EBECO Frostvakt 25 Heating Cable 30m Drainpipes Self Adjusting User Manual
- June 12, 2024
- EBECO
Table of Contents
**EBECO Frostvakt 25 Heating Cable 30m Drainpipes Self Adjusting User Manual
![Heating Cable 30m Drainpipes Self
Adjusting](https://manuals.plus/wp-
content/uploads/2023/08/Screenshot_1-879.png)
**
Welcome
Thank you for choosing Ebeco. For the guarantee
to be valid, the product must be installed and
operated as indicated in this manual. This means it is
extremely important that you read the entire manual
If you have any questions, you are always more than welcome to contact Ebeco. Call +46 (0) 31 707 75 50 or send an e-mail : to support@ebeco.se. Feel free to visit : ebeco.com for more information.
Technical specifications
Art. no | Power | Length |
---|---|---|
89 604 71 | 125 W | 5 m |
89 604 72 | 200 W | 8 m |
89 604 73 | 300 W | 12 m |
89 604 74 | 400 W | 16 m |
89 604 75 | 500 W | 20 m |
89 604 76 | 625 W | 25 m |
89 604 77 | 750 W | 30 m |
The power is stated at +10 °C
Voltage: 230 V Fuse: min 10 AC characteristic
Important
- The cable is self-regulating which means that it never overheats. The heat can be limited when required, which means the cable can be crossed.
- The heating cable is not dimensioned for thawing ice. It must therefore be connected before the gutter freezes.
- The Frost Guard may only be covered with material that withstands + 65 °C and warmer.
- Roll up the connection cable if it is too long.
- The connection must not be replaced. If damaged, the entire frost guard must be disposed of.
- The Frost Guard must always be connected via an earth fault relay.
- Max. fuse size is 16 A.
- Min. bend radius is 35 mm.
Installation
Temporary installation
The cable is connected to a 230V earthed power socket. Permanent
installation: Box with strain relief connector must be used and the
installation must be performed in compliance with electrical installation
regulations.
Gutters/ drainpipes
Frost Guard 25 is fitted to the gutter using Ebeco Clip (A), art. no.
E8960971. The Mounting bracket (B), art. no. E8960962, must be used where the
cable goes from the gutter to the drainpipe. Note that the melted water must
be drained off to a frost free area. If the drainpipe has a shoe, the cable
must be folded double the final 50 cm.
Heating pump
The cable is mounted to the plate to prevent the condensed water from
freezing. A suitable c-c distance for the cable is 10 cm. Secure the cable
with Limpatron T-18, article no. E1647218.
Thicker pipes
The Frost Guard 25 can be used externally on pipes with a Ø of 75 mm or
larger. Example: Ø 110 mm pipe with 20 mm insulation can cope with -30°C.
Smaller pipes are frost protected with Frost Guard 10, which gives a lower
power output. Use electrical tape (C) to secure the cable on the pipe. Always
insulate the pipe with appropriate insulation (D). Excess cable can be wound
around the pipe.
**2 years warranty
**