HAISEN HD401S On/Off Switch Sensor for Ceiling Light Instruction Manual
- June 12, 2024
- HAISEN
Table of Contents
For ceiling light
HD401S (Highbay)
- Automatic On/off control with Daylight sensor.
- Optional detection range, hold time and daylight threshold.
- Compact sized particularly suitable for Ceiling lights or Bulkhead.
- Loop in and loop out for easy installation.
- 3 years warranty.
On/off control Detection area
Hold time Daylight threshold
10-15M Highbay
Detection coverage
Typical installation height 8-12m
This figure indicates the maximum distance at the highest mounting height with
100% sensitivity.
Well covered Covered
Technical data
Operating voltage | 120-277VAC,50Hz/60Hz |
---|---|
Switching capacity | Max,3.0A@120Vac,50/60Hz; |
Max,2.0A@277Vac,50/60Hz
Stand-by power| ≤1W
Operating temperature| – 20°C~+60°C
Detection area| 10%/50%/75%/100%
Hold time| 5s/90s/5min/15min
Daylight threshold| 2Lux/10Lux/50Lux/Disable
Microwave frequency| 5.8GHz±75MHz
Microwave power| <0.3mW
Mounting height| Max,12m/39.ft (ceiling mounted)
Detection range| Max14m/45.92ft (ceiling mounted)
Motion detection| 0.5~1.5m/s
IP rating | IP20
Warranty| 3 years
Factory Default Setting: Detection area 100%/ Hold time 5s/ Daylight threshold Disable.
Mechanical structure
- Installation hole
- Input
- Output
- Daylight sensor
- Antenna module
- Daylight threshold
- Hold time
- Detection area
Specifications subject to change without notice. ©All rights reserved.
Dimensions (Unit: mm)
Wiring diagram
Settings
- Switch UP
- Switch DOWN
- Daylight threshold
- Hold-time
- Detection area
1
| 2|
---|---|---
•| •|
100%
Ο| •| 75%
•| Ο|
50%
Ο| Ο|
10%
Detection area
In this area, movement will be detected and able to trigger the sensor.100%
detection area is also known as the strong sensitivity.
3
| 4|
---|---|---
•| •|
5s
Ο| •| 90s
•| Ο|
5min
Ο| Ο|
15min
Hold-time
The period of light keeping 100% brightness after moving objects leave the
detection area.
5
| 6|
---|---|---
•| •|
Disable
Ο| •| 50lux
•| Ο|
10lux
Ο| Ο|
2lux
Daylight threshold
Definition of the ambient brightness; only when the ambient brightness is
lower than the preset specific lux amount, the sensor will work; when it’s
preset as “disable”, the sensor works every time it detects motion regardless
the ambient brightness.
Application
1.Automatically ON/OFF function
Light on when detect movement and off after people leave at night. Applications: Corridor, Staircase.
With sufficient daylight, even when motion detected, light remains OFF.
With insufficient daylight, when motion detected, light ON.
After the last detection and the present hold time elapsed, light OFF.
2. No daylight function
The daylight threshold is set to “Disable”.
Light on when detect movement, After people leave, Light off after hold on
time. Applications: Dim places such as Basement Parking, Underpass.
When motion is detected, the sensor will switch on the light to 100% brighteness.
After people leave the detection area, light remains 100% brightness within hold time.
After the last detection and the present hold time elapsed, light OFF.
Installation Method
Please ensure no any metal is thielding the sensor antenna.
Please ensure no any metal is thielding the sensor antenna.
Attention
- Please read the instructions carefully before using this product and keep it well for all users to read at any time.
- The sensor should be installed by qualified electrician and ensure power is off before the installation.
- We reserve the right to modify any incorrect text, image and necessary technical parameters.
- Any unauthorized modification is forbidden, otherwise all guarantees will be immediately invalid.
Installation precautions
- Microwave sensor can be installed in any lamp except the one with full metal shell.
- The detected surface cannot be shielded by metal objects.
- Make sure the microwave module is completely exposed outside.
- The detection surface of the sensor module shall be installed facing the detection area.
- Should be kept away from the driver to avoid interference generation and lamp flashing.
- Wiring must be strictly in accordance with the wiring diagram to avoid short circuit.
Application Environment
- Suitable for indoor installation to avoid false triggering due to external factors such as rain, wind or tree swing.
- Shall not be installed in the place with all four metal shelters and small space (such as galvanized-iron roof ).
- Shall note be mounted installation, so as to avoid false trigger caused by the lamp itself shaking.
- Shall not be installed next to large operating machines such as ventilator/ceiling fan to avoid false triggering caused by machine vibration.
User Notes
- Microwave can penetrate walls or glass thinner than 20cm and attenuate if thicker than 20cm.
- The driver voltage shall be stable and float within 10%.
- Detection area will be affected by speed of motion, mounting height and movement volume.
- Conduct test on sunny days without the lampshade which will affect the tested lux value
Shenzhen Haisen Technology Co., Ltd., Tel: +86-755-82598105 丨Fax: +86-755-82598106丨Email: info@haisensz.com 丨www.haisensz.com Haisen Technology
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>