ubbink Elimax 1000 Pond Pumps Instruction Manual
- June 12, 2024
- ubbink
Table of Contents
ubbink Elimax 1000 Pond Pumps
Product Information
- Product Name: Elimax Pond Pumps
- Power Supply: 230 VAC / 50 Hz
- Available Models: Elimax 500, Elimax 1000, Elimax 4000, Elimax 1500, Elimax 6000, Elimax 2000, Elimax 2500, Elimax 9000
- Maximum Pumping Height: Ranges from 1.25 m to 5.20 m depending on the model
- Power Consumption: Ranges from 11 W to 215 W depending on the model
- Maximum Flow Rate: Ranges from 700 l/h to 8,800 l/h depending on the model
Product Usage Instructions:
To use the Elimax Pond Pump, follow these steps:
- Ensure that the power supply is compatible with 230 VAC / 50 Hz.
- Select the appropriate model based on your pond size and desired flow rate.
- Place the pump in a suitable location, such as a garden pond or fountain basin.
- If using in combination with fountain jets or gargoyles, connect the necessary accessories (T-piece, Lava, Foam Jet, Telescope tube, Hoseconnector) according to the specifications mentioned in the user manual.
- Connect the pump to the power supply.
- Adjust the pump settings, if applicable, to control the flow rate and water height.
- Regularly clean and maintain the pump by following the instructions in the user manual. This may involve removing the pump housing, cleaning the rotor and ceramic shaft, and performing any necessary maintenance tasks.
Note:
Dispose of any waste electrical products properly by recycling them at a
designated collection point. Contact your local authority or retailer for more
information on recycling options.
Specification
| Elimax 500| Elimax 1000| Elimax 1500|
Elimax 2000| Elimax 2500
---|---|---|---|---|---
| 230 VAC / 50 Hz| 230 VAC / 50 Hz| 230 VAC / 50 Hz| 230 VAC / 50 Hz| 230 VAC
/ 50 Hz
__| 10 m| 10 m| 10 m| 10 m| 10 m
__| 11 W| 15 W| 20 W| 35 W| 46 W
__| 700 l/h| 1.200 l/h| 1.500 l/h| 2.550 l/h| 2.700 l/h
__| 1.25 m| 1.45 m| 1.85 m| 2.20 m| 2.60 m
__| ½“| ½“| ½“| ½“| ½“
__| T-piece 1/2”| T-piece 1/2”| T-piece 1/2”| T-piece 1/2”| T-piece
1/2”
Vulcano small Lava mini| Vulcano small Lava small| Vulcano medium Lava medium
Foam Jet midi| Vulcano medium Lava medium Foam Jet midi| Vulcano medium Lava
medium Foam Jet midi
Telescope tube 1/2”| Telescope tube 1/2”| Telescope tube 1/2”| Telescope tube
1/2”| Telescope tube 1/2”
Hose connector 1/2” x 9 mm 1/2” x 13 mm 1/2” x 19 mm| Hose connector 1/2” x 9
mm 1/2” x 13 mm 1/2” x 19 mm| Hose connector 1/2” x 9 mm 1/2” x 13 mm 1/2” x
19 mm| Hose connector 1/2” x 9 mm 1/2” x 13 mm 1/2” x 19 mm| Hose connector
1/2” x 9 mm 1/2” x 13 mm 1/2” x 19 mm
| Elimax 4000| Elimax 6000| Elimax 9000
---|---|---|---
| 230 VAC / 50 Hz| 230 VAC / 50 Hz| 230 VAC / 50 Hz
__| 10 m| 10 m| 10 m
__| 75 W| 125 W| 215 W
__| 4.100 l/h| 6.100 l/h| 8.800 l/h
__| 2.90 m| 3.90 m| 5,20 m
__| 1”| 1”| 1”
| T-piece 1”| T-piece 1”| T-piece 1”
Vulcano large Lava large Foam Jet large| Vulcano large Lava large Foam Jet
large| Vulcano large Lava large Foam Jet large
Telescope tube 1”| Telescope tube 1”| Telescope tube 1”
Hose connector 1” x 13 mm
1” x 19 mm
1” x 25 mm
| Hose connector 1” x 13 mm
1” x 19 mm
1” x 25 mm
| Hose connector 1” x 13 mm
1” x 19 mm
1” x 25 mm
The Ubbink Elimax pond pumps are high-quality products based on the latest technology. The pumps use synchronous technology and are suitable for use in garden ponds, and fountain basins as well in combination with e.g. fountain jets and gargoyles.
Safety regulations
- The power supply must conform to the product specifications. If in doubt, ask your local utility about connection regulations. Do not connect the pump or the network cable if they do not conform to the specified regulations!
- For reasons of European safety standards, the pump must always be connected to a socket with earth contact. The electric circuit must include an earth leakage protection switch (FI-Protection switch /30mA). Further information is available from your local electro-specialist.
- The pump is not suitable for use in swimming pools, swimming ponds, or other environments, in which persons get into contact with the water and, therefore, must not be used for these purposes.
- Never use the cable for carrying the pump and never pull the pump out of the pond by the cable.
- Never remove the plug by cutting it from the connecting cable and never shorten the connecting cable. In case of not complying with this, the guarantee becomes invalid!
- Ensure that plug and socket are dry before start-up.
- Always switch off the electricity before maintenance work at the pond or for cleaning the pump.
- This pump is suitable for pumping water at a temperature of a minimum of 4°C to a maximum of 35°C.
- The pump must not run dry. This can lead to irreparable damages.
- This device is not designed to be operated by persons (Including children) with restricted physical, sensory, or mental capabilities or due to experience and/or lack of knowledge unless they are supervised by a person responsible for their safety or have been instructed about how the device must be operated. Children should be supervised to ensure that they do not play with the device.
- Replacement of the net cable is not possible. In order to avoid hazards, the pump must be taken out of operation and disposed of in case the connecting cable gets damaged.
General Warning
Parts of the packaging may be dangerous (e.g. plastic bags). Therefore, these
must be stored away from children, pets, etc.
Application
- All pumps are equipped with an economical, extremely powerful, and very reliable motor.
- By using the supplied l ow controller (T-piece) you can use the pump for several applications at the same time, e.g. fountain jet and gargoyle.
- The supplied ball pivot allows you to align the telescope tube with the fountain jet vertically.
Start-up
- Please, read the operating instruction thoroughly.
- Never let the pump operate dry, i.e. without water lowing through.
- Install the pump at least 20 cm and a maximum of 100 cm below water level on a stable base free from silt or other pollution.
- Screw the l ow controller (T-piece) with the telescope tube and selected the fountain jet or the required hose nozzle to the discharge nozzle at the top.
Maintenance and cleaning
The pump needs neither lubrication nor special maintenance work. Only, from time to time check the inlet slits at the housing for dirt and, if needed, remove/clean these with clean water
We recommend disassembling the pump (See drawing) in case of bad soiling:
- Remove the low controller, hose nozzle, or telescope tube with jet.
- Unscrew the nut from the discharge nozzle (1.)
- Loosen the top part of the pump housing from the bottom part (clip-on lock). Now you can clean the top/bottom part as well as the outer pump housing (2.) + (3.)
- After this, remove the pump housing from the motor part (With bayonet catch) and carefully loosen the rotor and the ceramic shaft, which can then also be cleaned (4.)
- After cleaning, reassemble the pump in reverse order.
- The frequency, with which this cleaning is necessary, depends on the respective use situation as well as the soiling intensity of your pond.
- During winter, ensure that the pump does not freeze. It is best to keep it during the winter in a pail with water in a frost-free location.
Cleaning/replacing the rotor
- Proceed as described from (a) to (e).
- Please use a soft cloth for cleaning the rotor. Never use a (chemical) cleaning agent!
- Avoid damaging the ceramic shaft
- If necessary, replace the whole rotor including the ceramic shaft (Complete spare part)
Guarantee
We guarantee this product for i ve years against provable material and manufacturing faults; starting from the date of purchase. The original purchasing proof must be presented for claims under this guarantee. The guarantee does not cover complaints caused by assembly and/or operating faults, insu ffi client care, frost damage, improper repair attempts, use of force, third-party faults, overload, mechanical damages, or impact of foreign bodies. Also excluded from the guarantee are all complaints regarding damages to parts and/or problems, which are due to wear.
Environmental Protection
Waste electrical products should not be disposed of with household waste.
Please recycle where facilities exist. Check with your Local Authority or