Ultravation OR245T Orion Ion Generator Instruction Manual

June 12, 2024
Ultravation

Ultravation-LOGO

Ultravation OR245T Orion Ion Generator

Ultravation-OR245T-Orion-Ion-Generator-PRODUCT

Product Information

The Orion Ion Generator is an ion generator designed for HVAC systems. It can be installed internally or externally in most HVAC systems. It is used to enhance indoor air quality by collecting charged particulate matter into the HVAC filter. The product is manufactured by Ultravation, Inc., a company known for producing high-quality air filtration equipment. The Orion Ion Generator comes with a ten-year warranty and is made in the USA.

Package Contents

  • Plug converter with a 6ft power lead

Safety Precautions

  • This unit should be installed and maintained by a trained technician.
  • Risk of fire, electric shock, or injury.
  • This product must be installed within the HVAC system or ductwork.
  • There are no user-serviceable parts.
  • Disconnect power while installing or servicing this product.
  • Never touch the probes when energized.
  • Not intended for outdoor use.

Whole House Air Cleaning
To further enhance indoor air quality, it is recommended to use an Ultravation ProgressiveMedia Air Cleaner with the Orion Ion Generator. The filter frames for the Progressive Media filters are manufactured with the same quality standards as the high-performance filter media. The filtration equipment is built with 100% U.S. origin, galvanized steel, and powder coat finish. Ultravation provides a ten-year warranty for all their filtration equipment.

For more information on Progressive Media Whole House Air Cleaners, visit www.ultravation.com.

Product Usage Instructions

Determining Installation
The Orion Ion Generator can be installed either internally or externally in most HVAC systems. External mounting is recommended when there is metal return ducting. Installing the Orion before any system filtration ensures that charged particulate matter will collect into the HVAC filter. The final installation point is determined by the installing contractors, considering all installation and equipment variables.

Preparation for External Mounting

  1. Attach the external plate.
  2. Rotate the probes 90 degrees.
  3. Attach the bracket.

Preparation for Internal Mounting

  1. Note the position of the probes.
  2. Attach the magnet to the Orion using the supplied 10-32-1/4 screw. Alternatively, use the supplied self-tapping screws for permanent mounting.

Use the external adapter plate when installing the Orion system to metal ductwork. Attach the plate after rotating the probes 90 degrees. Secure it using the supplied self-tapping 10-32-1/4 screw. This ensures there will be no air leakage from the ductwork after installation. Note the location of the probes for proper airflow. Airflow should pass over both probes simultaneously for optimum performance.

Installation Procedure

External Mounting:

  1. Disconnect the main power to the HVAC system (turn applicable breakers off).
  2. Determine a location on the duct and mark the location of both probes using a pencil.
  3. Drill two 1/4″ diameter holes.
  4. Mount the Orion using the supplied screws.
  5. Attach the power cord.
  6. Attach the leads of the power cord to a 24 Va. transformer (polarity is not a concern).
  7. Restore power.
  8. Ensure that the white power indicator on the front of the label is illuminated.

Internal Mounting:

  1. Disconnect the main power to the HVAC system (turn applicable breakers off).
  2. Remove the access door to the equipment.
  3. Mount the Orion using either the magnet or supplied screws.
  4. Attach the power cord.
  5. Attach the leads of the power cord to a 24 Va. transformer (polarity is not a concern).
  6. Restore power.
  7. Ensure that the white power indicator on the front of the label is illuminated.

Note : Always follow safety precautions and consult a trained technician if needed.

Package Contents:

  • 1 Orion Ion Generator
  • 1 6ft 2 conductor power cord
  • 1 In-line fuse
  • 1 Return duct mounting plate
  • One industrial mounting magnet
  • 2 self-tapping 3/4” hex screws
  • 3 1/4” Phillips head screw for magnet mounting and optional mounting plate
  • 2 circular foam gaskets
  • Some models ship with a 110-wall plug converter with a 6ft power lead.

Safety Precautions

It is recommended that this unit be installed and maintained by a trained technician

Warning

  • RISK OF FIRE, ELECTRIC SHOCK OR INJURY
  • THIS PRODUCT MUST BE INSTALLED WITHIN THE HVAC
  • SYSTEM OR DUCT WORK.
  • THERE ARE NO USER-SERVICEABLE PARTS
  • DISCONNECT POWER WHILE INSTALLING OR SERVICING THIS PRODUCT.
  • NEVER TOUCH THE PROBES WHEN ENERGIZED!
  • NOT INTENDED FOR OUTDOOR USE

Determining Installation

The Orion Ion Generator is uniquely designed to be installed either internally or externally in most HVAC systems. External mounting is typically done when metal return ducting is present. Installing the Orion before any system filtration ensures that any charged particulate matter will collect into the HVAC filter. The Orion system may also be installed internally on most furnace and air-conditioning sys- terms. The installing contractors tconsider all installation and equipment variableswhen determining the final installation point.

Preparation for external mounting only:

Ultravation-OR245T-Orion-Ion-Generator-FIG-3

Use the external adapter plate when installing the Orion system to metal ductwork. First, rotate the probes 90 degrees. Use the supplied self-tapping 10-32-1/4” screw. Attaching the plate ensures that there will be no air leakage from the duct work after the installation.

Installation Procedure

  1. Disconnect main power to the HVAC system(turn applicable breakers off)
  2. Determine a location on the duct, use a pencil to mark the location of both probes on the ductwork.
  3. Drill 2 1/4 holes. 4. Mount the Orion with supplied screws 5. Attach power cord
  4. Attach the leads of the power cord to a 24 Va. transformer (polarity is not a concern). 7. Restore power
  5. The Orion has a white power indicator on the front of the label (ensure that the LED is illuminated).

Preparation for internal mounting only:

Important! Note the position of the probes

Attach the magnet to the Orion with the supplied 10-32-1/4” screw. You can also use supplied self-tapping screws to permanently mount the Orion.

Ultravation-OR245T-Orion-Ion-Generator-FIG-6

Installation procedure:

  1. Disconnect the main power to the HVAC system(turn applicable breakers off).
  2. Remove access door to the equipment
  3. Mount the Orion either with the magnet or with supplied screws
  4. Attach the power cord.
  5. Attach the leads of the power cord to a 24 transformer (polarity is not a concern).
  6. Restore power 8. The Orion has a white power indicator on the front of the label (ensure that the LED is illuminated).

IMPORTANT: Probes should be a minimum of 1-1/2 inches from any metal.

Electrical Requirements

  • This product operates on 24 VAC
  • It is recommended to connect to a dedicated transformer.
  • If using the optional wall plug-in transformer connect only to the 110/120 VAC circuit.

Maintenance

No maintenance is required. The Orion uses needlepoint electrode technology which requires no maintenance.

PROGRESSIVE MEDIA
Whole House Air Cleaning

To further enhance your indoor air quality try an Ultravation ProgressiveMedia Air Cleaner with your Orion. We manufacture the filter frames that house our Progressive Media filters to the same quality standards as our high- performance filter media. Built with 100% U.S origin, galvanized steel, and powder coat finish, we back all of our filtration equipment with a ten-year warranty.

For more information on Progressive Media Whole House Air Cleaners go to: www.ultravation.com

Warranty:

Ultravation® Orion offers the Ultravation five-year warranty after the date of consumer purchase. This warranty does not include damage to the unit from accident, misuse, or improper installation. If this product becomes defective, Ultravation will elect to repair or replace the product free of charge. Ultravation will return repaired or replaced warranted products pre-paid to the customer, provided that the product was delivered pre-paid. Ultravation shall have no responsibilities for charges incurred by the customer for the installation or removal of warranted items. Liability is limited only to the replacement or repair of this product. This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state. All returns must be accompanied by a return authorization number, which may be obtained by contacting Ultravation, Inc.

Ultravation, Inc. P.O. Box 165, 212 Ideal Way, Poultney, Vermont 05764 Phone : 1-866-GO-UV-AIR (468-8247) • Fax : 802-287-9203 www.ultravation.com info@ultravation.com Copyright © 2017 Ultravation Inc. DC-IH-3352 REVA

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals