OSRAM SubstiTUBE Value T8 LED Tubes Instruction Manual
- June 12, 2024
- OSRAM
Table of Contents
OSRAM SubstiTUBE Value T8 LED Tubes
Product Information
The LEDTUBE T8 EM VAL is a LED replacement for conventional T8 fluorescent tubes. It comes in three different variants:
- LEDTUBE T8 EM VAL 600 6.6W – Suitable for 0.6m (18W) fluorescent tubes
- LEDTUBE T8 EM VAL 1200 15W – Suitable for 1.2m (36W) fluorescent tubes
- LEDTUBE T8 EM VAL 1500 18.3W – Suitable for 1.5m (58W) fluorescent tubes
This product is manufactured by LEDVANCE GmbH and has the following specifications:
- Maximum case temperature (Tc): Not specified in the extract
- Storage temperature (Ts): Not specified in the extract
- Ambient temperature (Ta): Not specified in the extract
Please refer to the complete user manual for detailed information on these specifications.
Product Usage Instructions
To replace a conventional T8 fluorescent tube with the LEDTUBE T8 EM VAL, follow these steps:
- Ensure that the power supply to the luminaire is turned off.
- Remove the existing T8 fluorescent tube from the luminaire.
- Insert the corresponding LEDTUBE T8 EM VAL into the luminaire, making sure it is securely fitted.
- Turn on the power supply to the luminaire.
Note: The LEDTUBE T8 EM VAL is suitable for use in dry conditions or in a luminaire that provides protection. It is not suitable for dimming, emergency operation, or use with a starter. Please refer to the user manual for any additional usage instructions or restrictions.
For more information about the product, you can visit the manufacturer’s website at www.ledvance.com.
Manufacturer details:
LEDVANCE GmbH Steinerne Furt 62 86167 Augsburg, Germany LEDVANCE Ltd Aquila House Delta Crescent Westbrook, Warrington WA5 7NR, United Kingdom
contents
INSTALLATION
This lamp is designed for general lighting service (excluding for example explosive atmospheres). Since only lamp and starter are replaced there is no constructive modification to the luminaire. This lamp may not be suitable for use in all applications where a traditional fluorescent lamp has been used. The temperature range of this lamp is more restricted. In cases of doubt regarding the suitability of the application the manufacturer of this lamp should be consulted.
- Replacement of conventional T8 fluorescent tube on CCG.
- Maximum case temperature.
- Storage temperature.
- Ambient temperature.
- Lamp to be used in dry conditions or in a luminaire that provides protection.
- Lamp suitable for 50 Hz or 60 Hz operation.
- Lamp not suitable for emergency operation.
- Dimming not allowed.
- LED replacement starter.
SPECIFICATION
| Replacement of conventional T8 fluorescent tube on CCG 1)|
Maximum case temperature 2) (Tc)| Storage temperature 3)
(Ts)| Ambient temperature 4) (Ta)
---|---|---|---|---
LEDTUBE T8 EM VAL 600 6.6W 830|
0.6 m = 18 W (a + b)
|
65°C
|
-20° … 80°C
|
-20° … 45°C
LEDTUBE T8 EM VAL 600 6.6W 840
LEDTUBE T8 EM VAL 600 6.6W 865
LEDTUBE T8 EM VAL 1200 15W 830|
1.2 m = 36 W (a)
LEDTUBE T8 EM VAL 1200 15W 840
LEDTUBE T8 EM VAL 1200 15W 865
LEDTUBE T8 EM VAL 1500 18.3W 830|
1.5 m = 58 W (a)
LEDTUBE T8 EM VAL 1500 18.3W 840
LEDTUBE T8 EM VAL 1500 18.3W 865
LEDVANCE GmbH Steinerne Furt 62 86167 Augsburg, Germany
www.ledvance.com
LEDVANCE Ltd, Aquila House Delta Crescent, Westbrook, Warrington WA5 7NR,
United Kingdom
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>