Leviton 476TM-652 Twist & Mount Patch Panel User Manual

June 13, 2024
Leviton

Leviton-logo

Leviton 476TM-652 Twist & Mount Patch Panel

Leviton 476TM-652 Twist & Mount Patch Panel-product

IMPORTANT INSTRUCTIONS

  1. Read and understand all instructions. Follow all warnings and instructions marked on the product.
  2. Do not use this product near water-e.g., near a tub, wash basin, kitchen sink, or laundry tub, in wet basement, or near swimming pool.
  3. Never push objects of any kind into this product through openings, as they may touch dangerous voltages.
  4. SAVE THESE INSTRUCTIONS.

SAFETY INFORMATION

  1. Never install communications wiring or components during a lightning storm.
  2. Never install communications components in wet locations unless the components are designed specifically for use in wet locations.
  3. Never touch uninsulated wires or terminals unless the wiring has been disconnected at the network interface.
  4. Use caution when installing or modifying communications wiring or components.
  5. To prevent electrical shock, each opening must be filled with a module.

Twist & Mount Patch Panel

To view installation videos, pictures, descriptions, specifications, or instruction sheets for the Twist & Mount Patch Panel, please visit our website at: www.leviton.com.

INTRODUCTION

Application

Leviton’s Twist & Mount Patch Panel is designed to connect telephone and data services for home or small office cabling. The panel fits into Leviton’s Structured Media® enclosures (SMC), featuring installer friendly installation hooks and Push-Lock Pin mounting. The Twist & Mount Patch Panel provides for standards-compliant patching of Category 5e and/or Category 6 Structured Cabling to sources in the SMC and can be used with various Leviton modules to provide for voice or data distribution.

Configurations

Leviton offers the following Twist & Mount Patch Panels for your telephone and data distribution needs:

Combination CAT 5e and CAT 6 12-Port Twist & Mount (476TM-652):

Consists of:

  • 6 Ports of Category 5e
  • 6 Ports of Category 6
  • Route Gigabit Ethernet to 6 locations
  • Route telephone, fax, and modem to 6 locations
  • 2 Expansion slots

CAT 5e 12-Port Twist & Mount (476TM-512):

Consists of:

  • 12 Ports of Category 5e
  • Route telephone, fax, modem, and Ethernet to 12 locations
  • 2 Expansion slots

CAT 6 12-Port Twist & Mount (476TM-612):

Consists of:

  • 12 Ports of Category 6
  • Route telephone, fax, modem, and Gigabit Ethernet to 12 locations
  • 2 Expansion slots

Combination CAT 5e and CAT 6 Twist & Mount (476TM-654):

Consists of:

  • 12 Ports of Category 5e
  • 12 Ports of Category 6
  • Route Gigabit Ethernet to 12 locations
  • Route telephone, fax, and modem to 12 locations

CAT 5e Twist & Mount (476TM-524):

Consists of:

  • 24 Ports of Category 5e
  • Route telephone, fax, modem, and Ethernet to 24 locations

CAT 6 Twist & Mount (476TM-624):

Consists of:

  • 24 Ports of Category 6
  • Route telephone, fax, modem, and Gigabit Ethernet to 24 locations

CAT 5eCAT 5eCAT 6CAT 6

Package Contents

The following items are included with your Panel:

  • Twist & Mount Patch Panel preloaded with CAT5e and/or CAT6 boards
  • Plastic 110 Termination Tool
  • Four Push-Lock Pins and Grommets
  • Wiring ID Labels

Required Tools

For wire termination the following tools are required:

  • Angle cutters (if using the provided Plastic 110 Termination Tool)
  • Professional Impact Tool with 110-cutting Blade
  • Wire Cutters
  • UTP Wire Stripping Tool

GETTING STARTED

  • Planning
    Plan your cable routing carefully to determine which distribution panel will satisfy your requirements. Determine the number of outlet locations required for phone, fax, modem, and Ethernet and/or Gigabit Ethernet service.

