ASUS TR-WIFICMD Wi-Fi Sensor User Guide
- June 5, 2024
- Asus
Table of Contents
TR-WIFICMD Wi-Fi Sensor
User Guide
A quick look at you Lyra Care
Hardware Specification
- Product segment: Wi-Fi Sensor
- Dimensions: ΦO=10cm, H=3.5cm
- Transmit/ Receive: 802.11ac WAVE2 , 2×2, 2.4/5GHz (20/40/80MHz)
- Power Supply: 12V DC power supply 12V / 1A
- IP Level: IP54
Software Key Features
- Wi-Fi CSI-based Motion and Breathing signal sensing
- The auto-pairing between Origin(Rx) and Bot(Tx)
- Supports cloud and mobile apps for monitoring and alert
Preparation and Requirements
In order to have the best performance, there are a few things that need to be prepared and a few requirements to be met. These items are:
An Indoor Environment
Lyra Care is designed to monitor indoor environments of various sizes. To get
the most out of the system, the indoor environment should have at least two
separate rooms. One of these rooms should be the bedroom, to monitor sleep.
The other room is arbitrary – popular locations are the bathroom or kitchen.
Having two separate rooms enables a software configuration of one master node
and two child nodes. This is the baseline configuration to provide meaningful
well-being data. Sleep and daily activity per room can be monitored.
A Person Living Alone
Lyra Care is designed to monitor a single older adult living alone.*
Currently, the system allows for single-person breathing and sleep monitoring.
Smart Phone
The smartphone which will host the Lyra Care Installer App must be a
smartphone with iOS.12 or later, or Android
Available indoor WiFi or an LTE MiFi:
The master node must communicate with the cloud. It uses the 2.4 GHz WiFi
interface as the communication link. This requires the master to connect to an
indoor WiFi with a 2.4GHz band or an LTE MiFi with a 2.4GHz band.
Device Installation
The next steps involve installing the Lyra Cares. In this kit, we’ve provided
you with four labeled Bots: (1) Origin, (1) Sleep Bot, and (2) Motion Bots.
To get the best well-being results of sleep and daily activity, there are a
few guidelines to follow.
Sleep Bot + Origin Placement
In this pre-beta FTK, the sleep Bot and Origin are used for sleep monitoring.
These devices monitor the rise and fall of a human chest to detect breathing.
To get the best results, they should be placed so that they intersect the
human body, either perpendicular or diagonal. They should be placed above the
height of the mattress. The Origin and the sleep Bot need to be used for this
setup.
Moving devices too close or too far away can have limitations. If the devices are too close, they may not adequately cross the body. If the devices are too far, they may not create a dense enough WiFi sensing area to pick up the periodic chest movement of breathing.
Motion Bot Placement
Motion Bots are used to track the daily activity of the care recipient. Their
placement is more flexible – they can be placed in any room that you want to
monitor. Usually, rooms of interest include the bathroom, kitchen, and living
room.
The rooms where you place the devices it will be displayed in the app. You can change these rooms at any time and simply rename the devices in the app.
The Origin should best be placed so that it sits between the sleep Bot and
the motion Bots.
Some overlap is okay, but this yields better separation of room coverage and
better daily activity results. The motion Bots should be placed around waist
height. Make sure they are not placed too close to each other, again to
provide better separation of rooms.
Motion Bot Placement – Important Tips
When a Motion Bot is placed far away from the Origin, it creates a large
sensing area. This can be seen in the figure below, where the kitchen motion
Bot is far away from the master. In this case, all rooms that are in-between
the kitchen Bot and the Origin will fall under the kitchen Bot’s sensing area.
Motion in these rooms will be recorded as “kitchen motion” because they are in the kitchen Bot’s sensing area.
Motion Bot Placement – More Bots = Better Room Detection
Adding motion Bots to the system yields better motion detection per room and
less overlap.
Motion in these rooms will be recorded as “kitchen motion”, “family room motion”, and “bathroom motion” because each room now has its own motion Bot.
Setup your Lyra Care system
-
Download the free Lyra Care Installer App.
https://play.google.com/store/apps/details?id=com.asus.hive
https://itunes.apple.com/app/asus-lyra/id1171291475?mt=8 -
Launch the Lyra Care Installer App on your mobile device, and follow the instructions in just a few moments.
-
Register and log into Lyra Care Web App. https://lyra-care.com
Status of LED colors
Statement
Federal Communication Commission Interference Statement
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses, and can radiate
radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one of the
following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.→ 15.19 rule
FCC SDoC:
Model name、brand name、15.19 statements and responsible party in USA’s name,
address and telephone number or Internet contact information,
For products available in the USA/Canada market, only channel 1~11 can be
operated.
Selection of other channels is not possible
This device is restricted to indoor use.
This device is going to be operated in the 5.15~5.25GHz frequency range, it is
restricted to an indoor environment only.
This equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated with
a minimum distance of 20cm between the radiator & your body.
FCC Caution:
Any changes or modifications not expressly approved by the party responsible
for compliance could void the user’s authority to operate this equipment.
FCC Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated with
a minimum distance of 20cm between the radiator & your body