Senville 18,000 BTU Floor Mounted Mini Split Heat Pump Instruction Manual
Safety Precautions
- Installing, starting up, and servicing air-conditioning equipment can be hazardous due to system pressures, electrical components, and equipment location (roofs, elevated structures, etc.).
- Only trained, qualified installers and service mechanics should install, start-up, and serve this equipment.
- When working on the equipment, observe precautions in the literature and on tags, stickers, and labels attached to the equipment.
- Follow all safety codes. Wear safety glasses and work gloves. Keep quenching cloth and fire extinguisher nearby when brazing. Use care in handling, rigging, and setting bulky equipment.
- Read these instructions thoroughly and follow all warnings or cautions included in literature and attached to the unit. Consult local building codes and National Electrical Code for special requirements.
Indoor Unit
-
A location which can bear the weight of indoor unit.
-
Do not install indoor units near a direct source of heat such as direct sunlight or a heating appliance.
-
A location which provides appropriate clearances as below figure.
Outdoor Unit -
A location which is convenient to installation and not exposed to strong wind. If unit is exposed to strong winds it is recommended that a wind baffle be used.
-
A location which can bear the weight of outdoor unit and where the outdoor unit can be mounted in a level position.
-
A location which provides appropriate clearances as below figure.
-
Do not install the indoor or outdoor units in a location with special environmental conditions.
ttff i·Hl’®iM·i11:\i1:f-i·)1,:i9:HM:b.- The mounting dimensions vary among
different outdoor units.
The fixing bolt head diameter should be more than 10mm.
Indoor Unit Mounting Plate Dimensions
The mounting plate will look like one of the following depending on the unit size. The holes for fixing anchors should be 5mnV0.2in. (Unit:mm/inch)
Piping Work
Connective pipe length will affect the capacity and energy efficiency of the
unit.
The nominal efficiency is tested based on the pipe length of 5 m
- Please use tools for R41 0A system.
Align the Center to lighten the flare nut and finish connection using two wrenches.
Tightening torque for flaring connection is as below.
Wiring Work
- A main switch and circuit breaker or fuse must be installed, the capacity should be above 1.5 times of maximum current in circuit.
- An individual branch circuit and single socket used only for this appliance must be available.
- The indoor power cord type should be H05VV-F or H05V2V2-F.
- The outdoor power cord and interconnecting cable type should be H07RN-F.
- Wire cross section is depending on the rated current which is indicated on the nameplate.
Suggest Minimum Wire Size ( AWG: American Wire Gage) :
Appliance Amps | AWG Wire Size |
---|
10
| 18
13
| 16
18
| 14
25| 12
30| 10
Indoor Wire Connection
- Lift the indoor unit front panel.
- Remove the indoor unit electrical cover and cord clamp by loosening the screws.
- Pass the connecting wires from the back of indoor unit and connect to the indoor terminal block.
Outdoor Wire Connection
- Remove the electrical cover and cord clamp by loosening the screws.
- Connect wires to the outdoor terminal block by same sequence to indoor unit.