  • Define
    Label each wire with its corresponding location or ID number. Use the provided Wiring Identification Chart at the end of these instructions to map the placement of your wires in the Panel, and for reference when filling out the wiring ID labels for the front of the Twist & Mount Panel. The numbers on the termination side of the Twist & Mount correspond with the jack position on the front of the Panel.

  • Organize
    In the SMC, separate the voice wires from the data wires for ease of termination. Determine how you will route your wires into the Panel for termination. You can bring your wires in through the top or bottom of the Panel feeding the wires into the wire channels which will hold them in place during termination and when twisting the panel for mounting. Generally if conduit is used you will want to come in through the bottom of the panel to provide an adequate service loop.

INSTALLATION

Twist & Mount Patch Panel

During cable termination the Twist & Mount Panel must be mounted with the 110 IDCs facing out of the enclosure. Make sure the top of the panel is facing the top of the SMC. Align the installation hooks with the grid holes on the back of the enclosure and slide the Panel down so it hangs securely in the enclosure.

Leviton 476TM-652 Twist & Mount Patch Panel-fig- \(5\)

Cable Termination:

Run twisted pair cable to the Panel from the wall outlets. Strip approximately 3” of outer jacket from the cable. Match the color coding of the wires to the colors on the 110 IDC color coded wire termination diagram. All four pairs of each cable must be terminated. Make sure to terminate Category 5e wire to Category 5e ports and Category 6 wire to Category 6 ports. Slide each wire into the wire holder in its associated channel.

NOTE: The TIA-570-B Residential Wiring Standard calls for T568A wiring termination. Certain building installations may require T568B termination. To use T568B termination, flip the color coded wire termination diagram over and wire according to the color code shown for T568B. Wall Outlets must be wired to match the chosen termination standard.
For voice, each pair of wires corresponds to one line from the phone company when wire is used to distribute phone service. (Line 1=Blue pair, Line 2=Orange pair, Line 3=Green pair, Line 4=Brown pair.) (Figure 1)

Using Plastic Tool Provided:

  1. Push the appropriate wire into the color designated 110 IDC slot with the tool (Figure 2).
  2. Trim excess wire with diagonal cutters (Figure 3).

Using professional Punch Tool:

  1. Orient tool with cutting blade as shown (Figure 4).

  2. Push straight down until tool seats and trims wire, making a clicking noise.Leviton 476TM-652 Twist & Mount Patch Panel-fig- \(6\)

  3. MOUNTING
    After terminating all cables and all wires, slide the panel up and pull straight out and away from the enclosure to release the installation hooks. Twist the patch panel 180° horizontally and align the mounting pins with the grid holes in the back of the enclosure. Feed excess cable into the wall cavity and with the mounting pin plungers in the “out” position, press the unit into the grid in the desired location, secure by pushing the plungers in. Dress service loop of wires along the side of the enclosure.

  4. LABEL
    Reference the completed Wiring Identification Chart (Step 1) when filling out the labels for the front on the Panel. Label each jack accordingly with location and service type (data or telephone). Slide the labels from the top of the Panel into the label holders. Peel the protective film from the front and back of each label cover and insert into the label holders so that it lays on top of the paper label to protect it.

WIRING IDENTIFICATION CHART

  • Jack: 1 Location:_____
  • Jack: 2 Location:_____
  • Jack: 3 Location:_____
  • Jack: 4 Location:_____
  • Jack: 5 Location:_____
  • Jack: 6 Location:_____
  • Jack: 7 Location:_____
  • Jack: 8 Location:_____
  • Jack: 9 Location:_____
  • Jack: 10 Location:_____
  • Jack: 11 Location:_____
  • Jack: 12 Location:_____
  • Jack: 13 Location:_____
  • Jack: 14 Location:_____
  • Jack: 15 Location:_____
  • Jack: 16 Location:_____
  • Jack: 17 Location:_____
  • Jack: 18 Location:_____
  • Jack: 19 Location:_____
  • Jack: 20 Location:_____
  • Jack: 21 Location:_____
  • Jack: 22 Location:_____
  • Jack: 23 Location:_____
  • Jack: 24 Location:_____

LIMITED 2 YEAR WARRANTY AND EXCLUSIONS

Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship under normal and proper use for two years from the purchase date. Leviton’s only obligation is to correct such defects by repair or replacement, at its option, if within such two year period the product is returned prepaid, with proof of purchase date, and a description of the problem to Leviton Manufacturing Co., Inc., Att: Quality Assurance Department, 201 North Service Road, Melville, N.Y. 11747.

