Frequency standard calibration
Output 1 10 turn potentiometer (rear panel) 7 – 13 dBm
Output 2 10 turn potentiometer (rear panel) 7 – 13 dBm
Output 3 10 turn potentiometer (rear panel) 7 – 13 dBm
Output 4 10 turn potentiometer (rear panel) 7 – 13 dBm
Output 5 10 turn potentiometer (rear panel) 7 – 13 dBm
Output 6 10 turn potentiometer (rear panel) 7 – 13 dBm

Diagrams

FIGURE DESCRIPTION
1-Page 13 QFS-106 Front Panel (AC and DC Models)
2-Page 14 QFS-106 Rear Panel (AC Model)
3-Page 15 QFS-106 Rear Panel (DC Model)
4-Page 16 QFS-106 Mechanical Outline (AC Model)
5-Page 17 QFS-106 Mechanical Outline (DC Model)
6-Page 18 Opened fuse housing (AC Model)
7-Page 19 Fuse being removed (AC Model)
8-Page 20 Detail of fuse installed (AC Model)

Front Panel Drawing

brandywine communications QFS-106 Frequency Standard-
FIG3

Rear Panel Drawing (AC Model)

brandywine communications QFS-106 Frequency Standard-
FIG4

Rear Panel Drawing (DC Model)

brandywine communications QFS-106 Frequency Standard-
FIG5

Mechanical Outline Drawing (AC Model)

brandywine communications QFS-106 Frequency Standard-
FIG6

Mechanical Outline Drawing (DC Model)

brandywine communications QFS-106 Frequency Standard-
FIG7

Opened Fuse Housing (AC Model)

brandywine communications QFS-106 Frequency Standard-
FIG8

Fuse Being Removed (AC Model)

brandywine communications QFS-106 Frequency Standard-
FIG9

Detail of Fuse Installed (AC Model)

brandywine communications QFS-106 Frequency Standard-
FIG10

Documents / Resources

| brandywine communications QFS-106 Frequency Standard [pdf] User Guide
0150060XX, QFS-106 Frequency Standard, QFS-106, Frequency Standard
---|---

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals