PRODUCT SPECIFICATIONS

  • For Cold Water Use Only
  • Temperature Range: 35-100°F (2-38°C)
  • Min.-Max. Working Pressure: 10-125 psi (0.7-8.6 bar)
  • Service Flow Rate: 2.2 gpm (8.3 Lpm)
  • Capacity: 3,000 gallons (11,355 L)

TOOLS REQUIRED FOR INSTALLATION

  • Phillips Screwdriver
  • Adjustable Wrench
  • Tape Measure
  • Pencil

BASIC INSTALLATION INSTRUCTIONS

  1. Open Carton & Inspect Parts
    Installation Parts Key| Description| Part No.
    ---|---|---
    1| QL3 Filter Head| EV927082
    2| PBS-400 Filter Cartridge| EV927086
    3| 2 Locking Washers| EV306204
    4| 2 Screws| EV306196
    5| 3/8-inch MPT x 3/8-inch FTP Elbow| EV310852
    6| (2) 3/8-inch x 1/2-inch Unions| EV312251
    7| (2) 3/8-inch x 3/8-inch Unions| EV312250
    8| Plumber Tape| EV312119
    9| Everpure Filter Timer| EV314160
  2. Verify Under-Sink Mounting Location
    Measure 20 inches from the base of the cabinet, and mark the mounting location for the top of the filter head. Make sure there is adequate space above the head to open and close the built in shut-off valve and to avoid crimping the water line tubing. Also, make sure your chosen location offers easy access for future cartridge changes.DIMENSION| Width| Mounting
    Height| Depth
    ---|---|---|---
    PBS-400| 5 inches| 20 inches| 5 inches

NOTE: The head and cartridge must be mounted in the vertical position, with the cartridge hanging down.

  1. Mount Filter Head Under SinkPENTAIR EVERPURE PBS-400 Water Filtration System - TemperatureBASIC INSTALLATION INSTRUCTIONS
    CONTINUED
    NOTE: Two sets of unions are included to connect to the 3/8inch head connections. If your existing braided tubing has 1/2-inch connections, use the 1/2-inch x 3/8-inch unions instead of the 3/8-inch x 3/8-inch unions. You will have 2 extra fittings with either
    installation. The following instructions are for a typical installation using 1/2-inch supply lines.
    A. Apply plumber tape to the small threads of one Union Fitting and screw into the open end of the Elbow. Wrap tape in direction of the threads to assure a tight fit and avoid small leaks.
    B. Apply plumber tape to the threads of the Elbow Fitting and screw into the inlet (left) side of the Filter Head. Hand tighten only.
    C. Apply plumber tape to the small threads of the second Union Fitting, and screw into the right side of the filter head in the same manner.
    D. Securely mount the filter head on the cabinet wall using the enclosed mounting screws and washers.

  2. Connect Inlet Water Supply
    E. Locate and close the cold water shut-off valve under your sink. Open cold water line of faucet to release water pressure.
    F. Unscrew and disconnect the braided tubing on top of cold water shut-off valve.
    G. Attach one end of the new braided tubing to the top of the cold water shut- off valve.
    H. Attach the other end of the new Braided Tubing to the inlet side of the filter head (Union & Elbow Fittings).

  3. Attach Filtered Water To Cold Line of Faucet
    I. Attach open end of existing Braided Tubing to Union Fitting on outlet side (right) of new Filter Head. Hand tighten to avoid damage to fittings.

  4.  Install And Flush Filter Cartridge
    J. Lift handle of the build-in shut off (QC Valve) on the Head.
    K. Hold Head firmly with one hand.
    L. Align cartridge lug with label on filter Head.
    M. Insert filter Cartridge—Push upwards.
    N. Turn it to the right—About 1⁄4 turn—Until rotation stops.
    O. Open cold water valve and check for leaks up to Inlet Elbow Fitting.
    P. Open Water Faucet (not pictured).
    Q. Lower the QC Valve Handle to flush water to the sink.
    NOTE: Flush new filter cartridges for at least 3 minutes to remove air and any loose carbon. At first the water may appear cloudy due to trapped air in the filter and tubing. If water continues to be cloudy for more that one week, please contact Pentair  Technical Support for assistance: 800-279-9404
    R. Activate Filter Timer by pinching bubble until you feel a change in resistance as the Filter timer “pops.” Within a few seconds, a thin RED line will appear in the white window showing the Timestrip ® has been activated. Peel away backing and adhere to desired location. When the white window is completely filled with RED, it is time to replace your product.PENTAIR
EVERPURE PBS-400 Water Filtration System - Temperature 1PENTAIR EVERPURE PBS-400 Water Filtration System -
Braided

HEALTH CLAIM PERFORMANCE

CLASSIFIED BY UL
This system has been tested according to NSF/ANSI 42 and 53 for the reduction of the substances listed below. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI 42 and 53.

Substance| Influent
Challenge
Concentration| Max.
Permissible
Product Water
Concentration| Reduction
Requirements| Minimum
Reduction| Average
Reduction
---|---|---|---|---|---
Standard 42—Aesthetic Effects|
Chlorine| 2.0 mg/L ± 10%| | 350%| | 98%
Particulate, Class I particles 0.5 to <1 Pm| at least 10,000
particles/mL| | 85%| | 100.%
Standard 53—Health| Effects|
Cyst| Minimum
50,000/L| 100.%| 100.%| 100.%
Lead 8.5| 0.15 mg/L ± 10%| 0.010 mg/L| 94.%| 97.%
Lead 6.5| 0.15 mg/L ± 10%| 0.010 mg/L| 99.%| 99.%

NOTE: This installation must comply with all applicable state and local regulations.
NOTE: Maximum working pressure 125 psi.
NOTE: Do no use with water that is microbiologically unsafe or unknown quality without adequate disinfection before or after the system. Systems certified for cyst reduction may be used on waters that may contain
filterable cysts.
NOTE: Testing was performed under standard laboratory conditions, actual performance may vary.
NOTE: This drinking water system must be maintained according to manufacturer’s instructions, including replacement of filter cartridges. Suggested retail $134.99.

CALIFORNIA PROPOSITION 65 WARNING

WARNING: This product contains chemicals known to the State of California to cause cancer or birth defects or other reproductive harm.
Reduces particles as small as 0.5 micron in size by mechanical means.
NSF/ANSI Standard 53 certified to reduce cysts such as Cryptosporidium and Giardia by mechanical means.

This Filter System has been Tested & Certified by  the WQA against NSF/ANSI Std. 42,53, 372 & CSA B483.1
This System has been Tested & Certified by WQA against Std. 42 & 53 as verified and substantiated by test data for the reduction of:

Std. No. 42—Aesthetic effects Std. No. 53—Health effects
Chemical Reduction Chemical Reduction Lead
Chlorine Mechanical Filtration Cyst

Taste & Odor
Mechanical Filtration
Nominal Particulate
Class I|

EPA Est. No. 002623-IL-002PENTAIR EVERPURE PBS-400 Water Filtration System -
fig

For Everpure ®  Product Warranties visit:

FILTRATION & PROCESS
5730 NORTH GLEN PARK ROAD, MILWAUKEE, WI 53209
P: 262.238.4400 | WWW.PENTAIRAQUA.COM | CUSTOMER CARE: 800.279.9404 | tech-support@pentair.com
All Pentair trademarks and logos are owned by Pentair, Inc. or its affiliates. All other registered and unregistered trademarks and logos are the property of their respective owners. Because we are continuously improving our products and services. Pentair reserves the right to change specifications without prior notice.
Pentair is an equal opportunity employer.
4004796 REV A MY16 © 2016 Pentair Residential Filtration, LLC All Rights Reserved.
www.pentairaqua.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Pentair User Manuals

Related Manuals