SEALEY SAC1000B Series Belt Drive Air Compressor Instruction Manual
- June 12, 2024
- SEALEY
Table of Contents
BELT DRIVE AIR COMPRESSOR 3HP WITH CAST CYLINDERS & WHEELS
MODEL NO: SAC1503B, SAC1103B, SAC1153B, SAC1203B
Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions, and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
Refer to instruction manual Warning: Hot surface Warning: Electricity
Warning: Automatic startup Wear ear protection
SAC1103B illustrated.
(others will differ slightly)
- Direct compressed air outlet.
- Tank
- Pressure reducer.
- Belt guard.
- Compressor unit.
- Electric motor.
- Pressure switch.
- Pressure gauge.
- Pivot wheel.
- Condensate drain.
- Wheel.
- Check valve.
1. SAFETY
1.1. ELECTRICAL SAFETY
WARNING! It is the responsibility of the owner and the operator to read,
understand and comply with the following: You must check all electrical
products, before use, to ensure that they are safe. You must inspect power
cables, plugs, sockets and any other connectors for wear or damage. You must
ensure that the risk of electric shock is minimised by the installation of
appropriate safety devices.
A Residual Current Circuit Breaker (RCCB) should be incorporated in the main
distribution board. We also recommend that a Residual Current Device (RCD) is
used. It is particularly important to use an RCD with portable products that
are plugged into a supply which is not protected by an RCCB. If in any doubt
consult a qualified electrician. You must also read and understand the
following instructions concerning electrical safety.
1.1.1. The Electricity at Work Act 1989 requires that all portable
electrical appliances, if used on business premises, are tested by a qualified
electrician, using a Portable Appliance Tester (PAT), at least once a year.
1.1.2. The Health & Safety at Work Act 1974 makes owners of electrical
appliances responsible for the safe condition of those appliances and the
safety of the appliance operators. If in any doubt about electrical safety,
contact a qualified electrician.
1.1.3. Ensure that the insulation on all cables and on the appliance is safe
before connecting it to the power supply. See 1.1.1. and use a Portable
Appliance Tester.
1.1.4. Ensure that cables are always protected against short circuit and
overload.
1.1.5. Regularly inspect power supply cables and plugs for wear or damage and
check all connections to ensure that none is loose.
1.1.6. IMPORTANT: Ensure that the voltage marked on the appliance matches
the power supply to be used and that the plug is fitted with the correct fuse
– see fuse rating at right.
DO NOT pull or carry the appliance by the power cable.
DO NOT pull the plug from the socket by the cable.
DO NOT use worn or damaged cables, plugs or connectors. Immediately have
any faulty item repaired or replaced by a qualified electrician.
1.1.7. This product is fitted with a BS1363/A 3 pin plug.
If the cable or plug is damaged during use, switch the electricity supply and
remove from use.
Ensure that repairs are carried out by a qualified electrician.
Replace a damaged plug with a BS1363/A 3 pin plug. If in doubt contact a
qualified electrician.
a) Connect the GREEN/YELLOW earth wire to the earth terminal ‘E’.
b) Connect the BROWN live wire to the live terminal ‘L’.
c) Connect the BLUE neutral wire to the neutral terminal ‘N’.
Ensure that the cable outer sheath extends inside the cable restraint and that
the restraint is tight.
Sealey recommend that repairs are carried out by a qualified electrician.
IMPORTANT! The use of extension leads to connect these compressors to the
mains is not recommended as the resulting voltage drop reduces motor, and
therefore pump performance.
Replacement fuse rating: 13 AMP
- YELLOW & GREEN EARTH WIRE
- BROWN LIVE WIRE
- CABLE RESTRAINT
- BLUE NATURAL WIRE
1.2. GENERAL SAFETY
Familiarise yourself with the application and limitations of the compressor.
Ensure the compressor is in good order and condition before use. If in any
doubt DO NOT use the unit and contact your Sealey Stockist.
WARNING! Item must be serviced by an authorised agent. DO NOT tamper
with or attempt to adjust pressure switch or safety valve.
DO NOT carry out any welding operations on any pressurised part of the
vessel.
Before moving, or maintaining the compressor ensure it is unplugged from the
mains supply and that the air tank pressure has been vented.
Maintain the compressor in good condition and replace any damaged or worn
parts. Use genuine parts only. Unauthorised parts may be dangerous and will
invalidate your warranty.
Read the instructions relating to any accessory to be used with this
compressor. Ensure the safe working pressure of any air appliance used exceeds
compressors output pressure. If using a spray gun, check that the area
selected for spraying is provided with an air change system/ventilation.
Ensure the air supply valve is turned off before disconnecting the air
supply hose to move a transportable compressor use the handle only. Lift the
compressor so that the front leg gives enough clearance for manoeuvring but
maintain unit’s centre of gravity in front of the wheels. DO NOT attempt
to lift or move the compressor by any other means.
Use the compressor in a well ventilated area and ensure it is placed on a
firm surface.
Keep tools and other items away from the compressor when it is in use, and
keep area clean and clear of unnecessary items.
Ensure the air hose is not tangled, twisted or pinched.
Keep children and unauthorised persons away from the working area.
Only move the compressor by the handle (if portable).
DO NOT dis-assemble compressor for any reason. The unit must be checked
by qualified personnel only.
DO NOT use the compressor outdoors, or in damp, or wet, locations.
DO NOT operate within the vicinity of flammable liquids, gases or
solids.
DO NOT touch compressor cylinder, cylinder head or pipe from head to
tank as these may be hot.
DO NOT use this product to perform a task for which it has not been
designed.
DO NOT deface the certification plate attached to the compressor tank.
DO NOT cover the compressor or restrict air flow around the unit whilst
operating.
DANGER! DO NOT direct the output jet of air towards people or animals.
DO NOT operate the compressor without an air filter.
DO NOT allow anyone to operate the compressor unless they have received
full instructions.
WARNING! The air tank is a pressure vessel and the following safety
measures apply:
DO NOT tamper with the safety valve, DO NOT modify or alter the tank
in any way and DO NOT strap anything to the tank.
DO NOT subject the tank to impact, vibration or to heat and DO NOT
allow contact with abrasives or corrosives.
Drain condensation from tank daily and inspect inside walls for corrosion
every three months and have a detailed tank inspection carried out annually.
The tank shell must not fall below the certified thickness at any point.
WARNING! If an electrical fuse blows, ensure it is replaced with an
identical fuse type and rating.
When not in use, store the compressor carefully in a safe, dry, childproof
location.
When the compressor is not in use, it should be switched off, disconnected
from the mains supply and the air drained from the tank.
Under the PRESSURE SYSTEMS SAFETY REGULATIONS 2000 it is the
responsibility of the owner of the compressor to initiate a system of
inspection that both defines the frequency of the inspection and appoints a a
person who has specific responsibility for carrying out the inspection.
2. INTRODUCTION
Suitable for the professional workshop, these units are fitted with a genuine 3hp motor. Twin capacitors and a centrifugal switch aid trouble-free start-up on a 13A supply. Pumps feature heavy-duty full cast cylinders, capped by alloy heads for improved heat dissipation and long-life. Heavy-duty drive guards protect belt and flywheel that is designed to force air over the pump to aid cooling. Supplied with full CE certification, test certificates and operating/maintenance manual.
3. SPECIFICATION
Model:…………………………………SAC1503B ………………. SAC1103B……………….. SAC1153B ………………SAC1203B
Air Displacement cfm(L/min): …. 13.4(380) ………………….13.4(380)…………………. 13.4(380)
……………….. 13.4(380)
Fuse Rating:…………………………………..13A………………………….13A…………………………..13A ……………………….. 13A
Maximum Free Air Delivery cfm(L/min):8.8(249) ……………8.8(249)………………….. 8.8(249)
………………… 8.8(249)
Maximum Pressure: ………….145psi(10bar) ……………145psi(10bar)…………….145psi(10bar)
…………. 145psi(10bar)
Minimum Rated Supply: …………………..13A………………………….13A…………………………..13A ………………………..
13A
Motor Output: …………………………………3hp ………………………….3hp …………………………..3hp …………………………3hp
Outlet:………….Quick Release Coupling..Quick Release Coupling . 1/2”BSP Female
Tap .. 1/2”BSP Female Tap
Phase: …………………………………………..1ph ………………………….1ph …………………………..1ph …………………………1ph
Plug Type:…………………………………… 3-Pin ………………………..3-Pin ……………………….. 3-Pin ………………………
3-Pin
Power Supply Cable Length:…………..1.8m ………………………..1.8m …………………………1.8m
……………………….1.8m
Receiver Capacity: ………………………….50L ……………………….. 100L…………………………150L
……………………….200L
Size (W x D x H): …..1020 x 390 x 740mm …1010 x 470 x 860mm ….1320 x 400 x
820mm ..1440 x 440 x 865mm
Speed: ……………………………………1630rpm …………………..1630rpm ……………………1630rpm ………………… 1630rpm
Supply:………………………………… 230V/13A……………….. 230V/13A………………… 230V/13A
………………..230V/13A
4. ASSEMBLY
4.1. Remove compressor from packaging and inspect for shortages/damage. If
items are missing or damaged contact your supplier.
4.2. Save the packing material for future transportation of the compressor.
We recommend that you store the packing in a safe location, at least for the
period of the guarantee. Then, if necessary, it will be easier to send the
compressor to the service centre.
4.3. Assemble the fixed wheels / castor wheel / rubber feet to the compressor
as required (see fig.1).
4.4. Confirm that the mains voltage corresponds with the voltage shown on the
compressor data plate.
4.5. Position the compressor on a flat surface or with a maximum permissible
inclination of 10° (fig.2). Site in a well ventilated area, protected against
atmospheric pollution and not in a place subject to explosion hazard. If the
surface is inclined and smooth, check if the compressor moves whilst in
operation – if it does, secure the wheels with two wedges. If the surface is
in a raised position, make sure it cannot fall, securing it in a suitable way.
4.6. To ensure good ventilation and efficient cooling, the compressor’s belt
guard must be at least 100cm from any wall (fig.3).
Compressors with fixed feet, should not be rigidly secured to the floor. In
this case, it is advised to fit 4 anti-vibration supports (optional extra).
4.7. Take care to transport the compressor correctly, DO NOT overturn it
or lift it with hooks or ropes.
4.8. Remove the plastic transit plug from the oil filler hole (fig.4) and
replace it with the filler/breather plug. It is a push fit, ensure that it is
pushed fully home.
4.9. Before using the compressor, check the oil level by observing the sight
glass as shown in fig.4. If the oil is not up to the max mark it should be
topped up with synthetic oil suitable for temperatures ranging from -5°C to
45°C (viscosity 5W50). We DO NOT recommend using mineral oil in these
compressors. DO NOT overfill.
- Transit Plug/Oil Filter
- Oil Level
- Oil Drainer
5. OPERATION
WARNING! Ensure that you have read, understood and apply Section 1
safety instructions.
IMPORTANT! Use of extension leads to connect these compressors to the the
mains is not recommended as the resulting voltage drop reduces motor and
therefore pump performance, and could damage the compressor.
NOTE: Take care when selecting tools for use with the compressor. Air
tool manufacturers normally express the volume of air required to operate a
tool in cubic feet per minute(cfm).This refers to free air delivered by the
compressor (‘air out’) which varies according to the pressure setting.
DO NOT confuse this with the compressor displacement which is the air
taken in by the compressor (‘air in’). ‘Air out’ is always less than ‘air in’
due to losses within the compressor.
5.1. STARTING / STOPPING THE COMPRESSOR
5.1.1. To turn the compressor on use the switch on the top of the pressure
switch housing (figs.6.1 and 7.1). Turn the switch clockwise to position ‘I’
to start the compressor and anti-clockwise to position ‘O’ to stop it.
