RADWIN 2000 EC00 5 GHz High Performance PtP Outdoor Unit User Guide

June 12, 2024
RADWIN

RADWIN 2000 EC00 5 GHz High-Performance PtP Outdoor Unit

Product Information
The RADWIN 2000 EC00 and RADWIN 2000 EI00 are high-performance Point-to-Point outdoor units operating in the 5 GHz frequency band. These devices are proprietary radio devices that can only be deployed and maintained by RADWIN professional installers or authorized subcontractors. The firmware of the device is factory-programmed to operate under FCC rules and ISED regulation restrictions. The device incorporates geo-location capability and will only operate within the boundaries of the regional restrictions. The RADWIN 2000 EC00 form factor can be connected to a wide range of directional antennas, while the RADWIN 2000 EI00 form factor incorporates a 24 dBi gain directional antenna. Here are the certified antennas that can be used with the RADWIN 2000 EC00 and RADWIN 2000 EI00:

Antenna Type Model Number Antenna Max Gain (dB) Dir BW (deg)
Integrated MR0284310 24 9
External Flat RW-9622-5001 28 5
External Dish RW-9721-5158 28 5.6
External Dish RW-9732-4958 32 4
External Dish RW-9732-4965 25 7

The maximum output power of the device is limited to 28 dBm, and The EIRP (Equivalent Isotropically Radiated Power) is 53 dBm.

Product Usage Instructions

  1. Ensure that the device is installed and operated with a minimum safe distance between the radiator and your body, as indicated in the Antenna Details Table.
  2. Only deploy and maintain the RADWIN 2000 EC00 and RADWIN 2000 EI00 devices through RADWIN professional installers or authorized subcontractors.
  3. The firmware of the device is locked and inaccessible by any third party. Do not attempt to modify or make changes to the firmware, as it may void your authority to operate the equipment.
  4. Connect the appropriate certified antenna to the RADWIN 2000 EC00 or use the built-in 24 dBi gain directional antenna of the RADWIN 2000 EI00.
  5. Ensure that the total output power does not exceed 28 dBm and the EIRP does not exceed 53 dBm.
  6. Familiarize yourself with the radio parameters accessible by end-users for further customization and configuration.

Note : For any assistance regarding installation, operation, or compliance, consult the dealer or an experienced radio/TV technician.

Regulatory Compliance

FCC/ISED – Compliance
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules and ISED RSS standards. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and the receiver.
  • Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

Changes or modifications to this equipment not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Outdoor units and antennas should be installed ONLY by experienced installation professionals who are familiar with local building and safety codes and, wherever applicable, are licensed by the appropriate government regulatory authorities. Failure to do so may void the product warranty and may expose the end user or the service provider to legal and financial
Caution liabilities. Resellers or distributors of this equipment are not liable for injury, damage, or violation of regulations associated with the installation of outdoor units or antennas. The installer should configure the output power

Warning
This equipment should be installed and operated with a minimum safe distance between the radiator and your body as indicated in the Antenna Details Table. The device is granted to operate under FCC Rules in the 5.15-5.25 GHz and 5.725-5.85 GHz bands.
This device complies with Part 15 of the FCC rules and with ISED license- exempt RSS standard(s). Operation is subject to the following two conditions:

  1. This device may not cause harmful interference.
  2. This device must accept any interference received, including interference that may cause undesired operation.

This device contains license-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada’s license-exempt RSS(s). Operation is subject to the following two conditions:

  1. This device may not cause interference.
  2. This device must accept any interference, including interference that may cause undesired operation of the device

This Class B digital apparatus complies with Canadian ICES-003.

Overview

  • RADWIN 2000 EC00, and RADWIN 2000 EI00 are high-performance Point-to-Point outdoor units that operate in the 5 GHz band that can deliver peak capacity of up to 1.2 Gbps.
  • RADWIN 2000 EC00 is the connector-sized form factor and RADWIN 2000 EI00 is the integrated antenna form factor
  • RADWIN 2000 EC00 form factor can be connected to a wide range of directional antennas.
  • RADWIN 2000 EI00 form factor incorporates a 24 dBi gain directional antenna
  • RADWIN 2000 EC00, and RADWIN 2000 EI00 include a field-proven air interface that ensures best-in-class link connectivity in the harsh spectrum for backhaul and access as well as wireless CCTV and additional applications that require robust connectivity.

For this purpose, RADWIN 2000 EC00, and RADWIN 2000 EI00 are designed to deliver an impressive packet switching power to guarantee full capacity, regardless of traffic packet size.
Enabling minimum TCO, the RADWIN 2000 EC00, and RADWIN 2000 EI00 are extremely reliable and durable, complying with IP67, NEMA Type 4 enclosure rating. The unit features a built-in GPS for TDD synchronization and is powered by PoE

Basic Features

  • Modulation OFDM – BPSK, QPSK, 16QAM, 64QAM, 256QAM, 1024QAM, 4096QAM
  •  Operating frequency range and Channel Bandwidths:
  •  5150 – 5250 MHz at 20, 40, 80 MHz CBW (*only under FCC Rules)
  •  5725 – 5850 MHz at 20, 40, 80 MHz CBW
  •  Supporting geolocation-based configuration capability

Condition of Use
The RADWIN 2000 EC00 and RADWIN 2000 EI00 a proprietary radio devices that can only be deployed and maintained by RADWIN professional installers or its authorized subcontractors

FCC Rules and ISED Regulation Restrictions
The device firmware is factory-programmed to operate under the FCC rules and ISED regulation restrictions. The firmware is locked and inaccessible by any third party. The device incorporates geo-location capability and will only operate within the boundaries of the regional restrictions.

Antenna
RADWIN 2000 EC00 form factor can be connected to a wide range of directional antennas as detailed in the certified antennas table
RADWIN 2000 EI00 form factor incorporates a 24 dBi gain directional antenna

Certified Antenna
Following are the antennas certified for use with the RADWIN 2000 EC00, and RADWIN 2000 EI00:

Antenna Type

| Model Number| Antenna Max Gain (dBi)|

Dir BW (deg)

| Safe

Distance (cm)

---|---|---|---|---
Integrated| MR0284310| 24| 9| 135
External Flat| RW-9622-5001| 28| 5| 205
External Dish| RW-9721-5158| 28| 5.6| 185
External Dish| RW-9732-4958| 32| 4| 300
External Dish| RW-9732-4965| 25| 7| 145

Maximum Output Power
5725 – 5850 MHz band – FCC Part 15 Subpart E, ISED RSS 247 The maximum output power can be set as follows, when operating in the 5.725-5.85 GHz band, under FCC 47 CFR Part 15.407 New Rules and ISED RSS-247 regulations. Total output power is limited to 29 dBm. 5150 – 5250 MHz band – FCC Part 15 Subpart E The maximum output power can be set as follows when transmitting in the 5.15-5.25 GHz band, under FCC 47 CFR Part 15.407 New Rule. Total output power is limited to 28 dBm and the EIRP is 53 dBm

Radio parameters accessible by end-user

The following parameters can be accessed by the user:

  1. Output Power (constrained to the limitations)
  2. Frequency channel
  3. Channel bandwidth

Read User Manual Online (PDF format)