This warranty excludes and there is disclaimed liability for labor for removal of this product or reinstallation. This warranty is void if this product is installed improperly or in an improper environment, overloaded, misused, opened, abused, or altered in any manner, or is not used under normal operating conditions or not in accordance with any labels or instructions. There are no other or implied warranties of any kind, including merchantability and fitness for a particular purpose, but if any implied warranty is required by the applicable jurisdiction, the duration of any such implied warranty, including merchantability and fitness for a particular purpose, is limited to two years.

Leviton is not liable for incidental, indirect, special, or consequential damages, including without limitation, damage to, or loss of use of, any equipment, lost sales or profits or delay or failure to perform this warranty obligation. The remedies provided herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise.

FREQUENTLY ASKED QUESTIONS

What is the Leviton 476TM-652 Twist & Mount Patch Panel?

The Leviton 476TM-652 is a Twist & Mount Patch Panel designed for structured cabling systems. It provides a convenient and organized way to terminate and manage Ethernet cables in a network or data center.

How many ports does the patch panel have?

The Leviton 476TM-652 Twist & Mount Patch Panel typically comes with 12 ports, allowing you to terminate up to 12 Ethernet cables.

What is the mounting type of this patch panel?

The patch panel features a Twist & Mount design, making it easy to install and secure to the mounting bracket without the need for additional screws or tools.

Can I use this patch panel for both Cat5e and Cat6 cables?

Yes, the Leviton 476TM-652 Twist & Mount Patch Panel is compatible with both Cat5e and Cat6 Ethernet cables, providing flexibility for various cabling requirements.

Does the patch panel support Gigabit Ethernet speeds?

Yes, the patch panel is designed to support Gigabit Ethernet speeds (up to 1000 Mbps) and is suitable for high-speed network applications.

What is the material used for the construction of the patch panel?

The patch panel is usually constructed with durable and sturdy materials like metal, ensuring long-lasting performance and protection for the terminated cables.

Is the Twist & Mount Patch Panel compatible with shielded Ethernet cables?

Yes, the patch panel is generally compatible with both shielded and unshielded Ethernet cables.

Does the Leviton 476TM-652 Patch Panel come with cable management features?

The patch panel may include integrated cable management features, such as cable ties or guides, to help organize and route the cables neatly.

Can I use this patch panel for PoE (Power over Ethernet) applications?

Yes, the patch panel is designed to support PoE applications, making it suitable for powering PoE-enabled devices like IP cameras or access points.

What is the termination style used in this patch panel?

The Leviton 476TM-652 Twist & Mount Patch Panel typically uses 110-style punch-down terminations for the Ethernet cables.

Is the patch panel rack-mountable?

Yes, the patch panel is designed for rack mounting in standard network racks or cabinets, providing easy integration into structured cabling setups.

Can I use this patch panel in a residential network setup?

Yes, the Leviton 476TM-652 Patch Panel is suitable for both residential and commercial network installations.

Does the patch panel come with pre-numbered labels for port identification?

Yes, the patch panel usually includes pre-numbered labels for easy identification and organization of the Ethernet ports.

Can I use this patch panel with both T568A and T568B wiring standards?

Yes, the patch panel is compatible with both T568A and T568B wiring standards for Ethernet termination.

Is the patch panel compatible with keystone jacks?

No, the Leviton 476TM-652 Twist & Mount Patch Panel does not use keystone jacks; instead, it directly terminates Ethernet cables.

DOWNLOAD THE PDF LINK:Leviton 476TM-652 Twist & Mount Patch Panel User Manual

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals