SHARP UA-KCP100U-W Air Purifier with Humidifying Function Instruction Manual
- June 13, 2024
- Sharp
Table of Contents
- IMPORTANT SAFETY INSTRUCTIONS
- INSTALLATION GUIDELINES
- FILTER GUIDELINES
- PART NAMES
- OPERATION PANEL
- FRONT DISPLAY
- PREPARATION
- FILTER INSTALLATION
- OPERATION
- CLEAN ION SHOWER MODE
- PLASMACLUSTER ION SPOT MODE
- SELECTING MODE
- PLASMACLUSTER ION ON/OFF
- HOW TO CHANGE VARIOUS SETTINGS
- FILTER MAINTENANCE INDICATOR
- MAIN UNIT / BACK PANEL (Pre-Filter)
- HEPA FILTER / DEODORIZING FILTER
- Plasmacluster Ion Generating Unit 1
- Plasmacluster Ion Generating Unit 2
- TROUBLESHOOTING
- ERROR DISPLAY
- SPECIFICATIONS
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Operation Manual
UA-KCP100U-W
Air Purifier with Humidifying Function
“Plasmacluster” and “Device of a cluster of grapes” are trademarks of Sharp Corporation.
Air Purifier
Air Purifier
With Humidifying Function
FP-J80EU / FP-J60EU
- The number in this technology mark indicates an approximate number of ions supplied into the air of 1 cm 3, which is measured around the center of a room applicable floor area (at 1.2 m height above the floor) when the product is placed close to a wall at the MED mode setting.
A unique combination of Air Treatment Technologies
Triple Filteration System + Plasmacluster
High-Density Plasmacluster 25000
The higher the PCI density is, the more effective PCI has.
Triple Filtration System
TRAP DUST
Pre-filter traps dust larger than approx 240-micron particles.
DECREASES ODOURS
Deodorizing filter absorbs many common household odors.
REDUCES TINY DUST, POLLEN & MOLD
HEPA filter traps 99.97% of particles as small as 0.3 microns.
Unique Airflow
Powerful air suction and unique airflow quickly and efficiently collect dust
and other particles.
Faster airflow at a 20º angle collects dust at lower levels in the room for
more effective cleaning.
Plasmacluster can remove static electricity and can thus prevent dust from
attaching to walls and other surfaces.
Plasmacluster
By emitting a balance of positive and negative ions, Plasmacluster air
treatment is a natural process.
PM2.5 Monitor
- Inform by lighting PM2.5 monitor when Sensitive Dust sensor detects microscopic dust.
- Display the value of PM2.5 in 3 digits.
Plasmacluster Ion Spot Mode
- Recommended when odor and germs adhering to sofa and curtains are concerned.
- Emits high-density Plasmacluster Ions only in the forward directions.
Thank you for purchasing this SHARP Air Purifier.
Please read this manual carefully before using the product.
This manual should be kept in a safe place for handy reference.
Please read before operating your new Air Purifier
The air purifier draws in room air through the air intake, circulates it
through a PreFilter, a Deodorizing Filter, and a HEPA
Filter inside the main unit, and then discharges it through the air outlet.
The HEPA filter can remove 99.97% of dust particles as small as 0.3 microns
that pass through the filter and also help absorb odors.
The Deodorizing Filter gradually absorbs odors as they pass through the
filter. Some odors absorbed by the filters will break down over time, causing
additional odors.
Depending on usage conditions, and especially if the main unit is used in
environments significantly more severe than a normal household, these odors
may become noticeable sooner than expected. If these odors persist, replace
the filters. (page 11)
NOTE
- The air purifier is designed to remove air-suspended dust and odors.
The air purifier is not designed to remove harmful gases such as carbon monoxide contained in cigarette smoke.
The air purifier may not completely remove an odor if the source of the odor is still present.
IMPORTANT SAFETY INSTRUCTIONS
Always follow basic safety precautions when using electrical appliances, including the following:
WARNING – Always observe the following to reduce the risk of electrical shock, fire, or injury: • Read all instructions before using the main unit.
