HAYWARD AQL2-Wx-PS Series Remote Display or Keypad Instruction Manual
- June 13, 2024
- Hayward
Table of Contents
HAYWARD AQL2-Wx-PS Series Remote Display or Keypad
Product Information
The product is an Electrolytic Chlorine Generator designed for basic pool maintenance. It is compatible with Pro Logic PS-4/8/16 models and Aqua Logic PS-4/8/16 systems running main software r2.00 or higher. The product comes in two color options, black (AQL2-WB-PS) and white (AQL2-WW-PS). It is covered by a one-year warranty provided by Hayward/Goldline.
COMPATIBILITY : This display/keypad is compatible with all Pro Logic PS-4/8/16 models and for all Aqua Logic PS-4/8/16 systems running main software r2.00 or higher.
Product Usage Instructions
- Free Chlorine and pH Adjustment:
- Ideal Range: Free Chlorine – 1.0 to 3.0 ppm, pH – 7.2 to 7.8
- Adjustment Required: Turn the output dial up to increase or down to decrease chlorine levels. Alternatively, adjust the pump filtration time.
- Too High: Add muriatic acid
- Too Low: Add soda ash
- Alkalinity Adjustment:
- Ideal Range: 80 to 120 ppm
- Add baking soda to increase alkalinity
- Add acid as required to decrease alkalinity
- Salt Adjustment:
- Ideal Range: 2700 to 3400 ppm
- Add salt as required to increase levels
- Stabilizer Adjustment:
- Ideal Range: 60 to 80 ppm
- Add cyanuric acid to increase stabilizer levels
- Calcium Adjustment:
- Ideal Range: 200 to 400 ppm
- Add calcium to increase levels
- Drain and add water to decrease levels
- Electrolytic Cell Inspection and Cleaning:
- Refer to the section in the manual for instructions
For the latest manual revisions, additional information, and helpful service, refer to the official website: www.hayward-pool.com
INSTALLATION
Remote Display Installation Instructions:
Mounting
Push a screwdriver blade through the slot and lift up the cover If bezel will be used, snap the baseplate into the bezel before mounting Screw the baseplate in the desired position using screws supplied by the installer. The AQL2-Wx- PS-x Remote Display/Keypad must be mounted indoors or in a weather protected area (rain should never hit the display/keypad). Up to 3 remote display/keypads can be installed. The display/keypad is designed to mount onto a standard electrical utility box (same size as used for a triple light switch) or can be mounted directly onto any wall surface. When selecting a location, note that the wire to the Pro Logic/Aqua Logic main unit must be no more than 500 feet long. Follow the steps below:
- Remove display/keypad baseplate from the cover by inserting a screwdriver in the slot shown below. Lift up on the cover while pushing gently with the screw-driver.
- If bezel will be used, snap baseplate into bezel before mounting.
- Screw the baseplate in the desired position (screws supplied by installer).
Note : The provided warranties have certain exclusions. It is important to follow the installation, operation, and maintenance recommendations mentioned in the owner’s manual. Any tampering, improper installation, or use of unauthorized parts may void the warranty. For technical support and service, contact Hayward/Goldline at the current rates.
Wiring
The Pro Logic or Aqua Logic main unit can connect to a maximum of 3 remote
display/keypads. Use four conductor cable (typically phone cable) to connect
the remote display keypad with the Pro Logic/Aqua Logic Control Center as
shown below. The maximum wiring distance is 500ft. (160m). Note that the
terminals on both the Pro Logic/Aqua Logic main unit and the remote
display/keypad are numbered: Connect 1 to 1, 2 to 2, etc.
If multiple remote display/keypads are installed: Never connect more than 2
wires to any terminal block. Two remotes can be wired back to the Pro
Logic/Aqua Logic main unit or the second display/keypad (and third, if
applicable) can be “daisy chained” with one display/keypad wired to the next.
