CROSSIO LifePower 1000 Portable Power Station User Manual

June 12, 2024
CROSSIO

CROSSIO LifePower 1000 Portable Power Station

Product Description

The LifePower 1000 is a portable power station designed by CROSSIO in the Czech Republic and assembled in China. It is a versatile power solution that allows you to charge multiple devices simultaneously.

Package Content

  • LifePower 1000 power station
  • AC Input cable
  • Solar Input cable
  • Car Charger Input cable

LCD Display

The LCD display on the LifePower 1000 provides important information about the power station’s status:

  • A. Input power: Current input power (Watts).
  • B. Output power: Current output power (Watts).
  • C. Remaining time or the error code signalization: A dual-purpose icon used for time remaining to fully charge / discharge the battery or the error code. When a fault occurs, the icon is shown as an error code. See the Error Code Table for details.
  • D. Fan: Fan ON/OFF status.
  • E. DC: DC ON/OFF status.
  • F. USB: USB-A ON/OFF status.
  • G. Over-temperature: Indicates whether the battery / inverter temperature exceeds a safe value.
  • H. Fault warning: Indicates whether a fault occurs.
  • I. USB-C: USB-C ON/OFF status.
  • J. AC: AC ON/OFF status.
  • K. AC frequency: Current operating frequency of the AC output ports (50 or 60 Hz).
  • L. Overload: Indicates the AC output overload.
  • M. Battery percentage: Current remaining battery. When the remaining battery is 0%, the icon starts blinking. Recharge the product immediately.
  • N. Charge/discharge status ring: Indicates whether the battery is charging or discharging. When charging – the ring keeps spinning, when showing remaining time the ring will be static and each part of the ring will gradually disappear according to the remaining battery capacity.

Technical Specifications

  • Battery Capacity: 1075.2Wh (42Ah/25.6V)
  • Battery Type: LiFePO4 battery (electric vehicle grade)
  • Inputs:
    • AC Input: 220V-240V~2.72A 600W
    • Solar Input: 12V-30V6.2A 150W, 2x DC5525, 300W (Max)
    • Car Charger Input: 12V-24V5A
  • Outputs:
    • 1xAC Output: 220V-240V~4.35A; Continuous 1000W (peak 2000W); frequency 50Hz
    • 2xUSB-A(Fast Charge) Output: 5V3A;9V2A;12V1.5A 18W (Max)
    • 2xUSB-A Output: Total 36W (Max)
    • 2xUSB-C(PD) Output: 5V,9V,12V,15V3A,20V2.25A 45W (Max), (2xUSB-C: Total 90W Max)
    • 2xUSB-C(PD) Output: 5V,9V,12V,15V3A;20V5A 100W (Max), (2xUSB-C: Total 200 Max)
    • 2xDC 5521 Output: 12V5A 60W, Total 120W (Max)
    • 1xCar Charger Output: 12V10A 120W, 2xDC+1xCar Charger: Total 120W (Max)
  • Life Cycles: 3500 times
  • Weight: 14.5kg
  • Size: 340224266mm
  • Operating Temperature: -10°C to 40°C
  • Charging Temperature: 0°C to 45°C
  • LED Light: Yes
  • AC Charging: Yes
  • Car Charger Charging: Yes
  • Solar Panel Charging: Yes

Operation

When the power station is connected to an AC power source, a solar panel, and a car charger at the same time, the AC input is prioritized to charge the power station while the DC inputs (solar panel, car charger) are disabled to charge the power station. The screen automatically goes Off if no operation is conducted in 5 minutes after the product is turned On. Press any button to light up the screen again.

Disclaimer

Read all instructions carefully regarding using this product. If you do not follow the safety instructions and information regarding proper handling in this user manual, we accept no liability for any related personal injury or damage to property. This user manual is intended to assist you in using the product. Software and hardware specifications in this user manual are for reference purpose only. All pictures shown in this manual are for the illustration purpose only. Actual product may vary. CROSSIO reserves the right of final interpretation for the content in this user manual and all documents associated with this product. CROSSIO also reserves the right to update, change or terminate this user manual without a prior notice.

Safety Instructions

  • Producing a pure sine wave output, this product is compatible with sine wave AC electric appliances with a power of ≤1000W.
  • Keep the product out of the reach of children. Close supervision is necessary when the product is used near children.
  • Use accessories recommended or sold by CROSSIO. Otherwise, it may cause electric shock.
  • Disconnect the product from the power supply when the product is not in use.
  • Never disassemble the product. Disassembling the product may cause hazards such as fire or electric shock!
  • Do not cover the ventilation slots on the product in any way to prevent overheating.
  • Put the product in a ventilated and dry place.
  • Follow local rules to dispose of the old product. Never dispose of the built-in battery with normal household waste to avoid pollution.
  • Do not put your finger, palm or any part of your body into the product.
  • Do not throw the product into a fire, water or other liquids. Protect the product from extreme temperatures.
  • Do not place the product under heavy objects. Do not subject the product to strong impacts, such as letting it fall.
  • Do not cover the product with towels and clothes when it is in use.
  • Disconnect the product from the power outlet promptly after it is fully charged.
  • Never insert metal objects into the connectors or other openings on the product otherwise there is a risk of electric shock and personal injury!
  • Make sure the screen is “On” before you use any button to operate the product. If the screen is “Off”, wake it up by pressing any button, then you can perform other operations.

Package Content

  • CROSSIO LifePower 1000
  • AC charging cable
  • MC4 to DC5525 cable
  • Car charger to DC5525 cable
  • CROSSIO accessory bag

Product Description

CROSSIO LifePower 1000 Portable Power Station-FIG1

CROSSIO LifePower 1000 Portable Power Station-FIG2

LCD Display

  • A. Input power: Current input power (Watts).
  • B. Output power: Current output power (Watts).
  • C. Remaining time or the error code signalization: A dual-purpose icon used for time remaining to fully charge / discharge the battery or the error code. When a fault occurs, the icon is shown as an error code. See the Error Code Table for details.
  • D. Fan: Fan ON/OFF status.
  • E. DC: DC ON/OFF status.
  • F. USB: USB-A ON/OFF status.
  • G. Over-temperature: Indicates whether the battery / inverter temperature exceeds a safe value.
  • H. Fault warning: Indicates whether a fault occurs.
  • I. USB-C: USB-C ON/OFF status.
  • J. AC: AC ON/OFF status.
  • K. AC frequency: Current operating frequency of the AC output ports (50 or 60 Hz).
  • L. Overload: Indicates the AC output overload.
    • The current battery percentage and remaining battery in hours displayed are for reference only. Actual data may vary.
    • This product has a built-in intelligent cooling system. The intelligent cooling fan is automatically turned on to cool the product down when the product temperature exceeds the limit. The cooling fan may produce noise, which is normal.
    • If an over-temperature protection is triggered during the use of this product, the over-temperature icon on the screen blinks and all input/output ports stop working. Wait until the battery temperature returns to the normal range and restart the product. Note: The product will enter the over-temperature protection mode and stop working when its temperature becomes too low or too high.
  • M. Battery percentage: Current remaining battery. When the remaining battery is 0%, the icon starts blinking. Recharge the product immediately.
  • N. Charge/discharge status ring: Indicates whether the battery is charging or discharging. When charging – the ring keeps spinning, when showing remaining time the ring will be static and each part of the ring will gradually disappear according to the remaining battery capacity.

Technical Specifications

Battery Capacity 1075.2Wh (42Ah/25.6V)
Battery Type LiFePO4 battery (electric vehicle grade)
Inputs AC: 220V-240V~2.72A 600W

Car Charger: 12V-24V⎓5A

Solar Charging: 12V-30V⎓6.2A 150W, 2x DC5525, 300W (Max)

\

Outputs| 1xAC: 220V-240V~4.35A; Continuous 1000W (peak 2000W); frequency 50Hz

2xUSB-A(Fast Charge): 5V⎓3A;9V⎓2A;12V⎓1.5A 18W

(Max), 2xUSB-A: Total 36W (Max)

2xUSB-C(PD):5V,9V,12V,15V⎓3A,20V⎓2.25A 45W

(Max), (2xUSB-C: Total 90W Max)

2xUSB-C(PD): 5V,9V,12V,15V⎓3A;20V⎓5A 100W (Max),

(2xUSB-C: Total 200 Max)

2xDC 5521: 12V⎓5A 60W, Total 120W (Max)

1xCar Charger: 12V⎓10A 120W, 2xDC+1xCar Charger: Total 120W (Max)

---|---
Life Cycles| ≥3500 times
Weight| 14.5kg
Size| 340224266mm
Operating Temperature| -15°~45°
Charging Temperature| 0°-45°
LED

Light

| 10W, 3 working modes (High-Low-SOS)
AC

Charging

| Charged to 80% in 1.6 hour
Car Charger Charging| Charged to 80% in 16-18 hours (12V), 8-9 hours (24V)
Solar Panel Charging| Charged to 80% in 4-6 hours with 2x 150W solar panel

To manually switch from 50Hz to 60Hz, turn the AC power button Off and then press AC and DC power buttons at the same time for 3s.

Operation

Inputs

When the power station is connected to an AC power source, a solar panel and a car charger at the same time, the AC input is prioritized to charge the power station while the DC inputs (solar panel, car charger) are disabled to charge the power station.
The screen automatically goes Off if no operation is conducted in 5 minutes after the product is turned On. Press any button to light up the screen again.

AC Input

CROSSIO LifePower 1000 Portable Power Station-FIG3

  1. To recharge the power station, connect it to a wall socket with the AC charging cable.When the power station is connected to an AC power source, the screen automatically lights up. Pressing the Power button cannot turn Off the product and screen while charging.
  2. When the product is charging, the charge/discharge status ring on the screen keeps spinning. Meanwhile, the current battery percentage, current charging power and time to recharge will be changing on the screen.
  3. The product is fully charged when the charge/discharge status ring stops spinning, the battery percentage displayed turns to 100% and time remaining to fully charge turns to 0. Disconnect the AC charging cable from the wall socket.

Solar Input

CROSSIO LifePower 1000 Portable Power Station-FIG4

  1. To recharge the power station with the solar panel, you can use the provided MC4 to DC5.5mm cable to connect the DC5.5×2.5mm input port of the power station to the solar panel. LifePower 1000 supports dual solar charging via 2 DC 5.5×2.5mm ports (150W each).
  2. When the product is charging, the charge/discharge status ring on the screen keeps spinning. Meanwhile, the current battery percentage, current charging power and time to recharge will be changing on the screen.
  3. The product is fully charged when the charge/discharge status ring stops spinning, the battery percentage displayed turns to 100% and time remaining to fully charge turns to 0. Disconnect the charging cable from the power station.

With a built-in MPPT controller, the DC5.5×2.5 solar input port supports 12-30V solar input. Do not charge the product via solar panels with an operating voltage outside this range. There is a risk of damage to the product!

MANUAL

Car Charger Input

CROSSIO LifePower 1000 Portable Power Station-FIG5

  1. To recharge the power station via a car charger, use the provided car charger to DC5.5mm cable to connect the DC5.5×2.5mm input port of the power station to the car charger.
  2. When the product is recharging, the charge/discharge status ring on the screen keeps spinning. Meanwhile, the current battery percentage, current charging power and time to recharge will be changing on the screen.
  3. The product is fully charged when the charge/discharge status ring stops spinning, the battery percentage displayed turns to 100% and time remaining to fully charge turns to 0. Disconnect the charging cable from the power station.
    It is normal that the car charger socket gets hot while charging. Do not touch it to avoid skin burn.
    Start the car engine before using the car charger to recharge your powerstation and prevent your car from running out of battery.

Outputs

AC Output

CROSSIO LifePower 1000 Portable Power Station-FIG6

  1. Press and hold the Power button for 3 seconds to turn the power station On. The screen and the backlight around the button will light up.

  2. Press the AC switch, the backlight around the switch and the AC icon on the screen will light up.

  3. To power your appliance, simply connect it to the power station.
    For devices with a rated power of less than 1000W, the peak power may exceed 200W. At this time, an overload protection will be triggered and the AC switch may be turned Off. It is recommended to connect your electric appliance before turning On the AC switch to avoid this situation. All AC output ports are disabled when:

    • The AC load power exceeds 1050W (or the current exceeds 14A) and lasts for more than 10 minutes.
    • The AC output power exceeds 1200W (or the current exceeds 15A) and lasts for more than 1 minute.
    • The AC output power exceeds 1400W (or the current exceeds 16A) and lasts for more than 30 seconds.
    • Meanwhile, the fault warning icon and overload icon keep blinking for one minute and the corresponding error code is displayed. If overload protection
    • happens three times, LifePower 1000 will be locked automatically. You have to restart the power station to unlock it.
    • When the load power is less than 5W, the AC output will shut down after 8 hours.
    • Turn Off the AC output when it is not in use to reduce the power consumption of the power station.

UPS Function

(Uninterruptible Power Supply)

  • Turn On the AC output first. To use the UPS function, connect LifePower 1000 to a wall socket with the AC charging cable, then connect your devices with the AC output ports on the power station. At this time, the electricity supplied to your devices comes from the grid.
  • When there is a power outage, LifePower 1000 automatically starts to supply electricity to your devices through its battery within 10ms. Before using this power station to supply electricity to devices with stronger need for power supplies, such as the CPAP machine, perform repeated tests to ensure the compatibility with UPS. To avoid overload protection, make sure the load of the devices connected is less than the rated power (100W) of the power station.
  • For safety reasons, connect your appliance to the portable power station before turning on the AC switch. Make sure your appliance is Off when connecting.
  • During pass-through charging, the input power displayed on the screen is the sum of the output power and the battery charging power. Actual data may vary. When the LifePower 1000 is connected to the electric grid and the UPS fails, grid AC power supply is automatically enabled (Bypass mode). In Bypass mode, the total power of the loads cannot exceed the bypass output power limit, which is 1900W. Otherwise, overload protection will be triggered and the AC output will be stopped.

BoostUp Mode

BoosUp mode can be used for device(s) which require continuous power between 1000W-1960W. BoostUp will automatically lower the power requirement of each connected device and balance it in a way the maximum output does not exceed 1000W. The overload protection will not be triggered in this mode.

  • To turn On the BoostUp press and hold the AC switch for 3 seconds, the backlight of the AC switch changes from blue color to orange color.
  • Boost-Up mode might not be applicable for all electric appliances such as those with rated power of more than 1960W, strict voltage requirements and voltage protection (e.g., precision instruments) may not work in the Boost-Up mode. Please, test it before use.
  • When the Boost-Up mode is not enabled, output exceeding 1000W will trigger overload protection and shut down the AC output in 10 minutes. After three consecutive overloads, the AC output will become unavailable. You need to recover it by restarting the power station.

USB-A and USB-C Outputs

CROSSIO LifePower 1000 Portable Power Station-FIG7

  1. Press and hold the Power button for 3 seconds to turn the power station On. The display lights up.
  2. Press the DC switch, the USB-A and USB-C icons on the screen will light up. Ports are ready to use.
    • If the USB output port is short-circuited or the load power exceeds the output power limit, a short-circuit protection or overcurrent protection will be triggered and the output port in use will be disabled automatically. Disconnect the appliance, the USB output will be recovered automatically.
    • When the load power is less than 5W, LifePower 600 will be turned Off in 8 hours.
    • Turn Off the DC Power button when it is not in use.

DC Output

CROSSIO LifePower 1000 Portable Power Station-FIG8

  1. Press and hold the Power button for 3 seconds to turn the power station On. The screen lights up.
  2. Press the DC switch, the DC icon on the screen lights up.
  3. To power your appliance, connect it to the DC output port of this product.
    • When the output power of a single DC 5521 port exceeds 60W, overcurrent/overload protection will be triggered and the port in use will be disabled. When the output of the car charger exceeds 120W, overcurrent/overload protection will be triggered and the car charger port will be disabled. After the load is disconnected, the output will be recovered automatically.
    • For safety reasons, connect your appliance to the portable power station before turning On the AC switch. Make sure your appliance is Off when connecting.
    • When the load power is less than 5W, LifePower 600 will be turned Off in 8 hours.
    • Turn off the product when it is not in use.

LED Light

  1. Press and hold the LED switch for 2 seconds to turn the LED light on. The LED light switch is not controlled via the Power button.
  2. The LED light has three working modes: High-Low-SOS. Press and hold the LED switch for 2 seconds, the light enters the High mode. Press the LED switch again to switch between the three modes.
  3. Press and hold the LED switch for 2 seconds again to turn the LED light Off. Protect your eyes and do not look directly into the LED light!

Reset Button

  • Press and hold the reset button for 3 seconds to reset the power station. The screen is refreshed and the remaining battery is reset.
  • The remaining battery displayed after resetting is inaccurate as it is estimated according to the current state of the battery cells. To accurately display the remaining battery, calibrate it through a full discharge/charge cycle.
  • The reset button should be used only when you discover that the remaining battery displayed is inaccurate.

Battery Instructions.

  • The product comes with a built-in EV-grade lithium iron phosphate (LiFePO4) battery. LiFePO4 batteries have larger capacity, longer life span and show no memory effects.
  • However, due to the chemical characteristics of LiFePO4 batteries, the battery capacity is reduced at low temperatures (e.g. below -10°). To achieve the optimal charge and discharge capacity, it is recommended to use the power station at 10° to 30°.
  • If the maximum battery charge level is often set to below 80% (after every five charge/discharge cycles) please manually set it to 100% and complete at least one full charge/discharge cycle to maintain the accuracy of battery state of charge (SOC).
  • To prolong the lifespan of the power station and its LiFePO4 battery, it is recommended to charge and discharge the battery completely at least once every 3 months.

Error Code Table

00| Inverter overvoltage| Disconnect the device and turn On the AC switch again after. The electric appliances must be used within the rated range.
---|---|---
01| Inverter undervoltage| Disconnect the device and turn On the AC switch again after. The electric appliances must be used within the rated range..
02| Inverter overcurrent| Disconnect the device and turn On the AC switch again after. The electric appliances must be used within the rated range.
---|---|---
04| Inverter is short-circuited| Disconnect the device and turn On the AC switch again after. The electric appliances must be used within the rated range.
05| Inverter overload warning| Disconnect the device and turn On the AC switch again after. The electric appliances must be used within the rated range.
06| Inverter overload protection| Disconnect the device and turn On the AC switch again after. The electric appliances must be used within the rated range.
07| Inverter fuse fault| Contact ILICO Europe RMA service team.
08| Inverter relay fault| Contact ILICO Europe RMA service team.
16| Battery overvoltage warning| Contact ILICO Europe RMA service team.
17| Battery overvoltage protection| Contact ILICO Europe RMA service team.
18| Battery undervoltage warning| The battery power is too low. Recharge the battery.
19| Battery undervoltage protection| The battery power is too low. Recharge the battery.
20| Battery overcurrent| Contact ILICO Europe RMA service team.
24| Battery fuse fault| Contact ILICO Europe RMA service team.
25| Battery relay fault| Contact ILICO Europe RMA service team.
---|---|---
40| Bypass overvoltage| Make the device’s voltage match the grid power.
41| Bypass undervoltage| Make the device’s voltage match the grid power.
42| Bypass over frequency| This problem is resolved after the device’s frequency is set correctly.
43| Bypass underfrequency| This problem is resolved after the device’s frequency is set correctly.
44| Bypass is short- circuited| Disconnect the device and turn On the AC switch again after. The electric appliances must be used within the rated range.
45| Bypass overload warning| Disconnect the device and turn On the AC switch again after. The electric appliances must be used within the rated range.
46| Bypass overload protection| Disconnect the device and turn On the AC switch again after. The electric appliances must be used within the rated range.
47| Bypass fuse fault| Contact ILICO Europe RMA service team.
48| Bypass relay fault| Contact ILICO Europe RMA service team.
88| Radiator over- temperature warning| Cool down the radiator.
89| Radiator over- temperature protection| Cool down the radiator.
90| Radiator low- temperature warning| Warm the radiator.
---|---|---
91| Radiator low- temperature protection| Warm the radiator.
92| Radiator thermostat is not connected| Contact ILICO Europe RMA service team.
93| Interior over- temperature warning| Cool down the inside of the power station.
94| Interior over- temperature protection| Cool down the inside of the power station.
95| Incorrect voltage/ product model setting| Contact ILICO Europe RMA service team.
99| Internal fault| Contact ILICO Europe RMA service team.

Warranty Service

Responsible for service of this power station is ILICO Europe s.r.o.
All questions or complications can be sent to [email protected] or you can call us +420 735 035 000.

What we need for the correct and speed settlement:

  1. Order number and date when the defect was found.
  2. Description of the defect and problematic situation.

Warranty does not apply to:

  • Defects found after the warranty time.
  • Defects caused by the improper handling with the power station.
  • Defects caused by the water.
  • Defects caused by the transport.
  • Defects caused by natural disasters.
  • Cosmetics defects, if the power station is working correctly.
  • Power station, which was opened by an unauthorized person.

Warranty service conditions:

  • Complaint is possible only with the proof of purchase.
  • The way the RMA is resolved depends on the RMA technician with professional statements of the manufacturer, supplier or service.
  • In the case of repair or replacement the RMA will be settled in a period of 30 calendar days by law. For the replacement or for the repair can be used a functional refurbished component from another power station.

Distribution: ILICO Europe s.r.o., VAT: CZ06385974

Designed by CROSSIO in the Czech Republic Assembled in China

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

CROSSIO User Manuals

Related Manuals