-
Use only a 220 – 240 volt outlet.
-
This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning the use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
-
If the power cord is damaged, it must be replaced by the manufacturer, its service agent, a Sharp authorized Service Centre, or similarly qualified persons in order to avoid a hazard. Contact the nearest Service Centre for any problems, adjustments, or repairs.
-
Do not repair or disassemble the main unit yourself.
-
Be sure to remove the power plug, before performing maintenance, when removing and attaching and replacing the filter, and when not using it for a long time. Failure to do so can cause a short circuit resulting in electrical shock or fire.
-
Do not use the main unit if the power cord or plug is damaged or if the connection to the wall outlet is loose.
-
Periodically remove dust from the plug.
-
Do not insert fingers or foreign objects into the air intake or air outlet.
-
When removing the power plug, always hold the plug and never pull on the cord. Failure to do so can cause a short circuit resulting in electrical shock or fire.
-
Be careful not to damage the power cord, it may cause electric shock, excess heat, or fires.
-
Do not remove the plug when your hands are wet.
-
Do not place the main unit near or on hot objects, such as stoves or heaters, or where it may come into contact with steam.
-
Do not operate the main unit in rooms where aerosol insecticides are present. Do not operate the main unit in rooms where there is oily residue, incense, sparks from lit cigarettes, or chemical fumes in the air. Do not operate the main unit in places where it may get wet, such as a bathroom.
-
Be cautious when cleaning the main unit. Strong corrosive cleansers can damage the exterior.
-
Do not expose the main unit to water. Doing so can cause a short circuit or electrical shock.
NOTE – What to do if the main unit interferes with radio or TV reception If the air purifier interferes with radio or television reception, try one or more of the following measures: -
Adjust or reposition the receiving antenna.
-
Increase the distance between the main unit and the radio or TV.
-
Connect the equipment into an outlet on a circuit different from that of the radio or TV receiver.
-
Consult the dealer or a qualified radio or TV technician.
CAUTIONS CONCERNING OPERATION
- Do not block the air intake or air outlet.
- Always operate the main unit in an upright position.
- Do not move the main unit when it is in operation.
- When moving the main unit, use the handles on both sides.
- If the main unit is on easily damaged flooring, an uneven surface, or thick piled carpet, lift it up when moving.
- Do not operate the main unit without the filters properly installed.
- Do not wash and reuse the HEPA filter and the Deodorizing filter. Doing so will not improve filter performance and can also cause electric shock or operating malfunctions.
- Clean the exterior with a soft cloth only. Do not use volatile fluids or detergents. The main unit surface may be damaged or cracked with Benzine, paint thinner or polishing powder. In addition, the sensors may malfunction as a result.
- Keep the main unit away from water.
- Do not scrub the Back Panel hard during its maintenance.
INSTALLATION GUIDELINES
- Avoid locations where the sensors are exposed to direct wind. Doing so can cause the main unit to malfunction.
- Avoid locations where furniture, fabrics, or other objects can come in contact with the main unit and interfere with the intake and outtake of air.
- Avoid locations where the main unit is exposed to condensation or drastic changes in temperature. Appropriate room temperature is between 0 – 35 ºC.
- Place the main unit on a level and stable surface with sufficient air circulation. When placed on heavy carpet, the main unit may vibrate slightly.
- Avoid locations that generate grease or oily smoke. Doing so can cause the main unit exterior to crack and the sensors to malfunction.
- The dust collecting ability of the main unit is effective even when the main unit is as close to 3 cm from the wall,the surrounding walls and floor may get dirty. Please place the main unit at a distance from the wall. The wall directly behind the air outlet may become dirty over time. When using the main unit for an extended period of time at the same location, periodically clean the walls adjacent to it.
FILTER GUIDELINES
- Follow the instructions in this manual for proper filter care and maintenance. (page 11)
PART NAMES
MAIN UNIT
1 | Operation Panel |
---|---|
2 | Air Outlet (Front / Back) |
3 | Cleanliness Monitor |
4 | Front Display |
5 | Main Unit |
6 | Handle (2 locations: Left and Right) |
7 | Front Louver |
8 | Back Panel (Pre-Filter) |
9 | Air Inlet |
10 | Deodorizing Filter |
11 | HEPA Filter |
12 | Sensor Filter Sensor (Internal) Odour / Dust (sensitive)/ |
Temperature’ / Humidity (‘ FP-J80EU)
13| Unit (Plasmacluster Ion Generating Unit)
14| Unit Holder
15| Unit Cover
16| *Unit Cleaning Brush
17| Power Cord, Plug**
- The Unit refers to Plasmacluster Ion Generating Unit.
(BACK)
OPERATION PANEL
Press the button with “ ” to start.
FRONT DISPLAY
1 | Power ON/OFF Button |
---|---|
2 | AUTO Button, Indicator Light |
3 | CLEAN ION SHOWER Button, Indicator Light |
4 | Plasmacluster Ion SPOT Button, Indicator Light |
5 | MODE Button, Indicator Light |
6 | Timer Button (Press 3 sec.) FILTER RESET Button |
7 | DISPLAY Button (Press 3 sec.) CHILD-LOCK Button |
8 | Child-Lock Indicator Light |
9 | Light Sensor |
10 | PM2.5 Monitor |
Indicates the Dust (sensitive) Sensor detects microscopic dust.
11| Dust Monitor
Indicates the Dust (sensitive) Sensor detects usual dust.
12| Odour Monitor
Indicates the Odour Sensor detects odors.
13| Unit Replacement Indicator Light
14| Filter Maintenance Indicator Light
15| ON Timer Indicator Light
16| OFF Timer Indicator Light
17| Plasmacluster Ion Light
18| DISPLAY
• PM2.5 Monitor
19| Cleanliness Monitor Indicates the air purity of the room in 5 levels with
color changes.
PREPARATION
Always be sure to remove the power plug from the wall outlet.
FILTER INSTALLATION
-
Remove the Back Panel.
-
2Remove the plastic bag from each filter.
-
- Install the Back Panel.
OPERATION
START / STOP
AUTO MODE
The fan speed is automatically controlled depending on the 3 detections. (Dust
(sensitive) / Odour / Light) NOTE
- Front Display, Cleanliness Monitor automatically switches ON and Darker based on room brightness.(When light control is set to “Auto”. (page 9))
CLEAN ION SHOWER MODE
The main unit releases Plasmacluster ions with a strong airflow and collects dust while decreasing static electricity for 10 minutes. After that, the DUST sensor sensitivity is automatically increased and quickly detects impurities, and cleans the air powerfully for 50 minutes.
NOTE
- When the operation finishes after 60 minutes, the main unit will return to the prior operation mode. It is able to change the other mode during this mode.
- The Plasmacluster Ion can not be turned “OFF”.
PLASMACLUSTER ION SPOT MODE
Use this mode when you want to remove adhering odour, germs, and other substances from clothes, sofas, and curtains.
NOTE
- Emits high-density Plasmacluster Ions only in the forward direction.
- Discharges stronger air for 8 hours. When the operation finishes, the main unit will return to its prior operation mode.
- The Plasmacluster Ion can not be turned “OFF”.
SELECTING MODE
SLEEP:
The main unit will operate quietly, and the fan speeds automatically switch
depending on the number of impurities in the air and room brightness.
The Front Display and Cleanliness Monitor automatically switch darker or OFF
based on room brightness.
Room is bright: light is darker
Room is dark: light is OFF
POLLEN:
The DUST SENSOR sensitivity is automatically increased and quickly detects
impurities such as dust and pollen and cleans the air powerfully.
ON TIMER
Select the length of time you want.
The Main Unit automatically starts once the selected time passes.
OFF TIMER
Select the length of time you want.
The Main Unit automatically stops once the selected time is reached.
CHILD LOCK
The operation panel will be locked.
ON CANCELLATION
SELECTING DISPLAY (with the Main Unit ON)
PLASMACLUSTER ION ON/OFF
When the Plasmacluster function is ON, the Plasmacluster Ion light is on. (page 5) (with the Main Unit ON)
HOW TO CHANGE VARIOUS SETTINGS
You can change the functions listed in the table below
-
Turn the Main Unit power OFF.
-
Select “Function number”.
-
Select “Setting number”.
-
Press Power ON/OFF Button to finish the setting.
Function | Setting |
---|
Light Control
You can select the brightness of the Front Display and Cleanliness Monitor.|
Light automatically switches based on room brightness.
Room brightness | Front Display and Cleanliness Monitor |
---|
ALL MODE
(Except SLEEP)| SLEEP MODE
Bright| ON| Darker
Dark| Darker| Turn off
Auto Restart
If the Main Unit is unplugged or if there is a power failure, the Main Unit will resume operation with the previous settings after power is restored.
|
Adjusting Sensor Sensitivity (F3-F5)| Light Sensor|
---|---
Dust (sensitive) Sensor|
Odour Sensor|
- When set to “Turn off”, the “Darker” light illuminates for 8 seconds after operation starts and then the light turns off.
FILTER MAINTENANCE INDICATOR
The Filter Maintenance Indicator Light will turn on after approximately 720 hours of operating.
This is a reminder to perform the maintenance of the back panel (pre-filter).
After maintenance, reset the Filter Maintenance Indicator Light.
MAIN UNIT / BACK PANEL (Pre-Filter)
Wipe with a dry, soft cloth.
Remove the dust gently with a cleaning tool such as a vacuum cleaner.
NOTE How to clean hard to remove dirt.
Back Panel
-
Add a small amount of neutral detergent to the water and soak for about 10 minutes.
CAUTION
Do not apply excessive pressure when scrubbing the back panel. -
Rinse off the neutral detergent with clean water.
-
Completely dry the filter in a well-ventilated area.
Sensor Filter
- Remove the back panel.
- Remove the sensor filter.
- If the sensor filter is very dirty, wash it with water and dry it thoroughly.
HEPA FILTER / DEODORIZING FILTER
Remove the dust on the filters.
Maintain only the tagged surface. Do not clean up the opposite surface. The filter is fragile, so be careful not to apply too much pressure.
CAUTION Do not wash the filters. Do not expose to sunlight. (Otherwise, these filters may lose efficacy.) Both surfaces can be maintained. The filter may be broken if being too much power is applied to it, so please handle it with care.
Some odors absorbed by the filters will break down over time, causing
additional odors. Depending on usage conditions, and especially if the Main
Unit is used in environments significantly more severe than a normal
household, these odors may become noticeable sooner than expected.
Replace the filter in those cases or if dust is unable to be removed after
maintenance.
LIFE OF FILTERS
Filter life varies depending on the room environment, usage conditions, and
location of the Main Unit.
The lifespan of the HEPA filter and Deodorizing filter and replacement
suggestions are based on purifying a room in which 5 cigarettes are smoked per
day and the Main Unit’s dust collection and deodorizing performance have
declined to half the level of a new filter.
We recommend replacing the filter more frequently if the Main Unit is used in
conditions significantly more severe (PM2.5 etc.,) than a normal household.
-
HEPA Filter:
About 10 years after opening -
Deodorizing Filter:
About 10 years after opening
REPLACEMENT
Consult your dealer when purchasing a replacement filter.
Disposing of filters
Dispose of used filters according to local laws and regulations.
HEPA Filter material:
- Polypropylene
- Polyethylene
Deodorizing Filter material:
- Polypropylene
- Polyester
- Activated carbon
Plasmacluster Ion Generating Unit 1
-
Remove the unit cover, and pull out the unitholder.
-
Remove dust from the electrode section.
-
Insert the unit holder in the Main Unit, and install the unit cover.
CAUTION
- Do not clean with anything other than the unit cleaning brush. Doing so could lead to failures in the unit.
- A bent electrode could be cut off and dropped during the cleaning process, but it will not change the performance.
- Do not touch the electrode directly. Doing so could lead to pain/itching.
- Do not transform the electrode section. Doing so can damage it.
- Do not touch the connection terminals. Doing so can damage them.
Plasmacluster Ion Generating Unit 2
UNIT REPLACEMENT INDICATOR
When the total operation time exceeds 17,500 hours, the Unit Replacement
indicator will flash to indicate that the Plasmacluster Ion Generating Unit
seeds replacement.
Operating time|
---|---
17,500 hours
Flash slowly| Replace the Plasmacluster Ion Generating Unit
19,000 hours Flash quickly| Stop the emission of the Plasmacluster ions.
- The replacement time is not related to the selected operation mode.
REPLACEMENT
Consult your dealer when purchasing a replacement Plasmacluster
Ion Generating Unit.
Model: IZ-C90MEU Remove the claw of unitholder (1 ), and remove the
Plasmacluster Ion Generating Unit (2).
Disposing of Plasmacluster Ion Generating Unit
Dispose of used Plasmacluster Ion Generating Unit according to local laws and
regulations. material: • Polybutylene terephthalate • electronic parts
TROUBLESHOOTING
Before calling for service, please review the list below, since the problem may not be the product malfunction.
Odour and smoke persist.
- Check the filters. If they appear to be extremely dirty, clean or replace them.
- Check if the plastic bag is removed from the filter. (Page 6)
The Cleanliness Monitor is blue even when the air is not clean.
- The air may have been dirty when the main unit was plugged in. Unplug the main unit, wait one minute, and then plug the main unit in again.
The Cleanliness Monitor light is red even when the air is clean.
- Dirty or clogged dust (sensitive) sensor openings interfere with sensor operation. Gently clean the sensor filter or the back panel.
The Main Unit makes a clicking or ticking sound.
- The main unit may make clicking or ticking sounds when it is generating ions.
Air discharged from the Main Unit has an odor.
- Check to see if the filters are extremely dirty.
- Clean or replace the filters.
The Main Unit does not operate when cigarette smoke is in the air.
- Make sure the Main Unit is installed in a location in which the sensors can detect cigarette smoke.
- Check to see if the dust (sensitive) sensor openings are blocked or clogged. If they are blocked or clogged, clean the sensor filter or the back panel.
Smell from a new filter.
- Immediately after removing the plastic bag, a slight odor may occur. This odor is not harmful to filter performance or human exposure.
The FILTER Maintenance Indicator light is on.
- Whenever after performing maintenance of the filters, connect the power cord to an outlet and then touch the Filter Reset Button. (page 10)
The Front Display is turned off.
- When Light control is set to “Turn off”, the light is always off. If you do not want the light to be off, set Light control to “Auto” or “Darker” setting. (page 9)
The Cleanliness Monitor changes color frequently.
- The Cleanliness Monitor automatically changes color when the dust (sensitive) sensor and odor sensor detect impurities. If you are concerned about the change, you can change sensor sensitivity. (page 9)
The Main Unit’s Display does not match the weather report or another hygrometer or thermometer in the room.
- Outdoor and indoor as well as the home environment (the volume of traffic nearby, number of stories in-home, etc.) may cause a reading different than those data.
- There is a difference in the level within the same room.
ERROR DISPLAY
| The concentration of Plasmacluster ion is descending.
Maintain the Plasmacluster Ion Generating
Unit (electrode section).
---|---
| Is the Plasmacluster Ion Generating Unit inserted properly?
****Pull out the Plasmacluster Ion Generating Unit and insert it to the end
again, and then
carry out the operation again.
| • Unplug the Main Unit, wait one minute, and then plug the Main Unit in
again.
