ALPHA FAN PRIMA-5B LED Ceiling Fan Instruction Manual
- June 10, 2024
- ALPHA FAN
Table of Contents
- ALPHA FAN PRIMA-5B LED Ceiling Fan
- SAFETY PRECAUTION
- Parts & Accessories
- Installation Instruction
- TRANSMITTER LEARNING PROCESS
- TRANSMITTER FUNCTION
- The function of Forward & Reverse
- POWER SUPPLY CONNECTION
- CIRCUIT DIAGRAM
- MAINTENANCE
- TECHNICAL SPECIFICATIONS
- CUSTOMER SERVICE CENTRE
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
ALPHA FAN PRIMA-5B LED Ceiling Fan
SAFETY PRECAUTION
Warning
Installation and maintenance work shall only be performed by qualified
persons, familiar with local code and regulations, and experienced with this
type of appliance. All field wiring must be installed in accordance with the
national wiring regulation. Ensure that the rated voltage of the unit
corresponds to that of the nameplate before commencing wiring work according
to the wiring diagram. The appliance must be permanently connected to the
electricity supply through a double pole switch having a contact separation of
at least 3mm in all poles
The unit must be GROUNDED to prevent possible hazards due to insulation
failure.
The earth wire is approximately 60mm longer than the safety wire. This is to
ensure at the event whereby the suspension system fails, the (L) and (N) wire
will break leaving the fan remain earthed to prevent electrocution.
Tighten the blade firmly using a screwdriver.
Blades that are detached from the unit during operation will cause serious
injuries and property damage.
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliances. Confirm that the power supply has been switched OFF before installing or servicing the unit. Ensure that the blade is fully static before doing any maintenance work.
STOP using the ceiling fan when any abnormality or failure occurs.
If unusual oscillating movement is observed, immediately stop using the
ceiling fan and contact the manufacturer, its service agent or suitably
qualified persons.
CAUTION
Please take note of the following important points when installing.
The fixing means for attachment to the ceiling such as hooks or other devices
shall be fixed with a sufficient strength to withstand 4 times the weight of
the ceiling fan.
The mounting of the suspension system shall be performed by the manufacturer, its service agent or suitably qualified persons. The fan is to be installed so that the blades are more than 2.5m above the floor.
Safety cord should not be longer than the earthing conductor.
Should failure of the suspension system occur, the supporting of the fan must
not rely on the earthing conductor. The earthing terminal in the fan assembly
should be such that should any part of the suspension system fall off, the
body of the fan assembly shall effectively earthed.
Ensure that the unit’s panel is closed after service or installation.
Unsecured panels will cause the unit to operate noisily.
Sharp edges and coil surfaces are potential locations which may cause injury hazards. Avoid from being in contact with these places.
Before turning off the power supply set the remote controller’s ON/OFF switch to the “OFF” position.
- If this is not done, the unit’s fans will start turning automatically when power resumes, posing a hazard to service personnel or the user.
- Do not operate any heating apparatus too close to the ceiling fan unit or use in a room where mineral oil, oil vapor or oil steam exists, this may cause the plastic part to melt or deform as a result of excessive heat or chemical reaction.
- Avoid the ceiling fan unit from exposing to direct sunlight, this may cause degradation of plastic material as a result of excessive heat and UV radiation.
- Ensure the colour of the wires of the outdoor unit and the terminal markings are the same to the indoors respectively.
- Do not use joined and twisted wires for incoming power supply.
- Do not place any object in the path of the blades. Avoid raising objects or your arms near the ceiling fan.
- The fan suspension system and blade screw tightening shall be examined yearly.
- Replacement of parts of the safety suspension system device shall be performed by the manufacturer, its service agent or suitably qualified persons.
- The torque value for screws/bolts for securing the primary suspension system for the motor is 2Nm.
Parts & Accessories
Installation Instruction
Step 1
- Route all the wires from the Motor through the Motor Bracket.
- Route all the wires through the Downrod.
- Fix the Motor Bracket and Downrod to the Motor Assembly with Bolt, Washer, Nut and tighten them firmly then insert the Clevis Pin.
IMPORTANT:
CLEVIS PIN MUST BE INSERTED TO PREVENT NUT FROM LOOSENING.
Step 2
- Assemble the Canopy and Coupling Cover through the Downrod.
- Fix the Rubber Pulley Assembly to the Downrod with Bolt, Washer, Nut and tighten them firmly, then insert the Clevis Pin.
Step 3
- Remove the Bolt, Clevis Pin, Nut, Washer and Rubber Pulley from the Downrod. Place the Rubber Pulley onto the ceiling hook and fix back the Bolt, Clevis Pin, Nut and Washer.
- Remove the Safety Wire screw and spring washer from the Downrod.
Step 4
Tie the Safety Wire across the hook as shown.
Step 5
- Connect the Connectors from Fan and Receiver.
- Connect the wires from the receiver to House’s Supply Wire.
- Connect Earth Wire to House Supply Earth Terminal.
Step 6
Install the Blades on the Motor with the Screw.
Step 7
Install Lamp Shade by twisting it in.
Step 8
Below shows a complete installation diagram.
TRANSMITTER LEARNING PROCESS
IMPORTANT:
DO NOT CONNECT THIS REMOTE CONTROL CEILING FAN TO THE DIMMER SWITCH OR
REGULATOR.
The receiver & transmitter is pre-programmed in the factory. If you wish to control 2 or more fans using 1 transmitter, the below steps are required.
DO NOT PRESS ANY OTHER BUTTON DURING THIS PROCESS
Step 1
- Insert the 2 pcs of batteries (provided) into the transmitter.
- Turn on the power supply (wall switch) to the fan.
- Within 30 sec, press and hold the “LEARN” button for 3 sec. Once the receiver has detected the frequency, the transmitter will “Beep Beep” twice. The programming process is completed and fan is ready to use. If the fan is not responding to the transmitter, repeat Step 1b.
TRANSMITTER FUNCTION
IMPORTANT:
DO NOT CONNECT THIS REMOTE CONTROL CEILING FAN TO DIMMER SWITCH OR REGULATOR.
The transmitter & receiver is incorporated with last memory function. This function stores your last setting in memory and the next time you turn on the fan, fan will operate as the last setting.
The function of Forward & Reverse
Fan must be turned on and rotating.
Press and hold the Forward/Reverse button for 3-sec fan will slow down and then change direction (approx. 15 sec). When the fan is slowing down to change direction, the Fan Speed function is disabled until the direction has been changed.
Forward
Fan rotates anti-clockwise blowing the air downwards creating the wind chill
effect. Suitable for hot weather conditions.
Reverse
Fan rotates clockwise drawing the air towards the ceiling and circulating the
warm air downwards. This function works best at low speed. Suitable for air-
conditioned conditions.
POWER SUPPLY CONNECTION
CIRCUIT DIAGRAM
IMPORTANT:
DO NOT CONNECT THIS REMOTE CONTROL CEILING FAN TO THE DIMMER SWITCH OR
REGULATOR.
MAINTENANCE
Due to the fan’s natural movement, connections may get loose after a period of usage. To ensure proper and safe usage, inspect the suspension system and tighten all connections every 6 months.
Cleaning
Cleaning your fan periodically will prolong its new appearance. Basic cleaning procedures are as follows :
- Use only lukewarm water. Do not use detergent, corrosive or acidic solution.
- Damp the cloth lightly. Use only soft or lint-free cloth to clean the fan. Rough fabric will scratch the fan surface.
- To cover small scratches, apply a light coat of shoe polish over it.
- There is no need to oil the fan.
TECHNICAL SPECIFICATIONS
Model | PRIMA-5B/56 LED | PRIMA-5B/40 LED |
---|---|---|
No. of Blades | 5 | 5 |
Fan Width | 1420mm (56”) | 1015mm (40”) |
Motor RPM | 70 – 210 | 80- 240 |
Voltage | 220-240V~ 50Hz | 220-240V~ 50Hz |
Motor Wattage | 4W – 45W | 4W – 40W |
LED Wattage | 22W | 22W |
Nett Weight | 6.0kg | 5.7kg |
CUSTOMER SERVICE CENTRE
If you need any technical assistance or a faulty report, please contact our customer service center at:
Alpha Home Appliances Sdn. Bhd. (390258-H)
- Head Office: 6, Jalan Sungai Kayu Ara 32/37, Berjaya Park, Section 32, 40460 Shah Alam, Selangor.
- Tel: 03-5740 6666
- Fax: 03-5740 8220
- Website: www.alphamalaysia.com.
- Email: info@alphamalaysia.com.
- Johor Bahru: 71, Jalan Molek 3/10, Taman Molek, 81100 Johor Bahru.
- Tel: 07-353 4833 / 4933
- Fax: 07-355 4233
- Melaka: 19, 19-1 & 19-2, Jalan KSB 11, Taman Kota Syahbandar, 75200 Melaka.
- Tel: 06-292 6292 / 6293
- Fax: 06-292 6296
- Ipoh: 11, Lalua n Tasek Timur 5, Taman Tasek Indra, 31400 Ipoh, Perak.
- Tel: 05-545 2282 / 547 2282
- Fax: 05-547 6282
- Penang: 28, Jalan Icon City, Icon City, 14000 Bukit Mentajam, Penang.
- Tel: 04-506 2366 / 2066 / 2566
- Fax: 04-506 2966
- Pahang: A131, TK1, Jalan Wang Ah Jang, Taman Liza, 25100 Kuantan, Pahang.
- Tel: 09-516 5226
- Fax: 09-513 9226