Ferrum HYPSOS and HYPSOS Dual Output Hybrid Power System
Specifications
- Product Name: HYPSOS & HYPSOS Dual Output by Ferrum
- Type: Hybrid Power System
- Power Supply Compatibility: Compatible with many brands
- Operation: Software-based operation with a knob for control
- Features: Combines features of linear and switching power supplies
- Unique Feature: Smart combination of existing power sensing techniques
Product Usage Instructions
Safety Information
It is important to follow the safety instructions provided in the manual to
ensure safe operation of the HYPSOS power supply:
- Do not expose the unit to dripping or splashing liquids.
- Switch off and mute devices when connecting or disconnecting the power supply.
- Avoid allowing foreign objects to enter the enclosure.
- Keep the unit away from moisture and heat-producing appliances.
- Always use an earthed IEC power supply cable for connection.
- Unplug the unit during lightning storms or extended periods of non-use.
Operating Instructions
Follow these steps to operate the HYPSOS power supply:
- Ensure the power supply is connected to a suitable power outlet using the provided cable.
- Turn on the power supply using the designated switch or button.
- Adjust the power output using the knob to suit your device’s requirements.
- Monitor the device for any unusual behavior or warnings.
- When not in use, switch off the power supply and unplug it from the outlet.
FAQ
Q: What should I do if liquid spills into the unit?
A: Immediately disconnect the power cord from the wall outlet and have
the unit inspected by a qualified service person for necessary repairs.
Thank you for choosing HYPSOS!
HYPSOS is a hybrid power system that combines the best features of both linear
and switching power supplies. HYPSOS can power many brands with a simple
revolution of a knob? This software-based operation is unique to HYPSOS and an
industry-first! Apart from the ease of operation, HYPSOS makes use of a smart
combination of existing power sensing techniques, which again sets it apart
from the pack. With the HYPSOS power supply your audio system will be taken to
the next level!
HYPSOS by Ferrum
User Manual September 2024
© 2024
IMPORTANT SAFETY INFO
-
Warning: To reduce the risk of fire, electric shock or enclosure discoloration, be sure that the apparatus shall not be exposed to dripping or splashing and that no objects filled with liquids, such as vases, shall be placed near or on the apparatus.
-
Note: Always switch off and mute devices when connecting or disconnecting the HYPSOS power supply.
-
Do not allow any objects to get into the enclosure. If the unit is exposed to moisture, or a foreign object gets into the enclosure, immediately disconnect the power cord from the wall outlet. Take the unit to a qualified service person for inspection and necessary repairs.
-
Read all the instructions before connecting or operating the component. Keep this manual so you can refer to these safety instructions. Heed all warnings and safety information in these instructions. Follow all operating instructions.
-
Unplug this product from the wall outlet before cleaning. Do not use liquid cleaners or aerosol cleaners. Use a damp cloth for cleaning.
-
When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over.
-
Do not place the unit on a bed, sofa, rug, carpet, or similar surface that could block the heatsink airflow. If the component is placed in a bookcase or cabinet, there must be ventilation of the cabinet to allow proper cooling.
-
Keep the HYPSOS away from radiators, kettles, heat registers, stoves, or any other appliance that produces heat.
-
Connect the HYPSOS to the power outlet only with an earthed IEC power supply cable or an exact equivalent in a mains socket with protected earthing connection.
-
The safest and primary method of isolating the device from the mains supply is to disconnect the mains plug.
-
Ensure that the mains plug remains accessible at all times.
-
Unplug HYPSOS during lightning storms or when unused for long periods of time.
-
Do not attempt to defeat grounding and/or polarization provisions. Do not route the power cord where it will be crushed, pinched, bent at severe angles, exposed to heat, or damaged in any way. Pay particular attention to N the power cord at the plug and where it exits the back of the unit. Immediately unplug and stop using the component and have it inspected and/or serviced by a qualified service if:
-
the power supply cord or plugs have been damaged
-
objects have fallen or liquid has been spilled into the unit
-
the unit has been exposed to rain
-
the unit shows signs of improper operation
the unit has been dropped or damaged in any way -
when the product exhibits a distinct change in performance.
