Neomounts PLASMA-M2550T Flat Screen Stand Instruction Manual

June 12, 2024
Neomounts

Neomounts-LOGO

Neomounts PLASMA-M2550T Flat Screen Stand

Neomounts-PLASMA-M2550T-Flat-Screen-Stand-PRODUCT

Product Information

The product is the Plasma-M2550TBLACK/SILVER, a height-adjustable mount for displays. It is compatible with displays that have a VESA mounting pattern of 400×200 to 800×600 mm and weigh between 0 and 150 kg. The mount has a motorized column for easy height adjustment and comes with various parts including vertical brackets, a tiltable frame, a trolley, a control unit, and cables.

Product Usage Instructions

  1. Step 1: Attach the base (D) to the vertical support (C).
  2. Step 3: Attach the vertical brackets (B) to the display and secure them to the mount using the provided tool.
  3. Step 4: Connect the 5-pole plug of the control unit (J) to the mount and connect the power cable (I) with the mount and socket.
  4. Step 5: Press and hold the remote control buttons (J) to adjust the height of the mount.

Important Hazard & Safety Notes:

  • The socket connections of the unit and the wall socket must be easily accessible.
  • The device is not dripping or splashing water protected. Do not place objects filled with liquids on or spray the device.
  • For moveable and free-standing units, only operate on a plane and stable floors. Lock the brakes of front wheels when operating.
  • For wall-mounted units, use appropriate wall-mounting material and have it done by experienced personnel only.
  • Follow the instructions for disposal and do not dispose to consumer waste.

Dimension

Neomounts-PLASMA-M2550T-Flat-Screen-Stand-
FIG-1

Floor stand

PARTS

STEP 1

Attach the base (D) to the vertical support (C)

STEP 2
Install the frame (A) to the column (C)

STEP 3
Attach the brackets (B) to the display, attach them to the mount and secure them

STEP 4
Connect the 5-pole plug of the control unit (J) to the mount and connect the power cable (I) with the mount and socket

STEP 5
Press and hold the remote control buttons (J) to adjust the height of the mount

IMPORTANT HAZARD & SAFETY NOTES

Please carefully read the below hazard and safety notes before using the height adjustment unit. This contributes to make the unit work failure-free and avoids accidents.

Electrical safety
Connect unit to a free accessible 110-230 V / 50 Hz grounded power outlet only. Make sure, the unit can be immediately separated from the power outlet.
Only use unit in dry rooms, protect unit from water and other liquids. Only wipe unit with dry cloth.
Do not open lift unit. RISK OF ELECTRIC SHOCK. There are no serviceable parts inside.
In case of disfunction unplug unit from power outlet and call an authorised technical service person.
Do not overrun line cord or damage in any other way.
Replace damaged line cords immediately with new one from same type.
The socket connections of the unit and the wall socket must be easily accessible.
The device is not dripping or splash water protected.
Do not place objects filled with liquids on or spray the device.

General tips for mechanical safety
Do not improperly load unit. Do not mount other than original parts (whiteboard, wings, interactive board, interactive monitor, projector) in conjunction with original mounting parts. Do not hang on unit.
VERY HEAVY UNIT.
Severe risk of injury when unit falls over due to improper usage. Only use original mounting parts provided with the system. Max load of lift unit is 150 kg/ 330 lbs. Do not exceed.
Assure installation of unit by authorized service person only.
Before moving the unit up or down ashure at least a safety distance of 20 cm/ 7.9 from any part of the unit to any other fitment in order to avoid shear traps or squeezing points.
In case of an accident please release the operating panel. Movement of unit will stop immediately.
Special tips for moveable und free-standing units Only operate unit on plane and stable floors. Move unit on plane floors only.
Risk of tilting when overrunning floorunevennesses, door sills and similar.
VERY HEAVY UNIT.
Severe risk of injury when unit falls over. Lock brakes of front wheels when operating unit.
Special tips for wall-mounted units
Use appropriate wall mounting material only. Choose douwels and screws according to the wall type and material. Using improper mounting material may result in tilting of the unit and severe risk of injury.
Wall mounting must be done by experienced personnel only.
Instructions for disposal Do not dispose to consumer waste.

CAUTION

  1. To ensure safety, please read this manual carefully before installation and follow the instructions Store this manual in a secure place for future reference
  2. The manufacturer shall not be legally responsible for any equipment damage or personal injury caused by incorrect installation or operation other than that covered in this manual.
  3. The mount is designed for easy installation and removal. I he manutacturer shall not be liable for damage to equipment or personal injuries arising out of human factors or acts of nature, such as earthquakes or typhoon.
  4. its recommended that the mount he installed hv analyzed personnel on
  5. At least two persons are needed to install or remove the product to avoid the hazard of falling objects.
  6. Please care on inspecting the area where the mounts to be installed
    • Avoid places mac are piece o nign temperatures, number or contact with water
    • Do not install the product near air conditioning vents or areas with excess ascend rules
    • Only install on vertical walls and avoid slanted surfaces.
    • Do not install in places subjected to anv shock or vibration
    • places subjected to direct exposure to bright light. as it mav cause eve fatigue when viewing the Display panel
  7. Maintain sufficient space around the display to ensure adequate ventilation.
  8. To ensure safe installation, first check the structure of the wall, ceiling or floor and select a secure mounting location.
  9. The wall, ceiling or floor should be strong enough to sustain a weight of at least four times of the display and mount combined. The mounting location must be able to withstand carhquake or other strong shock.
  10. Do not modify any accessories or use broken parts. Contact your dealer with any questions.
  11. Tighten all screws (do not exert excessive force to avoid breaking the screw or damaging its thread).
  12. Drill holes and bolts will be left in the wall, ceiling or floor once the display and bracket are removed. Stains may occur after extended use.
  13. Since the manufacturer has no way to control the wall, ceiling or floor type and installation of the mount, the warranty of the product shall only cover the body of the mount. The warranty period of the product is 5 years.
  14. Please consult the English language manual for any dispute on conditions.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals