GENIE 1294905GT Lift Connect Telematics Ready Connector Owner’s Manual

June 12, 2024
GENIE

Service Manual Supplement
Lift Connect™
Telematics Ready Connector
Part No. 1294905GT
Rev B
December 2021

Introduction

Important
The purpose of this document is to provide device connections for OEM Telematics providers.
Read, understand and obey the safety rules and operating instructions.
This manual provides detailed information for the machine owner and Telematics provider.
Compliance
Wireless Certifications

  • Telematic device(s) should comply with specific wireless carrier certifications where applicable and comply with the following:
    • N. America – PTCRB, FCC/IC
    • Europe – CE, RED 2014/53/EU

  • Owners must verify the RF safety compliance in accordance with the Telematics device certifications.

Technical Publications
Genie has endeavored to deliver the highest degree of accuracy possible. However, continuous improvement of our products is a Genie policy.
Therefore, product specifications are subject to change without notice.
Readers are encouraged to notify Genie of errors and send in suggestions for improvement. All communications will be carefully considered for future printings of this and all other manuals.
Contact Us:
Internet: www.genielift.com
E-mail: awp.techpub@terex.com
Copyright © 2019 by Terex Corporation
1294905GT Rev A.01, November 2020
First Edition, Second Printing
Genie, “S” and “Z” are registered trademarks of Terex South Dakota, Inc. in the U.S.A. and many other countries.
“AL”, “GR”, “GRC”, “GS”, “GTH”, “RL”, “SX”, “TraX”, “TZ”, “QS”, and “XC” are trademarks of Terex South Dakota, Inc.
Lift Connect is a trademark of Terex South Dakota.

Revision History

Revision Date Section Procedure / Page / Description
A 2/2019 Initial Release
B 12/2021 1\0 Specifications Add legacy 8 pin TRC information
TRC Function Pin Out Add note for GS, GR, GRC and QS models

Safety Rules

General Safety

This machine is equipped with a connection for a telematics device. If a telematics device has been installed, additional information may need to be communicated to those that operate or service this machine and possibly the general  public.
Communications that need to be considered include:

  • A hazard decal warning of the specific hazards related to the radio frequency exposure and the required steps to take so as to avoid them. This could apply to the operator, service personnel or even the general public.
  • Additional operator and service training regarding the potential hazard.

If a telematics device has been installed, before placing the machine into service, it is the owners’ responsibility to clearly understand the installed telematics device as it relates to its performance and market compliance and to ensure that the necessary steps have been taken to inform and train operators, service personnel and the general public (when applicable) regarding the potential hazards related to radio frequency exposure and how to avoid them.
Telematic devices are not approved for use on Genie models equipped with an EE rating.
Installing a Telematics device on an EE rated machine will invalidate the machine’s EE rating.

Telematics Ready Connector
The telematics connector installed on all Genie machines starting in 2019 is a 12 pin Deutsch DT series panel mount receptacle. Depending on the equipment it may be an in-line receptacle.

Telematics Device Connector
OEM suppliers can connect their telematic devices by equipping it with a 12 pin Deutsch plug.

Telematics I/O Specifications

Telematics Ready Connector Components
Genie Telematics Ready Connector parts and tools are available through Genie Parts Sales.

Website: http://www.genielift.com 
Phone: 877-367-5606
Email: AWP.PartsSalesPO@terex.com
54255GT Receptacle lock, 12 pin (used with p/n 73730GT and 119070GT)
--- ---
60435GT Plug lock, 12 pin, 14-18 GA (used with p/n 119061)
61794GT Deutsch Crimper
73713GT Terminal Pin, 16-18 GA (used with p/n 73730GT and 119070GT)
73714GT Terminal Socket, 16-18 GA (used with p/n 119061)
73730GT Receptacle connector, Panel Mount, 12 pin, 14-18 GA
119061GT Plug connector, 12 pin, 14-18 GA
119070GT Receptacle connector, In Line, 12 pin, 1418 GA

Telematics Ready Connector Function Pin Out
Refer to the TRC I/O map to capture machine function states including the remote disable feature.
Unavailable I/O
Some Genie models do not support all of the discrete outputs. If a particular circuit feature is not available, it shall be left unconnected. There shall be no substitution or other optional wiring.
Refer to the appropriate TRC Function Pin Out for your model.

Basic TRC Connector I/O Map

Connector
Pin-out| Circuit Type| Circuit
Properties| Genie Machine Function(s)| Telematics Use Case
---|---|---|---|---
1| System Power| 12, 24 VDC| Battery Positive — constant power| Supply power to device
5 Amp Max. allowed draw
2| System Ground| 0 VDC| Battery Negative| Device ground
3| BND Control| 0 VDC| Chassis Ground| BND switch ground(customer installed option)
4| Digital Output 1| 12, 24 VDC| IC Engine Run,
12V = engine run, OV = engine off DC Motor Controller Enable
24V = enabled, OV = disabled| Monitor engine run hours (Engine powered models) Monitor machine run hours (Battery powered Models)
5| Digital Output 2| 12, 24 VDC| Key Switch Activation 12/24V = key switch on| Monitor machine utilization
6| Digital Output 3| 12, 24 VDC| Platform / Boom angle stowed status
12/24V = stowed, OV = out of stow 12/24V = boom >55°, OV = < 55°| Monitor platform stowed and out of stowed status
Monitor boom angle status (GTH models)
7| Digital Input 1| 12, 24 VDC| Remote Machine Disable Active Low Relay| Remote disable engine start
8| No Connection| X| X| X
9| No Connection| X| X| X
10| Digital Output 4| 12, 24 VDC| Foot Switch Activation 12/24V = foot switch pressed| Monitor machine utilization
11| Databus H| CAN HIGH| CAN/J1939| SAE J1939 Messages
12| Databus L| CAN LOW| CAN/J1939| SAE J1939 Messages

Genie models produced between 2015 –2019 may be equipped with an 8 pin Telematics Ready Connector. These machines will require an adapter harness to convert from a 12 pin telematics device to the 8 pin connector.
Refer to the Lift Connect Installation Instructions to determine the correct adapter harness for your machine.
Genie part number 1295251GT.

Legacy Telematics Ready Connector
The legacy telematics connector installed on Genie machines is an 8 pin Deutsch DT series panel mount receptacle. Depending on the equipment it may be an in-line receptacle.

Legacy Telematics Device Connector
OEM suppliers can connect their telematic devices by equipping it with a 8 pin Deutsch plug.

Telematics Adapter Harness Pin Out
Refer to the TRC I/O map to capture machine function states including the remote disable feature.
Unavailable I/O
Some Genie models do not support all of the discrete outputs. If a particular circuit feature is not available, it shall be left unconnected. There shall be no substitution or other optional wiring.
Refer to the appropriate TRC Function Pin Out for your model.
Legacy 8 pin TRC to 12 pin TRC wiring guide

8 pin TRC pin out| Wiring
connection| 12 pin TRC pin out
---|---|---
1 – System Power| | 1 – System Power
2 – System Ground
(connect to pins 2 and 3 on 12 pin TRC)| | 2 – System Ground
| 3 – BND Ground
3 – Equipment run| | 4 – Equipment run
4 – Key switch| | 5 – Key switch
5 – Model specific
(depending on model, this will connect to pin
6 or pin 10 of the 12 pin TRC)| | 6 – Boom \ Platform stowed status
6 – Model specific disable| | 7 – Model specific disable
| | 8 – No Connection
9 – No Connection
(refer to pin 5)| | 10 – Foot switch / Function enable or GTH parking brake
7 – CAN HIGH| | 11 – CAN HIGH
8 – CAN LOW| | 12 – CAN LOW

GR, GRC, QS, Slab Scissor and Z Boom Models
This Legend Only Applies to the Following Genie Models

GS-1330m GS-1532 GS-2046 GS-2669 GR-12 QS-12 Z-33/18
GS-1530 GS-1932 GS-2646 GS-3369 GR-15 QS-15 Z-40/23
GS-1930 GS-2032 GS-2646 AV GS-4069 GR-20 QS-20 Z-60/37
GS-2632 GS-3246 (DC – Bi Energy) GRC-12
GS-3232 GS-4047

Note: GS, GR, GRC and QS models require the installation of the Telematics harness to be Telematics ready.
Genie part number 1289899GT.

Pin| Circuit Type| Circuit Properties| Genie Machine Function(s)| Telematics Use Case
---|---|---|---|---
1| System Power| 24 VDC| Battery Positive — constant power| Supply power to device
5 Amp Max. allowed draw
2| System Ground| 0 VDC| Battery Negative| Device ground
3| BND Control| 0 VDC| Chassis Ground| BND switch ground (customer installed option)
4| Digital Output 1| 24 VDC| DC Motor Controller Enable 24V = enabled, OV = disabled| Monitor machine run hours
5| Digital Output 2| 24 VDC| Key Switch Activation 24V = key switch on| Monitor machine utilization
6| No Connection| X| X| X
7| Digital Input 1| 24 VDC (Z-60/37 Models)| Remote Machine Disable Active Low Relay| Remote disable motor controller
8| No Connection| X| X| X
9| No Connection| X| X| X
10| Digital Output 4| 24 VDC (Z-60/37 Models)| Foot Switch Activation| Monitor machine utilization
11| Databus H| CAN HIGH| CAN/J1939| SAE J1939 Messages
12| Databus L| CAN HIGH| CAN/J1939| SAE J1939 Messages

TRC Function Pin Out

GS-69 RT, GS-84 RT and GS-90 RT Models
This Legend Only Applies to the Following Genie Models

GS-2669 RT GS-3384 RT GS-3390 RT
GS-3369 RT GS-4390 RT
GS-4069 RT GS-5390 RT

Pin| Circuit Type| Circuit Properties| Genie Machine Function(s)| Telematics Use Case
---|---|---|---|---
1| System Power| 12 VDC| Battery Positive — constant power| Supply power to device
5 Amp Max. allowed draw
2| System Ground| 0 VDC| Battery Negative| Device ground
3| BND Control| 0 VDC| Chassis Ground| BND switch ground (customer installed option)
4| Digital Output 1| 12 VDC| IC Engine Run
12V = engine run, OV = engine off| Monitor engine run hours
5| Digital Output 2| 12 VDC| Key Switch Activation 12V = key switch on| Monitor machine utilization
6| Digital Output 3| 12 VDC| Platform Stowed Status
12V = stowed, OV = out of stow| Monitor platform stowed and out of stowed status
7| Digital Input 1| 12 VDC| Remote Machine Disable Active Low Relay| Remote disable engine start
8| No Connection| X| X| X
9| No Connection| X| X| X
10| No Connection| X| X| X
11| Databus H| CAN HIGH| CAN/J1939| SAE J1939 Messages
12| Databus L| CAN HIGH| CAN/J1939| SAE J1939 Messages

Remote Disable Engine Start Relay Configuration
Telematics Active Low

  1. Ignition Start Input
  2. Relay
  3. Telematics with Active Low input
Z-30/20N Z-45/25 DC
Z-30/20N RJ Z-45/25J DC
Z-34/22 DC

Pin| Circuit Type| Circuit Properties| Genie Machine Function(s)| Telematics Use Case
---|---|---|---|---
1| System Power| 24 VDC| Battery Positive — constant power| Supply power to device
5 Amp Max. allowed draw
2| System Ground| 0 VDC| Battery Negative| Device ground
3| BND Control| 0 VDC| Chassis Ground| BND switch ground (customer installed option)
4| Digital Output 1| 24 VDC| DC Motor Controller Enable 24V = enabled, OV = disabled| Monitor machine run hours
5| Digital Output 2| 24 VDC| Key Switch Activation 24V = key switch on| Monitor machine utilization
6| Digital Output 3| 24 VDC| Boom Stowed Status
24V = stowed, OV = out of stow| Monitor platform stowed and out of stowed status
7| Digital Input 1| 24 VDC| Remote Machine Disable Active Low Relay| Remote disable motor controller
8| No Connection| X| X| X
9| No Connection| X| X| X
10| Digital Output 4| 24 VDC| Foot Switch Activation 24V = foot switch pressed| Monitor machine utilization
11| No Connection| X| X| X
12| No Connection| X| X| X

Remote Disable Machine Relay Configuration
Telematics Active Low

  1. Foot switch Input
  2. Relay
  3. Telematics with Active Low input

Z Booms, ALC-500 and Bi-Energy Models
This Legend Only Applies to the Following Genie Models

ALC-500 all other models
Z-45/25 Z-34/22 (Bi-Energy)
Z-45/25J Z-34/22 (IC)
Z-45/25 XC Z-45/25 (Bi-Energy)
Z-51/30
Z-62/40

Pin| Circuit Type| Circuit Properties| Genie Machine Function(s)| Telematics Use Case
---|---|---|---|---
1| System Power| 12, 24 VDC| Battery Positive — constant power| Supply power to device
5 Amp Max. allowed draw
2| System Ground| 0 VDC| Battery Negative| Device ground
3| BND Control| 0 VDC| Chassis Ground| BND switch ground (customer installed option)
4| Digital Output 1| 12 VDC| IC Engine Run
12V = engine run, OV = engine off| Monitor engine run hours
5| Digital Output 2| 12, 24 VDC| Key Switch Activation 12/24V = key switch on| Monitor machine utilization
6| Digital Output 3| 12, 24 VDC| Boom Stowed Status
12/24V = stowed, OV = out of stow| Monitor platform stowed and out of stowed status
7| Digital Input 1| 12, 24 VDC| Remote Machine Disable Active Low Relay| Remote disable engine start
8| No Connection| X| X| X
9| No Connection| X| X| X
10| Digital Output 4| 12, 24 VDC| Foot Switch Activation 12/24V = foot switch pressed| Monitor machine utilization
11| Databus H| CAN HIGH| CAN/J1939| Receive Proprietary Genie Telematics Message
12| Databus L| CAN LOW| CAN/J1939| Receive Proprietary Genie Telematics Message

Remote Disable Engine Start Relay Configuration
Telematics Active Low

  1. Ignition Start Input
  2. Relay
  3. Telematics with Active Low input

S and Z Booms, ALC-600 Models
This Legend Only Applies to the Following Genie Models

S-40 XC S-60 XC S-80 XC
S-45 XC S-65 XC S-85 XC
S-80 HF
S-85 HF

Pin| Circuit Type| Circuit Properties| Genie Machine Function(s)| Telematics Use Case
---|---|---|---|---
1| System Power| 12 VDC| Battery Positive — constant power| Supply power to device
5 Amp Max. allowed draw
2| System Ground| 0 VDC| Battery Negative| Device ground
3| BND Control| 0 VDC| Chassis Ground| BND switch ground (customer installed option)
4| Digital Output 1| 12 VDC| IC Engine Run
12V = engine run, OV = engine off| Monitor engine run hours
5| Digital Output 2| 12 VDC| Key Switch Activation 12V = key switch on| Monitor machine utilization
6| No Connection| X| X| X
7| Digital Input 1| 12 VDC| Remote Machine Disable Active Low Relay| Remote disable engine start
8| No Connection| X| X| X
9| No Connection| X| X| X
10| Digital Output 4| | Foot Switch Activation 12V = foot switch pressed| Monitor machine utilization
11| Databus H| CAN HIGH| CAN/J1939| Receive Proprietary Genie Telematics Message
12| Databus L| CAN LOW| CAN/J1939| Receive Proprietary Genie Telematics Message

Remote Disable Engine Start Relay Configuration

  1. Ignition Start Input
  2. Relay
  3. Telematics with Active Low input

TZ Models
This Legend Only Applies to the Following Genie Models

TZ-34/20 TZ-50

Pin| Circuit Type| Circuit Properties| Genie Machine Function(s)| Telematics Use Case
---|---|---|---|---
1| System Power| 24 VDC| Battery Positive — constant power| Supply power to device
5 Amp Max. allowed draw
2| System Ground| 0 VDC| Battery Negative| Device ground
3| BND Control| 0 VDC| Chassis Ground| BND switch ground (customer installed option)
4| Digital Output 1| 24 VDC| DC Motor Controller Enable 24V = enabled, OV = disabled| Monitor machine run hours
5| Digital Output 2| 24 VDC| Key Switch Activation 24V = key switch on| Monitor machine utilization
6| Digital Output 3| 24 VDC| Boom Stowed Status
24V = stowed, OV = out of stow| Monitor platform stowed and out of stowed status
7| Digital Input 1| 24 VDC| Remote Machine Disable Active Low Relay| Remote disable motor controller
8| No Connection| X| X| X
9| No Connection| X| X| X
10| No Connection| X| X| X
11| No Connection| X| X| X
12| No Connection| X| X| X

www.genielift.com

Documents / Resources

| GENIE 1294905GT Lift Connect Telematics Ready Connector [pdf] Owner's Manual
1294905GT Lift Connect Telematics Ready Connector, 1294905GT, Lift Connect Telematics Ready Connector, Telematics Ready Connector, Ready Connector, Connector
---|---

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals