VIZULO Stone Classic Emergency LED Luminaire Instruction Manual

June 4, 2024
VIZULO

VIZULO Stone Classic Emergency LED Luminaire Instruction Manual
VIZULO Stone Classic Emergency LED Luminaire

Surface mounting

Surface mounting

Surface mounting
Surface mounting
Surface mounting
Surface mounting
Surface mounting
Surface mounting

Dimensions

Dimensions

Netto Weight

Netto Weight

Ambient temperature range

Ambient temperature range

Install LED luminaire only in a clean room using gloves!

Diffuse cover may accumulate small electrostatic charges that makes it susceptible to dust and other small particles;
It should only be cleaned using dry microber cloth or compressed air duster.

Installation and using instruction

Safety iconWARNING!

  • Do not touch LED modules!
  • Do not put any tools or other items on LED modules!
  • In case any LED is physically damaged (example shown below) the warranty is void.
    LED modules

Energy efficiency class of contained light source(s)

  CRI
80 90
CCT 2200
2700 E
3000 E
4000 E
5000 E
5700 E
6500 E

Emergency lighting description

LED status indicator

The LED status indicator shows whether:

  • The system is in charging mode
  • Batteries are fully charged
  • A system error has occurred

LED indicator
(color / flashing)| Error condition| Cause| Solution
---|---|---|---
Green / no|  | System OK, battery fully charged|
Green / slow|  | System OK, battery is charging, not full|
Green / fast|  | System OK, recently tested (< 5 days)|
RED / no| Battery voltage too high| No battery connected| Connect a battery
RED / no| Battery voltage too low| Wrong or bad battery connected| Replace battery
RED / fast| Output voltage too low| Wrong LED load connected| Connect a right load and perform a functional test
RED / fast| Output voltage too high| Wrong LED load connected| Connect a right load and perform a functional test
RED / slow| Too short time during duration test| Battery end of life| Replace battery and perform a duration test.

Test switch

An optional test switch can be used to:

  • Initiate functional test as long as switch pressed: press 0 < time < 10 s
  • By entering the functional test the previous error (if available) will be cleared.
  • Initiate duration test: press > 10 s
  • In manual test mode, the battery and LED load will be checked. If any error occurs, corresponding error bit (for DALI drivers) will be set and the luminary will go into charge mode regardless of the test button pressing.
  • Pressing the test button in Emergency mode or during a self-test mode will not have any effect.

Charging
After first installation (and after each emergency mode operation), the batteries need to be charged for at least 24 hours to become sufficiently charged again. If the battery is not completely discharged the required charge time is shorter accordingly. The status of the battery is given by the indicator LED.

Periodic testing
Periodic tests should be performed according to EN 50172:2004, clause 7.2.3 and 7.2.4. monthly, switch on in the emergency mode by simula�on of a failure of the supply to the normal ligh�ng for a period sufficient to ensure that each lamp is illuminated. Annually, each luminaire shall be tested for itsfull rated dura�on (at least
1hr or 3hrs (depending on product installed)).

Self-Test
Luminaires are equipped with a self-test func�onality according IEC 62034. At 28 days a�er power-up the system will perform a func�onal test of 30 seconds.

Every 6th test (a�er half year) will be a dura�on test. Thistest will run un�l the  ba�ery is empty and it will check if the capacity of the ba�ery is sufficient to provide 1hr or 3hrs emergency �me for respec�vely a 1hr or 3hrs system. This will result in 2 full dura�on tests every year.

During the tests the ba�ery and output is checked. During the dura�on test also the ba�ery capacity is checked. In case of a failure, an error will be indicated by the indicator LED.

When scheduling a test (func�onal or dura�on test) the opera�on of the ACdriver is also checked. When the AC-driver is ac�ve, so normal ligh�ng is on, the test will be postponed for a maximum of 3 days. When the AC-driver is off for at least 1 hour the test is started. The func�onal and dura�on test can only be started when the ba�ery is fully charged.

Indoor Luminaire cleaning

Cleaning instruction

It is important to clean luminaires in association with luminaire mounting or component changing. ReŒective parts surfaces should be cleaned from dust and grime pollution.

