PLEASE REVIEW THE INSTRUCTIONS AND WARNINGS LISTED BELOW PRIOR TO PROPER INSTALLATION
WARNINGS
- Risk of fire / electrical shock
- LED Fixture installation requires knowledge of luminaire electrical systems.
- Risk of electric shock – disconnect power at source before installation.
- Do not make or alter any open holes in an enclosure of wiring or electrical components during installation.
- If lamp or luminaire exhibits abnormal operation (buzzing, flickering, minimal light, etc.), turn off power, remove fixture, and contact us.
For more information please visit www.eurilighting.com or call our toll-free number 1-310-787-1100.
CAUTIONS
- Do not use with dimmers.
- Do not look directly at the operating LED Fixture.
- Do not touch this product with wet hands.
- Do not disassemble, repair, or alter lamp.
- Designed for outdoor applications only.
- Suitable for wet locations.
- The luminaires shall be grounded.
- Be careful not to touch the lamp pins to the metal housing when installing.
- This Device is not intended for use with emergency exits or emergency lights.
INSTALLATION INSTRUCTIONS
- Outlet box
- Mounting Plate
- Fixture mounting screw 8/32 “*1/2”
- Fixture mounting screw for plate 8/32 “*35mm
- Wire connectors P3
- Fixture body
- Rubber washers
- Decorative nuts
- Photocell cap
NOTE: Use calking/silicone sealant (not included) around the mounting plate and the wall surface to seal this will prevent water pentration.
Step 1:
Take out the Mounting Plate and install Mounting Plate to the outlet box.
Step 2: CONNECT FIXTURE
Lift fixture to outlet box. Using wire nuts provided connect bare copper wire
from fixture to green or bare copper ground(house) wire. If outlet box is
grounded, wire directly to outlet box. Connect white fixture wire(s) to
neutral supply wire. Connect black fixture wire(s) to power supply wire.
Step 3: MOUNT FIXTURE
Insert fixture mounting screws through holes on the back plate and secure to
cross bar by tightening decorative nuts.
NOTE: Hand tighten decorative nuts. Do not use any tools as over
tightening may occur causing damage to back plate.
DUAL CCT SWITCH
- This Wall Sconce has the unique feature of adjusting the up and down light CCTs separately.
- If the Wall Sconce is mounted onto a wall, the right switch adjusts the bottom lamp between 3000K, 4000K, and 5000K.
- If the Wall Sconce is mounted onto a wall, the left switch adjusts the top lamp between 3000K, 4000K, and 5000K.
PHOTOCELL SENSOR
In order to make us of the Dusk to Dawn sensor, simply screw off the
protective cap from the top of the light mount.
To deactivate the Dusk to Dawn sensor, replace the protective cap onto the top