-
This indicates a need for service
- Warning: When replacement parts are required after the warranty period, be sure the service technician has used replacement parts specified by the manufacturer or have the same specification as the original part Unauthorized substitutions may result in fire, electric shock, or other hazards Upon completion of any service or repairs to this product, ask the service technician to perform safety checks to determine that the product is in proper operating condition
- Note: In households with small children, an adult should provide supervision until the child is capable of following all the rules essential for the safe operation of the unit
- Note: Only use DC cables specified by the manufacturer
BOX CONTENTS
- HYPSOS hybrid power system
- AC power cord
- DC power cord with 5.5/2.5 mm or 5.5/2.1 mm DC jack
- spare fuse
- quick guide
DEVICE FEATURES
- Regulated output voltage level in 5-30 V range, current up to 6 A, power up to 80 W
- Hybrid Power System (HYPSOS) design – linear/switching hybrid design to get the advantages from both techniques – low ripple and noise as well as fast transient response and high efficiency
- Sweet Spot Tuning – possibility to fine-tune the output voltage for the best sound 4-Terminal Sensing Design (4TSD) – ensuring the exact voltage level precisely at the point of the powered device DC input terminal – special cable design and feedback to ensure flat voltage at every moment
- Easy setup procedure – using pre-configured settings from the list of supported devices or setting custom parameters manually
- Advanced automation – trigger in/out connector; possibility to automate power-up of the devices with standby mode even without dedicated trigger connection
- Custom made audio-grade power transformer with double shielding
- Double-input AC filter
- Automatic Transformer Voltage Adjust (ATVA) and Electronic Output Voltage Polarity Switch
- Tamper-safe design – impossible to accidentally change the electrical settings (voltage, etc.)
- Overvoltage, current limit and short protection
- Compatibility and the best performance with all worldwide mains voltage parameters
- Each unit is unique thanks to corten plate on the front
HYPSOS OVERVIEW
Front Panel
- A. Ferrum logo – the brightness of the logo can be changed in the menu
- B. OLED displays
- C. Encoder knob – this encoder is both a knob and a button. Works as an on/off switch in standby mode and allows you to navigate in the HYPSOS menu. To put HYPSOS in standby mode press the knob for couple of seconds.
Back Panel
-
A. DC output – here you connect the DC cable. The DC output socket is marked with a red dot. The same dot is also marked on DC cable. To connect the cable properly both dots must be aligned. To disconnect the DC cable, pull the metal ring on the plug in the opposite direction to the device and then pull the cable out of
the socket. -
B. MAIN and AUX DC outputs – available only in HYPSOS Dual Output
C. trigger I/O socket -
D. Micro-USB port
-
E. main power switch
-
F. fuse
-
G. mains IEC connector – place mains power cord at this connector
Main Screen
- A. nominal voltage value set during the process of selecting a device from the list or during manual configuration
- B. measured voltage at the DC HYPSOS output – small deviations in measurement up to 0.2 V are possible
- C. current power consumption of the device powered by the HYPSOS
- D. currently measured output current on the DC HYPSOS output
- E. voltage adjustment (Sweet Spot Tuning) – this feature can also be set up in the menu
- F. menu
- G. Spread Spectrum Mode icon – when grayed out SSM is not active
- H. 4T-Sensing Design icon – when grayed out 4TSD is not active
- I. active position indicator
CONNECTING THE HYPOS
Note: Please connect all signal cables before connecting DC cable or switching on the HYPSOS.
GETTING STARTED
Turning on Your HYPSOS for the First Time
Make sure that all cables are correctly connected to the HYPSOS and powered
device (Fig. 5 or Fig. 6). Then use the main switch to start the HYPSOS (Fig.
2E).
The first time you start the HYPSOS, it needs to be configured to properly
power other devices.
Selecting a Device From the List
After start-up press the knob and HYPSOS will display a list of devices, which
have already configured presets.
If you see your device in the list, select it and confirm by pressing the
dial. HYPSOS will show you a summary of the preset and ask you to approve the
settings. It is a good idea to check if the voltage and polarity that HYPSOS
proposes are correct for the device you want to power.
Once the settings have been approved, a timer will appear on the screen
counting down the time to apply the voltage to the HYPSOS output – you still
have 9 seconds to change the settings if necessary. To stop the countdown and
return to the settings, press the knob.
After 9 seconds, the previously set voltage is applied to the DC HYPSOS
output.
Done!
Note: The list of available devices can be updated by updating the firmware.
Let us know if you want us to add a device that is not on the list.
Note: All presets included in HYPSOS are suggested settings only. Before
accepting a setting from a preset, the user must verify that it is correct for
the device they wish to power with HYPSOS. If there is a parameter mismatch
between a preset and the device you are powering, do not use the preset and
report it to us. Ferrum refuses every liability for damage to equipment due to
an incorrectly connected DC output voltage or wrong polarity.
Manual Configuration
If the device you want to power is not in the list, select “Manual
Configuration” and confirm by pressing the dial.
The first window allows you to select the appropriate polarity for your device. You can choose between two options:
- the middle pin of the power plug is the positive pole
- the middle pin of the power plug is the negative pole.
- After selecting the appropriate polarity, confirm your choice by pressing the dial. In the next window, select the voltage appropriate for powering your device. You can choose between 5 V and 30 V. Confirm your choice of voltage by pressing the dial. Warning: Above parameters should be set according to the recommendations of the manufacturer of the device you want to power! Ferrum refuses every liability for damage to equipment due to an incorrectly connected DC output voltage or wrong polarity.
- The HYPSOS will now show a summary of the settings and ask you to confirm them. Once the settings have been approved, a timer will appear on the screen counting down the time to apply the voltage to the HYPSOS output
- you still have 9 seconds to change the settings if necessary.
- To stop the countdown and return to the settings, press the knob.
- After 9 seconds, the previously set voltage is applied to the DC HYPSOS output.
Done!
MAIN and AUX DC Output Differences (for HYPSOS Dual Output)
The MAIN DC output utilizes all features that HYPSOS can provide so it is
most suitable for connecting devices that can draw variable amounts of current
– like headphone amplifiers or streaming servers.
The AUX DC output do not support 4TSD feature so it is more suitable for
connecting devices with more stable current draw like DACs and streaming
endpoints.
Note: If the HYPSOS Dual Output only powers one external device, use the MAIN
DC output of the HYPSOS to connect it. The AUX DC output should only be used
when connecting two devices simultaneously.
COMPATIBILITY OF VOLTAGE AND POLARITY
Important: Both MAIN and AUX DC outputs always have the same voltage and
polarity values. This means that both connected devices must support the same
voltage and polarity values (Fig. 9) and comply with the power supply scheme
set up in HYPSOS.
The total current drawn by the connected devices must not exceed 6A and the
total power drawn must not exceed 80W.
Warning: Do not simultaneously connect two devices that are not compatible in their voltage value and polarity (Fig. 10) to the HYPSOS Dual Output. This risks damaging the devices.
NAVIGATION AND MENU STRUCTURE
Navigation
To open the menu select Menu icon (Fig. 4F) on the screen by rotating the knob
(Fig. 1C) and then pressing it to confirm.
Use the knob to navigate through the menu.
To go back to the previous screen select “Back”.
Icons :
Means action. When you enter this item it will take you to another screen.
Indicates the information that is displayed on the left screen.
This will take you to previous screen.
80 ‰NO Shows the currently set parameter value on the button. When you
enter this item, you can change the value.
Menu structure
POWER OUTPUT
Current Device
Display the parameters of the currently powered device.
Reconfigure
This feature allows you to go through the initial setup process of selecting a
HYPSOS powered device from the list or manual configuration.
Voltage Adjustment
This function can also be set from the home screen (check Fig. 4E). Allows you
to fine-tune the output voltage to get the best sound on a device powered by
HYPSOS. The range in which the voltage can be adjusted will be different for
different devices. Some allow you to use a larger range. The standard “Voltage
Adjustment” range is 95% to 105% of nominal voltage for safety reasons. You
also cannot set the voltage lower than 5V or higher than 30V.
Warning: Please use this function with caution! Once you have decided to find
your sweet spot, you must confirm the start of the procedure
In the next step you can modify the voltage level. Now you have the option to increase or decrease the DC voltage.
Confirm the voltage level by pressing the knob. After 4 seconds, the newly set voltage will appear on the DC output.
You can interrupt the countdown by pressing the knob.
When the timer has finished the countdown simply push the knob to go back to
the main screen.
Note: Ferrum will not be held liable for damage to the device being powered when the voltage level you set will damage it.
-
Power in Standby ON/OFF
When turned on, the HYPSOS will continue to provide DC, even if it is in Standby mode. To return to the previous screen press the knob. -
Terminal Sensing ON/OFF
Possibility to turn on or off 4TSD (4-Terminal Sensing Design) – this technology results in more clarity and resolution,
where without the sound will be more weighted. To return to the previous screen press the knob. -
Spread Spectrum Mode ON/OFF
When turned on, switching frequency modulation is activated in the HYPSOS power switching circuit. This might influence the reproduction of high frequencies in some devices. To return to the previous screen press the knob. This button gives access to the functions of the device and the Standby button.
