ALPHA Fan ALLY-5B-56 Ceiling Fan Instruction Manual
- June 12, 2024
- ALPHA FAN
Table of Contents
- ALPHA Fan ALLY-5B-56 Ceiling Fan
- SAFETY PRECAUTION
- PARTS & ACCESSORIES
- INSTALLATION INSTRUCTION
- TRANSMITTER LEARNING PROCESS
- The function of Forward & Reverse
- POWER SUPPLY CONNECTION
- MAINTENANCE
- TECHNICAL SPECIFICATIONS
- CUSTOMER SERVICE CENTRE
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
ALPHA Fan ALLY-5B-56 Ceiling Fan
SAFETY PRECAUTION
Warning
Installation and maintenance work shall only be performed by qualified
persons, familiar with local codes and regulations, and experienced with this
type of appliance. All field wiring must be installed in accordance with the
national wiring regulation. Ensure that the rated voltage of the unit
corresponds to that of the nameplate before commencing wiring work according
to the wiring diagram. The appliance must be permanently connected to the
electricity supply through a double pole switch having a contact separation of
at least 3mm in all poles. The unit must be GROUNDED to prevent possible
hazards due to insulation failure. The earth wire is approximately 60mm longer
than the safety wire. This is to ensure at the event whereby the suspension
system fails, the (L) and (N) wires will break leaving the fan to remain
earthed to prevent electrocution. Tighten the blade firmly using a
screwdriver. Blades that are detached from the unit during operation will
cause serious injuries and property damage. This appliance is not intended for
use by persons (including children) with reduced physical, sensory or mental
capabilities, or lack of experience and knowledge, unless they have been given
supervision or instruction concerning use of the appliance by a person
responsible for their safety. Children should be supervised to ensure that
they do not play with the appliances. Confirm that the power supply has been
switched OFF before installing or servicing the unit. Ensure that the blade is
fully static before doing any maintenance work. STOP using the ceiling fan
when any abnormality or failure occurs. If unusual oscillating movement is
observed, immediately stop using the ceiling fan and contact the manufacturer,
its service agent or suitably qualified persons.
CAUTION
Please take note of the following important points when installing. The fixing
means for attachment to the ceiling such as hooks or other devices shall be
fixed with sufficient strength to withstand 4 times the weight of the ceiling
fan. The mounting of the suspension system shall be performed by the
manufacturer, its service agent or suitably qualified persons. The fan is to
be installed so that the blades are more than 2.5m above the floor. The safety
cord should not be longer than the earthing conductor. Should the failure of
the suspension system occur, the support of the fan must not rely on the
earthing conductor. The earthing terminal in the fan assembly should be such
that should any part of the suspension system fall off, the body of the fan
assembly shall be effectively earthed. Ensure that the unit’s panel is closed
after service or installation. Unsecured panels will cause the unit to operate
noisily. Sharp edges and coil surfaces are potential locations that may cause
injury hazards. Avoid being in contact with these places. Before turning off
the power supply set the remote controller’s ON/OFF switch to the “OFF”
position. If this is not done, the unit’s fans will start turning
automatically when power resumes, posing a hazard to service personnel or the
user. Do not operate any heating apparatus too close to the ceiling fan unit
or use in a room where mineral oil, oil vapor or oil steam exists, this may
cause the plastic part to melt or deform as a result of excessive heat or
chemical reaction. Avoid the ceiling fan unit from exposing to direct
sunlight, this may cause the degradation of plastic material as a result of
excessive heat and UV radiation. Ensure the color of the wires of the outdoor
unit and the terminal markings are same to the indoors respectively. Don’t use
joined and twisted wires for incoming power supply. Do not place any object in
the path of the blades. Avoid raising objects or your arms near the ceiling
fan. The fan suspension system and blade screw tightening shall be examined
yearly. Replacement of parts of the safety suspension system device shall be
performed by the manufacturer, its service agent or suitably qualified
persons. The torque value for screws/bolts for securing the primary suspension
system for the motor is 2Nm.
PARTS & ACCESSORIES
INSTALLATION INSTRUCTION
STEP 1
- Assemble the Canopy and Coupling Cover through the Downrod.
STEP 2
- Fix the Rubber Pulley Assembly to the Downrod with Bolt, Washer, Nut and tighten them firmly then insert the Clevis Pin and Washer.
IMPORTANT : A CLEVIS PIN MUST BE INSERTED TO PREVENT THE NUT FROM LOOSENING.
STEP 3
- a. Remove the Bolt, Washer, Nut, Clevis Pin and Rubber Pulley from downrod.
- b. Place the Rubber Pulley onto the ceiling hook and fix back the Bolt, Washer, Nut and Clevis Pin.
- c. Remove the Safety Wire screw and spring washer from the Downrod.
- d. Tie the Safety Wire across the hook as shown and firmly screw the Safety Wire onto the Downrod.
