IMPORTANT SAFETY INSTRUCTIONS
WARNING – To guard against injury, basic safety precautions should be observed, including the following:
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
CAUTION: Always disconnect the pump when not in use, before adding or removing parts and before cleaning. –
- Do not allow pump to run dry. Pump must be immersed in water completely.
- This pump is to be used in a circuit protected by a ground fault circuit interrupter
WARNING: Risk of electric shock – This pump is supplied with a grounding conductor and grounding-type attachment plug. To reduce the risk of electric shock, be certain that it is connected only to a properly grounded, grounding- type receptacle.
- To reduce the risk of electric shock, install only on a circuit protected by a Ground – Fault Circuit – Interrupter (GFCI).
- To reduce the risk of electric shock, use only on portable self-contained fountain no large than 5 feet in any dimension.
- This pump has not been investigated for use in swimming pool or marine areas.
- To avoid possible electric shock, special care should be taken since water is employed in the use of aquarium or pond equipment. For each of the following situations, do not attempt repairs by yourself. Return the appliance to an authorized service facility for service or discard the appliance.
-
Do not operate any appliance if it has a damaged cord or plug, or if it doesn’t work properly or has been dropped or damaged in any manner.
-
To avoid the possibility of the appliance plug or receptacle getting wet, position aquarium stand and tank or the fountain to one side of a wall-mounted receptacle to prevent water from dripping onto the receptacle or plug.
A “drip-loop” (Fig. A) should be arranged by the user for each cord connecting an aquarium appliance to a receptacle.
The “drip-loop” is the part of the cord below the level of the receptacle or the connector if an extension cord is used, which prevents water travelling along the cord and coming in contact with the receptacle.
If the plug or socket does get wet, DON’T unplug the cord. Disconnect the fuse or circuit breaker that supplies power to appliance. Then unplug and examine for presence of water in the receptacle. -
Close supervision is necessary when any appliance is used by near children.
-
To avoid injury, do not contact moving parts or hot parts such as heaters, reflectors, lamp bulbs and similar.
-
Always unplug an appliance from an outlet when not in use, before putting on or taking off parts and before cleaning.
Never yank cord to pull plug from outlet. Grasp the plug and pull to disconnect. -
Do not use an appliance for other than intended use. The use of attachments, not recommended or sold by the manufacturer of the appliance, may cause an unsafe condition.
-
Do not install or store the appliances where it will be exposed to the weather or to temperatures below freezing.
-
Make sure an appliance mounted on a tank is securely installed before operating it.
-
Read and observe all the important notices of the appliance.
-
If an extension cord is necessary, a cord with a proper rating should be used. A cord rated for less amperes or watts than the appliance rating may overheat. Care should be taken to arrange the cord so that it will not be tripped over or pulled.
-
This appliance has a polarized plug (one blade is wider than other). As a safety feature, this plug will fit in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician. Never use with an extension cord unless plug can be fully inserted. Do no attempt to defeat this safety feature.
GROUNDING INSTRUCTIONS
This appliance should be grounded to minimize the possibility of electric shock. This appliance is equipped with an electric cord having an equipment gounding conductor and a grounding type plug. The plug must be plugged into an outlet that is installed and grounded in accordance with all appropriate codes and ordinances.
This appliance is for use on a nominal 120-volt circuit, and has a grounding plug that looks like the plug illustrated in (I). A temporary adapter which looks like the adapter illustrated in (II) and (III) may be used to connect this plug to a two-pole receptacle as shown in (II) if a grounded outlet is not available. The temporary adapter should be used only until a grounded outlet is not available. The temporary adapter should be used only until a grounded outlet can be installed by a qualified electrician. The green-colored rigid ear (lug, and the like) extending from the adapter must be fastened to a permanent ground such as a grounded outlet box.
SAVE THESE INSTRUCTIONS
Dear Customer,
thank you for choosing your new pump for aquarium, turtles kit , small
fountains and any other applications where you need to recirculate water.
GENERAL SAFETY INSTRUCTION
MIMOUSE is made in conformity with the national and international security laws.
-
Check that the tension on the pump’s label matchs the network tension. The pump has to be supplied by a differential switch (protector), through which the nominal current is lower or equal to 30mA.
-
These pumps can be used only submersed in water.
-
Before connecting the pump to the electric network, check that the cable and the pump are not damaged.
-
The pump has a type Z cable link. The cable and the plug cannot be substituted or repaired; in case of damage of them substitute the entire pump.
-
CAUTION: disconnect all the submersed electrical products before doing any maintenance in the water; in case the plug or the electric outlet are wet, disconnect the general switch before disconnecting the electric supply cable.
-
The pump must not work without water to avoid damages to the motor.
-
The pump can be used in liquids or in environment with a temperature not higher than 35° C / 95° F.
-
Do not use the pump for uses different to those for which it has been disegned as, i.e. in bathroom or similar applications.
-
Avoid to use the pump with corrosive and abrasive liquids.
-
The pump has not been designed for people with handicap and children if they are not supervised by a person responsible for their safety.
-
To avoid that accidental drips wet the plug or the socket, make a loop with the cord under the socket level (Fig. A).
-
Avoid to take the pump by the cord during the installation or maintenance.
-
The pump can be used only in the above mentioned applications and it is only for internal use.
-
If the pump or the filter is supplied with a cable 10 metres long, or a cable more than 6 feet long for the American type (USA), these appliances are intended for outodoor use as required by the International standards.
USE AND REGULATION
The MIMOUSE pump has a fixed water outlet pipe 10 mm high with an external diameter of 13 mm which allows connection of both flexible pipes with an internal diameter of 12 mm and rigid pipes with external diameter 13 mm.
An accessory coupling pipe is available and allows the fitting of many other
types and sizes of pipes which can be easily found in the market.
The pump is equipped with anti vibration pads which are useful for eliminating
any noise due to small vibrations of the pump.
The water flow rate may be varied by adjusting the flow regulator according to
the user necessities.
MAINTENANCE
MIMOUSE is a pump with exceptional performance, ideal for use in small spaces
thanks to its compact dimensions.
Its maintenance requirements are minimum, but very important to ensure correct
operation.
Every 1-2 months remove the front A and gently remove the rotor B, wash all
the parts in fresh water, gently removing any accumulated scale.
Reassemble the parts in inverse order.
The side suction grilles also need cleaning periodically to allow a
continuous, constant passage of water; use a small brush to remove all the
scale deposits.
NSTRUCTIONS FOR THE CORRECT DISCHARGE OF THE PRODUCT ACCORDING TO EU DIRECTIVE 2002/96/EC
When used or broken, the product does not have to be discharged with the other waste. It can be delivered to the specific electric waste collection centers or to dealers who give this service. Discharge separately an electric tool avoid negative consequences for the environment and for the Health and allows to regenerate the materials so to have a great saving of energy and resources.
WARRANTY
This product is guaranteed against defects of materials and workmanship for a period of 2 years from the date of purchase, except the rotor B. The warranty certificate must be filled in by the dealer and must accompany the pump if it is returned for reparation, along with the cash register receipt or similar document. The warranty covers the replacement of the defective parts. In case of improper use, tampering or negligence by the buyer or user, the guarantee is void and expires immediately. The guarantee is also void in absence of the cash register receipt or similar document. The expenses for shipping the pump to and from the factory, or the repair station, have to be paid by the buyer.
ATTENTION!
The limestone deposits and the natural wear-out of the components might cause
a raise of the pump’s noise. However, they do not affect the good functioning
of the pump. In this case, we recommend you to replace the impeller.