CDC-25122-XCN1A Arrowg+ard Blue Two-Lumen Hemodialysis Catheterization for High Volume Infusions Instructions
- June 13, 2024
- Arrow
Table of Contents
Arrowg+ ard Blue® Two-Lumen Hemodialysis Catheterization for High Volume Infusions
Contents:
1:00| Three-Lumen Catheter: 12 Fr. (4.06 mm OD) x 20 cm Pressure
Injectable Radiopaque Polyurethane
with Blue Flex Tip®, Extension Line Clamps
---|---
1:00| Spring-Wire Guide, Marked: .035″ (0.89 mm) dia. x 23-5/8″ 60 cm)
(Straight Soft Tip on One End -“J” Tip on
Other) with Arrow® Glide Wheel™ Wire Advancer
1:00| Catheter: 18 Ga. x 2-1/2″ (6.35 cm) Radiopaque over 20 Ga. RW
Introducer Needle
1:00| Injection Needle: Safety Glide™ 1 25 Ga. x 1″ (2.54 cm)
1:00| Blunt Fill Needle: 18 Ga. x 1-1/2″ (3.81 cm)
1:00| Pressure Transduction Probe
1:00| Introducer Needle:
Echogenic 18 Ga. x 2-1/2″ (6.35 cm) XTW and 5 mL Arrow® Raul erson
Spring-Wire Introduction Syringe
1:00| Injection Needle:
Safety Glide™ 1 22 Ga. x 1-1/2″ (3.81 cm) and 5 mL Luer-Slip
Syringe
1:00| Syringe: 3 mL Luer-Lock
1:00| Tissue Dilator: 10 Fr. (3.5 mm) x 10.2 cm
1:00| Tissue Dilator: 12 Fr. (4.0 mm) x 14 cm
3:00| 10 mL Luer-Lock Pre-Filled Saline Syringe
1:00| 5 mL 1% Lidocaine HCl Solution and Alcohol Prep
2:00| 3 mL Applicator 2% CHG and 70% IPA Chlora Prep® 2 One-Step
Solution with Hi-Lite Orange™ Tint
1:00| Sharps Away® II Locking Disposal Cup
1:00| Sharps Away® Disposal Cup
1:00| Maximal Barrier Drape™ with 4″ fenestration
1:00| Towel
1:00| Needle Holder
1:00| Safety Scalpel: #11
1:00| Checklist/CLIP Sheet
1:00| Sterile Procedure Sign
1:00| Medication Label: 1% Lidocaine
2:00| Gauze Pad: 2″ x 2″ (5 cm x 5 cm)
5:00| Gauze Pad: 4″ x 4″ (10 cm x 10 cm)
1:00| Surgical Apparel: Impervious Gown
1:00| Dressing: Tegaderm® 3 CHG 3-1/2″ x 4-1/2″ (8.5 cm x 11.5 cm)
1:00| Transducer Cover: 14 cm x 147 cm
1:00| Surgical Apparel: Mask with Eye Shield
1:00| Surgical Apparel: Bouffant Cap
1:00| Suture: 3-0 Silk with Curved Needle
1:00| Tubing±: 20″ (50 cm) Extension
1:00| Hemo Hopper® Fluid Receptacle
1A trademark of Becton, Dickinson and Company.
2 A registered trademark of CareFusion or one of its subsidiaries.
3A registered trademark of 3M Company.
±Precaution: Contains Phthalate: DEHP. Warning: The results of certain animal
experiments have shown phthalates to be potentially toxic to reproduction.
Proceeding from the present state of scientific knowledge, risks for male
premature infants cannot be excluded in the case of long-term exposure or
application. Medical products containing phthalates should be used only
temporarily with pregnant women, nursing mothers, babies and infants. Not made
with natural rubber latex. Store between 20 – 25°C (68 – 77°F). Mow
International provides the enclosed medication label(s) for your convenience.
Please ensure that these labels are applied to the correct syringe and
corresponding medication. Contraindications: The Arrow large-bore two-lumen
catheter is not designed for long-term (k 30 days) hemodialysis or for use in
patients with thrombosed vessels. The Arrowg+ard Blue antimicrobial catheter
is contraindicated for patients with known hypersensitivity to chlorhexidine,
silver sulfadiazine, and/ or sulfa drugs.
Priming Volume*
Distal
Proximal| 1.60 mL
1.50 mL
---|---
- Priming volumes are approximate and are done without accessories.
Flow (mL/min)
† In vitro tests performed using 3:1 glycerine/saline at 37°C.
LBL068965 R00 (2023-04)
Documents / Resources
|
ARROW CDC-25122-XCN1A Arrowg+ard Blue Two-Lumen Hemodialysis Catheterization
for High Volume
Infusions
[pdf] Instructions
CDC-25122-XCN1A Arrowg ard Blue Two-Lumen Hemodialysis Catheterization for
High Volume Infusions, CDC-25122-XCN1A, Arrowg ard Blue Two-Lumen Hemodialysis
Catheterization for High Volume Infusions
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>