Product Information

The Ubbink XTRA LV pond pumps are high-quality and reliable products that use synchronous technology. They are designed for use in garden ponds, and fountain basins, and can be combined with items such as fountain jets and gargoyle spouts. The pumps come in three different models: Xtra 350 LV, Xtra 1000 LV, and Xtra 1600 LV. Each model has specific specifications and features.

Xtra 350 LV:

  • Power Supply: 230 VAC / 50 Hz
  • Maximum Flow Rate : 350 l/h
  • Power Consumption: 5 W
  • Maximum Head Height: 0.40 m
  • Flow Adjuster: Tap 3/8
  • Spray Nozzles: Vulcano
  • Pipe Extension : Hose connector 3/8 – 9 mm

Xtra 1000 LV:

  • Power Supply: 230 VAC / 50 Hz
  • Maximum Flow Rate: 1000 l/h
  • Power Consumption: 23 W
  • Maximum Head Height: 1.80 m
  • Flow Adjuster: T-piece
  • Spray Nozzles: Vulcano Lava
  • Pipe Extension : Hose connector 1/2 x 9 mm, 1/2 x 13 mm, 1/2 x 19 mm

Xtra 1600 LV:

  • Power Supply: 230 VAC / 50 Hz
  • Maximum Flow Rate: 1750 l/h
  • Power Consumption: 43 W
  • Maximum Head Height: 1.90 m
  • Flow Adjuster: T-piece
  • Spray Nozzles: Vulcano Lava
  • Pipe Extension: Hose connector 1/2 x 9 mm, 1/2 x 19 mm, 9 mm T-piece

Product Usage Instructions

  1. Before using the Ubbink pond pumps, ensure that all packaging parts are removed and kept out of the reach of children and pets.
  2. Connect the power supply of the pump according to the specified voltage and frequency (230 VAC / 50 Hz).
  3. Choose the appropriate model of the pump based on your pond size and requirements.
  4. Install the pump in the desired location, such as a garden pond or fountain basin.
  5. Use the flow adjuster (Tap 3/8 for Xtra 350 LV, T-piece for Xtra 1000 LV and Xtra 1600 LV) to adjust the flow rate of the pump.
  6. Attach the spray nozzles (Vulcano or Vulcano Lava) to create desired fountain effects.
  7. Use the pipe extensions and hose connectors to connect the pump to other accessories or water features.
  8. Ensure that all connections are secure and leak-free.
  9. Turn on the power supply to activate the pump.
  10. Regularly check and clean the pump to maintain optimal performance.
  11. Refer to the user manual for any troubleshooting or maintenance instructions.

MODELS

Instructions for use

for Ubbink pond pumps Xtra 350 LV, 1000 LV, and 1600 LV

Ubbink XTRA LV pond pumps are high-quality, reliable products that deploy tried-and-tested technologies. The pumps feature synchronous technology and are designed for use in garden ponds, fountain basins and in combination with items such as fountain jets and gargoyle spouts.

Safety regulations

  • The power supply must correspond to the product specifi cations. In case of doubt, ask your local utility about the connection rules. Do not connect the pump or the power cable if they do not conform to the stated rules!

  • For reasons of European safety standards, the pump must always be connected to a shockproof socket. The power circuit must contain a residual current circuit breaker
    (r.c.c.b./30mA). Your local electrical specialist can provide you with further information.

  • The pump is not suitable for use in swimming pools, swimming ponds or other bodies of water in which people could be present. It may therefore not be deployed for such a purpose.

  • Never use the cable to carry the pump or the transformer, and never pull the pump out of the pond using the cable.

  • Never remove the plug from the transformer by cutting it off the connecting cable and never shorten the connecting cable for the pump or transformer. If you do so, your guarantee claim will be invalidated!

  • Under no circumstances may the transformer be used underwater. It must be installed in a stable position at least 2 m away from the edge of the pond where it is safe from flooding, and in such a way that it is not subject to direct sunlight.

  • Make sure that the plug and socket are dry before use.

