RADIANT IDP-113 Roof Clip Aluminum Heat Instruction Manual
- June 12, 2024
- Radiant
Table of Contents
SOLUTIONS COMPANY
v.10-21
IDP-113 ROOF CLIP
INSTALLATION MANUAL
DESCRIPTION
The IDP-113 Roof Clip can be used to secure HeatTapePro–and various other brands of self-regulating heat cable–to a variety of roofing materials including asphalt shingle roofs, standing seam metal roofs and rubber membrane roofs. Seal nails or screws used with this clip with MKS-1022-1 butyl pads (preferred) or caulk with appropriate material depending on substrate (i.e., asphalt shingle, metal, etc.).
TOOLS REQUIRED
- Hammer
- Putty Knife
- Pliers
- Caulk Gun (if MKS-1022-1 butyl pads are not being used)
SUPPLIES REQUIRED
- Butyl pads
- Methacrylate Adhesive (Metal Surfaces )
- Bonding Adhesive (Rubber membrane roofs)
- Silicone (Asphalt shingle roofs)
INSTALLING CLIPS ON ASPHALT SHINGLES
OTHER METHODS
IDP-113 Heat Cable Roof Clips may be installed in many orientations on the
roof. They may need to be nailed or screwed on top of the roofing under
certain circumstances, such as at the bottom of a tracing pattern, Fig 1.
As an alternate to using butyl pads, apply a large dot of silicone to the
roof, Fig. 2. OTHER INSTALLATION DETAILS ASPHALT ROOF INSTALLATIONS
Point ‘A’, the width between each tracing pattern should be 24” for most
standard heating cable installations. Point ‘B’ is the tracing pattern height,
which changes project to project depending on the eave depth. Extra clips may
be used as necessary in areas where extra stress may be put on the heat cable
system. Refer to heat cable manufacturers installation instructions for
specifics. METAL ROOF INSTALLATIONS
The IDP-113 Roof Clip can be installed on metal roofs using methacrylate
adhesives. Clean the area on the metal thoroughly before installing the clip
to ensure a good adhesive bond. Place clip on the prepared surface and press
down until the adhesive flows through the holes. Do not trim back the adhesive
as the excess flow through helps hold the clip. Allow adhesive to cure per
manufacturer’s specifications before installing heating cable.
ADDITIONAL INSTALLATION DETAILS WARNING
IDP-113 Heat Cable Roof Clips should be installed in accordance with the heat
cable manufacturers recommendations. Follow all design, installation, assembly
and test instructions carefully. This product must be installed by a qualified
person in accord- ance with this installation handbook and with the National
Electric Code (U.S.) as applicable. All electric connections must be made by a
qualified electrician according to the electrical and building codes effective
in your region. Do not use IDP-113 Roof Clips for installation on slate or
tile roofs as damage may occur to roof material. Consult roofing manufacturer
for components approved for use on specific roofing materials.
For more information visitwww.radiantsolutionscompany.com
References
Read User Manual Online (PDF format)