LASER 5263 Logic Probe DC
Product Information
Product: Logic Probe
Part No.: 5263
Manufacturer: The Tool Connection Ltd
EU Authorised Representative: Comply Express Unipessoal Limitada, StartUp Madeira, EV141, Campus da Penteada, 9020 105 Funchal, Portugal
Website: www.lasertools.co.uk
The Logic Probe is a troubleshooting instrument designed to display visual (LED) and audio indications for logic levels (Boolean 0 or 1) and pulses. It can also capture positive or negative events as short as 30 nanoseconds. The unit is powered by the circuit under test.
Product Features
- Probe with red high LED and green low LED
- TTL / CMOS switch for selecting logic type
- Yellow LED for pulse capture or memory
- PULSE/MEM switch for selecting operation mode
- Black clip for ground connection
- Red clip for Vcc connection
Product Specifications
- Power Supply: 20V DC / AC
- Maximum Input Voltage: 40V DC / AC (duration < 15 seconds)
- Maximum Input Signal Frequency: 20MHz
- Input Impedance: 1M
- Pulse Indicator Flash Time: 500mS
- Operating Temperature: (not specified)
- Storage Temperature: (not specified)
Product Usage Instructions
- Connect the black clip to the ground or the common of the circuit to be tested.
- Connect the red clip to the Vcc of the circuit to be tested.
- Select either TTL or CMOS mode according to the logic type to be tested. For pulse or logic level testing, set the PULSE/MEM switch to PULSE position.
- Touch the probe tip to the circuit point to be tested. The unit will give LED and sound indications indicating the logic level or signals. Refer to the table below for LED and buzzer indications.
- To capture a positive or negative pulse, set the PULSE/MEM switch to the MEM position. The yellow LED will light and will not turn off until the switch is set back to PULSE position.
LED and Buzzer Indications
Input Signal Level | LED Indication | Buzzer |
---|---|---|
Logic: 1 | High (Red) LED ON | Fixed tone |
Logic: 0 | Bad logic level or open circuit | No tone |
Square wave < 200Hz | High and Low LEDs blink at a frequency rate | Variable |
tone at a frequency rate
Square wave > 200Hz| High and Low LEDs may or may not be ON| Variable tone at
a frequency rate
Narrow high pulse (pulse duty cycle)| High LED ON| Variable tone at a
frequency rate
Narrow low pulse (pulse duty cycle)| Low LED ON| Variable tone at a frequency
rate
Minimum Detectable Pulse Width
-
Frequency: 1kHz
-
Minimum Pulse Width: 100ns
-
Frequency: 1k ~ 20kHz
-
Minimum Pulse Width: 50ns
-
Frequency: 20k ~ 20MHz
-
Minimum Pulse Width: 30ns
Product Precautions
- Before use, verify the logic probe’s operation by measuring known signals.
Note: Operating temperature and storage temperature are not specified in the user manual. For more information, please visit the product’s website: www.lasertools.co.uk
Logic Probe
Designed as a logic troubleshooting instrument which displays visual (LED) and audio indications for logic levels (Boolean 0 or 1) and pulses. It can also capture positive or negative events as short as 30 nanoseconds. The unit is powered by the circuit under test.
-
Probe
-
High LED (red)
-
Low LED (green)
-
TTL / CMOS switch
-
Yellow LED (Note: If the
PULSE/MEM switch is in the MEM position and the unit captures a positive or negative pulse, the yellow LED will light and does not turn off until the PULSE/MEM switch is set to PULSE position. -
PULSE/MEM switch
(Note: there are two positions for this switch:
PULSE: normal operation mode for pulse or level detection.
MEM: pulse capture or memory. -
Black clip: should be connected to ground or common of the circuit to be tested.
-
Red clip: should be connected to the Vcc of circuit to be tested.
Instructions
- Connect the black clip to ground or common of the circuit to be tested. Connect the red clip to the Vcc of the circuit.
- Select either TTL (transistor-transistor logic) or CMOS (complementary metallic oxide semiconductor), according to the logic type to be tested. (Note: TTL level is nominal 0 to 5V DC and CMOS levels are 0 to 5-15V DC. For pulse or logic level testing, set the PULSE/MEM switch to PULSE position.
- Touch the probe tip to the circuit point to be tested. The unit will give LED and sound indications indicating the logic level or signals. (See table.)
- Setting the PULSE/MEM switch to MEM position allows the unit to capture a positive or negative pulse – the yellow LED will light and does not turn off until the switch is set to PULSE position.
Input
Signal
| Level| LED
Indication
| Buzzer
---|---|---|---
Logic: 1
| TTL: > 2.3V ± .02V DC CMOS: > 70% Vcc
± 10%
| High: (Red) ON High: (Red) ON| Fixed tone Fixed tone
Logic: 0| TTL: < .08V ± .02V DC CMOS: < 30% Vcc ± 10%| Low: (Green) ON
Low: (Green) ON| Fixed tone Fixed tone
Bad logic level or open circuit| | ****
None
| ****
No tone
Square wave| ****
< 200Hz
| High and Low blinks at
frequency rate
| Variable tone at a frequency rate
Square wave| ****
200Hz
| High and low may or may not be ON| Variable tone at a frequency rate
Narrow high pulse
| ****
TTL: > 2.3V ± .02V DC CMOS: > 70% Vcc ± 10%
| Low blinking intensity depends on the pulse duty cycle| ****
Variable tone at a frequency rate
Narrow low pulse
| ****
TTL: < .08V ± .02V DC CMOS: < 30% Vcc ± 10%
| High blinking intensity depends on a pulse duty cycle| ****
Variable tone at a frequency rate
Minimum Detectable Pulse Width
Frequency | 1kHz | 1k ~ 20kHz | 20k ~ 20MHz |
---|---|---|---|
Minimum Pulse Width | 100ns | 50ns | 30ns |
Tip: Before use, verify the logic probe’s operation by measuring known signals.
Precautions
- Do not use if the unit is damaged or operates abnormally.
- Take care not to ground yourself when using the unit.
- To avoid electric shock, do not touch any bare conductors, pins or terminals.
- Do not input more than 40V AC or DC or the unit will be damaged.
- Spark danger — do not use near explosive gas or vapor.
Electrical Specifications
- Power Supply: 5 – 15V DC
- Power Supply Protection: 20V DC / AC
- Maximum Input Voltage: 40V DC / AC (duration < 15 seconds)
- Maximum Input Signal Frequency: 20MHz
- Input Impedance: 1MΩ
- Pulse Indicator Flash Time: 500mS
- Operating Temperature: 0 – 40°C (relative humidity < 80%)
- Storage Temperature: -20 – 50°C (relative humidity < 85%)
Guarantee
- If this product fails through faulty materials or workmanship, contact our service department direct on: +44 (O) 1926 818186. Normal wear and tear are excluded as are consumable items and abuse.
- When you have finished with this leaflet please recycle it
Distributed by The Tool Connection Ltd
- Kineton Road, Southam, Warwickshire CV47 ODR
- T +44 (0) 1926 815000 F +44 (0) 1926 815888
- info@toolconnection.co.uk. www.toolconnection.co.uk.
Manufacturer: The Tool Connection Ltd
- EU Authorised Representative: Comply Express Unipessoal Limitada,
- StartUp Madeira, EV141, Campus da Penteada, 9020 105 Funchal, Portugal
- www.lasertools.co.uk.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>