Olympia BS-812-P Programmable Thermostat User Manual
- June 12, 2024
- OLYMPIA
Table of Contents
BS-812-P Programmable Thermostat
**User Manual
**
THERMOSTAT MENU
MENU INFORMATIONS
To enter the menu, press and hold the key for 1 sec.
Navigation/setting of the menu is done with the keys
Entering the individual menus and saving the settings is done by pressing the
key
To exit the menu press the key
Set time and date.
In mode (factory setting) you manually set the temperature by pressing the
keys
In mode you set the weekly schedules. To set the programs, follow the steps
below:
- In screen Add (P1), press the key to add the program.
- Set the temperature by pressing the keys and press
- Set the days according to figure 1.
- Set the starting hour by press the keys and press
- Set the stoping hour by press the keys and press
Next, you can add more programs or you can finish the setting by navigating to
screen.
Up to 20 programs can be set.
To delete the saved weekly schedules. Select the weekly schedule you want to
delete, set the temperature to zero until the is displayed and press the key
Enabling this mode, the backlight of the screen remains off to save battery power.
Enabling the PIN, the temperature usage limits and the entry to the menu are
locked.
Enabling PIN does not restrict the use of the functions of the home screen. If
the weekly schedule and PIN number are activated , it is not possible to set
the usage limits, enable the night mode and enable the absent mode. In this
case the PIN number only locks the menu entry. To disable the PIN, go to the
menu PIN and select . To change the PIN number you should disable the PIN
number and set the PIN number from the start. In case you have forgotten the
PIN number, a manual reset is possible.
Advanced menu configuration
-
Boiler operating time setting*.
Set the boiler operating time from 1-240 minutes. If the boiler time is 00, disable the boiler by pressing the key . Factory settting is -
, Night mode temperature setting.
Factory setting is 18.0 °C. -
, Absent mode temperature setting.
Factory setting is 14.0 °C. -
, Calibration of the temperature sensor Factory setting is 0.0 C and can be configured from -3.0 to +3.0 °C.
-
, Differential setting.
This setting defines the “temperature window” between enabling/disabling of the burner output. Factory setting is 0.2 °C and can be configured from 0.2 to 1.5 °C. -
, Operation mode of the thermostat (heating/cooling) For the heating mode: (factory default) and cooling: .
-
, Temperature display/measuring unit (Celsius degrees C or Fahrenheit degrees F)
-
, Factory defaults settings.
To reset the device press the key twice.
In this menu, the statistics recorded by the thermostat is displayed.
- Burner operating hours.
- Boiler operating hours.*
- Maximum room temperature value
- Minimum room temperature value
- To reset the statistics, go to the screen and press the key
INSTALLATION INSTRUCTIONS
|
---|---
|
|
- Wall mounting with recommended height: 1.5m from the floor on an internal wall.
- Do not mount the devices in recesses, shelves, behind curtains or doors, or above or near heat sources.
- Avoid direct exposure to sunlight
WARNING HEALTH AND SAFETY INFORMATION
National safety regulations
Failure to comply with national safety regulations may result in personal
injury, discomfort,property damage and other potential hazards.
- Comply with any national regulations and comply with appropriate safety regulations
- You shall comply with any additional national regulatory informations.
Risk of electric shock
Disconnect the power supply before any interference with the system
WARNING! installation, configuration, start-up and maintenance must be
done by qualified personnel only.
INFORMATIONS
GENERAL
Removing the plastic separator film between the two batteries, the thermostat
is activated. The current room temperature is shown in the centre of the
display. Switch-on the thermostat pressing the key
Firstly, set the current time and day, by navigating to the menu Hour. Then,
set the temperature pressing the keys .
To enable the night mode press the key for 1 sec. The factory temperature
setting is 18.0 °C and can be changed navigating to the menu . This mode is
disabled after 8 hours.
To enable the absent mode press the key for 1 sec. The factory temperature
setting is 14.0 °C and can be changed navigating to the menu .
To enable the boiler (BS-813/P & BS-813/P/C) press the key and the
correspoding relay will command the boiler. The boiler will remain active as
long as, it has been defined from the boti menu. In case, that the value is
the factory default, then the boiler can be disabled only pressing the key
In case, the weekly schedule is enabled and change the temperature manually.
The temperature remains the manual selection for 5 hours and after that the
weekly schedule is been enabled again.
BATTERY REPLACEMENT
If the symbol appeared on the display, then the batteries must be replaced.
Remove the front cover and replace the batteries with new one, same type and
characteristics (2 alkaline batteries ΑΑ, 1.5V). Replace the front cover.
Dispose the old batteries for recycling, in compliance with current
enviromental protection regulations.
ANTI-FREEZE PROTECTION
If the room temperature value is 4.5 °C, then the thermostat will enable the
burner, regardless the thermostat status. This mode remains active, as long as
the temperature is below 4.5 °C.
THERMOSTAT KEYPAD LOCK
To lock the thermostat press simultaneously the keys for 2 sec.
To unlock press the same keys again.
KEYPAD DESCRIPTION
DISPLAY INDICATORS DESCRIPTION
The selection temperature is smaller than the current temperature
The selection temperature and the differential is greater than the current
temperature
The selection temperature is between the selection temperature and the
selection + the defferential
The device is considered an electronic device for disposal in accordance with the European Guidelines and may not be disposed of as domestic garbage.
- Dispose of the device through channels provided for this purpose.
- Comply with all local and currently applicable laws and regulations.
- Dispose of empty batteries in designated collection points.
*BS-813/P & BS-813/P/C model with boiler output
PROGRAMMABLE CHRONO – THERMOSTAT WITH COOLING AND HEATING FUNCTION
- Backlight screen
- 2 Alkaline batteries AA (LR06)
- Temperature setting 5.0 – 45.0°C with accuracy 0.1
- Temperature measurement 0.0 – 99.9°C with accuracy 0.1
- Anti-freeze protection to 4.5°C
- Keypad lock.
- Lock temperature usage limits with PIN number
- Boiler output*
- Temperature sensor calibration ±3.0°C
- Adjustable differential 0.2 – 1.5°C
- Heating/Cooling function.
- Temperature Unit (°C, °F)
- Up to 20 weekly schedules
- ECO mode
TECHNICAL CHARACTERISTICS
WARRANTY
Thank you for your trust in our products Olympia Electronics – European
manufacturer
Olympia Electronics guarantees the quality, condition and operation of the
goods. The period of warranty is specified in the official catalogue of
Olympia Electronics and also in the technical leaflet, which accompanies each
product. This warranty ceases to exist if the buyer does not follow the
technical instructions included in official documents given by Olympia
Electronics or if the buyer modifies the goods provided or has any repairs or
re-setting done by a third party, unless Olympia Electronics has fully agreed
to them in writing. Products that have been damaged can be returned to the
premises of our company for repair or replacement, as long as the warranty
period is valid. Olympia Electronics reserves the right to repair or to
replace the returned goods and to or not charge the buyer depending on the
reason of defection. Olympia Electronics reserves the right to charge or not
the buyer the transportation cost.
72nd km. O.N.R. Thessaloniki-Katerini
P.C. 60300 P.O. Box 06 Εginio Pierias Greece
www.olympia-electronics.com
info@olympia-electronics.gr
940813002_09_002
Documents / Resources
|
Olympia BS-812-P Programmable
Thermostat
[pdf] User Manual
BS-812-P Programmable Thermostat, BS-812-P, Programmable Thermostat,
Thermostat
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>