Product Information

  • Model: HD402S-6
  • Features:
1. Automatic On/off control with Daylight sensor
2. Optional detection range, hold time, and daylight threshold
3. Compact size, particularly suitable for tri-proof light
4. Loop in and loop out for easy installation
5. 3-year limited warranty
  • Typical Installation Height: 2.5-6m
  • Ceiling Mounted: 65 4 3 2 2 3 4 56 1 2 3 4 5 6 4 3 2 1
  • Wall Mounted: 123456789 Well covered Covered
  • Operating Voltage: Variable
  • Switching Capacity: Variable
  • Stand-by Power: Variable
  • Detection Area: Variable
  • Hold Time: Variable
  • Daylight Threshold: Variable
  • Microwave Frequency: Variable
  • Microwave Power: Variable
  • Mounting Height: Variable
  • Detection Range: Variable
  • Operating Temperature: Variable
  • Motion Detection: Yes
  • IP Rating: Variable
  • Warranty: 3 years limited

Product Usage Instructions

  1. Choose the appropriate mounting method: Ceiling Mounted or Wall Mounted.
  2. For Ceiling Mounted installation, follow the provided diagram and use the indicated screws to secure the product to the ceiling. Ensure that the product is well covered and properly aligned.
  3. For Wall Mounted installation, follow the provided diagram and use the indicated screws to secure the product to the wall. Ensure that the product is well covered and properly aligned.
  4. Set the desired operating voltage, switching capacity, stand-by power, detection area, hold time, daylight threshold, microwave frequency, microwave power, mounting height, detection range, operating temperature, and IP rating based on your specific requirements.
  5. Ensure that the motion detection feature is enabled.
  6. Connect the product to the power supply according to the provided instructions.
  7. Observe the automatic on/off control with daylight sensor function. The product will detect motion and adjust its lighting accordingly.
  8. If any issues arise during usage, refer to the product’s limited warranty for support and contact the manufacturer for assistance.

Features

  1. Automatic On/off control with Daylight sensor.
  2. Optional detection range, holdtime and daylight threshold .
  3. Compact sized particularly suitable for tri-proof light.
  4. Loop in and loop out for easy installation.
  5. 3 year limited warranty.

Technical data

Operating voltage 120VAC 50Hz/60Hz
Switching capacity Max.3.0A@120Vac
Stand-by power ≤1W
Detection area 10%/50%/75%/100%
Hold time 5s/90s/5min/10min
Daylight threshold 2Lux/10Lux/50Lux/Disable
Microwave frequency 5.8GHz±75MHz
Microwave power <0.3mW
Mounting height 2.5-6m/8.2-19.68ft (ceiling mounted)
Detection range Radius, 3-6m/9.84-19.68ft (ceiling mounted)
Operating temperature -20°C~+60°C
Motion detection 0.5~1.5m/s
IP rating IP20
Warranty 3 years

Factory Default Setting: Detection area 100%/ Hold time 5s/ Daylight threshold Disable.

Detection coverage

Typical installation height 2.5-6m
This figure indicates the maximum distance at the highest mounting height with 100% sensitivity.

HAISEN-HD402S-6-Dimmable-Motion-Sensor-Microwave-for-Tri-proof-Light-fig-
\(2\)

Mechanical structure

HAISEN-HD402S-6-Dimmable-Motion-Sensor-Microwave-for-Tri-proof-Light-fig-
\(3\)

Dimensions

Dimensions (Unit: mm)

Wiring diagram

Settings

Detection area
In this area,movement will be detected and able to trigger the sensor.100% detection area is also known as the strong sensitvity.

Hold-time
The period of light keeping 100% brightness after moving objects leave the detection area.

Daylight threshold
Definition of the ambient brightness; only when the ambient brightness is lower than the preset specific lux amount, the sensor will work; when it’s preset as “disable”,the sensor works everytime it detects motion regardless the ambient brightness.

Installation Method

HAISEN-HD402S-6-Dimmable-Motion-Sensor-Microwave-for-Tri-proof-Light-fig-
\(10\)

Application

  1. Automatically ON/OFF function
    Light on when detect movement and off after people leave at night. Applications: Corridor, Staircase.

    • With sufficient daylight, even when motion detected, light remains OFF.
    • With insufficient daylight, when motion detected, light ON.
    • After the last detection and the present hold time elapsed, light OFF.
  2. No daylight function
    The daylight threshold is set to “Disable”. Light on when detect movement, After people leave, Light off after hold on time. Applications: Dim places such as Basement Parking, Underpass.

    • When motion is detected, the sensor will switch on the light to 100% brighteness.
    • After people leave the detection area, light remains 100% brightness within hold time.
    • After the last detection and the present hold time elapsed, light OFF.

Attention

  1. Please read the instructions carefully before using this product and keep it well for all users to read at any time.
  2. The sensor should be installed by qualified electrician and ensure power is off before the installation.
  3. We reserve the right to modify any incorrect text, image and necessary technical parameters.
  4. Any unauthorized modification is forbidden, otherwise all guarantees will be immediately invalid.

Installation precautions

  1. Microwave sensor can be installed in any lamp except the one with full metal shell.
  2. The detected surface cannot be shielded by metal objects.
  3. Make sure the microwave module is completely exposed outside.
  4. The detection surface of the sensor module shall be installed facing the detection area.
  5. Should be kept away from the driver to avoid interference generation and lamp flashing.
  6. Wiring must be strictly in accordance with the wiring diagram to avoid short circuit.

Application Environment

  1. Suitable for indoor installation to avoid false triggering due to external factors such as rain, wind or tree swing.
  2. Shall not be installed in the place with all four metal shelters and small space (such as galvanized-iron roof ).
  3. Shall note be mounted installation, so as to avoid false trigger caused by the lamp itself shaking.
  4. Shall not be installed next to large operating machines such as ventilator/ceiling fan to avoid false triggering caused by machine vibration.

User Notes

  1. Microwave can penetrate walls or glass thinner than 20cm and attenuate if thicker than 20cm.
  2. The driver voltage shall be stable and float within 10%.
  3. Detection area will be affected by speed of motion, mounting height and movement volume.
  4. Conduct test on sunny days without the lampshade which will affect the tested lux value

Shenzhen Haisen Technology Co., Ltd., Tel: +86-755-82598105 Ι Fax: +86-755-82598106 Ι  Email: [email protected]www.haisensz.com.

References