It is also important to remember that the voltage should be disconnected before the cleaning process is initiated. Electrical components and cables must not be exposed to water or detergents.

Information about luminaire’s components disassembling can be found in user’s instructions

  • Mounting Instruction

  • Component replacement instruction

  1. Switch off power supply.
    Switch off power supply

  2. Wash and wipe the outside part
    Wash and wipe the outside part

  3. Clean the inside of luminaire.
    Cleaning instruction

  4. Do not touch or wet LED modules.
    Cleaning instruction

  5. Сlose the luminaire tightly.
    Cleaning instruction

  6. Make function test.
    Cleaning instruction

Cleaning and drying

Luminiare body
Vacuuming with a soft brush. Neutral dishwashing detergent with lukewarm water / Cleaning detergent, without grinding eŠects, in lukewarm water. Drying: Self-drying in room temperature or wipe oŠ with a slightly damp cleaning cloth.

ReŠector and diuser cover
In case of loose dirt clean with soft duster or cleaning cloth without microbers, or use a compressed air . For light soiling dilute a citric acid based cleaning product with water (e.g. 30 ml Frosch® citrus cleaner in 5 litre of water). Cleaner should be non-abrasive, pH neutral, alcohol-free. In case of heavy soiling: Oil and grease can be removed using a mixture of alcohol and water (1:1), e.g. methylated spirits. Residues of alcohol based cleaning products are easily wiped away with a water-soaked cotton cloth. Stubborn stains can be soaked in diluted citrus cleaner. Drying: Blow-oŠ with compressed air or use a lint-free, fresh and clean cotton cloth.

Plastic covers and caps
Vacuuming with soft brush or compressed air. In case of heavy soiling: cleaning detergent, without grinding eŠects, in warm water, maximum 55 degrees Celcius. Wash with a soft, clean cloth (without microbers) in plenty of water. Rins with lukewarm water. Drying: Self-drying in room temperature or wipe oŠ with a slightly damp cleaning cloth (without microbers).

Terms of use and maintenance

Before luminaire is turned on, it should be mounted according with this mounting instruction or any other applicable regulations.

Mounting instructions

Mounting of luminaire must be performed by a qualied person according with following instructions:

  • The warranty of luminaire does not apply, if the mounting of luminaire has been performed in precipitation (rain, snow, hail).
  • The warranty of luminaire does not apply, if a control system unauthorized by VIZULO or an inapplicable LED driver has been used to drive the luminaire.
  • The warranty of luminaire does not apply, if it has been used in an unsuitable ambient temperature or has been supplied by voltage outside of the specied range.
  • The warranty of luminaire does not apply, if the LED driver program has been changed in any way.
  • The warranty of the luminaire does not apply, if the logged history data of the LED driver has been deleted without the permission of VIZULO.
  • The warranty of luminaire does not apply, if it has been mounted in unspecied angles or upside down (luminaire glass directed up), or it has been completely submerged under water.

Safety instructions

Any actions with the luminaire must be performed by a qualied person, who is certied according with national regulations and requirements.

To prevent any accidents person installing the luminaire must follow national safety requirements and following instructions:

  • The label containing technical parameters of the luminaire has to be studied before the work on it has begun.
  • Any luminaire build or design changes are prohibited.
  • The luminaire must be used in good technical condition and according with this instruction.
  • Only VIZULO authorized spare parts and accessories can be used to repair the luminaire.
  • The repair of luminaire has to be performed by a qualied and certied person.

Maintenance and repair

Luminaire has to be disconnected from electrical grid before it is opened and/or repaired!

  • The person working with the luminaire must follow national regulations and legislations that apply to maintenance and testing of electrical or electronic appliances.
  • The luminaire may need to be cleaned depending on its environment. Only a damp cloth or a sponge may be used to clean the luminaire. Use only household detergents diluted by water.
  • Only VIZULO authorized spare parts may be used for the luminaire.
  • Instruction for changing spare parts must be requested from VIZULO and studied before the repair is attempted.
  • LED modules, lens and LED drivers can be changed on an installed luminaire, but it is advised to perform this task indoor to avoid water entering the luminaire.
  • Spare parts (lens, LED modules and drivers) should be ordered from the information available on the luminaire label.