  • Make sure that the power is switched off before starting any maintenance work on the pond or before cleaning the pump.

  • This pump has been designed to pump water at a temperature of at least 4°C up to a maximum 35°C.

  • Do not allow the pump to run dry. This can cause irreparable damage.

  • This device is not suitable for use by people (including children) with reduced physical, sensory or mental capabilities or who lack experience and/or knowledge, unless they are supervised by a person responsible for their safety or have been instructed in how to use the device. Children must be supervised to ensure that they do not play with the device.

  • The power cable for the pump and transformer cannot be replaced. If the connection line to one of the devices is damaged, this must be taken out of operation and disposed of in order to prevent dangers.

General warnings

  • Some packaging parts can pose a hazard (e.g. plastic bags), these must therefore be kept out of the reach of children and domestic pets.

Use

  • The pumps are suitable for use in ponds, fountains and in combination with fi lter systems.
  • The volume of water conveyed by the pump can be regulated with the through-fl ow controller supplied.

Getting started

  • Please read the instructions for use carefully.
  • Never let the pump run dry, i.e. operation without water running through it.
  • Install the pump at least 20 cm to a maximum 100 cm below the surface of the water on a stable base which is free form mud, slime and other soiling.
  • Depending on the particular use, screw the through-fl ow controller with pipe extension and selected fountain jet or any hose sleeve required onto the pressure nozzle located at the top.

Cleaning and maintenance

  • The pump requires neither lubrication nor any special maintenance work. Simply check from time to time that the inlet slits on the housing are free of soiling and remove such with clean water.

In case of heavier soiling, it is recommendable to dismantle the pump:

  • a) Take the cap off the fi lter housing
  • b) Subsequently lift the pump housing away from the motor section (bayonet lock)
  • c) Undo and carefully remove the rotor and the ceramic shaft, which can then be cleaned
  • d ) After cleaning, reassemble the pump in the reverse sequence

Cleaning/exchanging the rotor

  • Proceed as described under (a) to (c).
  • Please use a soft cloth to clean the rotor. Never use a (chemical) cleaning agent!
  • Avoid damaging the ceramic shaft
  • If necessary, exchange the complete rotor incl. the ceramic shaft (complete replacement part)
  • How often such cleaning is necessary depends on the particular conditions of use. In Winter, make sure that the pump does not become frozen in. You should therefore disassemble the pump and transformer in good time, clean them and keep them in a place safe from frost. The pump (not the transformer) is best kept over Winter in a bucket of water in a frost-free place.

Guarantee

  • We guarantee this product for 2 years against proven material and manufacturing faults from the date of purchase. The original purchase receipt must be presented as proof of purchase in case of guarantee claims. The guarantee does not extend to complaints caused by assembly or operating errors, a lack of care, the effects of frost, improper repair attempts, the use of force, outside culpability, overloads, mechanical damage, or the effects of foreign bodies. The guarantee likewise excludes all complaints concerning parts damage and/or problems caused by wear and tear.

Correct disposal of this product

  • In the EU, this symbol shows that this product may not be disposed of with domestic refuse. Old devices contain valuable materials that can be recycled. They should therefore be taken to your local collection point to be recovered and to avoid pollution of the environment or harm to human health through uncontrolled dumping of rubbish. If there are no suitable disposal systems available near you, please return the old device to the place you purchased it so it can be taken for recycling from there.

Conformity Declaration

The undersigned company UBBINK GARDEN BV declares in own responsibility that all pumps of the series Xtra LV conform to the requirements of the European Directive 2006/95 (Low voltage directive). The following harmonized standards have been applied:

Xtra 350 LV, 1000 LV
EN 60335-1:2007-02; EN 60335-1:2002+A11+A1+A12+Corr.+A2:2006 ; EN 60335-1/A13 :2009-05 ; EN 60335-1/A13 :2008 EN 60335-2-41:2004-12; EN 60335-2-41:2003+A1:2004; EN 50366:2006-11; EN 50366:2003+A1:2006