MORA INXX II Single Lever Mixers Instruction Manual

June 12, 2024
MORA

MORA INXX II Single Lever Mixers

MORA INXX II Single Lever Mixers

Installation

We recommend that you entrust an authorised plumber. NOTE! For new pipe installations, the pipes must be flushed clean before the mixer is fitted.
When connecting mixers that are equipped with Soft PEX® coupling pipes, the connection point should be firmly secured using pipe clamps. See pictures under the respective product.

Leak check

Leak checks should be made according to the industry rules in the respective country.
Damage arising as a consequence of stress corrosion cracking arising due to the water’s or the ambient environment’s nature as well as incorrect fitting is not covered by the product liability.

Where there is a risk for frost

If the mixer will be subjected to external temperatures lower than 0 °C (e.g. in an unheated holiday home), the mixer should be disconnected and stored in a heated space.

Cleaning

Make a habit of frequently wiping your mixer clean to prolong its life. We recommend using a microfibre cloth. If necessary, dampen the cloth with water. Alternatively, use a mild soap solution, rinse immediately and wipe the surface dry. We do not recommend using abrasive sponges, acid detergents, descalers or spirit vinegar to clean your mixer. Because the content of these productsis constantly changing, they risk damaging the surface of your mixer. Our guarantee does not cover any damage to the mixer’s surface that is caused by incorrect cleaning.
For mixers that do not have a chrome finish, see the specific care instructions for the product on our website.

Spareparts
www.moraarmatur.com

Recycling

Disused products can be returned to Mora Armatur for recycling.

Technical Information

  • Art No: 27 20 51.xx

  • Art No: 27 20 71.xx

  • Art No: 27 21 01.xx

  • Art No: 27 21 51.xx

  • Art No: 27 20 81.xx

  • Art No: 27 20 91.xx

Standard EN 817
Working pressure 50–1000 kPa

100–500 kPa
Max test pressure| 1600 kPa
Max hot water temperature| 80 °C (60 °C)

Cold water temperature| ≈10 °C
Backflow preventer| SS-EN 1717| AA 27 20 51.xx
27 20 71.xx
27 21 01.xx
27 21 51.xx
EB 27 20 81.xx
27 20 91.xx

Fitting


Connection Of Spout

Dishwasher

Swivel Spout



Temperature Limiter



Replace O-rings

Cleaning the Aerator

Cartridge Replacement



Cartridge Replacement Dishwasher

Technical Information

  • Art No: 27 30 01.xx

  • Art No: 27 30 03.xx

  • Art No: 27 30 05.xx

  • Art No: 27 30 11.xx

  • Art No: 27 30 13.xx

  • Art No: 27 30 21.xx

  • Art No: 27 30 23.xx

  • Art No: 27 30 25.xx

Standard EN 817
Working pressure 50–1000 kPa

100–500 kPa
Max test pressure| 1600 kPa
Max hot water temperature| 80 °C (60 °C)

Cold water temperature| ≈10 °C
Backflow preventer| SS-EN 1717| AA
| EB    27 30 05.xx
27 30 25.xx
Connection| Soft PEX®

Fitting


Temperature Limiter



Cleaning The Aerator

Cartridge Replacement


Troubleshooting

Drips from the spout or the lever attachment when the mixer is turned off.| Defective cartridge.| Replace cartridge.
---|---|---
Leakage from spout connection (kitchen mixer)| Defective O-rings| Replace O-rings. Lucricate with silicone grease.
The mixer produces too little| 1. Clogged aerator.| 1. Replace the aerator.
water.| 2. Water inlet blocked.| 2. Replace cartridge.
The lever is stiff/loose.| Dirt/particulates in the cartridge.| Replace cartridge.

Customer Support

FM Mattsson Group
Box 480, SE-792 27 Mora
Tel. +46 (0)250 59 60 00
www.moraarmatur.com

Logo

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

MORA User Manuals

Related Manuals