ALPHA Fan AX80-3B/56 Ceiling Fan Instruction Manual
- June 10, 2024
- ALPHA FAN
Table of Contents
Instruction Manual
Model : AX80-3B/56
AX80-5B/40 AX80-5B/46
AX80-5B/56
Version: 2022 V1
SAFETY PROECAUTION
Warning
Installation and maintenance work shall only be performed by qualified
persons, familiar with local code and regulation, and experienced with this
type of appliance.
All field wiring must be installed in accordance with the national wiring
regulation.
Ensure that the rated voltage of the unit corresponds to that of the name
plate before commencing wiring work according to the wiring diagram.
The appliance must be permanently connected to the electricity supply through
a double pole switch having a contact separation of at least 3mm in all poles
The unit must be GROUNDED to prevent possible hazard due to insulation
failure.
The earth wire is approximately 60mm longer than safety wire. This is to
ensure at the event whereby the suspension system fails, the (L) and (N) wire
will break leaving the fan remain earthed to prevent electrocution.
Tighten the blade firmly using a screw driver.
Blades that are detached from the unit during operation will cause serious
injuries and property damages.
This appliance is not intended for use by persons (including children) with
reduced physical, sensory or mental capabilities, or lack of experience and
knowledge, unless they have been given supervision or instruction concerning
use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the
appliances.
Confirm that the power supply has been switched OFF before installing or
servicing the unit. Ensure that the blade is fully static before doing any
maintenance work.
STOP using the ceiling fan when any abnormality or failure occurs.
If unusual oscillating movement is observed, immediately stop using the
ceiling fan and contact the manufacturer, its service agent or suitably
qualified persons.
CAUTION
Please take note of the following important points when installing.
The fixing means for attachment to the ceiling such as hooks or other devices
shall be fixed with a sufficient strength to withstand 4 times the weight of
the ceiling fan.
The mounting of the suspension system shall be performed by the manufacturer,
its service agent or suitably qualified persons.
The fan is to be installed so that the blades are more than 2.5m above the
floor.
Safety cord should not be longer than the earthing conductor.
Should failure of the suspension system occur, the supporting of the fan must
not rely on the earthing conductor. The earthing terminal in the fan assembly
should be such that should any part of the suspension system fall off, the
body of the fan assembly shall effectively earthed.
Ensure that the unit’s panel is closed after service or installation.
Unsecured panels will cause the unit to operate noisily.
Sharp edges and coil surfaces are potential locations which may cause injury
hazards.
Avoid from being in contact with these places.
Before turning off the power supply set the remote controller’s ON/OFF switch
to the “OFF” position.
If this is not done, the unit’s fans will start turning automatically when
power resumes, posing a hazard to service personnel or the user.
Do not operate any heating apparatus too close to the ceiling fan unit or use
in room where mineral oil, oil vapour or oil steam exist, this may cause
plastic part to melt or deform as a result of excessive heat or chemical
reaction.
Avoid the ceiling fan unit from exposing to direct sunlight, this may cause
degradation of plastic material as a result of excessive heat and UV
radiation.
Ensure the colour of wires of the outdoor unit and the terminal markings are
same to the indoors respectively.
Do not use joined and twisted wires for incoming power supply.
Do not place any object in the path of the blades.
Avoid raising objects or your arms near the ceiling fan.
The fan suspension system and blade screw tightening shall be examined yearly.
Replacement of parts of the safety suspension system device shall be performed
by the manufacturer, its service agent or suitably qualified persons. Torque
value for screw/bolts for securing primary suspension system for motor is 2Nm.
PARTS & ACCESSORIES
INSTALLATION INSTRUCTION
Step 1
a. Fix the Rubber Pulley Assembly to the Downrod with Bolt, Washer, Nut and
tighten them firmly
b. then insert the Clevis Pin.
Step 2
a. Remove the Bolt, Clevis Pin, Nut, Washer and Rubber Pulley from the
Downrod.
b. Place the Rubber Pulley onto the ceiling hook and fix back the Bolt, Clevis
Pin, Nut and Washer.
IMPORTANT : CLEVIS PIN MUST BE INSERTED TO PREVENT NUT FROM
LOOSENING.
Step 3
Tie the Safety Wire across the hook as shown and firmly screw the Safety Wire
onto the Downrod.
Step 4
a. Connect the Connectors from Fan and Receiver.
b. Connect the wires from the receiver to House’s Supply Wire.
c. Connect Earth Wire to House Supply Earth Terminal.
Step 5
a. Install the Blades on Motor with Screw.
b. Install the Switch Housing by twisting in.
IMPORTANT : Assemble the Fan Blades only after the ceiling fan is mounted
on the hook.
Step 6
Below shows a complete installation diagram.
TRANSMITTER LEARNING PROCESS
IMPORTANT : DO NOT CONNECT THIS REMOTE CONTROL CEILING FAN TO DIMMER SWITCH OR
REGULATOR.
The receiver & transmitter is pre-programmed in factory. If you wish to
control 2 or more fans using 1 transmitter, the below steps are required.
DO NOT PRESS ANY OTHER BUTTON DURING THIS PROCESS
Step 1
a. Insert the 2 pcs of batteries (provided) into transmitter.
b. Turn on the power supply (wall switch) to the fan.
c. Within 30 sec, press and hold the “LEARN” button for 3 sec. Once the
receiver has detected the frequency, transmitter will “Beep Beep” twice.
Programming process is completed and fan is ready to use. If the fan is not
responding to the transmitter, repeat Step 1b.
TRANSMITTER FUNCTION
IMPORTANT : DO NOT CONNECT THIS REMOTE CONTROL CEOLING FAN TO DIMMER
SWITCH OR REGULATOR .The transmitter & receiver is incorporated with last
memory function. This function stores your last setting in memory and the next
time you turn on the fan, fan will operate as the last setting.
Function of Forward & Reverse
Fan must be turned on and rotating.
Press and hold Forward/Reverse button for 3 sec fan will slow down and then
change direction (approx. 15 sec).
When the fan is slowing down to change direction, the Fan Speed function is
disabled until direction has been changed.
POWER SUPPLY CONNECTION
**CIRCUIT DIAGRAM
**
IMPORTANT : DO NOT CONNECT THIS REMOTE CONTROL CEILING FAN TO DIMMER SWITCH OR REGULATOR.
TECHNICAL SPECIFICATIONS
CUSTOMER SERVICE CENTRE
Alpha Home Appliances Sdn. Bhd. (390258-H)
Head Office : 6, Jalan Sungai Kayu Ara 32/37, Berjaya Park, Section 32, 40460
Shah Alam, Selangor.
Tel : 03-5740 6666
Fax : 03-5740 8220
Website : www.alphamalaysia.com
Email : info@alphamalaysia.com
Johor Bahru : 71, Jalan Molek 3/10, Taman Molek, 81100 Johor Bahru.
Tel : 07-353 4833 / 4933
Fax : 07-355 4233| Penang : 28, Jalan Icon City, Icon City, 14000 Bukit
Mentajam, Penang.
Tel : 04-506 2366 / 2066 / 2566
Fax : 04-506 2966
---|---
Melaka : 19, 19-1 & 19-2, Jalan KSB 11, Taman Kota Syahbandar, 75200 Melaka.
Tel : 06-292 6292 / 6293
Fax : 06-292 6296
Ipoh| Pahang : A131, TK1, Jalan Wang Ah Jang, Taman Liza, 25100 Kuantan,
Pahang.
Tel : 09-516 5226
Fax : 09-513 9226
: 11, Jalan Tasek Timur 5, Taman Tasek Indra, 31400 Ipoh, Perak.
Tel : 05-545 2282 / 547 2282
Fax : 05-547 6282|