ubbink Xtra Pond Pump Instruction Manual
- June 12, 2024
- ubbink
Table of Contents
- ubbink Xtra Pond Pump
- Product Information
- Instructions for use for Ubbink pond pumps XTRA 400 / 600 / 900 / 1600 /
- Product Usage Instructions
- Getting started
- Cleaning and maintenance
- Cleaning/exchanging the rotor
- Winter storage
- Guarantee
- Conformity Declaration
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
ubbink Xtra Pond Pump
Product Information
The Ubbink XTRA pond pumps are high-quality and reliable products designed for
use in garden ponds, fountain basins, and in combination with items such as
fountain jets and gargoyle spouts.
They feature synchronous technology and come in different models with
varying specifications:
- Xtra 400: 230 VAC / 50 Hz, 10 m cord length, 5 W power, 380 l/h flow rate, 0.70 m maximum pumping height
- Xtra 600: 230 VAC / 50 Hz, 10 m cord length, 16 W power, 600l/h flow rate, 1.10 m maximum pumping height
- Xtra 900: 230 VAC / 50 Hz, 10 m cord length, 18 W power, 900 l/h flow rate, 1.80 m maximum pumping height
- Xtra 1600: 230 VAC / 50 Hz, 10 m cord length, 33 W power, 1600 l/h flow rate, 2.00 m maximum pumping height
- Xtra 2300: 230 VAC / 50 Hz, 10 m cord length, 35 W power, 2300 l/h flow rate, 2.20 m maximum pumping height
- Xtra 3900: 230 VAC / 50 Hz, 10 m cord length, 110 W power, 3900 l/h flow rate, 4.20 m maximum pumping height
Instructions for use for Ubbink pond pumps XTRA 400 / 600 / 900 / 1600 /
2300 / 3900
Ubbink XTRA pond pumps are high-quality, reliable products which deploy tried- and-tested technologies. The pumps feature synchronous technology and are designed for use in garden ponds, fountain basins and in combination with items such as fountain jets and gargoyle spouts.
Product Usage Instructions
Safety regulations:
- Keep packaging parts that can pose a hazard (e.g. plastic bags) out of the reach of children and pets.
- The power supply must correspond to the product specifi cations. In case of doubt, ask your local utility about the connection rules. Do not connect the pump or the power cable if they do not conform to the stated rules!
- For reasons of European safety standards, the pump must always be connected to a shockproof socket. The power circuit must contain a residual current circuit breaker (r.c.c.b./30mA). Your local electrical specialist can provide you with further information.
- The pump is not suitable for use in swimming pools, swimming ponds or other bodies of water in which people could be present. It may therefore not be deployed for such a purpose.
- Never use the cable to carry the pump, and never pull the pump out of the pond using the cable.
- Never remove the plug by cutting it off the connecting cable and never shorten the connecting cable. If you do so, your guarantee claim will be invalidated!
- Make sure that the plug and socket are dry before use.
- Make sure that the power is switched off before starting any maintenance work on the pond or before cleaning the pump.
- This pump has been designed to pump water at a temperature of at least 4°C up to a maximum 35°C.
- Do not allow the pump to run dry. This can cause irreparable damage.
- This device is not suitable for use by people (including children) with reduced physical, sensory or mental capabilities or who lack experience and/or knowledge, unless they are supervised by a person responsible for their safety or have been instructed in how to use the device. Children must be supervised to ensure that they do not play with the device.
- The power cable cannot be replaced. If the connection line is damaged, the pump must be taken out of operation and disposed of in order to prevent dangers.
General warnings
Some packaging parts can pose a hazard (e.g. plastic bags), these must
therefore be kept out of the reach of children, domestic pets, etc..
Use:
- Place the pump in the desired location, ensuring it is fully submerged in water.
- The pumps are suitable for use in ponds, fountains and in combination with fi lter systems.
- The volume of water conveyed by the pump can be regulated with the through-fl ow controller supplied.
Getting started
- Please read the instructions for use carefully.
- Never let the pump run dry, i.e. operation without water running through it.
- Install the pump at least 20 cm to a maximum 100 cm below the surface of the water on a stable base which is free form mud, slime and other soiling.
- Depending on the particular use, screw the through-fl ow controller with pipe extension and selected fountain jet or any hose sleeve required onto the pressure nozzle located at the top.
Cleaning and maintenance
The pump requires neither lubrication nor any special maintenance work. Simply
check from time to time that the inlet slits on the housing are free of
soiling and remove such with clean water.
In case of heavier soiling, it is recommendable to dismantle the pump:
- Regularly check that the inlet slits on the housing are free of soiling and remove any dirt with clean water.
- In case of heavier soiling, follow these steps to dismantle and clean the pump:
- Take off the cap of the filter housing.
- Lift the pump housing away from the motor section using the bayonet lock.
- Undo and carefully remove the rotor and ceramic shaft for cleaning.
- After cleaning, reassemble the pump in reverse sequence.
- Clean the rotor using a soft cloth. Avoid using any chemical cleaning agents.
- If necessary, exchange the complete rotor including the ceramic shaft with a replacement part.
Cleaning/exchanging the rotor
Proceed as described under (a) to (c). Please use a soft cloth to clean the rotor. Never use a (chemical) cleaning agent! Avoid damaging the ceramic shaft If necessary, exchange the complete rotor incl. the ceramic shaft (complete replacement part) How often such cleaning is necessary depends on the particular conditions of use. In Winter, make sure that the pump does not become frozen in. You should therefore remove the pump from the pond in good time. It is best kept over Winter in a bucket of water in a frost-free place.
Winter storage
- In winter, make sure the pump does not become frozen. Remove the pump from the pond and store it in a bucket of water in a frost-free place.
Guarantee
We guarantee this product for 2 years against proven material and manufacturing faults from the date of purchase. The original purchase receipt must be presented as proof of purchase in case of guarantee claims. The guarantee does not extend to complaints caused by assembly or operating errors, a lack of care, the eff ects of frost, improper repair attempts, the use of force, outside culpability, overloads, mechanical damage or the eff ects of foreign bodies. The guarantee likewise excludes all complaints concerning parts damage and/or problems caused by wear and tear.
Correct disposal of this product
In the EU, this symbol shows that this product may not be disposed of with the
domestic refuse. Old devices contain valuable materials that can be recycled.
They should therefore be taken to your local collection point to be recovered
and to avoid pollution of the environment or harm to human health through
uncontrolled dumping of rubbish. If there are no suitable disposal systems
available near you, please return the old device to the place you purchased it
so it can be taken for recycling from there.
Conformity Declaration
The undersigned company UBBINK GARDEN BV declares in own responsibility that all pumps of the series Xtra conform to the requirements of the European Directive 2006/95 (Low voltage directive).
The following harmonised standards have been applied:
- EN 60335-1:2007-02;
- EN 60335-1:2002+A11+A1+A12+Corr.+A2:2006 ;
- EN 60335-2-41:2004-12;
- EN 60335-2-41:2003+A1:2004 ;
- EN 50366:2006-11;
- EN 50366:2003+A1:2006