The maximum wire run from the Pro Logic/Aqua Logic main unit to the furthest
remote display/keypad is 500 ft. (160m).
When power is turned on, all the LED indicators will flash briefly, the display back-light will illuminate, and the following display will appear for a short period of time:
The “r4.00” is the software revision level. The actual revision level for your
display/keypad may be different.
Refer to the Pro Logic or Aqua Logic Operation Manual for complete operating
in-structions.
TROUBLESHOOTING
-
Display/keypad not functioning (no display, no LEDs illuminated)
If the display/keypad located on the main unit is working correctly, the most likely cause is that wires 1 and 4 are either open circuited or reversed. Check wiring. If none of the displays are working, check that 120V power is being applied to the main control and that the 3A fuse (violet) is not blown. -
Display backlight turns off after a period of time
The display backlight should always illuminate when you press any key on the unit. If it turns off after a period of time, you can stop this by pressing the menu key (possibly multiple times) until “Settings Menu” appears. Next press the “<” or “>” key (possibly multiple times) until “Display Light” appears. At this point, pressing either “+” or “-“ will allow you to select either “Always On” or “On for 60 sec.”. After you have selected the desired operation, press the “Menu” button to lock in your setting. Note that this selection applies to this display/keypad only. Repeat the process of each display/keypad in the system. -
Display backlight always on
The display backlight should always illuminate when you press any key on the unit. If it remains on after 60 seconds have elapsed since the last button push, you can stop this by pressing the menu key (possibly multiple times) until “Settings Menu” appears. Next press the “<” or “>” key (possibly multiple times) until “Display Light” appears. At this point, pressing either “+” or “-“ will allow you select either “Always On” or “On for 60 sec.”. After you have selected the desired operation, press the “Menu” button to lock in your setting. Note that this selection applies to this display/keypad only. Repeat the process for each display/keypad in the system.
The display/keypad received data from an Aqua Logic system running software earlier than r2.00. This keypad is not compatible with these sys-tems. Another cause for this problem may be that the local display/keypad in the main Pro Logic/Aqua Logic control unit is not connected or not functioning. If this is the case, connect and/or replace the local display/keypad and then cycle power to the Pro Logic/Aqua Logic off and then back on to reset the system. Call the Hayward Tech support department.
The display/keypad is not receiving any communication from the Pro Logic/Aqua Logic main control unit. The most likely cause of this problem is a broken wire or “open circuit” in wires “2” and/or “3” in the cable between the display/keypad and the Pro Logic/Aqua Logic main control unit. If you are unable to find the problem, contact the Hayward Tech support depart-ment Monday through Friday, from 8AM to 8PM eastern time.
The display/keypad is receiving data from the main Pro Logic/Aqua Logic control unit however that data contains errors and is unusable. The most likely cause of this problem is that wires “2” and “3” in the cable between the control unit and the display/keypad are crossed. If you are unable to find the problem, contact the Hayward Tech support department Monday through Friday, from 8AM to 8PM eastern time.
An internal problem has occurred in the display/keypad. Remove the dis- play/keypad from the wall mount base (see diagram on page 1) and write down the model number and serial number of the display/keypad. Next, call the Hayward Tech support department (Monday through Friday, from 8AM to 8PM eastern time) to find out how to obtain a replacement display/key-pad.
LIMITED WARRANTY
(effective 04/01/09) Hayward/Goldline warrants its Pro Logic and E-Command
pool automation products as well as its Aqua Rite, Aqua Rite Pro, Aqua Plus
and SwimPure chlorination products to be free of defects in materials and
workmanship, under normal use and service, for a period of three (3) years.
Hayward/Goldline also warrants its Aqua Trol chlorination products to be free
of defects in materials and workmanship, under normal use and service for a
period of one (1) year. These warranties are applicable from the initial date
of installation on private residential swimming pools in the US and Canada.
Hayward/Goldline warrants all the above-identified pool automation and
chlorination prod-ucts installed on commercial swimming pools and on swimming
pools outside of the US and Canada for a period of one (1) year. Likewise,
Hayward/Goldline warrants all accessories and replacement parts for the above-
identified pool automation and chlorination products for a period of one (1)
year. Each of these warranties is not transferable and applies only to the
original owner.
Proof of purchase is required for warranty service. If written proof of
purchase is not provided, the manufacturing date code will be the sole
determinant of the date of installation of the product. To obtain warranty
service or repair, please contact the place of purchase or the nearest
Hayward/Goldline authorized warranty service center. For more information on
authorized service centers please contact the Hayward/Goldline Technical
Service Support Center (61 Whitecap Road, North Kingstown RI, 02852) or visit
the Goldline web site at www.goldlinecontrols.com or the Hayward website at
www.haywardnet.com.
WARRANTY EXCLUSIONS:
- Material supplied or workmanship performed by others in process of installation.
- Damage resulting from improper installation including installation on pools larger than the product rating.
- Problems resulting from failure to install, operate or maintain the product(s) in accordance with the recommendations contained in the owners manual(s).
- Problems resulting from failure to maintain pool water chemistry in accordance with the recommendations in the owners manual(s).
- Problems resulting from tampering, accident, abuse, negligence, unauthorized repairs or alternations, fire, flood, lightning, freezing, external water, degradation of natural stone used in or immediately adjacent to a pool or spa, war or acts of God.
DISCLAIMER.
THE EXPRESS LIMITED WARRANTIES ABOVE CONSTITUTE THE ENTIRE WARRANTIES WITH
RESPECT TO THE ABOVE-IDENTIFIED HAYWARD/GOLDLINE POOL AUTOMATION AND
CHLORINATION PRODUCTS AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR
IMPLIED, INCLUDING WAR-RANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR
PURPOSE. THESE WARRANTIES GIVE YOU SPECIFIC LEGAL RIGHTS, AND YOU MAY ALSO
HAVE OTHER RIGHTS OF EQUIPMENT, LOST PROFITS OR REVENUE, COSTS OF RENTING
REPLACEMENTS, AND OTHER ADDITIONAL EXPENSES, EVEN IF THE SELLER HAD BEEN
ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE
EXCLUSION OF LIMITATION OF INCI-DENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE
LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU.
NO WHOLESALER, AGENT, DEALER, CONTRACTOR OR OTHER PERSON IS AUTHORIZED TO
PROVIDE, SUPPLEMENT OR MODIFY ANY WARRANTY ON BEHALF OF HAYWARD/GOLDLINE.
THESE WARRANTIES ARE VOID IF THE PRODUCT HAS BEEN ALTERED IN ANY WAY AFTER
LEAVING THE FACTORY. FOR THE ABOVE-IDENTIFIED CHLORI-NATION PRODUCTS, THESE
WARRANTIES ALSO ARE VOID IF, DURING THE WARRANTY PERIOD, YOU USE A REPLACEMENT
CHLORINATOR CELL OTHER THAN AN UNMODIFIED, NEW HAYWARD/GOLDLINE CHLORINATOR
CELL PUR-CHASED FROM HAYWARD/GOLDLINE. IF A WARRANTY BECOMES VOID, YOU STILL
MAY PURCHASE SERVICE AND/OR TELEPHONE TECHNICAL SUPPORT AT THE THEN CURRENT
TIME AND MATERIAL RATES.
ELECTROLYTIC CHLORINE GENERATOR BASIC POOL MAINTENANCE REQUIREMENTS
Refer to www.hayward-pool.com for latest manual revisions, additional information and helpful service.
092147C RevD
Copyright © 2010 Hayward
References
- Pool Automation | In Ground Pool Automation - Hayward Pool Products
- Welcome to Hayward Residential and Commercial Pool Products
- Welcome to Hayward Residential and Commercial Pool Products
Read User Manual Online (PDF format)