VISUALS
-
Fe Brightness
-
Akyws to charge the light intenSty of the Ferrum wren the HYFSOS is t’rre-d on There are 10 brightnes levels to ct’,cns-e from or you can tun off the tncklit
-
Standbv F-e
Akyws to the bght intensity of the Ferrum when tte HYPSOS is in standby! There are 5 &ightnes levels to ct’,cns-e from or you can tun off the tncklit -
Dtspbav Bnqhtness
Akyws to change tte luminosity are brightnæs Levels to from 79 Off
Akyws to ælect after which the will be switched off You can ælect from: disa&d, 3s, 5; 30s, 45; 60s, CX)s- The &fautt is -
Akyws you to æbect the return titre after which the diseay will go tnck to the main screen. sou can select from: cisabed, 3; 5s, IS K)s, 45s, 90s Tte defoutt is
-
TRIGGER 79.31 Inxt
When ælected, the TrigF input HYFSOS. This option might be æiected when you vant to turn on your system b/ external like arnpIi6er-
When tte optbn is selected, the outg’t wakes up the external devk:e This option be used wren
vant to wake up an external &vice, sæt’, as DAC, b/ turning on the HYPSOS
REMOTE PAIRING
Pairing procedure – Apple remote
Procedure can be done in two ways:
- The Apple remote can be paired exclusively with HYPSOS.
- The Apple remote can be paired with currently paired devices and with HYPSOS.
- If you want to pair the Apple remote exclusively with HYPSOS – Enter the “Remote pairing” procedure, then press and hold Menu and Select buttons over 5 seconds while pointing the remote control towards HYPSOS.
If you simply want to pair your Apple HYPSOS remote control, but want it to remember another device you’ve paired earlier – enter the “Remote pairing” procedure, then press and hold the Menu and Next buttons over 5 seconds while pointing the remote control towards the HYPSOS. If you want to interrupt the remote pairing process, press the knob.
- If you want to pair the Apple remote exclusively with HYPSOS – Enter the “Remote pairing” procedure, then press and hold Menu and Select buttons over 5 seconds while pointing the remote control towards HYPSOS.
FACTORY RESET
Allows you to restore HYPSOS to its factory settings. This process is
irreversible! The cross mark will take you back to the menu. Select the tick
mark to start the HYPSOS reset process.
INFORMATION
-
Contact
Here you will find information how to contact us. -
Firmware
Shows currently installed firmware version. Pressing the knob will start USB firmware update mode.Note: For more information on the firmware upgrade process, see paragraph “8. Firmware Update”. -
About product
Some information about motherboard version, motherboard serial number etc. -
Licenses
Licenses used to create HYPSOS software.
FIRMWARE UPDATE
To update the firmware, please download the Ferrum Control application.
- Note: For Windows it is also required to install the USB driver. For macOS, there is no need to install the driver.
- You can download the USB driver from our website: https://ferrum.audio/support/
- The Ferrum Control app is available in the Microsoft Store and in the App Store – a direct link is also available on our site: https://ferrum.audio/support/
- Open Ferrum Control app.
- Connect HYPSOS via micro USB cable to your computer and turn it on.
- In the menu of HYPSOS find the “Information” tab and select it by pushing the knob. Then find the “Firmware” tab and push the knob again.
- By using the knob, confirm you want to go into “USB update mode”.
- HYPSOS will be displayed in the Ferrum Control app.
- If the “Check for update“ button is visible click on it to check if there is new firmware available. Alternativelyyou will see the “Update now” button. Click on it and then click on the “Start update” button to begin the update procedure.
- The Ferrum Control application will inform you when the firmware update process is complete. Click on the “Close” button to close the update window.
- To return from “USB update mode” to normal HYPSOS operation click on the button. HYPSOS will reset and turn on with the last memorized settings.
FUSE REPLACEMENT
Fuse is located in the neighborhood of AC mains socket (Fig. 2F) To replace
the fuse you can use a flat screwdriver to remove the plastic enclosure where
fuse is hidden. Check
if the thin wire inside the fuse is intact. If it’s not intact, use a spare
fuse for replacement. Spare fuse is hidden inside the fuse enclosure (Fig.
25).
TECHNICAL SPECIFICATION
- Power Input: Factory configured 110-120/220-240 VAC ~50/60 Hz (EU/US version) or 100 VAC ~50/60 Hz (JP version)
- Output Voltage Range: 5-30 V
- Maximum Continuous Output Current (for DC VOUT below 13.3 V): 6 A
- Maximum Continuous Output Current (for DC VOUT higher than 13.3 V): IOUT [A] = 80 [W] / VOUT [V]
- Maximum Impulse Current: 9 A
- Maximum Impulse Power: DC VOUT* 9 A (270 W for 30 V)
- Maximum Continuous Output Power (for DC VOUT below 13.3 V): POUT [W] = VOUT [V] * 6 [A]
- Maximum Continuous Output Power (for DC VOUT higher than 13.3 V): 80 W
- Dimensions (W x D x H, without knob, feet and connectors): 21.75 cm x 20.6 cm x 5 cm / 8.6” x 8.1” x 2.0”
- Net weight: 3.1 kg / 6.8 lb
- Primary winding fuse (external): 5x20mm – slow blow 2 A 250 V for EU/US version, slow blow 3.15 A 250 Vfor JP version
- Secondary winding fuse (internal): first 4 A slow blow Littelfuse 154004.0T, second 8 A fast Littelfuse 154008.0
- Power Consumption (input 230 VAC 50 Hz, output 12 VDC)
- 6 VA (idle)
- 31 VA – (@ 15 W load)
- 98 VA – (@ 60 W load)
- 134 VA – (@ 80 W load)
WARRANTY
Each T’,drvidual HYPSOS uroergæs qualrty control and a corroete test before
gripping
This PSU is warranted-d by to tte against defecE in ard materials used in
rrunufæture for a period of three years from the of purchase If that your
prcxiuct is butty pleaæ contæt tte place of purchaæ or contact Prior warranty
ærvices or mast obtain an RMA nurnt*t from Ferrum for varranty Units sert
without an RMA will not accepted. Prcxyf of purctuse in form of a 011 of or
in-nice, is t’,at this prcxiuct is within warranty must be preænte-d to obtain
warranty serve. This warranty is void ard if the fo:tory applied serial has
been altered or defaced from this god’ct. Faults due to unauthoriæd acc&nts
are rot covered b/ this warranty
Pleaæ pack the prcxiuct •very careful” preferably in original to sure no
darrage can be done is not resgnrsibie for accesg)ries items left in the
pokaging and the box in whk:h the device has arrived for Ferrum the right to
uæ a replacement box.
CONTACT FERRUM
In case of questions, problems or suggestions regarding its form or contents, please contact us via our support system available on our website: https://ferrum.audio/support/
WARNING
- Excessive sound pressure from speakers and headphones can cause hearing loss. In order to use this product safely, avoid prolonged listening at excessive sound pressure levels.
- This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
- This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications.
- You are cautioned that any changes or modifications not expressly approved in this manual could void your authority to operate this equipment.
- All interface cables used to connect peripherals must be shielded in order to comply with the limits for a digital device pursuant to Subpart B of Part 15 of FCC Rules.
- This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
- This device may not cause harmful interference, and
- This device must accept any interference received, including interference that may cause undesired operation.
This product with the CE marking complies with the EMC Directive issued by the Commission of the European Community. Compliance with this directive implies conformity to the following European standards:
Safety
- IEC 62368-1:2014 Additionally evaluated to: EN 62368-1:2014, EN 62368-1:2014/A11:2017 EMC
- CISPR 32:2015, CISPR 35:2016, IEC 61000-3-3:2013, IEC 61000-3-3:2013/AMD1:2017, IEC 61000-3-2:2018, CISPR 32:2015/AMD 1:2019
- Additionally evaluated to: EN 55032:2015/A11:2020, EN 55032:2015/A1:2020, EN 55032:2015, EN 55035:2017 and 47CFR PART 15B, ICES-003 (ISSUE 7)
- This product is intended for use in the following Electromagnetic Environments: E1 (residential), E2 (commercial and light industrial), E4 (controlled EMC environment, ex. TV studio).
INFORMATION ON DISPOSAL FOR USERS OF WASTE ELECTRICAL & ELECTRONIC EQUIPMENT (PRIVATE HOUSEHOLDS)
The Wheelie Bin symbol on the products and/or accompanying documents means
that used electrical and electronic products should not be mixed with general
household waste. Disposing of this product correctly will help save valuable
resources and prevent any potential negative effects on human health and the
environment.
To properly dispose harmful substances and recycle the product, the user is
obliged to return it at the point of collection of electrical and electronic
equipment waste. For more information please contact your local authorities,
waste disposal units or retailer.