Technical Data

LED Power: 148W
Power Input: AC 110V-220V
Color temperature: 3200K / 5600K
CRI(Ra): 95

Product Details

Product Details

Detailed Description

  1. Barndoor: For adjusting the illumination range of fixture.
  2. 2.4G Antenna: Use to receive 2.4G remote control signals.
  3. Display Screen: For showing the related data.
  4. Address Code Button: For adjusting the address code for the fixture’s wireless control.
  5. DMX OUT: DMX signal output interface.
  6. DMX IN: DMX signal input interface.
  7. Dimmer Knob: For adjusting the brightness of the light.
  8. Yoke: For connecting the fixture to the light stand and adjusting the direction of the light.
  9. Angle Fixing Knob: For adjusting and securing the position of the light on in a given position or direction.
  10. Fuse Holder: For placing the fuse.
  11. Power Switch: For powering on/off the fixture.
  12. AC Power Socket: AC power input interface.
  13. Bracket fixing knob: For connecting the fixture and adjusting the horizontal direction of fixture on a stand or other mounting solutions.

Usage

Usage

  1. Connection with the controller
    • The connection cable between the light fixture and control unit, light fixture and light fixture should use three core shielded cable and make sure it’s diameter is not less than 0.3mm2. XLR plug/socket and the wires should be connected as the pictures as above.
    • Pin1, Pin2, Pin3 is for connecting DMX signals, Pin4, Pin5 is connectionless.
    NOTE: When connecting with socket, make sure the internal pins are not in contact with the inner case. The fixture can match the DMX(1990) control signal.
    • Plug of five-core and three-core XLR plug/socket conversion.
    The fixture comes with the five-core XLR plug. If you use the three-core XLR plug, kindly follow below instruction.
    Five Pin
    Pin 1:GND(SCREEN)
    Pin 2:Signal(-)
    Pin 3:Signal(+)
    Pin 4:N/C
    Pin 5:N/C
    Three Pin
    Pin 1:GND(SCREEN)
    Pin 2:Signal(-)
    Pin 3:Signal(+)
    Connection with the controller

  2. 3-Pin DMX circuit
    In DMX mode, make sure the last light is the only light with cable connected to DMX output. There is a resistance about 120(OHM) between the second pin and third pin of this plug(as below photo). Make sure this plug is installed into the output of the last fixture which can avoid noise and reflection phenomenon caused by DMX signal in the transmitting process.

3-Pin DMX circuit connection Connect a 120(OHM) resistance between the 2pin and 3pin of the XLR plug and then connect it to the DMX output socket of the last fixture.
3-Pin DMX circuit

  1. DMX channel control
    When the light is single color, select the address code to 001, it correspond to the CH1 of the console. After confirming the address code, the address code will be the last setting address when turning on the light.

  2. 2.4G Wireless Remote Control
    The D672 is designed to work with a 2.4G remote controller or Nanguang WIFI- APP via WIFI transfer device to control the light remotely.
    NOTE: 2.4G remote controller or WIFI transfer device should be bought additionally. (See separate instructions for remote controller or WIFI transfer device.)

Operating Instructions

  1. Fix the light on a light stand, unfold the barndoor, adjust the angle fixing knob and bracket fixing knob of the fixture to the the best illumination direction and angle.

  2. Please make sure that the power switch on the fixture is in the “off” position, then connect the power cable and turn on the power.

  3. When setting the brightness, rotate the dimmer knob in a clockwise rotation to increase brightness and counterclockwise to decrease brightness. The display will show the data of the brightness range from L.000···L.100. (As figure 1)
    Operating Instructions

  4. When setting the address code, press the “+” to increase the address code number and press “-” to decrease the address code number. The display will shows the address code number of the fixture in the range of A.001···A.512. These two buttons support click or long press. (As figure below)
    Operating Instructions

  5. When stop using the fixture, turn off the switch.

Safety Precautions

  1. Please open the package to check if it is damaged due to transportation after receiving the light. In case of damaged cased by transportation, please do not use the light and contact the dealer or manufacturer as soon as possible.
  2. Do not use a power cord with damaged insulation. Do not unplug hard or drag the power cord directly.
  3. Make sure that the power supply voltage used matches the voltage specified by the light before installation.
  4. When not using or cleaning the light, please turn it off.
  5. Keep the light safely stored and away from children.

Notice

  1. Please make sure that the power voltage and frequency is within the specified range when connecting the power.
  2. When the light is on, don’t look direct at the emitter.
  3. Don’t place objects on the light emitter or allow liquid to flow inside the fixture or the emitter.
  4. Don’t place fixture near flammable substances like alcohol or gasoline.
  5. When cleaning the fixture, please wipe off debris or dirt using cloth and only dampen with water or light cleanser.
  6. The fixture should be placed in a well ventilated place and do not use in humid, dusty or overheated environment. Please also check if the ventilation hole is not obstructed.
  7. Do not repair the fixture yourself. Repair professionals, please adhere the user manual while troubleshooting.
  8. For optimal cooling of the fixture, the vents should not be covered whining using, or will damage the equipment. When using the fixture for a long time, the temperature of the fixture is high, please pay attention to anti-scalding.

What’s in the box?

Please kindly check

  • D672 × 1
    What's in the box?

  • Power Cable × 1

  • User Manual × 1

General Fault Detection and Diagnosis

Fault Detection Diagnosis
The fixture won’t boot up properly.
  1. Please check if the power of the fixture is in “off” position.
  2. Please check if there are any loose connection between the adapter, power cord or port on fixture.

The fixture can light normally, but controllers are not function.|

  1. Please check whether the DMX original address setting of the fixture is correct or not.
  2. Please check if the XLR signal cable is connected correctly or is damaged.

LCD display is on but can not operate light.| The internal CPU is damaged, please contact the supplier or return to the manufacture.

If the failure is not solved after the above troubleshooting procedures, please contact the dealer or manufacturer for repair.

This manual and all stats within it were produced under controlled conditions, and are accurate at time of print. Any future changes to design/technical data can be found at www.nanlite.com.

Customer Support

+86-754-85751187
service@nanlite.com
+86-754-85300887
Zhanglin,324,Dongli Chenghai Shantou Guangdong China
http://www.nanlite.com/

NANLITE Logo

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals