Literature 5KW Wall Mount Air Handler ECM User Manual

June 13, 2024
Literature

5KW Wall Mount Air Handler ECM

Product Information:

This product is a Wall Mount Air Handler with an ECM (5KW)
blower motor. It is designed to be connected to a thermostat for
controlling the air conditioning and heating functions. The product
operates on a supply voltage of 208V or 240V and has a transformer
that provides a 24V output for control purposes. The air handler
features various components including a control board, heater, DC
relay, AC relay, main air limit, backup limit, and an ECM motor. It
provides multiple wiring options for different configurations.

Product Usage Instructions:

1. Before starting the installation, refer to the provided
installation instructions for the correct blower motor speed tap
connection as it may vary from the shown wiring diagram.

2. Ensure that the supply voltage is compatible with the air
handler (208V or 240V).

3. Connect the thermostat to the air handler using the following
wiring connections:

Terminal Color Description
R Red Power (24V)
G Green Fan Control
W White Heating Control
Y Yellow Cooling Control
C Gray Common (24V)

4. Connect the air handler to the power supply using the
appropriate high voltage wiring connections.

5. Connect the field wiring to the air handler using the low
voltage wiring connections as shown in the diagram.

6. If using a 208V supply voltage, ensure that the circuit
breaker is compatible and properly installed.

7. Once all the wiring connections are made, turn on the power
supply.

8. Use the control board to set the desired operating mode
(Heat, Cool, Off).

9. The air handler is now ready to provide conditioned air based
on the thermostat settings.

WIRING DIAGRAM

TO THERMOSTAT

Wall Mount Air Handler ECM (5KW)
NOTES: 1. The blower motor speed tap connection may not be as shown.Refer to installation instructions provided
with unit to set DIP switches for theappropriate heating and cooling speed setting for your application. 2. Disconnect all power before servicing. 3. The transformer may have a dual voltage primary tap. Match the tap positionwith the supply voltage used. 4. If the internal wiring is replaced, use only 105°C copper wire of the same gauge. 5. Connect 24VAC/40VA Class 2 circuit to thermostat. See air handler installation instructions for control circuit.

III

SEE NOTE 5

R

RED

C

W

G

GREEN

Y

GRAY GRAY

WHITE WHITE

YELLOW

TRANSFORMER

24V

240V

R

RED

Y

WG C R

CLASS 2

C

GRAY

208V

L2 STANDARD (ATO) AUTOMOTIVE

BLADE-TYPE FUSE,

L1

3 AMP, 32VDC MAX

L1

HEAT COOL OFF

L1

ON

L2

5 4 3 2 1 1 2 3 4 5

CONTROL

L2

BOARD

12 3 4 56 7 8

HEATER

BLACK RED

WHITE BLACK

DC RELAY

NO COM

BLACK

BLACK

HARNESS

BLACK

Remarques 1. Le connecteur de vitesse du moteur du ventilateur peut différer de
l’illustration. Consultez les Instructions d’installation. 2. Débranchez toutes les sources d’alimentation avant l’entretien. 3. Le transformateur peut avoir un robinet principal à double tension.
Agencez la position du robinet au type de tension de l’installation. 4. Si le câblage interne est remplacé, utilisez seulement un fil de cuivre
105° C du même gabarit. 5. Branchez le circuit de 24 VAC/40 VA de Classe 2 au thermostat. Voyez
les Directives d’installation de l’appareil de traitement de l’air pour le circuit de commande.

COM NO

RED

AC RELAY

ELEMENT

MAIN AIR LIMIT
RED

BACKUP LIMIT
RED

RED WHITE

ORANGE

BLACK BLUE
YELLOW ORANGE
RED BROWN
WHITE
YELLOW/GREEN
GRAY

ECM MOTOR

CIRCUIT BREAKER

L1

L2

SUPPLY VOLTAGE

LEGEND:
FIELD WIRING LOW VOLTAGE HIGH VOLTAGE

10456230