Rinnai RE160EP Tankless Water Heaters Instruction Manual
- June 12, 2024
- Rinnai
Table of Contents
Rinnai RE160EP Tankless Water Heaters
Residential Use
Use your location on the map to correlate with legend for average ground water temperature in the U.S.
For Hawaii and Puerto Rico, use ground water temperature of 75° F
For Canada and Alaska, use ground water temperature range 35-42° F.
Average inlet water temperature.
These are general temperature zones, actual inlet temperature may be affected
by local variations and seasonal changes.
Non-Condensing
Model: RE160i/e
BTU: 160,000
| Ground Water Temperature| Max Flow Rate (GPM)|
Simultaneous Shower Use
---|---|---|---
|
35 ° F
|
3.1
|
37 ° F
|
3.2
|
42 ° F
|
3.4
|
47 ° F
|
3.6
|
52 ° F
|
3.9
|
57 ° F
|
4.2
|
62 ° F
|
4.5
|
67 ° F
|
5.0
|
72 ° F
|
5.5
|
77 ° F
|
6.1
|
Note: Simultaneous shower use was rounded to the nearest whole number based on the following data: Tankless set temperature of 120°F, mixed shower temperature of 105°F, ground water temperature as shown in the chart, and shower head flow rate of 2 gpm.
- Customer has the option of using the following appliances instead of a shower: Residential grade clothes washing machine, hand sink or dishwasher.
- Shower heads will be as above. If custom shower fixtures i.e. body sprays, high flow rate rain heads are used, please contact Rinnai.
Copyright 2022 Rinnai America Corporation. Rinnai is a registered trademark of
Rinnai Corporation used under license by Rinnai America Corporation.
Rinnai America Corporation continually updates materials, and as such, content
is subject to change without notice.
Read User Manual Online (PDF format)