WARRANTY

ULTRA 9000

MULTIFUNCTION PUMP

ETL SAFETY INSTRUCTION

IMPORTANT SAFETY INSTRUCTIONS

WARNING -To guard against nay, basic safety precautions should be observed, including the
following:

READ AND FOLLOW ALL SAFETY INSTRUCTIONS

CAUTION: Aways comet the pump when not use, before ang remain pars and before cleaning.
– Do not allow pump to run dry. Pump must be immersed in water completely.
– This pump is to be used in a out protected by a ground fault circuit interrupted.

WARNING Risk of electric shock – This pump is supplied with a grounding conductor and grounding-type attachment plug. To reduce the risk of electric shock, be certain that it is connected only to a properly grounded, grounding- type receptacle.

– To reduce the risk of electric shock, install only on a circuit protected by a Ground

– Fault Circuit – Interrupter (GFCI).

– To reduce the risk of electric shock, use only on portable self-contained fountain no large than 5 feet in any dimension.

– This pump has not been investigated for use in swimming pool or marine areas.

– To avoid possible electric shock, special care mshould be taken since water is employed in the use of aquarium or pond equipment.

For each of the following situations, do not attempt repairs by yourself. Return the appliance to an authorized service facility
for service or discard the appliance.

  1. Do not operate any appliance if it has a damaged cord or plug, or if it doesn’t work
    properly or has been dropped or damaged in any manner.

  2. To avoid the possibility of the appliance plug or receptacle getting wet, position
    aquarium stand and tank or the fountain to one side of a wall-mounted receptacle
    to prevent water from dripping onto the receptacle or plug.
    A “drip-loop” (Pic. A) should be arranged by the user for each cord connecting an
    aquarium appliance to a receptacle.

The “drip-loop” is the part of the cord below the level of the receptacle or the connector if an extension
cord is used, which prevents water travelling along the cord and coming in contact with the receptacle.
If the plug or socket does get wet, DON’T unplug the cord. Disconnect the fuse or circuit breaker that
supplies power to appliance. Then unplug and examine for presence of water in the receptacle.

  1. Close supervision is necessary when any appliance is used by near children.

  2. To avoid injury, do not contact moving parts or hot parts such as heaters, reflectors, lamp bulbs and similar.

  3. Always unplug an appliance from an outlet when not in use, before putting on or taking off parts and before cleaning.
    Never yank cord to pull plug from outlet. Grasp the plug and pull to disconnect.

  4. Do not use an appliance for other than intended use. The use of attachments, not recommended or sold
    by the manufacturer of the appliance, may cause an unsafe condition.

  5. Do not install or store the appliances where it will be exposed to the weather or to temperatures below
    freezing.

  6. Make sure an appliance mounted on a tank is securely installed before operating it.

  7. Read and observe all the important notices of the appliance.

  8. If an extension cord is necessary, a cord with a proper rating should be used. A cord rated for less
    amperes or watts than the appliance rating may overheat. Care should be taken to arrange the cord so
    that it will not be tripped over or pulled.

  9. This appliance has a polarized plug (one blade is wider than other). As a safety feature, this plug will
    fit in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still
    does not fit, contact a qualified electrician. Never use with an extension cord unless plug can be fully
    inserted. Do no attempt to defeat this safety feature.

GROUNDING INSTRUCTIONS

This appliance should be grounded to minimize the possibility of electric shock. This appliance is equipped
with an electric cord having an equipment grounding conductor and a grounding type plug. The plug must
be plugged into an outlet that is installed and grounded in accordance with all appropriate codes and
ordinances.

This appliance is for use on a nominal 120-volt circuit, and has a grounding plug that looks like the plug
illustrated in (I). A temporary adapter which looks like the adapter illustrated in (II) and (III) may be used
to connect this plug to a two-pole receptacle as shown in (II) if a grounded outlet is not available. The
temporary adapter should be used only until a grounded outlet is not available. The temporary adapter
should be used only until a grounded outlet can be installed by a qualified electrician. The green-colored
rigid ear (lug, and the like) extending from the adapter must be fastened to a permanent ground such as
a grounded outlet box.

SAVE THESE INSTRUCTION

ULTRA900

TECHNICAL SPEC
Q max 8500 l/h
H max 6.5 m
Max power consumption 110 W – 0.15 CV
Solids handling 8 mm
Liquid type Clear grey water
Max. temperature 35° C
Application Submerged
Cable lenght 10 mt.
Warranty 3 + 2 year

INSTASLLATION USE AND MAINTENACE

installation pump

Dear Customer
THANK YOU for choosing ULTRA 9000, a submersible pump designed and built to pump turbid water without
fibres. ULTRA 9000 can be used mainly for domestic use with continuous or automatic operation via the
integrated electronic level switch, for draining basements and garages subject to flooding, for pumping drainage
wells, for pumping rainwater collection wells or infiltrations from gutters, to empty swimming pools or pool
covers with the aid of the horizontal suction setting supplied. If used continuously, ULTRA 9000 is also ideal for
ponds, fountains, waterfalls, hydroponic applications and aquariums.

