DELTA 06IB2S Power Entry Module EMI Filters Instruction Manual
- June 12, 2024
- Delta
Table of Contents
DELTA 06IB2S Power Entry Module EMI Filters
Product Information
The Series Power Entry Module EMI Filters by DVE are easy-to-install units that incorporate an IEC connector, single or double-fuse holder (IEC 5 x 20mm), double-pole power switch, and an EMI filter. These power modules are UL recognized, CSA certified, and VDE approved.
The switch electrical lifetime is 10,000 cycles, and the maximum inrush current is 50A. The components of the power entry module filters are listed below:
Part Number | Cx (uF) | L (mH) | Cy (pF) | R (Ω) |
---|---|---|---|---|
01IB2D | 7.5 | 0.22 | 2.0 | 2200 |
01IB2S | 1M | 0.45 | – | – |
03IB2D | – | – | – | – |
03IB2S | – | – | – | – |
06IB2D | – | – | – | – |
06IB2S | – | – | – | – |
The specifications of the power entry module filters are as follows:
- Maximum leakage current each line-to-ground @ 115VAC 60Hz: 0.2mA @ 250VAC 50Hz: 0.4mA
- Hipot rating (one minute) line-to-ground: 2250VDC line-to-line: 1450VDC
- Operating frequency: 50/60Hz
- Rated voltage: 115/250VAC
The electrical schematic shows the minimum insertion loss in dB for common mode (L-G) and differential mode (L-G) in a 50-ohm system.
The power entry module filters are available in different types and rated currents. The Delta part numbers and their corresponding rated currents are:
Delta Part Number | Rated Current |
---|---|
01IB2D | 115VAC 1A, 250VAC 1A |
03IB2D | 3A |
06IB2D | 6A |
01IB2S | 1A |
03IB2S | 3A |
06IB2S | 6A |
The mechanical construction of the power entry module filters is represented in the figures below:
Figure A: Double Fuse and Double-Pole Power Switch ConfigurationFigure B: Single Fuse and Double-Pole Power Switch Configuration
Product Usage Instructions
To install the power entry module EMI filters, follow these steps:
- Identify the appropriate part number based on the required rated current and voltage.
- Ensure that the power is disconnected before proceeding with the installation.
- Mount the power entry module in a suitable location using the suggested mounting cutout dimensions provided in the manual.
- Connect the IEC connector to the power source.
- If using a double-fuse holder configuration, insert the fuses into the holder.
- Switch on the double-pole power switch to activate the power supply.
Note: Refer to the electrical schematic and specifications for additional information on electrical ratings and performance.
INTRODUCTIONS
- Power module incorporates an IEC connector, single or double-fuse (IEC 5 x 20mm) holder, and double-pole power switch, plus an EMI filter all-in-one easy-to-install unit.
- All part numbers are UL recognized, CSA certified and VDE approved.
- Switch electrical lifetime: 10,000 cycles. Maximum inrush current: 50A.
COMPONENTS
PART NO. | Cx (uF) | L (mH) | Cy(pF) | R ( ) |
---|---|---|---|---|
01IB2D |
0.22
| 7.5|
2200
|
1M
01IB2S
03IB2D| 2.0
03IB2S
06IB2D| 0.45
06IB2S
MINIMUM INSERTION LOSS IN dB
TYPE & RATED CURRENT
DELTA PART NO. | 01IB2D | 03IB2D | 06IB2D | 01IB2S | 03IB2S | 06IB2S |
---|---|---|---|---|---|---|
RATED CURRENT 115VAC | 1A | 3A | 6A | 1A | 3A | 6A |
250VAC | 1A | 3A | 6A | 1A | 3A | 6A |
IEC CONNECTOR | ||||||
FUSE | DOUBLE | SINGLE | ||||
DOUBLE-POLE POWER SWITCH | DOUBLE | DOUBLE | ||||
ELECTRICAL SCHEMATIC | FIG. A | FIG. B |
- UL, CSA, VDE approved current rating: UL/CSA-10A both at 125VAC and 250VAC: VDE-4A/250VAC.
MECHANICAL CONSTRUCTION
SPECIFICATIONS
- Maximum leakage current each line-to-ground @ 115VAC 60Hz: 0.2mA @ 250VAC 50Hz: 0.4mA
- Hipot rating (one minute) line-to-ground: 2250VDC line-to-line: 1450VDC
- Operating frequency: 50/60Hz
- Rated voltage: 115/250VAC
ELECTRICAL SCHEMATIC
DIMENSIONS
Read User Manual Online (PDF format)