DC2DC Plus Battery Charger
Product Information: Enerdrive DC2DC+ Battery Charger
Thank you for purchasing the Enerdrive DC2DC+ Battery Charger.
This product is designed to provide a multistage, multi-input
battery charger for various types of batteries in your home, boat,
caravan, 4WD, or commercial vehicle. The charger has a
state-of-the-art, easy-to-use design that offers reliable
service.
Product Numbers
- Enerdrive 12V 40+ DC2DC Charger
Service Contact Information
If you have any questions or need assistance, please contact our
service team:
- Phone: [Service Phone Number]
- Email: [Service Email Address]
Disclaimer
Please read and follow the instructions and precautions
carefully to ensure safe and effective use of the battery
charger.
Important Note
Please keep this manual for future reference.
Table of Contents
- Introduction
- Warnings
- Product Description
- Understanding the Unit
- Installing the Charger
- Connecting the Charger
- Unit Operation
- Specifications
- Warranty
Product Usage Instructions
Step 1: Connect Auxiliary Battery to DC2DC output via a 60 amp
fuse
Make sure to connect the auxiliary battery to the DC2DC output
using a 60 amp fuse.
Step 2: Connect Start Battery to DC2DC Input via 70 amp
fuse
Connect the start battery to the DC2DC input using a 70 amp
fuse.
Step 3: Connect Solar Panels to DC2DC Solar Input
Connect your solar panels to the DC2DC solar input.
Step 4: Connect switched ignition source to ignition input
(smart alternator vehicles)
If you have a smart alternator vehicle, connect the switched
ignition source to the ignition input.
Step 5: Start vehicle – check DC2DC is working
Start your vehicle and check if the DC2DC charger is working
properly.
Step 6: DC2DC will go to sleep when not charging after 3-6
minutes
Note that the DC2DC charger will go to sleep mode after 3-6
minutes of not charging.
*For detailed technical information, please refer to the
manual.
If you need further assistance or want to join our tech support
community group, Enerdrive Unplugged, please visit our website or
contact our service team.
Masterclass Videos
- How to Install a DC2DC Charger
- How to install a DC2DC Charger (Smart Alternators)
ENERDRIVE 12V 40+ DC2DC CHARGER
QUICK START GUIDE
Step 1.
Connect Auxiliary Battery to DC2DC output via a 60 amp fuse
Step 2.
Connect Start Battery to DC2DC Input via 70 amp fuse
Step 3.
Connect Solar Panels to DC2DC Solar Input
Step 4.
Connect switched ignition source to ignition input (smart alternator vehicles)
Step 5.
Start vehicle – check DC2DC is working
Step 6.
DC2DC will go to sleep when not charging after 3-6 minutes
*For detailed technical information, please refer to the manual.
Join our tech support community group, Enerdrive Unplugged
Masterclass Video: How to Install a DC2DC Charger
Masterclass Video: How to install a DC2DC Charger
(Smart Alternators)
Page 1
Enerdrive DC2DC+ Battery Charger Owners Manual (Rev. 1.2)
Table of Contents
1. Introduction
4
Please Keep This Manual For Future Reference
4
Disclaimer
4
Important Note
4
Product Numbers
4
Service Contact Information
4
Notice of Copyright
5
2. Warnings
6
Please read and follow the instructions and precautions carefully.
6
3. PRODUCT DESCRIPTION
8
4. UNDERSTANDING THE UNIT
9
Multistage Charging Process – GEL, AGM, Flooded & Program Modes
9
Lithium Charging Process
9
Smart Charging Feature
10
Charger algorithm
10
Lithium Battery charging algorithm
11
Battery Charger Voltage
11
Battery Bank Size Recommendation
12
EN3DC40+ (Current Settings):
12
5. INSTALLING THE CHARGER
13
Mounting The Charger
14
6. CONNECTING THE CHARGER
15
Chassis Grounding Connection
15
DC Output Wiring
15
DC2DC+ Battery Charger Connections
16
Recommended Cable Length, Size and Fuse Protection.
17
Standard Temperature Sensor Connection
18
Battery Wiring (Towing Applications):
19
Battery Wiring (Vehicle & Marine Applications):
20
7. UNIT OPERATION
21
Understanding The Charging Mechanism
21
Operating from a Start Battery / Alternator (CH3)
21
Page 2
Enerdrive DC2DC+ Battery Charger Owners Manual (Rev. 1.2)
DC Input (CH2 Solar / PV):
23
Maximising your Solar Harvest using the DC2DC+
24
Understanding the Display & Function Keys during normal operation
25
Understanding The Function Key MENU’,
SET’ And `SEL’ During Charger Setting
26
Digital Display:
26
Button Functions:
27
Automatic Override Functions:
28
Programming Your Charger
28
Understanding the Two-Stage (Mode 2) Charging
28
Understanding The Three-Stage (Mode 3) Charging
28
Understanding The Battery Temperature Functions
28
Battery Temperature Compensation:
29
Battery Temperature Sensor (BTS) Voltage Adjustment:
29
Procedure To Set Or View Charger Setting
29
Procedure To Equalise Flooded Batteries
30
Use the following procedure to setup the charger for battery equalisation.
30
Understanding The Protection Features
31
Charging A Flat Battery
31
Understanding The Display Codes
31
8. SPECIFICATIONS
34
9. WARRANTY
35
5 Year Warranty
35
Page 3
Enerdrive DC2DC+ Battery Charger Owners Manual (Rev. 1.2)
1. INTRODUCTION
Thank you for purchasing the Enerdrive DC2DC+ Battery Charger. With our state
of the art, easy to use design, this product will o er you reliable service
for providing a multistage, multi-input battery charger to charge the di erent
types of batteries you have installed in either your home, boat, caravan, 4WD
or commercial vehicle. This manual will explain how to use this unit safely
and e ectively.
Please Keep This Manual For Future Reference
For safe and optimum performance, the Enerdrive DC2DC+ Battery Charger must be
used properly. Carefully read and follow all instructions and guidelines in
this manual and give special attention to the CAUTION and WARNING statements.
Disclaimer
While every precaution has been taken to ensure the accuracy of the contents
of this guide, Enerdrive assumes no responsibility for errors or omissions.
Note the speci cations and product functionality may change without notice.
Important Note
Please be sure to read the entire manual before using your Enerdrive DC2DC+
Battery Charger. Misuse may result in damage to the unit and/or cause harm or
serious injury. Read manual in its entirety before using the unit and save
manual for future reference.
Product Numbers
DC2DC+ Battery Charger Series
Product Number
Product Description
EN3DC40+
DC2DC+ Battery Charger 12V / 40+Amp
*DC2DC+ Battery Charger Owners Manual Rev. 1.00. This user manual is applicable to DC2DC+ models sold after July 2023 only.
Service Contact Information
Dometic Power & Control (Enerdrive) Pty Ltd
P.O. Box 9159, Wynnum Plaza, Queensland, Australia 4178 Ph: 1300 851 535 /
Fax: 07 3390 6911 Email: support@enerdrive.com.au Web: www.enerdrive.com.au
Page 4
Enerdrive DC2DC+ Battery Charger Owners Manual (Rev. 1.2)
Notice of Copyright
Enerdrive DC2DC+ Battery Charger owner’s manual © 2023 Enerdrive. All rights
reserved. No part of this document may be reproduced in any form or disclosed
to third parties without the express written permission of Dometic Power &
Control (Enerdrive) Pty Ltd. Enerdrive reserves the right to revise this
document and to periodically make changes to the content hereof without
obligation or organization of such revisions or changes, unless required to do
so by prior arrangement.
Exclusions For Documentation And Product Usage
Unless speci cally agreed to in writing, Dometic Power & Control (Enerdrive)
Pty Ltd; makes no warranty as to the accuracy, suffciency or suitability of
any technical or other information provided in its manuals or other
documentation.
Assumes no responsibility or liability for losses, damages, costs or expenses,
whether special, direct, indirect, consequential or incidental, which might
arise out of the use of such information. The use of any such information will
be entirely at the user’s risk.
Reminds you that if this manual is in any language other than English although
steps have been taken to maintain the accuracy of the translation, the
accuracy cannot be guaranteed
Makes no warranty, either expressed or implied, including but not limited to
any implied warranties of merchantability or tness for a particular purpose,
regarding these Enerdrive products and makes such Enerdrive products available
solely on an “as is” basis.
Shall in no event be liable to anyone for special, collateral, incidental, or
consequential damages in connection with or arising out of purchase or use of
these Enerdrive products. The sole and exclusive liability to Enerdrive,
regardless of the form of action, shall not exceed the purchase price of the
Enerdrive products described here in.
Page 5
Enerdrive DC2DC+ Battery Charger Owners Manual (Rev. 1.2)
2. WARNINGS
Please read and follow the instructions and precautions carefully.
This section contains important safety information for the Enerdrive DC2DC+
Battery Charger. Each time, before using the Enerdrive DC2DC+ Battery Charger.
READ ALL instructions and cautionary markings on or provided with the DC2DC+
Battery Charger, and all appropriate sections of this guide.
CAUTION
This unit is intended for indoor use ONLY. It is not suitable for installation
in an under bonnet vehicle application and such application will void
warranty. Battery Charger contains no user serviceable parts. See Warranty
section for how to handle product issues. Do not install the Enerdrive DC2DC+
Battery charger in any vehicle engine bay or con ned area where heat build up
may occur. Avoid moisture ingress. Never expose the unit to snow, water, etc..
WARNING: Shock Hazard.
Keep Away From Children!
WARNING: Fire &/or Chemical Burn Hazard!
When charging batteries they can release explosive and corrosive gasses /
chemicals. Please wear safety glasses and protective clothing including gloves
when working around batteries
LIMITATIONS OF USE
Do not use in connection with life support systems or other medical equipment
or devices. The charger is not to be used by persons with reduced physical or
mental capabilities or lack of knowledge and experience. Not to be operated or
used by children.
Page 6
Enerdrive DC2DC+ Battery Charger Owners Manual (Rev. 1.2)
WARNING
Explosion Hazard!
DO NOT use the Enerdrive DC2DC+ Battery Charger in the vicinity of ammable
fumes or gases (such as gas bottles). AVOID covering the ventilation openings.
Always operate unit in an open and well ventilated area. Prolonged contact to
high heat or freezing temperatures will decrease the working life of the unit.
WARNING
Failure To Follow These Instructions May Result In Death Or Serious Injury!
When working with electrical equipment or lead acid batteries, have someone
nearby in case of an emergency. Study and follow all the battery
manufacturer’s speci c precautions when installing, using and servicing the
battery connected to the charger. Wear eye protection and gloves. Avoid
touching your eyes while using this unit. Keep fresh water and soap on hand in
the event battery acid comes in contact with eyes. If this occurs, cleanse
right away with soap and water for a minimum of 15 minutes and seek medical
attention. Batteries produce explosive gases. DO NOT smoke or have an open
spark or re near the system. Keep unit away from moist or damp areas. Avoid
dropping any metal tool or object on the battery. Doing so could create a
spark or short circuit which goes through the battery or another electrical
tool that may create an explosion.
Page 7
Enerdrive DC2DC+ Battery Charger Owners Manual (Rev. 1.2)
3. PRODUCT DESCRIPTION
The Enerdrive DC2DC+ Battery Charger is a multistage, multi-input battery
charger to charge di erent types of batteries commonly installed in either
boat’s, caravan’s, 4WD’s or commercial vehicle’s.
Enerdrive’s ePOWER DC2DC+ Battery Charger package includes the following
items;
1 x DC2DC+ Battery Charger
1 x Battery Temperature Sensor 7.5 Meter Cable)
1 x Owner’s manual
Page 8
Enerdrive DC2DC+ Battery Charger Owners Manual (Rev. 1.2)
4. UNDERSTANDING THE UNIT
The Enerdrive DC2DC+ Battery Charger is a fully automatic multistage, multi
input battery charger with the ability to charge from either an alternator
linked to a battery; or via solar power with the in built Maximum Power Point
Tracking (MPPT) Solar Controller. With two inputs available, the house battery
will be charged from either the engine while underway, or via the solar panels
when stationary. The process to choose either engine or solar is fully
automatic and both functions are controlled from within the unit itself
without the need for external relays.
During normal operation the DC2DC+ Battery Charger will do a full charge cycle
to float stage on the house battery bank with ability to choose either GEL,
AGM, Flooded, Custom Programmable or Lithium. Once oat stage is reached the
charger transitions to a power supply mode to support on-board DC loads.
Multistage Charging Process – GEL, AGM, Flooded & Program Modes
The DC2DC+ Battery Charger is a fully automatic, set and forget charger. It is
designed to quickly and accurately recharge your deep cycle batteries
utilising charger algorithms that help to maximise the life of your
specialised deep cycle batteries. The DC2DC+ Battery Charger features
multistage smart charging technology that enables the charger to be connected
to your battery banks permanently. With the input of multiple sources, you can
be assured of charging your batteries whenever underway; or when the sun is
shining on your solar array. As dictated by battery manufacturer’s
recommendations, deep cycle batteries require a multistage charge sequence for
perfect, fast and accurate charging. The Enerdrive DC2DC+ smart charger
delivers three primary charge stages. Stage 1 Bulk or Boost charge; The
battery is charged up to the full rated output current of the charger until
the battery reaches its nal charging voltage, known as its absorption voltage.
In this step, around 80% of the battery is recovered as fast as possible.
Stage 2 Absorption Charge; With the charger voltage held steady, the
remaining 20% is replaced with the charger allowing the current to taper o as
the battery approaches full charge. Stage 3 Float; Finally, in the oat stage
the charger voltage is lowered and held at a constant and safe predetermined
level. This prevents the battery from being overcharged, yet allows the
charger to supply enough current to make up for the self-discharge losses of
the battery, while supporting additional loads connected to the battery (such
as DC lighting and refrigerators). This stage allows for the charger to be
used as a DC power supply.
Lithium Charging Process
The DC2DC+ charger has a specic charging profile for Lithium batteries. It has
its own charging voltage and current settings that needs to be set by the
user. It also requires the user to set the charger termination current (“L”
setting). Once the user de ned charge voltage is reached, the charger will
start reducing the current output and the charging process will terminate when
the charging current drops to the set termination current. This can take
anywhere between 3 to 15 minutes. The unit will then act as a power supply to
support additional loads connected to the battery while the DC2DC+ is powered
from either the vehicle or solar inputs. A Bulk re-start will occur when
battery voltage drops below 13.3V DC.
Page 9
Enerdrive DC2DC+ Battery Charger Owners Manual (Rev. 1.2)
Smart Charging Feature
The DC2DC+ Battery Charger will regulate its output based on the loads
connected to your battery banks. This function is important to maintain the
life of your battery banks as some battery chargers mistake loads for
discharge and continue to keep the batteries in the bulk or absorption stage
for extended periods of time, which will damage the battery bank. The DC2DC+
Battery Charger has two methods of load based regulation to ensure your
battery charger transitions to float when it should do so.
Charger Algorithm
Battery Charging Curve For GEL, AGM, Flooded & Program Batteries:
CHARGE CURRENT
V out V abs for 1 min
V out V abs for 1 min
L out < L setting for 1 min
(Battery
If V out < 12.5 Vdc recharge in Bulk
for 15 min
mode)
CC
BULK
ABS
CV ABS
CV ABS timeout 5 hr Total ABS timeout 8 hr
Battery Charging Curve (Current)
FLOAT
BULK
TIME
Battery Charging Curve (Voltage)
Page 10
Enerdrive DC2DC+ Battery Charger Owners Manual (Rev. 1.2)
Lithium Battery Charging Algorithm
Battery Current
Battery Voltage
Bulk
Power Supply Mode Maint. Power Supply Mode
14.4V
14.2V
14.0V
13.8V
13.6V
13.4V
13.2V
13.0V 12.8V
Time out 8 hrs max
Time out 7 days
Diagram does not illustrate our current set points.
Return to Bulk
13.3VDC triggers Bulk Restart
Note: Actual voltages depend on chosen algorithm.
Battery Charger Voltage
Battery Type GEL AGM Flooded
Lithium
Program (Custom Settings)
Absorption 14.4 V 14.6 V 14.4 V
13.9 V-14.6V (0.1V Step) (see Note2)
Float (See Note 3) 13.7 V 13.6 V 13.3 V
13.5V-14.2V (0.1V Step)
13.8V-14.8 (0.1V Step) 13.0V-13.8 (0.1V Step)
Equalisation N.A. N.A.
15.5 V (See Note1) N.A
N.A
- For ConcordeTM branded batteries (lifeline, sun xtender) use ooded setting and consult battery supplier for equalisation recommendations.
Note 1: Equalisation setting can only be used on ooded battery type selection only. See more details on Procedure to Equalise the Flooded Battery.
Note 2: Charger will terminate charging when charging current drops to below the set charger termination value.
Note 3: Charger is acting as a power supply with selected constant output voltage and preset maximum output current.
Page 11
Enerdrive DC2DC+ Battery Charger Owners Manual (Rev. 1.2)
NOTE: The equalisation function although included in the DC2DC+ will rarely be used. To activate, the battery bank must be in float, and manually activated. A typical drive will not be long enough for the DC2DC function to complete the process. The MPPT Solar function may provide enough time for Equalisation, but the best recommendation will be an AC powered battery charger.
Battery Bank Size Recommendation
The battery charging current rating is based on the battery size. The battery
bank should meet the minimum Ah rating as shown. If a smaller size battery
bank is used, set the current rating to a lower value to match with the
battery bank size. Normally, the minimum battery bank capacity is based on a
C5 rating of the battery for charging.
Current Setting Battery Capacity
5A Min 25Ah
EN3DC40+
10A
20A
30A
40A
50A
Min 50Ah Min 100Ah Min 150Ah Min 200Ah Min 250Ah
EN3DC40+ (Current Settings):
Bulk (“h” Setting)
ABS Float (“L” Setting)
Bulk (“h” Setting)
ABS Float (“L” Setting)
EN3DC40+ Available Current Settings
5A
10A
15A
20A
1A/1.5A/2A 1A/1.5A/2A 1A/1.5A/3A 2A/3A/4A
30A
35A
40A
45A
3A/4A/6A 3A/5A/7A
4A/6A/8A
4A/6A/9A
Use the above table to set the Bulk and its related Absorption (ABS) to Float Charge Current.
25A 2A/4A/5A
50A 5A/7A/10A
IMPORTANT NOTE: If in doubt of the “L” setting, use the highest available current setting for battery protection.
Page 12
Enerdrive DC2DC+ Battery Charger Owners Manual (Rev. 1.2)
INSTALLING THE CHARGER 5.
WARNING
Enerdrive recommends that all wiring be done by a skilled technician to ensure
adherence to the best practice standards for on-board DC electrical
installations. Failure to follow these instructions can damage the unit and
could also result in personal injury or loss of life.
CAUTION
Before Installing The Unit Consider The Following:
This unit is designed ONLY for internal mounting and should be used or stored
in an indoor area away from direct sunlight, heat, moisture or conductive
contaminants. DO NOT INSTALL IN VEHICLE ENGINE BAY This is an electronic
device cooled by a fan, and will prematurely fail if installed in corrosive /
moisture rich environments. When placing the unit, allow a minimum of 75mm of
space around the unit for optimal ventilation.
NOTE
The Enerdrive DC2DC+ Battery Charger is designed to be permanently mounted.
Page 13
Enerdrive DC2DC+ Battery Charger Owners Manual (Rev. 1.2)
Mounting The Charger
· Choose an appropriate mounting location. · For installing in an indoor
location, the unit should be mounted vertically (with the
battery terminals facing downwards). This provides the best thermal
performance and drip protection. The unit should NOT be mounted upside down. ·
For installing in a boat or marine environment, the unit should only be
mounted vertically (Battery Terminals facing downwards only) to provide
adequate drip protection. · Use the base of the charger as a mounting template
to mark the positions of the xing screws. · Drill the 4 xing holes and place
the Charger in position and fasten the unit to the mounting surface.
55mm
119mm
Page 14
160mm Enerdrive DC2DC+ Battery Charger Owners Manual (Rev. 1.2)
6. CONNECTING THE CHARGER
Chassis Grounding Connection
BEST PRACTICE
This Charger SHOULD BE CORRECTLY GROUNDED.
The unit chassis has a stud point on it for grounding. Connect the unit’s
chassis ground to the common ground point through the ground stud located near
one of the unit mounting slots. (Battery DC negative is the best ground
reference point in your installation) .
DC Output Wiring
WARNING: Correct DC Wiring Is Required
The DC wiring used must be of appropriate size. An individual fuse or breaker
is required to be installed within 20cm of the both the start battery and
house battery bank. A DC isolator or fuse is also recommended for the solar
input. All devices must be rated for DC voltage and current. The solar input
fuse or breaker must be able to withstand the short circuit current rating
stated on the solar panel array. All wiring must conform or exceed the
recommendations stated in this manual (page 17). This is a Dual Input device.
Di erent cable sizes are required for the alternator input, solar array input
and the DC2DC+ charger to battery connection.
Page 15
Enerdrive DC2DC+ Battery Charger Owners Manual (Rev. 1.2)
DC2DC+ Battery Charger Connections
Battery Temperature Sensor Port
Unit Ground
IGNITION SENSE BATTERY INPUT BATTERY INPUT SOLAR INPUT SOLAR INPUT BATTERY OUTPUT BATTERY OUTPUT TERMINAL
CH3
Start Battery
CH2
Solar Array
CH1
House Battery
Page 16
Enerdrive DC2DC+ Battery Charger Owners Manual (Rev. 1.2)
Recommended Cable Length, Size and Fuse Protection.
DC2DC Connection Inputs
DC2DC set to =<30A Output
From Alternator Battery
Primary Battery Connection (2)
Require Length & Battery Cable Size
2 Meters to 5 Meters (2)
6-16mm2 @ 12vdc / 4-8mm2 @ 24vdc
Up to 10 Meters (2)
16-35mm2 @ 12vdc / 8-16mm2 @ 24vdc
Greater than 10 Meters
Not Recommended
16mm2
Not Recommended Not Recommended
DC2DC Connection Inputs
DC2DC set to =<40A Output
From Alternator Battery
Primary Battery Connection (2)
Require Length & Battery Cable Size
2 Meters to 5 Meters (2)
10-25mm2 @ 12vdc / 10mm2 @ 24vdc
Up to 10 Meters (2)
25-50mm2 @ 12vdc / 25mm2 @ 24vdc
Greater than 10 Meters
Not Recommended
16-25mm2
Not Recommended Not Recommended
DC2DC Connection Inputs
DC2DC set to 50A Output
From Alternator Battery
Primary Battery Connection (2)
Require Length & Battery Cable Size
2 Meters to 5 Meters (2)
16-25mm2 @ 12vdc / 8-10mm2 @ 24vdc
Up to 10 Meters (2)
35-50mm2 @ 12vdc / 16-25mm2 @ 24vdc
Greater than 10 Meters
Not Recommended
16-25mm2
Not Recommended Not Recommended
Note: Cable size quoted is one way from battery to device, however suggested cable size is calculated with return run. 1) Note: If solar panels are wired in Series (increased voltage), then typically 1 x 4mm2 cable run per series string is suitable. 2) Based on 3% voltage drop.
Page 17
Enerdrive DC2DC+ Battery Charger Owners Manual (Rev. 1.2)
From Alternator Battery
From Solar Panels Primary Battery Connection
Recommended Fuse Protection
70amp Fuse or Circuit Breaker no greater than 20cm from source battery.
PLEASE NOTE: Automatic re-settable circuit breakers are NOT recommended.
Fusing recommended no greater than 20cm from input to DC2DC+ Charger.
Typically 15amps per solar panel (consult your panel speci cations for further
details).
60amp Fuse or Circuit Breaker.
Standard Temperature Sensor Connection
· To install the temperature sensor, simply connect the RJ12 plug from the
sensor to the RJ12 Temperature Sensor Port located next to the Remote Port.
· On the temperature sensor end, simply connect the ring terminals to the
negative terminal of the main house battery bank.
PLEASE NOTE: For lithium installations, the standard supplied temperature sensor is not required to be installed for these applications.
Page 18
Enerdrive DC2DC+ Battery Charger Owners Manual (Rev. 1.2)
Battery Wiring (Towing Applications):
For Towed Applications i.e. Caravans, Camper Trailers
Please NOTE
The negative cable from the start battery must be carried to the DC2DC input
terminal for correct operation in a towed application.
(Optional Ignition – On) VSO
(Voltage Sense Override)
Fuse Size 1A
Fuse / Breaker 12V – 70A 24V – 40A
Anderson Plug (Optional) Fuse / Breaker
Please NOTE
Start / Vehicle Battery 12V or 24V
Vehicles with a Smart alternator, the Negative cable must be
connected to the vehicle side of the Battery Sense Module.
Smart alternator battery sense
module.
MPPT Solar Panel Input Max: 500w / 45VOC
(For xed or portable panels)
Temp Sensor Cable (Included)
Fuse / Breaker 60A
12V House Battery Bank
POSITIVE WIRE NEGATIVE WIRE TEMPERATURE SENSOR CABLE (INCLUDED)
This diagram is for a reference only. No cables, fuse/breakers, batteries or solar panels are supplied with this unit. Local rules and regulations should be followed when installing this unit.
Page 19
Enerdrive DC2DC+ Battery Charger Owners Manual (Rev. 1.2)
Battery Wiring (Vehicle & Marine Applications):
For In Vehicle & Marine Installation. i.e. Motorhomes, 4WD’s & Trucks.
Please NOTE
Vehicles with a Smart alternator, the Negative cable must be connected to the
vehicle side of
the Battery Sense Module.
(Optional Ignition – On) VSO
(Voltage Sense Override)
Fuse Size 1A
Fuse / Breaker 12V – 70A 24V – 40A
Smart alternator battery sense
module.
Fuse / Breaker
Temp Sensor Cable (Included)
Fuse / Breaker 60A
Start / Vehicle Battery 12V or 24V
MPPT Solar Panel Input Max: 45VOC
(For xed or portable panels)
12V House Battery Bank
POSITIVE WIRE
NEGATIVE WIRE
TEMPERATURE SENSOR CABLE (INCLUDED)
This diagram is for a reference only. No cables, fuse/breakers, batteries or solar panels are supplied with this unit. Local rules and regulations should be followed when installing this unit.
Page 20
Enerdrive DC2DC+ Battery Charger Owners Manual (Rev. 1.2)
7. UNIT OPERATION
Understanding The Charging Mechanism
Note 1: The Charger is powered by the battery connected to DC Output (CH1) and
also supplied by CH2 or CH3 if available. The display will turn o to save
power when Input Channel CH2 and CH3 are out of operating range.
Operating from a Start Battery / Alternator (CH3)
Normal Operation:
Input Voltage Range Normal Start-Up Voltage (Note A) Normal Under Voltage
Recovery Voltage (Note A)
Ignition Sense Terminal
Low Start-Up Voltage (using Ignition Sense Terminal or using Manual Over-ride
setting) (Note B) Low Under Voltage Recovery Voltage (Note B) De-Rated Voltage
(with load) (Note C) Under Voltage Shutdown (with load) Over Voltage Shutdown
Over Voltage Recovery Input Battery System Reset Voltage (NoteD) Maximum Input
Current – EN3DC40+
Input Battery / Source
12V Input
24V Input
10.5V 16.0V
21.0 32.0V
13.2V
26.4V
12.8V
25.6V
Ignition Sense Terminal must see a minimum of 10.5V to trigger low
voltage “Priority Mode”.
12.3V
24.6V
12.0V 11.5V 10.5V 16.0V 15.5V < 7V 50A
24.0V 23.0V 21.0V 32.0V 31.0V < 7V 50A
Note A:
When the battery is charging through CH3 with normal operation (not through
Ignition or override setting), the charger will charge for 3 minutes, it will
then rest for 5 seconds to verify the Input voltage.
During the 5 seconds rest period, if the measured voltage is >12.8Vdc on a 12V
System (>25.6Vdc on a 24V system), the unit will continue the charging cycle
through CH3.
If the measured voltage on CH3 is <12.8Vdc (<25.6Vdc on a 24V system), the
unit will disconnect from the vehicle source and switch back to charge from
CH2 (solar if installed) until the CH3 voltage returns to >13.2Vdc on a 12V
System (>26.4V on a 24V system).
Also, during the 3 minutes charging process, if the measured terminal voltage
drops below <11.5V for a 12V system, (<23V for a 24V system), the charger will
start to derate the output
Page 21
Enerdrive DC2DC+ Battery Charger Owners Manual (Rev. 1.2)
current. This function is used to compensate for the use of long or thin wire
between the Input Battery System and the unit input terminals. If the input
voltage continues to drop below the <10.5V for a 12V system (<21V for a 24V
system), the charging process will terminate and the unit will switch back to
charge from CH2 (solar if installed) if installed. It will only switch back to
CH3 if the CH3 voltage is >13.2V on a 12V system (>26.4V on a 24V system.
Note B:
When the unit has activated the battery charging process using the ignition
sense terminal (Priority Mode) or using the Manual Override through the unit
setting, the input voltage speci cation is reduced. It has the same charging
process but with a Low Start-Up Voltage set to >12.3Vdc 12V system (>24.6V on
a 24V system). This feature is designed to be used for vehicles tted with
“Smart Alternators”.
If the measured voltage on CH3 is <12.0 Vdc (<24Vdc on a 24V system), the unit
will disconnect from the vehicle source and switch back to charge from CH2
(solar if installed) until the CH3 voltage returns to >12.3Vdc on a 12V System
(>24.6V on a 24V system).
The Low Under Voltage Recovery Voltage is set to > 12V (from 12.8V) on a 12V
system and > 24V (from 26.4V) on a 24V system. During the 5 second rest
period, if the input voltage returns above 12V/24V, it will continue the
charging process and if the input voltage does not return to > 12V/24V, it
will switch back to charge from the Solar – CH2 (if connected) until the Start
– CH3 input has returned to the Low Start-Up voltage of 12.3V on a 12V system
and 24.6V on a 24V system.
Note C:
During the 3 minute charging process, if the measured terminal voltage drops
below the Under Voltage de-rated limit (11.5V for a 12V system, 23V for a 24V
system), the charger will start to de-rate the charger current. This function
is used to compensate the use of long or thin cable between the Input Battery
and the unit terminals. If the voltage continues to drop to below the Under
Voltage Shutdown limit of (10.5V for a 12V system and 21V for a 24V system),
the charging process will terminate and the unit will switch back to charge
from CH2 (solar if installed). It will only switch back to CH3 if the CH3
voltage returns to 13.2V (12.3v with ignition sense connected) on a 12V system
and 26.4V (24.6V with ignition sense connected) on a 24V system.
Note D:
The CH3 DC Input (Battery Input) can accept a 12V or 24V battery with an
alternator system. When the unit is rst connected, the unit will measure the
input voltage. If the voltage is >17V, it will assume it is connected to a 24V
Input Battery/Alternator system. If the voltage detect is < 17V, it will
assume it is connected to a 12V Input Battery/Alternator system. Once
detected, it will store this into the microprocessor and it will only be
erased if the Input battery is disconnected or if the measured Input Voltage
drops to < 7Vdc.
