VIZULO Eagle 2 heads LED flood light Premium version
Mounting instruction VIZULO Eagle 2 Heads LED Flood
Light

Dimensions

VIZULO Eagle 2 Heads LED Flood Light - Dimensions

Netto Weight

Luminaire Weight (Kg) 288
LED count 24.3
Driver Box Weight (Kg) 7.4

Maximal wind load with driver box depending to the angle relative to the ground

15° 30° 4S° 60° 7S° 90°
SCx, m2 0.14 0.21 0.27 0.32 0.36 0.38

Acceptable luminaire mounting angle relative to the ground.

VIZULO Eagle 2 Heads LED Flood Light - Acceptable

Unacceptable luminaire mounting – light is not supposed to be directed at luminaire and it parts.

WARNING!

  • Do not touch LED modules!
  • Do not put any tools or other items on LED modules!
  • In case any LED is physically damaged (example shown below) the warranty is void.

VIZULO Eagle 2 Heads LED Flood Light - Acceptable 3

VIZULO Eagle 2VIZULO Eagle 2 Heads LED Flood Light - Acceptable 3Heads LED
Flood Light - Acceptable 4

VIZULO Eagle 2 Heads LED Flood Light - Acceptable 5

VIZULO Eagle 2 Heads LED Flood Light -Energy 22

VIZULO Eagle 2 Heads LED Flood Light -Energy 11

VIZULO Eagle 2 Heads LED Flood Light - Acceptable 6

LED Power CCT Risk group Remarks
Olson Square 220-1040W 5 5700 K RG1 after TBC m* Label required
Luxton 5050 220-1040W 5. 5700 K RG1 after TBC m* Label required
Doris 58 220-1040W 5 5700 K RG1 after TBC m* Label required

VIZULO Eagle 2 Heads LED Flood Light - Icon 1 *The luminaire should be positioned so that prolonged staring into the luminaire is not expected from a distance closer than shown in the table above.

MCB/Inrush current table

LED Driver T – 230 Vac

Standard/High density| In-rush current
(peak/duration)| 6A| 10A| 16A| 20A| 25A| MCB type
Eagle 2 Heads Premium| 4A (2000115)| 0| 1| 2| 3| 4| B,C,D

MCB/Inrush current table

LED Driver D – 230 Vac

Standard/High density| In-rush current
(peak/duration)| 10A| 16A| 20A| 25A| 32A| MCB type
Eagle 2 Heads Premium| 25A (8000µs)| 1| 2| 2| 3| 4| B,C
LED Driver E- 230 Vac

Standard/High density| In-rush current
(peak/duration)| 10A| 16A| 20A| 25A| MCB type
Eagle 2 Heads Premium| 40A (25001.1s)| 1| 2| 3| 3| B,C,D

Energy efficiency class of contained light source(s)

Standard

| CRI
---|---
70| 80| 90
CCT| 1800| F| |
2200| E| |
2500| E| |
2700| D| E| F
3000| D| E| F
4000| C| D| E
5000| C| D| E
5700| C| D| E
6500| C| | E

Eco

| CRI
---|---
70| 80| 90
CCT| 2200| E| F|
2700| E| E| F
3000| E| E| F
4000| D| E| F
5000| D| E| F
5700| D| E| F
6500| D| |

Terms of use and maintenance
Before luminaire is turned on, it should be mounted according with this mounting instruction or any other applicable regulations.

Mounting instructions

Mounting of luminaire must be performed by a qualified person according with following instructions:

  • The warranty of luminaire does not apply, if the mounting of luminaire has been performed in precipitation (rain, snow, hail).
  • The warranty of luminaire does not apply, if a control system unauthorized by VIZULO or an inapplicable LED driver has been used to drive the luminaire.
  • The warranty of luminaire does not apply, if it has been used in an unsuitable ambient temperature or has been supplied by voltage outside of the specified range.
  • The warranty of luminaire does not apply, if the LED driver program has been changed in any way.
  • The warranty of the luminaire does not apply, if the logged history data of the LED driver has been deleted without the permission of VIZULO.
  • The warranty of luminaire does not apply, if it has been mounted in unspecified angles or upside down (luminaire glass directed up), or it has been completely submerged under water.

Safety instructions

Any actions with the luminaire must be performed by a qualified person, who is certified according with national regulations and requirements.
To prevent any accidents person installing the luminaire must follow national safety requirements and following instructions:

  • The label containing technical parameters of the luminaire has to be studied before the work on it has begun.
  • Any luminaire build or design changes are prohibited.
  • The luminaire must be used in good technical condition and according with this instruction.
  • Only VIZULO authorized spare parts and accessories can be used to repair the luminaire.
  • The repair of luminaire has to be performed by a qualified and certified person.

08-02-2022
SIA VIZULO
Laucu Lejas, Iecava, Latvia, LV-3913
www.vizulo.com