LARK 83887LCB LED Convertible Pendant Lulu Instruction Manual

June 12, 2024
LARK

Assembly Instructions
Item No: 83884-83887

83887LCB LED Convertible Pendant Lulu

  1. Find a clear area in which you can work.
  2. Unpack fixture and glass from carton.
  3. Carefully review instructions prior to assembly.

DRAWING 1 – MOUNTING

  1. Release mounting strap (S) by removing screws (A)
  2. Secure mounting strap (S) to junction box (J) using two 8/32″ screws (B) (provided)
  3. Complete wiring connections using IS 18 provided
  4. Secure canopy (C) to mounting strap (S) using the screws in the side of canopy (A)

DRAWING 2- Fixture height adjustment

  1. To adjust fixture height use allen key (T) to loosen set screw (F)
  2.  Adjust cord to desired length. Note: if strain relief (K) is making adjusting the cord difficult, stain relief can be removed to adjust cord and replaced once cord is at desired length
  3. Tighten set screw (F) to secure cord into place

DRAWING 3- Assembly

  1. Place decorative plate (2) over socket (1)
  2. Use socket ring (3) to secure decorative plate (2) to socket (1)
  3. Lamp fixture using appropriate medium base bulb (4)
  4. Fixture can now be be powered on

Drawing 1 – Flush Mount| Drawing 2 – Chain Hung| Drawing 3 – Post-Mount
---|---|---
| |

I.S. 18 wiring grounding instructions
SAFETY WARNING: READ WIRING AND GROUNDING INSTRUCTIONS (IS 18) AND ANY ADDITIONAL DIRECTIONS.
TURN POWER SUPPLY OFF DURING INSTALLATION. IF NEW WIRING IS REQUIRED, CONSULT A QUALIFIED ELECTRICIAN OR LOCAL AUTHORITIES FOR CODE REQUIREMENTS

Wiring instructions

Indoor Fixtures

  1. Connect positive supply wire (A) (typically black or the smooth, unmarked side of the two-conductor cord) to positive fixture lead (B) with appropriately sized twist on connector – see Drawings 1 or 2.
  2. Connect negative supply wire (C) (typically white or the ribbed, marked side of the two-conductor cord) to negative fixture lead (D).
  3. Please refer to the grounding instructions below to complete all electrical connections

Outdoor Fixtures

  1. Connect positive supply wire (A) (typically black or the smooth unmarked side of the two-conductor cord) to positive fixture lead (B) with appropriately sized twist on connector – – – see Drawings 2 or 3.
  2. Connect negative supply wire (C) (typically white or the ribbed, marked side of the two-conductor cord) to negative fixture lead (D).
  3. Cover open end of connectors with silicone sealant to form a watertight seal. If installing a wall mount fixture, use caulk to seal gaps between the fixture mounting plate (backplate) and the wall. This will help prevent water from entering the outlet box. If the wall surface is lap siding, use caulk and a fixture mounting platform specially.
  4. Please refer to the grounding instructions below to complete all electrical connections.

Grounding instructions

Flush Mount Fixtures
For positive grounding in a 3-wire electrical system, fasten the fixture ground wire (E) (typically copper or green plastic coated) to the fixture mounting strap (M) with the ground screw (S) – see Drawing 1.
Note: On straps for screw supported fixtures, first install the two mounting screws in strap. Any remaining tapped hole may be used for the ground screw.
Chain Hung Fixtures
Loop fixture ground wire (E) (typically copper or green plastic coated) under the head of the ground screw (S) on fixture mounting strap (M) and connect to the loose end of the fixture ground wire directly to the ground wire of the building system with appropriately sized twist-on connectors – see Drawing 2.
Post-Mount Fixtures
Connect fixture ground wire (E) (typically copper or green plastic coated) to power supply ground with appropriately sized twist-on connector inside post. Cover open end of connector with silicone sealant to form a watertight seal – see Drawing 3.

33000 PIN OAK PARKWAY, AVON LAKE, OH 44012
LarkLiving.com