Page 22
Enerdrive DC2DC+ Battery Charger Owners Manual (Rev. 1.2)
DC Input (CH2 Solar / PV):
PV Input Voltage Range
14.5 – 45V
PV Input Under Voltage Shutdown
< 14.5V
PV Input Under Voltage Recovery
15.0V
PV Input Over Voltage Shutdown
45V
PV Input Over Voltage Recovery
= < 44V
PV Charging Mechanism
MPPT type ( approx. 97% e ciency)
Maximum Input
500W *See Note below and “Maximising your Solar Harvest using the DC2DC+”
*Note: The recommended maximum solar wattage input for the DC2DC+ Charger is 500w. You can however “overdrive” the MPPT controller. Please note that doing this is partially an economic decision. You can install more power than the controller can use and this will contribute to better power availability. Enerdrive suggest a total maximum overdrive of 20% (total 600w). On cloudy (or intermittent sunny) days there will be little or no power shaving and the extra power will serve the battery well with more energy harvest earlier and later in the day.
Page 23
Enerdrive DC2DC+ Battery Charger Owners Manual (Rev. 1.2)
Maximising your Solar Harvest using the DC2DC+
The Solar Input on the DC2DC+ unit has a maximum rated INPUT current of
30amps. This means it is optimised for using higher voltage `grid’ type
modules for best output performance The maximum achievable output using
standard 20Voc solar modules will be approximately 35amps @ 14.4Vdc output.
Panel Array
1 1 2 2 3 3 4 4 5 5
Rated Wattage & Volts
150watt @ 20Voc 200watt @ 43Voc 150watt @ 20Voc 200watt @ 43Voc 150watt @
20Voc 200watt @ 43Voc 150watt @ 20Voc 200watt @ 43Voc 150watt @ 20Voc 200watt
@ 43Voc
Open Circuit rating
150watts 200watts 300watts 400watts 450watts 600watts 600watts 800watts
1000watts 1000watts
Estimated DC Amps Output (## See Below)
10 13 21 27 31 42 35* 47** Not Recommended Not Recommended
- Maximum achievable output on the DC2DC+ unit when using 20Voc Solar Panels will be thaeppapropxriomxaimtealyte3l5yA3m5apms.ps.
** Maximum achievable output on the DC2DC+ unit when using 43Voc Solar Panels will be theapapprporxoimximataetlyel4y74A7mampsp.s.
IMPORTANT NOTE: Estimated Amps Output is quoted based upon PERFECT Solar
conditions including Sun Angle, Panel Mounting angle and Orientation to the sun. It needs to be noted that panel performance alters dramatically between Summer and Winter periods and actual performance may be impossible to predict.
Page 24
Enerdrive DC2DC+ Battery Charger Owners Manual (Rev. 1.2)
Understanding the Display & Function Keys during normal operation
Digital Display Digital Display Info : CH1
CH2 & CH3 Fault/Warning
CH3′ Icon Flashing
CH3′ Icon Solid CH2′ Icon Flashing
CH2′ Icon Solid
Display
LCD with back lighting
Charging Status, Voltage, Current Voltage Error code E01-08, Warning A01-02
CH3 > 12.0V on a 12V Input system CH3 > 24.0V on a 24V Input system and not
charging from (alternator)
Charging from CH3 input (Start Battery / Alternator)
CH2 > 14.5V and not charging from solar array
Charging from CH2 input (solar)
· During normal operation, the display will cycle through and show CH1 battery
voltage, charging current and charging stage (bul’ Bulk stage,
Abs’
Absorption stage, Ful Float stage) alternatively. When the
MENU’ key is
pressed, it will display the other channel’s battery voltage only
· CH3 icon will ash when the input voltage is above (> 12 on a 12V system or >
24V on a 24V system and it is not the source charging the battery. It will
change to solid when it becomes the source charging the battery.
· CH2 icon will ash when the input voltage is above the Flashing Voltage (>
14.5V) and is not the source charging the battery. It will change to solid
when it becomes the source charging the battery.
· During normal operation, Every time the menu button is pressed once, the
display will scroll through and show CH1, CH2 & CH3: Voltage’ for 3 seconds
and it will return to the normal display automatically. If CH2 or CH3 is not
connected, it will show 0V.
· The display will remain ON when either one or both CH2 & CH3 inputs are
available. The display will turn OFF if CH2 or CH3 is not available.
· During equalisation operation (for ooded batteries only), the numerical
section on the display will show a ashing `eq’ indicating the equalisation
process is in progress and it will not show the battery voltage or the
charging current.
Page 25
Enerdrive DC2DC+ Battery Charger Owners Manual (Rev. 1.2)
Understanding The Function Key MENU’,
SET’ And `SEL’ During Charger Setting
CH1 – display is showing the charging battery info (charging status, voltage
and current).
CH2 or CH3 – When displayed symbol is solid this means the power is coming
from the related channel and the other channel will be ashing if it is
connected but not charging.
“V” – Display is showing the voltage
“A” – display is showing the current
“Auto” – units Silent mode is switched on
“Priority” – the units “ignition Sense” terminal is connected or the unit is
set to Manual Override mode
“Mode” – charging mode setting
“Temp” – Temperature setting
*Will only display when selected setting is active
Priority
Digital Display:
· During the charging process, the display shows CH1′ charging status, voltage and current repeatedly, and
CH2′ or CH3′ symbol is solid to indicate the active input source. If the other input channel is available and the voltage is above the
CH2 and CH3 Flashing Voltage’ the icon will be ashing.
When the menu button is pressed once, the display will change to show CH1
Voltage for 3 seconds, CH2 voltage for 3 seconds and CH3 voltage for 3
seconds. The display will then revert back to normal operation and will show
the CH1 info.
· When the Battery (CH1) is fully charged, it will show CH1′ and
FLO’,
voltage and current repeatedly on the display.
· The selected “battery type” icon is always ON at all times during the whole
charging process.
· The Priority’ Icon turns ON when the “ignition sense” terminal is connected or the unit is set to
Manual Override’ mode.
Page 26
Enerdrive DC2DC+ Battery Charger Owners Manual (Rev. 1.2)
Button Functions:
· During normal charging operation, press once to change the display to show
· CH1, CH2 and CH3 voltage.
· During normal charging operation, press and hold for more than 3 seconds to
enter Charger Function Setting Menu
· When CH2 or CH3 is not available (voltage detect is below the sense
voltage), display will turn OFF. Press once will temporary trigger on the
display and it will automatically cycle through all three channels voltage,
the software revision and then turn o .
· During the charger Setup Menu, this button is used to con rm the setting and
continue to the next menu.
· Manual Override Mode: During normal operation, when the input source is
charging from CH2, press and hold for more than 10 seconds to turn Priority
mode ON, Priority’ icon on display will turn ON. This will force the charger from being connected to CH2 and connect it to CH3 (subject to CH3 being 12.3v or 24.6V or higher). If CH3 is not connected or out of operating range, it will go back to CH2. This setting mode is used when CH2 (Solar) is available but the charging current is too small due to the availability of sunlight. Use the same procedure to turn o the
Manual Override’ mode when not required.
· Please Note: If Manual Override Mode is used and left on there is a risk of
attening the start battery. The preferred method is to use the automatic
override method by connecting the ignition source to the ignition terminal of
the DC2DC+ charger.
· With Flooded Battery Type setting, press and hold the “SET” and “SEL”
buttons together for more than 5 seconds will force the charger into Equalized
Mode and it will start equalizing the ooded battery. Please note; the battery
has to be set to Flooded’ battery type in-order to have this function activated. · During the charger Setup Menu, this button is used to change to the next available setting. ·
Silent’ mode (Fan OFF mode): During normal operation, Press and hold for
more than 10 seconds will force the fan to turn OFF. Auto’ icon will turn ON. The charger current will reduce to half of the set current. The unit will go back to normal after 12 hours and the
Auto’ icon will turn OFF.
· Note: Every time the “MENU”, “SET” and/or “SEL” buttons are pressed, the
back light will illuminate and will automatically turn o after 60 seconds.
Page 27
Enerdrive DC2DC+ Battery Charger Owners Manual (Rev. 1.2)
Automatic Override Functions:
When positive power is applied to the “Ignition Sense” terminal (do not
connect to ground), it will force the charger to connect to CH3 as long as CH3
is within the voltage range >12.3V or 24.6V on a 24v input.
Programming Your Charger
Press and hold the key for longer than 3 seconds to enter charger setting mode
and show function setting. Once new setting is done, press `MENU’ again for
longer than 3 seconds to exit the charger setting mode.
Press the key once to keep / save the chosen setting and change the display to
show the next menu to continue other settings. Note: The selected setting will
quickly ash 3 times to acknowledge the setting.
Press the key to view other available settings.
Understanding the Two-Stage (Mode 2) Charging
(Default setting is 3) The DC2DC+ can be set to act as a 2 stage charger
(Bulk/Float). Certain applications may require a 2 stage charge process and by
setting this option, the DC2DC+ unit will act accordingly to meet this
requirement. During the Bulk stage, the battery accepts the maximum constant
current from the charger. In Float stage, the charger continuously produces a
lower constant oat voltage to maintain the battery in a fully charged stage.
Understanding The Three-Stage (Mode 3) Charging
The Three-Stage Charging (Mode 3) has a Bulk/Absorption/Float sequence. During
the Bulk stage, the battery accepts the maximum constant current from the
charger. In the Absorption stage, the battery voltage is held to constant
voltage and the charging current will slowly reduce. In Float stage, the
charger continuously produces lower constant oat voltage to fully top up and
maintain the battery in a fully charged stage.
The charger will automatically restart the full charging cycle if it senses
the battery bank is discharged to lower than 12.5V for lead acid batteries and
13.3V for lithium batteries.
Understanding The Battery Temperature Functions
The Battery Temperature Sensor is included with the charger to protect your
battery and provide better charging voltage accuracy.
When the battery temperature sensor output is used, it is highly recommended
to be installed on the main battery bank at the negative terminal. The sensor
senses the battery temperature and overrides the manual temperature settings
and makes small adjustments to the charging voltage.
If using lithium batteries, leave temp set to “NOR” (Normal) and leave temp
sensor disconnected.
Page 28
Enerdrive DC2DC+ Battery Charger Owners Manual (Rev. 1.2)
Battery Temperature Compensation:
There are three manual battery temperature settings on the unit (Lo’,
nor’
and `hi’). See the table below for voltage adjustments for temperature
compensation.
Temperature Setting
Recommended Battery Temperature
Low (Lo)
< 5°C
Normal (Nor)
5°C and < 30°C
High (HI)
30°C
Battery Type
GEL, Flooded AGM
GEL, Flooded AGM
GEL, Flooded AGM
Voltage adjustment from 25°C normal setting + 0.675 V + 0.525 V 0 V 0 V – 0.27 V – 0.21 V
Battery Temperature Sensor (BTS) Voltage Adjustment:
Battery Temperature
< 25°C 25°C > 25°C
Battery Charging Voltage Adjustment from 25°C
Flooded and GEL type
AGM type
+ 0.027V / °C
+ 0.021V / °C
0V
0V
– 0.027 / °C
– 0.021 / °C
Note: The above voltage compensation will only work with the supplied Battery
Temperature Sensor tted which will override the unit temperatures’ (Lo, Nor,
Hi) setting. If using lithium batteries, leave temp setting “NOR” (Normal) and
leave temp sensor disconnected.
Procedure To Set Or View Charger Setting
Follow the procedure or sequence in Appendix A1 and A2 (see back of this
manual) to set or view the charger setting.
Page 29
Enerdrive DC2DC+ Battery Charger Owners Manual (Rev. 1.2)
Procedure To Equalise Flooded Batteries
DANGER
Explosion Hazard And Risk Of Battery Damage.
The battery generates explosive gases during equalisation. Follow all the
battery safety precautions listed in the manual. When using the equalisation
mode, the user has to be sure the battery connected to the battery charger is
a ooded battery type. Equalizing a non- ooded battery may overcharge the
battery and may cause the battery to explode.
CAUTION
Risk of battery and equipment damage.
Only Flooded lead-acid can be equalised. Consult your battery manufacturer or
read the battery manual when you try to equalise your batteries.
Disconnect any DC load connected to the battery, as during equalise mode, the
charger will produce 15.5V to the batteries. You must monitor the battery
speci c gravity throughout the equalisation process to determine the end of
the equalising cycle. Before setting the equalisation mode, please be sure the
battery is a ooded battery type. When the battery equalisation has started,
the charger will automatically fully charge the battery bank and will then
follow with 1 hour of equalisation. Check the battery electrolyte level during
the equalisation period. If necessary, re ll with distilled water only. All
cells should have similar electrolyte levels. If distilled water is added,
batteries must undergo a complete charge cycle. The charger cannot determine
when to terminate the equalisation of the battery, a one hour time-out is set
and this is used as a safety feature to require the user to continually re-
activate it as necessary after checking batteries manually.
Use the following procedure to setup the charger for battery equalisation.
With Flooded Battery Type setting, Press and Hold Button “SET” and “SEL”
together for more than 5 seconds. This will force the charger to go into to
Equalized mode and it will start equalizing the ooded battery. Please note the
battery mode setting has to be set to `Flooded’ battery type in-order to have
this function activated.
Page 30
Enerdrive DC2DC+ Battery Charger Owners Manual (Rev. 1.2)
Understanding The Protection Features
De-rating Charging Current: When the charger senses the environmental
temperature is above 50°C, the maximum charger current will de-rate to 1/2 of
the set value (A01 warning code will display). The charger will recover
automatically back to maximum charging current when the environmental
temperature drops to below 45°C.
Over Temperature Shutdown: When the charger senses the environmental
temperature is above 60°C, the charger will shutdown. It will recover
automatically when the environmental temperature drops to below 45°C.
Battery Reverse Polarity: When a reverse polarity is connected to the battery
bank, “Error Code E08” on the display will appear.
Charging A Flat Battery
The charger is designed to charge batteries with terminal voltage greater than
8.0Vdc.
Re-charging a at battery requires extreme care and attention. It is best to
re-charge using short frequent cycles rather than one long bulk cycle. Battery
damage or failure may occur if the battery is discharged so deeply.
Understanding The Display Codes
Codes will show on the display when either a function or internal warning /
fault, such as high internal temperature or DC out of range is detected and
the charger may shut down to protect itself until the fault has cleared. See
table description below for more information.
Code
Description
The charger is in Bulk Charging Mode Bulk or Boost charge; The battery is
charged at the set rated output current of the charger until the battery
reaches its nal charging voltage, known as its absorption voltage. In this
step, around 80% of the battery is recovered as fast as possible.
The Charger is in Absorption Charging Mode Absorption Charge; With the charger
voltage held steady, the remaining 20% is replaced with the charger allowing
the current to taper o as the battery approaches full charge.
The charger is in Float Charging & Power Supply Mode Float; Finally, in the
oat stage the charger voltage is lowered and held at a constant and safe
predetermined level. This prevents the battery from being overcharged, yet
allows the charger to supply enough current to make up for the self-discharge
losses of the battery, while supporting additional loads connected to the
battery (such as DC lighting and refrigerators). This stage allows for the
charger to be used as a DC power supply.
CH3 Input Voltage Check This will display for 5 seconds every 3 minutes while
charging from the alternator input (CH3) and is normal operation when the
charger is checking the under voltage recovery limit (see page 18 for
details).
Page 31
Enerdrive DC2DC+ Battery Charger Owners Manual (Rev. 1.2)
CH3 High Input Voltage Shutdown E01 This means the unit has detected the input
from the Start/Alternator has gone above 16.0V on a 12V input or 32.0V on a
24V input. This error will clear once the input has dropped below 15.5V on a
12V input or 31.0V on a 24V input.
CH3 Low Input Voltage Shutdown
This means the unit has detected that the input from the Start/Alternator has gone below 10.5V on a 12V input or
21.0V on a 24V input. This error will clear once the input has risen above 13.2V on a 12V input or 26.4V on a 24V input.
E02
If you have this error: ·Check that the voltage of your Start Battery is above 13.2V on a 12V input or 26.4V on a 24V input.
·Check that you have not left the “Priority” (Override) feature activated (Manual or Auto)
·Check that the battery cable from the Start Battery is correctly sized.
· Check you don’t have a loose terminal or blown fuse.
CH2 High Input Voltage Shutdown This means the unit has detected the input from the solar has gone above 45.0V. This error will clear once the input has dropped below 44.0V. E03 If you have this error: ·Check the speci cation of your panels the Volts Open Circuit (VOC) should not exceed 45VOC ·Make sure the solar panels have not been connected in series as this will increase the VOC voltage of the panel array. Please Note: Maximum solar VOC input must not exceed 45VOC or damage to the unit will occur.
CH2 Low Input Voltage Shutdown
This means the unit has detected the input from the Solar Array cannot sustain voltage above 14.5v.
If you have this error:
E04
·Check that you are not in a low light/non direct sunlight situation i.e. Early morning / late afternoon. ·This may also happen if your solar panels are inside in a shed with a skylight or Hi Bay Lights running or outside under
Flood Lights.
If you nd this is happening with your unit when stored, we recommend tting a DC Breaker to the output of the DC2DC+
and turning it o when the unit is not in use/storage.
CH1 High Input Voltage Shutdown
E05
This means the unit has detected that the Main/House battery has gone above 16.0V. This error will clear once the input has dropped below 15.5V.
This may be due to charging from another source. i.e. Another solar controller or AC battery charger.
Over Temperature Shutdown When the charger senses the environmental temperature above 60°C, the charger will E06 Shut down. It will recover automatically when the environmental temperature drops below 45°C. · Check to make sure the fan is working. · Make sure the unit has good ventilation.
BTS Over Temperature Shutdown
This means the units Battery Temp Sensor has detected that the batteries are too hot and has shut down to not over
charge the batteries.
E07
If this occurs, take care and check the temperature of the batteries. ·If the Batteries are Hot you may have a dropped cell or faulty battery. Stop all charging and see your local battery
shop to get your batteries tested.
·If the Batteries/Terminals are still cool or only warm, you may have a bad temp sensor. Unplug the temp sensor and
call Enerdrive.
Page 32
Enerdrive DC2DC+ Battery Charger Owners Manual (Rev. 1.2)
CH1 Output Short Circuit This means there is a Short Circuit on the DC output
to your Main/House battery. E08 If this is displayed, check the following:
·The output wires are not shorted together. ·The output wires are wired
correctly and not reverse polarity.
Over Temperature Warning When the charger’s internal temperature is > 60°C,
the unit will shut down to protect itself. The unit will return back to A01
normal charging once the internal temperature is < 58°C · Check to make sure
the fan is working. · Make sure the unit has good ventilation.
BTS High Temperature Warning When the battery temperature sensor is > 58°C,
the unit will shut down to protect the batteries. The unit will return A02
back to normal charging once the battery temperature sensor is < 56°C. ·Check
to make sure the batteries are not hot. ·Make sure the batteries have good
ventilation.
Page 33
Enerdrive DC2DC+ Battery Charger Owners Manual (Rev. 1.2)
8. SPECIFICATIONS
Output Voltage Output Current Output Power
Output Rating
12V Nominal (8.0V min) 40A ~ 50A 775W
Charger DC Output (CH1):
Selectable Battery Type
Gel, AGM, Flooded, Lithium, Program
Charger Voltage Range
13.8V 15.5V
Float Voltage Range
13.0V 13.8V
Charger Current (User Selectable)
5/10/15/20/25/30/35/40/45/50A (default 40A)
Equalize Voltage (Flooded Battery)
15.5V
Equalize Charging Current
10% of Bulk Current Setting
Charging Control
2 stage / 3 stage selectable (Default 3 stage)
DC Output Bank
Single
Current draw from CH1 when not operating
= < 50mA
Battery Temperature Setting
Low/ Normal/ High (Battery Temperature Sensor Standard)
E ciency
95%
Input Voltage Maximum Solar Input
INPUT Rating (CH2 – MPPT Solar)
14.5 – 45VOC
23V input, 500W (600W allowable) 37.5V-45V input, 750W (800W allowable)
Input Voltage
INPUT Rating (CH3 – Start/Alternator) 10.5 – 16VDC / 21 – 32VDC
Height x Width x Depth Unit Weight Shipping Weight
Dimensions
Note: Speci cations are subject to change without notice.
242mm x 172mm x 74mm 1.85 Kg 2.17 kg
Page 34
Enerdrive DC2DC+ Battery Charger Owners Manual (Rev. 1.2)
9. WARRANTY
5 Year Warranty
In the unlikely event that a technical issue arises with an Enerdrive product,
customers are encouraged to initially contact the Enerdrive Support Team on
1300 851 535 or support@enerdrive.com.au for immediate and efficient expertise
and first class product support.
IMPORTANT NOTE: CONSUMER PROTECTIONS
If you have purchased your product in Australia, you should be aware that:
This warranty is provided in addition to other rights and remedies held by a
consumer at law. Our goods come with guarantees that cannot be excluded under
the Australian Consumer Law. You are entitled to a replacement or refund for a
major failure and for compensation for any other reasonably foreseeable loss
or damage. You are also entitled to have the goods repaired or replaced if the
goods fail to be of acceptable quality and the failure does not amount to a
major failure.
Enerdrive warrants that its Products will be free from defects in materials
and workmanship (subject to limits, and in normal conditions, as described in
the complete Enerdrive Warranty Policy) for up to 5 years from the date of
purchase. For full terms, conditions and claim process, refer to the Enerdrive
website: https://enerdrive.com.au/warranty/
Page 35
Enerdrive DC2DC+ Battery Charger Owners Manual (Rev. 1.2)
Appendix A1LEAD ACID MODE VERSION: REV. 1.2
Press and hold MENU button for Display will show recent setting. 3 seconds to
enter the
Charger Function Menu
Charger con guration is a simple step by step process as shown below.
For Tech Support call Enerdrive on 1300 851 535
NOTE: The current setting below is based on the EN3DC40+ battery charger.
CH1 BATTERY TYPE
Press SEL
Display shows GEL & Bulk to change Voltage as currently set. battery type
Press SET to keep the current setting and toggle to the next menu
Press SEL
Display shows Bulk Current as currently set.
to enter high current menu
Press SET to keep the current setting and toggle to the next menu
Press SEL to change battery type Press SET to keep the current setting and
toggle to the next menu
Press SEL to change current Press SET to keep the current setting and toggle
to the next menu
Press SEL to change battery type
For Lithium and Program Battery Types refer to Appendix A2
Press SEL to return to battery type
Press SET to keep the current setting and toggle to the next menu
CH1 Battery Type Please choose the type of battery to be charged. Your choices
are GEL, AGM, Flooded, Lithium or
Custom Program
Press SEL to return to change current
CH1 Bulk Current “h” setting This setting is used to determine the maximum
output current that the charger is capable of. For currents 40A or higher,
this is achievable if the input/ output cables are large enough for the given
distance
to carry the maximum voltage.
Choose between 5 to 50A (5A increments)
Press SET to keep the current setting and toggle to the next menu
CH1 BULK CURRENT
CH1 ABSORPTION TO FLOAT CURRENT
Press SEL
Display shows Absorption to Float as currently set.
to enter low current menu
Press SET to keep the current setting and toggle to the next menu
Press SEL
Display shows Charge Mode as currently set.
to enter mode menu
Press SET to keep the current setting and toggle to the next menu
Press SEL
to change current Press SET to keep the current setting and toggle to the next
menu
CH1 Absorption to Float Current “L” Setting This setting is used to determine
when the battery is full. Once the current ow reaches this number or below,
the charger deems the battery to be full and will shift the charger to the oat
state. If running constants loads i.e. Fridge etc, set the charger to the
highest “L” number: Choose between 1 to 10A
(Subject to H setting see page 12)
Press SEL
to change mode
Press SET to keep the current setting and toggle to the next menu
Press SEL
to return to change mode Press SET to keep the current setting and toggle to
the next menu
Press SEL to return to change current Press SET to keep the current setting and toggle to the next menu
CH1 CHARGE MODE
CH1 TEMP. SELECT
Press SEL
Shows Temp Mode current setting.
to enter temp menu
Press SET to keep the current setting and return to the top level menu
Press SEL
to change temp
Press SET to keep the current setting and return to the top level menu
Press SEL
to change temp
Press SET to keep the current setting and return to the top level menu
Press SEL
to return to change temp Press SET to keep the current setting and return to
the top level menu
- Disregard the Temp Select setting if the Temperature Sensor is NOT connected.
NOTE: At any function setting, pressing the MENU button will exit the function
mode.
WARNING: FIRE HAZARD
When choosing the battery type and setting the charging parameter, please
consult the battery manufacturer on all the voltage and current settings.
Using the wrong setting to charge a battery may overcharge, damage the battery
and may cause a re.
Appendix A2 LITHIUM MODE VERSION: REV. 1.2
Continues from Appendix A1 CH1 Battery Type Menu
Charger con guration is a simple step by step process as shown below.
For Tech Support call Enerdrive on 1300 851 535
NOTE: The current setting below is based on the EN3DC40+ battery charger.
Press SEL
to change battery type Press SET to keep the current setting and toggle to the
next menu
For Program Battery Types refer to Appendix A3
Press SEL
Press SEL to change voltage
Press SEL
CH1 LITHIUM BULK VOLTAGE
to enter Voltage Menu Press SET to keep the current setting and toggle to the next menu
(13.9V to 14.6V in 0.1V steps) Press SET to keep the current setting and toggle to the next menu
to return to voltage
Press SET to keep the current setting and toggle to the next menu
CH1 LITHIUM FLOAT VOLTAGE
Press SEL
Display shows the Float voltage for Program.
to enter Voltage Menu
Press SEL to change voltage (13.0V to 13.8V in 0.1V steps)
Press SEL to return to change voltage
CH1 LITHIUM CHARGING CURRENT
Press SET to keep the current setting and toggle to the next menu
Press SEL to enter Max Current Menu Press SET to keep the current setting and
toggle to the next menu
Press SET to keep the current setting and toggle to the next menu
Press SET to keep the current setting and toggle to the next menu
Press SEL
to change current Press SET to keep the current setting and toggle to the next
menu
CH1 Bulk Current “h” setting This setting is used to determine the maximum
output current that the charger is capable of. For currents 40A or higher,
this is achievable if the input/ output cables are large enough for the given
distance
to carry the maximum voltage.
Choose between 5 to 50A (5A increments)
Press SEL to return to change current Press SET to keep the current setting and toggle to the next menu
CH1 LITHIUM BATTERY TERMINATION CURRENT
Press SEL to enter Termination Current Menu Press SET to keep the current
setting and toggle to the next menu
Press MENU to exit settings
Press SEL
to change current Press SET to keep the current setting and toggle to the next
menu
CH1 Absorption to Float Current “L” Setting This setting is used to determine
when the battery is full. Once the current ow reaches this number or below,
the charger deems the battery to be full and will shift the charger to the oat
state. If running constants loads i.e. Fridge etc, set the charger to the
highest “L” number: Choose between 1 to 10A
(Subject to H setting see page 12)
Press SEL to return to change current Press SET to keep the current setting and toggle to the next menu
NOTE: At any function setting, pressing the MENU button will exit the function
mode.
WARNING: FIRE HAZARD
When using the Lithium Battery type setting to set the battery charging
parameters, please consult the battery manufacturer on all the voltage and
current settings. Using the wrong setting to charge battery may overcharge,
damage the battery and may cause a re.
Appendix A3 PROGRAM MODE VERSION: REV. 1.2
Continues from Appendix A2 CH1 Battery Type Menu
Press SEL
to change battery type Press SET to keep the current setting and toggle to the
next menu
Back to Appendix A1 Battery Type
Charger con guration is a simple step by step process as shown below.
For Tech Support call Enerdrive on 1300 851 535
NOTE: The current setting below is based on the EN3DC40+ battery charger.
CH1 PROGRAM BULK VOLTAGE
Press SEL
Press SEL to change voltage
Press SEL
Display shows Program & Bulk Voltage as currently set.
to enter Voltage Menu
Press SET to keep the current setting and toggle to the next menu
(13.8V to 14.8V in 0.1V steps)
Press SET to keep the current setting and toggle to the next menu
Press SET to keep the current setting and toggle to the next menu
to return to change voltage Press SET to keep the current setting and toggle to the next menu
CH1 PROGRAM FLOAT VOLTAGE
Press SEL
Display shows the Float voltage for Program.
to enter Voltage Menu
Press SET to keep the current setting and toggle to the next menu
Press SEL to change voltage
(13.0V to 13.8V in 0.1V steps)
Press SET to keep the current setting and toggle to the next menu
Press SET to keep the current setting and toggle to the next menu
Press SEL
to return to change voltage Press SET to keep the current setting and toggle
to the next menu
Press SEL to return to change current
CH1 PROGRAM BULK CURRENT
CH1 PROGRAM ABSORPTION TO FLOAT
CURRENT
Press SEL
Display shows Bulk Current as to enter Max
currently set.
Current Menu
Press SET to keep the current setting and toggle to the next menu
Press SEL
Display shows Absorption to Float as currently set.
to enter Low Current Menu
Press SET to keep the current setting and toggle to the next menu
Press SEL
Display shows Charge Mode as currently set.
to enter Mode Menu
Press SET to keep the current setting and toggle to the next menu
Press SEL
to change current Press SET to keep the current setting and toggle to the next
menu
CH1 Bulk Current “h” setting This setting is used to determine the maximum
output current that the charger is capable of. For currents 40A or higher,
this is achievable if the input/ output cables are large enough for the given
distance
to carry the maximum voltage.
Choose between 5 to 50A (5A increments)
Press SEL to change current
CH1 Absorption to Float Current “L” Setting This setting is used to determine
when the battery is full. Once the current ow reaches this number or below,
the charger deems the battery to be full and will shift the charger to the oat
state. If running constants loads i.e. Fridge etc, set the charger to the
highest “L” number: Choose between 1 to 10A
(Subject to H setting see page 12)
Press SET to keep the current setting and toggle to the next menu
Press SEL to return to change current
Press SEL
to change mode
Press SET to keep the current setting and toggle to the next menu
Press SEL
to return to change mode Press SET to keep the current setting and toggle to
the next menu
Press SET to keep the current setting and toggle to the next menu
CH1 CHARGE MODE
Press MENU to exit settings
NOTE: At any function setting, pressing the MENU button will exit the function
mode.
WARNING: FIRE HAZARD
When using the Program Mode to set the battery charging parameters, please
consult the battery manufacturer on all the voltage and current settings.
Using the wrong setting to charge battery may overcharge, damage the battery
and may cause a re.
Fill in the details below for your reference and convenience.
Serial Number: Date of Purchase: Purchased From:
Page 42
Enerdrive DC2DC+ Battery Charger Owners Manual (Rev. 1.2)
Notes:
Page 43
Enerdrive DC2DC+ Battery Charger Owners Manual (Rev. 1.2)