ClimaRad S-Fan Plus Instruction Manual
- June 12, 2024
- climaRAD
Table of Contents
ClimaRad S-Fan Plus
Product Information:
4-position switch S-Fan+
The 4-position switch S-Fan+ is a wireless RF switch that allows manual
operation of the ClimaRad S-Fan+. By default, the ClimaRad S-Fan+ operates in
auto mode, where it functions fully automatically. However, with the
4-position switch, you can
manually override the automatic control.
Product Usage Instructions:
4-position switch S-Fan+
To use the 4-position switch S-Fan+ with the ClimaRad S-Fan+, follow these steps:
- Make sure the 4-position switch is within the range of the ClimaRad S-Fan+.
- Press the button labeled “AUTO” on the 4-position switch.
- The current operating mode will be displayed on the switch using four positions: I, II, III, and O.
- To manually override the automatic control and set the fan speed to position I, press the button once.
- To set the fan speed to position II, press the button once again.
- To set the fan speed to position III, press the button twice.
- To turn off the fan completely (position O), press the button three times.
- The number of presses required for each setting is indicated in the table above.
Note that the duration of each fan speed setting is not mentioned in the provided text extract. Please refer to the complete user manual for more detailed information on the duration of each setting.
Description and application
- Using the wireless RF 4-position switch, your ClimaRad S-Fan+ can be operated manually.
- By default, the ClimaRad S-Fan+ operates fully automatically (auto mode).
- However, the automatic control can be manually overridden by the I, II, III, O (low, medium, high and pause) mode.
- When the comfort button ( ) is on, the outside air is preheated to 12°C.
- After a period of 4 hours, the ClimaRad S-Fan+ switches back to automatic control.
- When the heating function ( ) is switched on, the room is additionally heated. After a period of 2 hours, the ClimaRad S-Fan+ switches back to automatic control.
Setting options and operation of 4-position switch ClimaRad S-Fan+
If a button is pressed longer than indicated, no action is performed and the switch switches to standby to conserve battery power.
Button | number of press | duration | action |
---|---|---|---|
AUTO | 1 | <1s | automatic |
1 | <1s | low setting | |
2 | <1s | middle position | |
3 | <1s | high setting | |
4 | <1s | pause | |
no function | |||
no function | |||
+ | 1 | 3-6 s | connect modus |
After using the switch correctly, the LED results are displayed, as described in the table opposite.
LED colour | flashing | description |
---|---|---|
green | 1x | mode changed/normal operation |
green | 2x | link with S-Fan successful |
orange | 1x | low battery/start-up |
orange | 2x | S-Fan displays message ‘filter dirty’ |
red | 1x of 2x | Contact corporation/landlord |
ClimaRad B.V. – Lübeckstraat 25 – 7575 EE – Oldenzaal – NL – info@climarad.com – www.climarad.nl/en – tel. +31 541 358130