GENERAL SAFETY INSTRUCTION

ULTRA900 is made in conformity with the national and international security law.

  1. Check that the tension on the pump’s label match’s7 101the network tension. The pump has to be supplied by a
    differential switch (protector), through which the nominal current is lower or equal to 30mA.

  2. These pumps can be used only submersed in water.

  3. Before connecting the pump to the electric network, check that the cable and the pump are not damaged.

  4. The pump has a type Z cable link. The cable and the plug cannot be substituted or repaired; in case of
    damage of them substitute the entire pump.

  5. CAUTION: disconnect all the submersed electrical products before doing any maintenance in the water;
    in case the plug or the electric outlet are damaged, disconnect the general switch before disconnecting the
    electric supply cable.

  6. The pump must not work without water to avoid damages to the motor.

  7. The pump can be used in liquids or in environment with a temperature not higher than 35° C / 95° F.

  8. Do not use the pump for uses different to those for which it has been designed as, i.e. in bathroom or similar
    applications.

  9. Avoid to use the pump with corrosive and abrasive liquids.

  10. The pump has not been designed for people with handicap and children if they are not supervised by a
    person responsible for their safety.

  11. To avoid that accidental drips wet the plug or the socket, make a loop with the cord under the socket level
    (Pic. A).

  12. Avoid to take the pump by the cord during the installation or maintenance.

  13. The pump can be used only in the above mentioned applications.

WARNING
Use in cellars, basements, swimming pools, etc. it is allowed only if the electrical system is characterized by
safety measures according to the international regulations in force.
The pump is equipped with a carrying handle, which can also be used to lower it into wells or deep excavations
by means of a rope to be fixed on the hole present.
The pump must not be transported, lifted or operated suspended using the power cord. Any damage to the
power cord requires replacement of the pump and not repair of the cord.
It is therefore necessary to make use of specialized and qualified personnel, in possession of the requisites
required by current regulations. Qualified personnel should also be used for all electrical repairs which, if
performed incorrectly, could cause damage and injury.
The pump must never be run dry: however, there is an electronic protection that switches off the pump in the
event of dry running. The manufacturer is not liable for malfunctioning of the pump if it is tampered with or
modified. In the event that the bottom of the sump, where the pump is to operate, is heavily soiled, it is advisable
to provide a support on which to rest the pump in order to avoid blockages in the suction grille.

COMPONENTS

The ULTRA 9000 pump has been designed to allow the
almost total disassembly of its components, to facilitate
correct use, simple maintenance and ensure long life.
Below is the list of individual parts and related spare parts
(Pic.1) – exploded view:

1. Motor body completely submersible and insulated with two-component resin
2. Rotor assembly with flange, impeller and bearing;
3. Rear Ceramic Bearing (Extraction Hook Accessory)
4. Rubber seals
5. Volute including grid adjustable in height using the 4
feet;
6. Interchangeable outlets: vertical and 90°;
7. Security lock for outputs;
8. Float for automatic ON-OFF function;
9. Float’s cover
10. Graduated hose connector

INSTALLATION – USE AND ADJUSTMENT

For the physical installation of the pump it is necessary to proceed as follows:

  • Unwind the power cord of the pump in an area where it cannot be damaged in any way.

  • If required, thread a rope (for the recovery of the pump) though the hole in the cover (Pic.2).

  • The pump is pre-assembled with a vertical outlet: if you wish to use the 90° one, follow the instructions in
    (Pic.3). The outlets have a 1” ½ GAS male thread. It is possible to connect the stepped hose connector
    supplied or any other type of fitting with that thread;

  • Place the pump in a flat area that is easily accessible for maintenance operations;

  • If the pump is not stable, adjust one or more feet separately (Pic.4);

  • To suck the water up to the minimum level of 5 mm allowed by the pump, leave the grate closed (Pic.5);

  • If this requirement is not met, it is advisable to adjust the grille completely open (Pic.6) to obtain
    maximum pump performance;

  • Position the cursor on ON if you want to operate the pump continuously;

  • Position the cursor on AUTO if you want to take advantage of the integrated electronic level switch; (Pic.7)

IMPORTANT

The electronic board incorporated in the pump has been programmed to guarantee 3 levels of protection:

Locked Rotor Protection:   Locked or abnormal rotor function may occur due to excessive dirt. In
this case the internal electronic card will activate 10 attempts to restart the pump correctly. If the pump
does not restart automatically after 10 attempts, it will switch off. In this case, to restart the pump it will be
necessary to remove the power supply plug from the socket, wait about 10 seconds before re-inserting
the plug.
Dry Running Protection: protection of the motor in case of operation without water. The pump stops
if it runs without water. The electronic board will make 10 restart attempts. If there is still not enough water,
the pump will go into stand-by. To restart it, unplug and plug it back in or move the cursor between ON and
AUTO or wait for the water level to trigger the integrated electronic level switch. When the pump is taken
out of the water, the motor stops
Thermal Protection it comes into operation automatically to prevent damage to the motor when the sensor incorporated in the pump detects a signi cant increase in ambient temperature.

ATTENTION! Do not underestimate the magnetic force of the rotor assembly. If you accidentally lose your
grip a little and the spindle hits the pure ceramic rear bearing, the risk of damaging it or the bearing is very high.
Damage of this type leads to high repair costs.

MAINTENANCE
All repair and maintenance operations must be carried out only after having disconnected the pump from the
power supply.
Periodic cleaning of the float that pilots the electronic level switch is recommended.

Proceed as follows:
• Open the lid of the float (Pic.8):
• Extract the float (Pic.8a), clean it under a jet of water with the help of a soft brush if necessary. Also
clean the seat if it is dirty;
• Insert the float again with the writing TOP facing up;
• Close the lid of the float.
For routine maintenance, cleaning the rotor unit is sufficient. For this operation you will have to (Pic.9):
• Undo the four screws accessible from the bottom of the grille Pic.9a)
• Undo the two screws (Pic.9b) accessible by removing the safety block of the outputs (7);
• Remove the volute and the grid (5). In this way it will be possible to extract the rotor complete with FLange
(2); (Pic.10)
• Clean the components under a jet of water, possibly using a soft brush. Reassemble the parts by carrying
out all the above operations in reverse order. For extraordinary maintenance involving the replacement of
the rotor-impeller unit (2) proceed as for the previous point except reassemble a new rotor-impeller unit
(2) in place of the worn one.

INSTRUCTION FOR THE CORRECT DISCHARGE OF THE PRODCUT ACCORDING TO EU

DIRECTIVE 2002/96/EC

When used or broken, the product does not have to be discharged with the other waste. It can be delivered to
the specific electric waste collection centers or to dealers who give this service. Discharge separately an electric
tool avoid negative consequences for the environment and for the Health and allows to regenerate the materials
so to have a great saving of energy and resources.

WARRANTY

SICCE guarantees this product (see Exclusions below) to the original purchaser against defects of materials
and workmanship for a period of five (3+2) years from the date of original purchase, except for the pump’s
impeller, which is guaranteed for a period of six (6) months. This warranty is limited to repair or replacement
(at Sicce’s option) of defective product only and does not cover loss of fishes and plants of the pond, personal
injury, property loss, or damage arising from the use of the product. We recommend to keep the original proof
of purchase to validate the warranty. Warranty claims must be submitted to the retailer where you purchased the
product. Failure to present proof of purchase attached to the claim will invalidate the right to the guarantee. By
connecting to the website www.sicce.com, in the appropriate session, you can request assistance if it has not
been possible to contact the dealer. Also in this case the proof of purchase will be a fundamental requirement
for the correct execution of the return procedure. Any warranty herein shall run concurrently with, and not in
addition to, any minimum warranty periods established by applicable law. The claimant must obtain a “Return
Merchandise Authorization” at the time of filing before sending any product for warranty or technical service.
The purchaser bears the cost of shipping to and from the service center or repair station.
EXCLUSIONS. This warranty does not cover the following: Damage resulting from accident, misuse, abuse,
lack of reasonable care, use of the product that is other than normal or ordinary, using the project in abnormal
working conditions or any other failures not resulting from defects in materials or workmanship.
Damage
resulting from modification, tampering with or attempted repair by anyone other than Sicce or its designee.

  • Transfer of the product to someone other than the original purchaser. * Subjecting the product to electrical
    service not specified in the packaging; the original purchaser is responsible for providing adequate electrical
    facilities.”

FIND OUT HOW TO GET YOUR PRODUCT GUARANTEED FOR 5 YEARS

To improve our service and our customers’ satisfaction, Sicce offers the possibility of adding a 2 year extension
(5 years total) to the warranty by simply registering your product on our website www.sicce.com in “Support/
Product Registration” Fill-in the form and upload the product’s purchase receipt. After having correctly inserted
all your data, complete the warranty extension request.

SICCE S.r.l.
Via V. Emanuele, 115 – 36050 Pozzoleone (VI) – Italy
Tel. +39 0444 462826 – Fax +39 0444 462828
P. IVA / VAT 02883090249
info@sicce.com · www.sicce.com
SICCE US Inc.
infous@sicce.com · www.sicce-us.com
SICCE AUSTRALIA Pty Ltd
info@sicce.com.au · www.sicce.com.au

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals