Table of Contents
- Installation
- Leak check
- Cleaning
- Recycling
- Technical Information
- Fitting
- Connection Of Spout
- Dishwasher
- Swivel Spout
- Temperature Limiter
- Replace O-rings
- Cleaning the Aerator
- Cartridge Replacement
- Cartridge Replacement Dishwasher
- Technical Information
- Fitting
- Temperature Limiter
- Cleaning The Aerator
- Cartridge Replacement
- Troubleshooting
- Customer Support
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
MORA INXX II Single Lever Mixers
Installation
We recommend that you entrust an authorised plumber. NOTE! For new pipe
installations, the pipes must be flushed clean before the mixer is fitted.
When connecting mixers that are equipped with Soft PEX® coupling pipes, the
connection point should be firmly secured using pipe clamps. See pictures
under the respective product.
Leak check
Leak checks should be made according to the industry rules in the respective
country.
Damage arising as a consequence of stress corrosion cracking arising due to
the water’s or the ambient environment’s nature as well as incorrect fitting
is not covered by the product liability.
Where there is a risk for frost
If the mixer will be subjected to external temperatures lower than 0 °C (e.g. in an unheated holiday home), the mixer should be disconnected and stored in a heated space.
Cleaning
Make a habit of frequently wiping your mixer clean to prolong its life. We
recommend using a microfibre cloth. If necessary, dampen the cloth with water.
Alternatively, use a mild soap solution, rinse immediately and wipe the
surface dry. We do not recommend using abrasive sponges, acid detergents,
descalers or spirit vinegar to clean your mixer. Because the content of these
productsis constantly changing, they risk damaging the surface of your mixer.
Our guarantee does not cover any damage to the mixer’s surface that is caused
by incorrect cleaning.
For mixers that do not have a chrome finish, see the specific care
instructions for the product on our website.
Spareparts
www.moraarmatur.com
Recycling
Disused products can be returned to Mora Armatur for recycling.
Technical Information
-
Art No: 27 20 51.xx
-
Art No: 27 20 71.xx
-
Art No: 27 21 01.xx
-
Art No: 27 21 51.xx
-
Art No: 27 20 81.xx
-
Art No: 27 20 91.xx
Standard | EN 817 |
---|---|
Working pressure | 50–1000 kPa |
100–500 kPa
Max test pressure| 1600 kPa
Max hot water temperature| 80 °C (60 °C)
Cold water temperature| ≈10 °C
Backflow preventer| SS-EN 1717| AA 27 20 51.xx
27 20 71.xx
27 21 01.xx
27 21 51.xx
EB 27 20 81.xx
27 20 91.xx
Fitting
Connection Of Spout
Dishwasher
Swivel Spout
Temperature Limiter
Replace O-rings
Cleaning the Aerator
Cartridge Replacement
Cartridge Replacement Dishwasher
Technical Information
-
Art No: 27 30 01.xx
-
Art No: 27 30 03.xx
-
Art No: 27 30 05.xx
-
Art No: 27 30 11.xx
-
Art No: 27 30 13.xx
-
Art No: 27 30 21.xx
-
Art No: 27 30 23.xx
-
Art No: 27 30 25.xx
Standard | EN 817 |
---|---|
Working pressure | 50–1000 kPa |
100–500 kPa
Max test pressure| 1600 kPa
Max hot water temperature| 80 °C (60 °C)
Cold water temperature| ≈10 °C
Backflow preventer| SS-EN 1717| AA
| EB 27 30 05.xx
27 30 25.xx
Connection| Soft PEX®
Fitting
Temperature Limiter
Cleaning The Aerator
Cartridge Replacement
Troubleshooting
Drips from the spout or the lever attachment when the mixer is turned off.|
Defective cartridge.| Replace cartridge.
---|---|---
Leakage from spout connection (kitchen mixer)| Defective O-rings| Replace
O-rings. Lucricate with silicone grease.
The mixer produces too little| 1. Clogged aerator.| 1. Replace the aerator.
water.| 2. Water inlet blocked.| 2. Replace cartridge.
The lever is stiff/loose.| Dirt/particulates in the cartridge.| Replace
cartridge.