STEP 4
- a. Connect the Connectors from Fan and Receiver.
- b. Connect the wires from the receiver to House’s Supply Wire.
- c. Connect Earth Wire to House Supply Earth Terminal.
Step 5
- a. Install the Blades on Motor with Blade Screw and Washer. Two pieces Blade Screw and Washer for each Fan Blade.
- b. Install the Decorative Cover by twisting clockwise.
Step 6
Below shows a complete installation diagram
TRANSMITTER LEARNING PROCESS
IMPORTANT : DO NOT CONNECT THIS REMOTE CONTROL CEILING FAN TO THE DIMMER SWITCH OR REGULATOR.
The receiver & transmitter is pre-programmed in factory. If you wish to
control 2 or more fans using 1 transmitter, the below steps are required.
DO NOT PRESS ANY OTHER BUTTON DURING THIS PROCESS
Step 1
- a) Insert the 2 pcs of batteries (provided) into transmitter.
- b) Turn on the power supply (wall switch) to the fan.
- c) Within 30 sec, press and hold the “LEARN” button for 3 sec. Once the receiver has detected the frequency, the transmitter will “Beep Beep” twice. The programming process is completed and the fan is ready to use. If the fan is not responding to the transmitter, repeat Step 1b.
IMPORTANT : DO NOT CONNECT THIS REMOTE CONTROL CEILING FAN TO DIMMER SWITCH OR REGULATOR.
The transmitter & receiver is incorporated with last memory function. This function stores your last setting in memory and the next time you turn on the fan, fan will operate as the last setting.
The function of Forward & Reverse
Fan must be turned on and rotating. Press and hold the Forward/Reverse button for 3 sec fan will slow down and then change direction (approx. 15 sec). When the fan is slowing down to change direction, the Fan Speed function is disabled until direction has been changed.
Forward
Fan rotates anti-clockwise blowing the air downwards creating the wind chill
effect. Suitable for hot weather conditions.
Reverse
Fan rotates clockwise drawing the air towards the ceiling and circulating
the warm air downwards. This function works best at low speed. Suitable for
air-conditioned conditions.
POWER SUPPLY CONNECTION
CIRCUIT DIAGRAM
IMPORTANT : DO NOT CONNECT THIS REMOTE CONTROL CEILING FAN TO THE DIMMER SWITCH OR REGULATOR.
MAINTENANCE
Due to the fan’s natural movement, connections may get loose after a period of usage. To ensure proper and safe usage, it is highly recommended to inspect and tighten all connections every 6 months.
Cleaning
Cleaning your fan periodically will prolong its new appearance. Basic cleaning
procedures are as follows :
- Use only water and mild soap. Do not use solvents, corrosive or acidic solutions.
- Damp the cloth lightly. Use only soft or lint-free cloth to clean the fan. Rough fabric will scratch the surface.
- Do not bent the blades while cleaning. At the event that blades are bent or damaged, order a new set of blades from the service center or dealer shop.
- There is no need to oil the fan.
TECHNICAL SPECIFICATIONS
Model | ALLY-5B/56 | ALLY-5B/42 |
---|---|---|
No. of Blades | 5 | 5 |
Fan Width | 1420mm (56”) | 1066mm (42”) |
Motor RPM | 80 – 185 | 110 – 240 |
Voltage | 220 – 240V~ 50Hz | 220 – 240V~ 50Hz |
Motor Wattage | 5W – 45W | 5W – 40W |
Nett Weight | 6.5kg | 5.6kg |
CUSTOMER SERVICE CENTRE
If you need any technical assistance or faulty report, please contact our customer service centre at :
Head Office : 6, Jalan Sungai Kayu Ara 32/37, Berjaya Park, Section 32, 40460 Shah Alam, Selangor.
- Tel : 03-5740 6666
- Fax : 03-5740 8220
- Website : www.alphamalaysia.com
- Email : info@alphamalaysia.com
Johor Bahru : 71, Jalan Molek 3/10, Taman Molek, 81100 Johor Bahru.
- Tel : 07-353 4833 / 4933
- Fax : 07-355 4233
Melaka : 19, 19-1 & 19-2, Jalan KSB 11, Taman Kota Syahbandar, 75200 Melaka.
- Tel : 06-292 6292 / 6293
- Fax : 06-292 6296
Ipoh : 11, Jalan Tasek Timur 5, Taman Tasek Indra, 31400 Ipoh, Perak.
- Tel : 05-545 2282 / 547 2282
- Fax : 05-547 6282
Penang : 28, Jalan Icon City, Icon City, 14000 Bukit Mentajam, Penang.
- Tel : 04-506 2366 / 2066 / 2566
- Fax : 04-506 2966
Pahang : A131, TK1, Jalan Wang Ah Jang, Taman Liza, 25100 Kuantan, Pahang.
- Tel : 09-516 5226
- Fax : 09-513 9226