SPECIFICATIONS
Model | FP-J80EU | FP-J60EU |
---|---|---|
Power supply | 220 – 240 V 50 – 60 Hz | |
Fan Speed Adjustment | MAX | i MED |
Fan Speed (m3/hour) | 480 | 288 |
Noise Level (dBA) | 47 | 45 |
Rated Power (W) | 48 | 28 |
Standby Power (W) | 1.3 | 1.2 |
Recommended Room Size (m2) *1 | – 62 | – 48 |
High density Plasmacluster ion
recommended room size (m2) .2| – 35| – 26
Cord Length (m)| 2 0
Dimensions (mm)| 416 (W) x 291 (D) x 728 (H)
Weight (kg)| 10.6| 10.0
1 • The recommended room size is appropriate for operating the main unit of maximum fan speed.
• The recommended room size is an area in which a given amount of dust
particles can be removed in 30 minutes. (JEM1467)
2 • Room size in which approximately 25000 ions per cubic centimeter can be measured in the center of the room when the main unit is placed next to a wall, is running at MED mode settings, and is at a height of approximately 1.2 meters from the floor.
Standby Power
When the main unit’s power plug is inserted in a wall outlet it consumes
standby power in order to operate electrical circuits. To conserve energy,
unplug the power cord when the main unit is not in use Attention : Your
product is marked with this symbol. It means that used electrical and
electronic products should not be mixed with general household waste. There is
a separate collection system for these products.
A. Information on Disposal for Users (private households)
-
In the European Union
IF YOU WISH TO DISPOSE OF THIS EQUIPMENT, DO NOT USE THE ORDINARY WASTE BIN, AND DO NOT PUT THEM INTO A FIREPLACE!
Used electrical and electronic equipment should always be collected and treated separately in accordance with local law.
The separate collection promotes an environment-friendly treatment, recycling of materials, and minimizing final disposal of waste. IMPROPER DISPOSAL can be harmful to human health and the environment due to certain substances! Take USED EQUIPMENT to a local, usually municipal, collection facility, where available.
If in doubt about disposal, contact your local authorities or dealer and ask for the correct method of disposal.
ONLY FOR USERS IN THE EUROPEAN UNION, AND SOME OTHER COUNTRIES;
FOR INSTANCE NORWAY AND SWITZERLAND: Your participation in separate collection is requested by law.
The symbol shown above appears on electrical and electronic equipment (or the packaging) to remind the users of this.
Users from PRIVATE HOUSEHOLDS are requested to use existing return facilities for used equipment. Return is free of charge.
If the equipment has been used for BUSINESS PURPOSES, please contact your SHARP dealer who will inform you about take-back. You might be charged for the costs arising from take-back. Small equipment (and small quantities) might be taken back by your local
collection facility. For Spain: Please contact the established collection system or your local authority for take-back of your used products. -
In other Countries outside the EU
If you wish to discard this product, please contact your local authorities and ask for the correct method of disposal.
For Switzerland: Used electrical or electronic equipment can be returned free of charge to the dealer, even if you don’t purchase a new product. Further collection facilities are listed on the homepage of www.swico.ch or www.sens.ch.
B. Information on Disposal for Business Users.
-
In the European Union
If the product is used for business purposes and you want to discard it:
Please contact your SHARP dealer who will inform you about the take-back of the product. You might be charged for the costs arising from take-back and recycling. Small products (and small amounts) might be taken back by your local collection facilities.
For Spain: Please contact the established collection system or your local authority for take-back of your used products. -
In other Countries outside the EU
If you wish to discard of this product, please contact your local authorities and ask for the correct method of disposal.
SHARP CORPORATION
Visit our website:
www.sharphomeappliances.com
Or contact us:
Printed in Thailand TINS-B270KKRZ 19M – 1
References
- SENS eRecycling – Stiftung für Recycling von Elektro- und Elektronikgeräten
- Sharp Consumer Products Europe - Sharp Europe
- Swico - Der Wirtschaftsverband für die digitale Schweiz
- Mobile applications - Intellectual property rights - Sharp Europe
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>