tuya RS-485 WIFI Intelligent Control Switch Instruction Manual
- June 4, 2024
- Tuya
Table of Contents
- 1 Scope and characteristics of the application
- Product function
- Normal working conditions
- Type and meaning
- Technical parameter
- Installation
- Operation Trial and panel instructions: Panel see fig.4
- Product characteristics:
- Communication instruction
- Install doodler “tuya” APP.
- Distribution Network
- Points to note
- The signal indicator is not on: Please check.
- Product function
- Place of use
- The product panel is illustrated in figures 7-8
- FCC Statement
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
WIFI Intelligent control switch
metering + RS485
metering +WIFI
metering + RS485+WIFI
Instruction Manual
1 Scope and characteristics of the application
Intelligent circuit breaker for AC50Hz, Rated operating voltage 230V, Rated working current 63A and the following user or load, Good-looking, Good and reliable performance, split/merge fast Modular rail type installation. Mainly used for family, shopping malls, office buildings, hotels, schools, hospitals, villas, and so on.
Product function
2.1 Automatic closing, For Products in the normal line, power can be
automatically closed, and can also be set when the switch is not closed.
2.2 Wireless Control: Mobile APP Remote Control On/off
2.3 Real-time feedback: Real-time feedback of product split/close status.
2.4 Timing: Timing on/off.
2.5 Share Control: Can share more people’s controls.
2.6 Residual current protection:
When the leakage current is greater than the set value or personal electric
shock (with leakage protection), the protector automatically disconnects
within 0.1 s.
2.7 With metering function: Can display voltage, current, power, and
electricity.
Normal working conditions
3.1 Ambient air temperature
a. The upper limit shall not exceed 40℃
b. The lower limit shall not be lower than-5 °C
c. The average value within 24h does not exceed 35℃
d. Limit service temperature -25℃ ~ 70℃
3.2 Altitude
The elevation of the installation site shall not exceed 2,000 meters.
3.3 Atmospheric condition
a. When the ambient air temperature is + 40 °c, the relative humidity of
the air does not exceed 50%, Higher relative humidity can be achieved at lower
temperatures.
b. When the monthly mean minimum temperature of the wettest month is 25
°C, the monthly mean phase humidity is 90%.
c. Condensation on the surface of the product due to a change in
temperature has been taken into account.
3.4 Pollution level
The pollution level used in the circuit breaker is level 2.
3.5 Type of installation
Class II, Class III installation
Type and meaning
Note: 1P without leakage protection, 2P can choose with leakage protection and . without leakage protection.
Technical parameter
5.1 Rated operating voltage: AC230V
5.2 Rated current In: 1A-63A
5.3 Life Span: Electrical Life, on and off 100000 times.
5.4 Power consumption of this product:<3W
5.5 Operating voltage range: AC120V-280V
5.6 Maximum rated output current: In63A
5.7 Wiring: Using a clamp wiring terminal, The cross-sectional area of
the connecting cable can reach 16mm2
5.8 Installation: installed on 35*7.5 mm standard guide rail
5.9 RS485 Communication Baud Rate: 9600; address range: 1-247.
Installation
6.1 The outline dimension drawing and the installation dimension drawings
are shown in Fig. 1 and Fig. 2
6.2 Wiring Diagram: See Fig. 3
6.3 Installation method
The circuit breaker shall be mounted vertically on the mounting rail, which
shall be fixed to the plywood or metal plate with M5 screws. And then install
the product.
Fig 2
|
---|---
Operation Trial and panel instructions: Panel see fig.4
7.1 Operating instructions
7.1.1 Click the ” ” button to switch on/off
7.1.2 Long Press “ ” for 10 seconds. Match status.
7.2 Light indication
7.2.1 Red Light always on: Switch on.
7.2.2 Red Light slow flash: switch off.
7.2.3 The signal light flashed quickly: Pairing state
7.2.4 With leakage protection (2P switch) products, click the “ ” button
(the product is in the closing state), and the switch immediately opens, this
button tests the product’s leakage function.
7.2.5 Signal indicator light fig4
The green light is normal: the light is always on for closing and the green
light flashes for opening
Red Light flashing: Fault Opening State, can not close. If wi-fi is available,
the indicator light indicates the signal status. The above is the indication
status of the RS485 lamp.
Product characteristics:
8.1 The mobile phone APP can read/modify parameters remotely and can
open/close remotely.
8.2 RS485 communication, remote opening/closing, setting parameters.
8.3 Under-voltage protection: Can set under-voltage action value, can
also turn off the under-voltage function.
8.4 Loss of voltage protection: When the under-voltage function is turned
on, there is a loss of voltage protection, that is, power cut trip, the
product can not be closed manually at this time.
8.5 Voltage, current, leakage current, and temperature action value can
be set.
8.6 Can Read real-time voltage, current, leakage current, temperature,
and power value, with metering function.
8.7 Manual/automatic setting: Manual or automatic mode can be set.
Communication instruction
9.1 Communication settings and functional instructions are detailed in
the communication protocol.
9.2 Overvoltage/Undervoltage opening or closing can be set by function
instruction.
9.3 Set the auto-closing or manual-closing state by function instruction.
9.4 The real-time voltage can be read through the function command, and
the circuit breaker is on/off.
Note: Sending instructions must be connected to the power supply of the
product and keep the communication status.
Install doodler “tuya” APP.
10.1 Direct scan figure 5 Installation.
10.2 Download”tuya Smart”app. Search” smart life” in App Store for the
IOS version or Google play for the android version.
https://smartapp.tuya.com/tuyasmart
Fig 5
10.3 Apple searches the APP store for a “smart life” APP and installs it.
10.4 As shown in figure 2, the circuit breaker according to the
requirements of the correct wiring and electrification, to circuit breaker
signal indicator light.
Distribution Network
11.1Run “tuya Smart”, Click “+ ” in the upper right corner, and pop up “add
manually”.
11.2 The device was successfully added and then automatically connected to the
network. The connection may take a few minutes. Please be patient. When the
indicator light (green light) is always on, the connection is successful.
11.3 When the indicator is always on and the connection is successful, the
switch can be operated on the mobile phone APP.
11.4 When the network is connected, the circuit breaker can be operated
on/off, sharing, timing, delay, user operation notification, power-on status,
and so on.
11.5 When the load is switched on, the real-time power, current, and voltage
can be displayed, the electricity can be counted and the threshold can be set
to close automatically. user operation notification, power-on status, and so
on.
If the signal indicator light is not bright or slow flash, you need to press
the “blue button” key for about 10 seconds, when the signal indicator light
flashes after release, into the distribution network state.
The indicator lights flash quickly: Direct configuration network.
Indicator light not on or flashing slowly: Long press the “blue button”, fast
flicker after matching network after.
Voice Control: Can connect TMALL elve, XIAODU, and other smart speakers, through voice control of the product on/off.
Points to note
13.1 The products be protected from rainwater during transportation and
storage, and the product shall be stored in a place with air circulation.
13.2 Dust and dirt should be removed regularly during use.
13.3 The basic technical data on the nameplate or sign should be checked
before use.
13.4 The parameter protection characteristic of this product is set by
the manufacturer, and can not be adjusted in use
13.5 Zero wire must be connected correctly.
13.6 Tighten the connection screw before use to avoid bad contact and
damage to the product.
13.7 The setting temperature of this series of circuit breakers is 30 + 5
°C. if several circuit breakers are installed in the same sealed box, the
capacity reduction Coefficient should be 0.8.
The signal indicator is not on: Please check.
14.1 Whether the power cord is connected as required ( The zero
wire/firewire must be correctly connected to the corresponding zero
wire/firewire of the distribution system).
14.2 Is The power supply voltage normal?
Product function
15.1 Overload protection
15.2 Voltage detection
15.3 creepage detection
15.4 Temperature detection
15.5 Current detection
15.6 Mechanical locking device
15.7 Remote Lock. Remote unlock
15.8 With metering function
15.9 With parameter setting
15.10With pre-paid features
15.11 With fault query
Place of use
Mainly used in homes, schools, hospitals, shopping malls, office buildings,
irrigation, farms, pumps, rental housing the villa, and other electrical
equipment remote control.
Note: This product can not be used as the main brake, the front end of
the product is to be installed short-circuit protection circuit breaker.
The product panel is illustrated in figures 7-8
Note:
The intelligent circuit breaker has voltage, current, leakage current, and
temperature action values that can be set. Can Read real-time voltage,
current, leakage current, temperature, and power value, with metering
function. Remote control, remote parameter setting.
1P+N Panel description | 2PPanel description |
---|
Note: The intelligent circuit breaker has voltage, current, leakage current, and temperature action values that can be set. Can Read real-time voltage, current, leakage current, temperature, and power value, with metering function. Remote control, remote parameter setting.
FCC Statement
This device complies with part 15 of the FCC Rules. Operation is subject to
the following two conditions:
Any Changes or modifications not expressly approved by the party responsible
for compliance could void the user’s authority to operate the equipment.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- This device may not cause harmful interference, and
- this device must accept any interference received, including interference that may cause undesired operation.
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.