5.1.2. Check that the ON/OFF switch is in the ‘O’ position. On Models
SAC1503B and SAC1103B the regulator tap (fig.6.2) should be closed and the
output gauge (fig.6.4) must read Zero ‘0’ bar.
5.1.3. Plug into mains supply and start the compressor by turning the switch
to the ‘I’ position.
5.1.4. When starting the compressor for the first time, leave it running with
no air tools connected to the air outlet. Make sure that pressure in the tank
rises and that the compressor stops automatically when the maximum pressure
value allowed – written on the plate and shown on the gauge (figs.6.5 & 7.5) –
is achieved. The compressor will now operate automatically. The pressure
switch stops the motor when the maximum tank pressure is reached and restarts
it when the pressure falls below the minimum threshold – approx. 2 bar (29psi)
less than the maximum pressure.
5.1.5. Stop the compressor by turning the main switch to the ‘O’ position.
The compressed air inside the compressor head will flow out, making the
restart easier and preventing the motor from being damaged. DO NOT , other
than in an emergency, stop the compressor by switching off the mains socket,
or by pulling the plug out, as the pressure relief will not then operate and
motor damage may result upon restart.
5.1.6. The motor of the compressor is fitted with a thermal breaker located
in the housing on top of the motor. The manual resetting button is located in
the end of the housing as shown in fig.10A. When the breaker is tripped, wait
for a few minutes and then press the reset button.
5.1.7. On Models SAC1503B and SAC1103B, the output pressure is regulated by
the pressure regulator (fig.6.2). Turn the knob clockwise to increase pressure
and anti-clockwise to reduce it. Lock knob in position at required pressure
with locking ring. To determine the correct working pressure for any piece of
equipment check the corresponding manual. When the compressor is not being
used, set the regulated pressure to zero so as to avoid damaging the pressure
regulator.
NOTE:
a) If the motor does not cut in and out, but runs continuously when using an
air appliance, the capacity of the compressor may be too small for the
equipment or tool.
b)The gauge (figs.6.5 and 7.5) indicates the pressure inside the main tank,
NOT the pressure supplied to the air equipment.
Should the pressure in the main tank exceed the pre-set switch maximum, the
safety valve will activate.
WARNING! For this reason DO NOT tamper with, or adjust, the switch or
safety valve.
6. MAINTENANCE
6.1. In order to keep the compressor in good working condition, periodic
maintenance is essential.
IMPORTANT! Failure to carry out maintenance tasks may invalidate the
warranty on your compressor.
WARNING! Before performing any maintenance operation, switch off the
compressor, disconnect from electricity supply and release all air from the
tank (except for 6.3.a)
6.2. Operations to be carried out after the first 50 working hours:
a) Check that all bolts/nuts are tight, particularly those retaining the
crankcase and cylinder head.
b) Replace the lubricating oil – see para 6.5.
6.3. Operations to be carried out weekly:
a) Drain condensation by opening the valve located under the tank (fig.9).
Place a container under the valve and open the valve by turning anti-
clockwise.
WARNING! Take care if there is still pressure inside the cylinder as
water could flow out with considerable force. Recommended pressure 1 – 2bar
max.
b) Check oil level and, if necessary, top up.
6.4. Operations to be carried out every 50 hours (or more frequently, if the
compressor operates in a very dusty atmosphere):
a) Remove the air filter element (fig.8). Using stored air from the
compressor’s tank, clean the filter with compressed air. (Wear eye protection
and DO NOT direct air towards the body or hands). DO NOT operate the
compressor without the filter as foreign bodies or dust could seriously damage
the pump. Replace the filter element and air filter housing.
b) Check for oil leaks.
6.5. Operations to be carried out every 100 hours:
a)Check the automatic cut-out at max. pressure and the automatic cut-in at
2bar below.
6.6. Operations to be carried out every 400 hours:
a) Replace the lubricating oil. For oil specifications see 6.8.
Remove the filler/breather plug (see fig.4) then remove oil drain plug,
draining the oil into a container. Drain when the compressor is hot so that
the oil drains rapidly and completely. Incline compressor to ensure complete
drainage. Replace oil drain plug and refill through the filler/breather
aperture. DO NOT overfill. Replace plug.
WARNING! Never mix different oils and DO NOT use non-detergent/low
quality oils as the compressor may be damaged.
WARNING! Dispose of waste oil only in accordance with local authority
requirements.
b) Replace air filter. (See fig.8)
c) Check all tube fittings and electrical connections.
d) Inspect pressure tank inside and out for damage or corrosion.
6.7. Maintenance Schedule
Maintenance Operations|
Weekly
| 50hrs| 100hrs|
400 hrs
---|---|---|---|---
Drain condensation| •| | |
Check oil level| •| | |
Clean intake filter| | •| |
Check for oil leaks| | •| |
Replace oil| | | | •
Check cut-out| | | •|
General cleaning of compressor| | | •|
Replace air filter| | | | •
Check tube fittings and electrical connections| | | | •
Internal & external inspection of tank| | | | •
Check and adjust belt tension| •| | |
- Drain plug
6.8. Recommended oils
Synthetic oil suitable for temperatures ranging from -5°C to 45°C: Viscosity
5W50. We DO NOT recommend using mineral oil in these compressors.
Part No. Qty. Description
FSO1 1L x 12 Compressor oil fully synthetic
FSO1S 1L x 1 Compressor oil fully synthetic
FSO5 5L x 1 Compressor oil fully synthetic
IMPORTANT WARNING – Air contaminants taken into the compressor will
affect optimum performance. Example: Body filler dust or paint overspray will
clog the pump intake filter and may cause internal damage to pump/motor
components. Please note that any parts damaged by any type of contamination
will not be covered by warranty.
7. TROUBLE SHOOTING
Fault | Cause | Remedy |
---|---|---|
Pressure drop in the tank. | Air leaks at connections. | Run compressor to max. |
pressure, switch off.
Brush soap solution over connections and look for bubbles. Tighten connections
showing leaks. If problem persists contact Authorised Service Agent.
Pressure switch valve leaks when compressor is idle.| Non-return valve seal
defective.| Discharge all tank pressure.
Referring to fig.11, unscrew valve cap ‘A’. Clean rubber disc ‘B’ and its
seat. Refit all parts accurately.
Compressor stops and does not restart.| Power failure.
Motor failure.| Check electricity supply and fuse.
Contact Authorised Service Agent.
Compressor does not stop at max pressure.| Pressure switch fault.| Contact
Authorised Service Agent.
Compressor does not reach max pressure.| Filter clogged.
Head gasket or valve fault.| Replace filter element.
Contact Authorised Service Agent.
Compressor noisy with metallic knock.| Low oil level.
Bearing or piston damage.| Turn off and top up oil immediately.
Contact Authorised Service Agent.
ENVIRONMENT PROTECTION
Recycle unwanted materials instead of disposing of them as waste. All tools,
accessories and packaging should be sorted, taken to a recycling centre and
disposed of in a manner which is compatible with the environment. When the
product becomes completely unserviceable and requires disposal, drain any
fluids (if applicable) into approved containers and dispose of the product and
fluids according to local regulations.
WEEE REGULATIONS
Dispose of this product at the end of its working life in compliance with the
EU Directive on Waste Electrical and Electronic Equipment (WEEE). When the
product is no longer required, it must be disposed of in an environmentally
protective way. Contact your local solid waste authority for recycling
information.
Note: It is our policy to continually improve products and as such we
reserve the right to alter data, specifications and component parts without
prior notice.
Important: No Liability is accepted for incorrect use of this product.
Warranty: Guarantee is 12 months from purchase date, proof of which is
required for any claim.
Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk.
IP32 7AR
01284 757500 sales@sealey.co.uk
www.sealey.co.uk
© Jack Sealey Limited Original Language Version SAC1503B, SAC1103B, SAC1153B, SAC1203B Issue:5 (H,F) 16/05/23
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>