RENOGY RBT12200LFP-US Deep Cycle Lithium Iron Phosphate Battery User Manual
- June 12, 2024
- Renogy
Table of Contents
- RENOGY RBT12200LFP-US Deep Cycle Lithium Iron Phosphate Battery
- Product Information
- Product Usage Instructions
- Before Getting Started
- Disclaimer
- Symbols Used
- Introduction
- What’s In the Box
- Get to Know
- Dimensions
- Battery Settings
- How to Connect Renogy Core Batteries
- Charging/Discharging Parameter Settings
- How to Estimate the Battery SOC
- Battery Management System
- Troubleshooting
- Specifications
- Maintenance & Storage
- Important Safety Instructions
- Renogy Support
- FCC Statement
- More Information
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
RENOGY RBT12200LFP-US Deep Cycle Lithium Iron Phosphate Battery
Product Information
The Renogy Core Series Deep Cycle Lithium Iron Phosphate Battery is a high- performance battery designed for various applications. It has a voltage of 12.8V and a capacity of 200Ah, providing reliable power for your devices.
Key Features
- Unparalleled Performance: The battery offers greater energy density, deeper discharge capability, higher round-trip efficiency, and faster charging speed compared to other batteries in the market.
Product Usage Instructions
Before using the Renogy Core Series Deep Cycle Lithium Iron Phosphate Battery, it is important to read and understand the user manual for proper operation and maintenance.
Important Safety Instructions
Ensure your safety and prevent damage to the battery by following these safety instructions:
- Read the user manual carefully before operating the battery.
- Save the user manual for future reference.
- Failure to follow the instructions can result in electrical shock, serious injury, or damage to the battery.
Before Getting Started
- The user manual provides important operation and maintenance instructions for Renogy Core Series 12.8V 200Ah Deep Cycle Lithium Iron Phosphate Battery (hereinafter referred to as battery).
- Read the user manual carefully before operation and save it for future reference. Failure to observe the instructions or precautions in the user manual can result in electrical shock, serious injury, or death, or can damage the battery, potentially rendering it inoperable.
- Renogy ensures the accuracy, sufficiency, and the applicability of information in the user manual at the time of printing due to continual product improvements that may occur.
- Renogy assumes no responsibility or liability for personal and property losses, whether directly and indirectly, caused by the user’s failure to install and use the product in compliance with the user manual.
- Renogy is not responsible or liable for any failure, damage, or injury resulting from repair attempts by unqualified personnel, improper installation, or inappropriate operation.
- The illustrations in the user manual are for demonstration purposes only. Details may appear slightly different depending on product revision and market region.
- Renogy reserves the right to change the information in the user manual without notice. For the latest user manual, visit renogy.com.
Disclaimer
- Renogy Core Series 12.8V 200Ah Deep Cycle Lithium Iron Phosphate Battery User Manual © 2023 Renogy. All rights reserved.
- RENOGY and RENOGY are registered trademarks of Renogy.
- All information in the user manual is subject to copyright and other intellectual property rights of Renogy and its licensors. The user manual may not be modified, reproduced, or copied, in whole or in part, without the prior written permissions of Renogy and its licensors.
- The registered trademarks in the user manual are the property of Renogy. The unauthorized use of the trademarks is strictly prohibited.
Online Manual
Symbols Used
The following symbols are used throughout the user manual to highlight important information.
WARNING: Indicates a potentially dangerous condition which could result in injury or death.
CAUTION: Indicates a critical procedure for safe and proper installation and operation.
NOTE: Indicates an important step or tip for optimal performance.
Introduction
The Renogy Core Series 12.8V 200Ah Deep Cycle Lithium Iron Phosphate Battery
is designed for the drop-in replacement of deep-cycle lead-acid batteries with
its standard Battery Council International (BCI) group size.
Weighing only half of the lead-acid counterparts, the battery can be safely
discharged to 100% Depth of Discharge (DOD), delivering twice the energy.
Manufactured with automotive grade battery cells, the battery features the
highest safety standards and an extended 5000+ cycle life. In addition, the
reliable Battery Management System (BMS) provides comprehensive protection to
the battery.
Key Features
- Unparalleled Performance
- Features a greater energy density, a deeper discharge capability, a higher round-trip efficiency, and a faster charging speed in a smaller size over counterparts in the market.
- Uncompromising Quality
- Ensures an exceptional lifespan with more than 5000 cycles (80% DOD), a continuous charge current of 100A and a continuous discharge current of 200A, and a wide range of operating temperatures with the automotive grade battery cells.
- Reliable Protection Mechanisms
- Designed with a sturdy internal structure for RV use, and includes multiple levels of protection such as low temperature cut-off and precise balancing through the battery management system.
- Higher Capacity than Competitors
- 212Ah instead of 200Ah, for a longer-lasting application.
- Easy to Expand
- Upgrades to lithium batteries seamlessly with the standard BCI group sizes; up to 16 batteries in 4 series and 4 parallels system connection delivering a maximum of 48V (51.2V) 800Ah with 40.96 kWh.
SKU
- Renogy Core Series 12.8V 200Ah Deep Cycle Lithium Iron Phosphate Battery: RBT12200LFP-US
What’s In the Box
_ Warning: _Make sure that all accessories are complete and free of any signs of damage.
Required Tools & Accessories
- Prior to installing and configuring the battery, prepare the recommended tools, components, and accessories.
- For how to size battery adapter cables, refer to “How to Size Battery Adapter Cables?” in this manual.
Get to Know
Get to Know Deep Cycle Lithium Iron Phosphate Battery
Dimensions
- Dimension tolerance: ±0.2 in (0.5 mm)
Battery Settings
How to Size Battery Adapter Cables?
Use appropriately sized Battery Adapter Cables (sold separately) based on expected load. Refer to the table below for copper cable ampacities with different gauge sizes.
The above values are from the NEC Table 310.17 for copper cables rated at 194°F (90°C), operating at an ambient temperature of no more than 86°F (30°C). Cables longer than 13 feet (4000 mm) may require thicker gauge wires to prevent excessive voltage drop in undersized wiring.
Fix the Battery to a Position (Optional)
- Securing the battery prevents damage to the battery from loose cables and bumps.
Recommended Components
Warning: Alternative mounting methods are allowed to meet the requirements of specific applications.
Step 1: Plan a Mounting Site
For optimal battery performance, it is recommended to install the battery in a clean, cool, and dry location, free from any accumulation of water, oil, or dirt. Accumulation of such materials on the battery can lead to current leakage, self-discharge, and even short-circuiting.
-
Sufficient air flow must be provided to prevent excessive heat build-up and to minimize temperature variation between the connected batteries.
-
This user manual takes a battery as an example to illustrate how to install the battery.
-
Charge: 32°F–131°F / 0°C–55°C
- Discharge: -4°F–140°F / -20°C–60°C
-
10%–95%
Step 2: Wear Insulating Gloves
Step 3: Remove the Dust Cover
Step 4: Check the Battery
Inspect the battery for any visible damage including cracks, dents, deformation, and other visible abnormalities. All connector contacts shall be clean, free of dirt and corrosion, and dry.
Warning
- Do not touch the exposed electrolyte or powder if the battery is damaged.
- If uncovered electrolyte or powder contacts your skin or eyes, flush it out immediately with plenty of clean water and seek medical attention.
Step 5: Run the Battery Adapter Cables Through the Insulating Sleeves
Step 6: Install Battery Terminals
Warning
- Ensure the cable lug and the top surface of the terminal are in contact, and place the washers on top of the lug. Do not place the washers between the battery terminal and the cable lug to avoid high resistance and excessive heating.
- Avoid short-circuiting the battery terminals to prevent irreversible damage to the system and battery caused by current bursts.
- Verify polarity before wiring to avoid irreversible battery damage due to polarity reversal.
- To ensure safe and reliable operation of the system, please follow the manufacturer’s recommended torque specifications when securing cable connections. Over-tightening can result in terminal breakage, while loose connections can lead to terminal meltdown or fire. When securing multiple cable lugs on a single battery terminal, use the included Long Terminal Bolts.
Step 7: Install the Insulating Sleeves
Step 8: Connect the Battery to Other Devices
_ Warning: _Please use circuit breakers, fuses, or disconnects appropriately sized by a certified electrician, licensed installers, or regional code authorities to protect all electrical equipment.
For a Single Battery
For Batteries in Parallel
For Batteries in Series
How to Connect Renogy Core Batteries
How to Connect Renogy Core Batteries in Series or Parallel
Calculate Voltage and Current in Series and Parallel Connections
-
Parallel Connection
- 12V(12.8V) 800Ah
-
Series Connection
- 48V(51.2V) 200Ah
Warning
- Do not connect batteries with different chemistries, rated capacities, nominal voltages, brands, or models in parallel or in series. This can result in potential damage to the batteries and the connected devices, and can also pose safety risks.
- Avoid connecting batteries that have been purchased for more than half a year. Over time, batteries can degrade and their performance may decrease, which can affect their ability to deliver reliable power and may lead to safety hazards.
- The cables between each connected battery should be of equal length to ensure that all batteries can work equally together.
- You can connect up to 8 batteries in parallel or 4 batteries in series.
Balance Batteries Prior to Connection
Before connecting batteries in series or parallel, it is important to balance them to reduce voltage differences and optimize their performance. Follow these three steps:
- Step 1: Charge each battery individually to its full capacity using a suitable charger.
- Step 2: Use a voltmeter to measure the voltage of each battery. It is best to keep the voltage difference of each battery less than 0.1V.
- Step 3: Connect all the batteries in parallel and allow them to rest together for 12 to 24 hours.
Warning
It is recommended to periodically rebalance the battery voltages every six months when connecting multiple batteries as a battery system. Slight voltage differences can occur among batteries over time due to factors like battery chemistry, capacity, temperature, and usage patterns.
Series Connection vs. Parallel Connection — Installation Steps
- You can choose suitable busbars in series and parallel connections. Busbars help handle high currents and are typically arranged in a parallel or stacked configuration to distribute electrical power efficiently.
- Note that the cable connection methods provided below are for reference purposes only, as the optimal approach may vary depending on the specific situation. It is essential to consider various factors, such as the cable size, equipment used, and environmental conditions.
Parallel Connection
Series Connection
Parallel & Series Connection
Battery Cell Balancing
The battery employs bypass circuit to maintain the balance between each battery cell group. Each battery cell group is connected with a bypass resistor and a switch in parallel. During the charging process, if the highest-voltage battery cell group reaches the set balancing starting voltage and the voltage difference between the highest-voltage and the lowest-voltage battery cell group exceeds the set voltage difference, the switch connected to the highest-voltage battery cell group will be closed to shunt the charge current around the highest-voltage battery cell group through the bypass resistor until the voltage difference drops below the set value. To avoid excessive energy loss, the battery cell balancing is only performed during the charging process.
Charging/Discharging Parameter Settings
Charge
Discharge
Warning: The parameters in the table are applicable to 12V (12.8V) battery packs. Please multiply by 2 for 24V (25.6V) packs and multiply by 4 for 48V (51.2V) packs.
Battery Charging and Discharging Logic
The battery may be received at a partial state of charge (SOC) depending on the time between manufacturing and shipping. It is crucial to fully charge the battery before its initial use. In case the battery shuts off due to low SOC, promptly disconnect it from loads and charge it to prevent irreversible damage. Follow the instructions in this user manual for proper charging and usage to ensure optimal battery performance and longevity.
Charging Logic
The standard charging process for the battery involves charging at a constant current of 100A until the battery voltage reaches 14.4V, followed by charging at a constant voltage of 14.4V while tapering the charge current. The charging process is considered complete when the charge current is less than 10A (also known as tail current). The standard charging process typically takes 2.5 hours and requires battery temperatures to be between 32°F and 131°F (0°C and 55°C) for safe charging. Leaving the battery on float will continue to balance the battery cells without damaging the battery.
Warning
- Lithium batteries are compatible with various charging methods, including MPPT charge controller, AC charger, and DC-DC charger. The crucial parameter setting for these chargers is to set the charge voltage, boost voltage, or bulk voltage at 14.4V (±0.2V).
- Do not overcharge or overdischarge the battery.
- Do not charge the battery at low temperatures below 32°F (0°C) and discharge the battery at high temperatures above 140°F (60°C).
- Only charge the battery with a battery charger or charge controller that is compatible with lithium iron phosphate batteries.
- Do not exceed the maximum continuous charge current (100A) of the battery.
Discharging Logic
- During standard discharging, the battery is discharged at a constant current of 100A until the voltage drops to 10V. To ensure safe discharging, the battery temperature should be between -4°F (-20°C) and 131°F (60°C).
- To ensure safe and optimal battery usage, it is recommended to pair the battery with discharge equipment that features a low voltage disconnect (LVD) function.
- Do not connect large loads to the battery when it is running low.
- Do not exceed the maximum continuous discharge current (200A) of the battery.
How to Estimate the Battery SOC
- The SOC values listed below are estimated based on the resting voltage when the battery is at rest for 30 minutes, not in charging or discharging state.
- The table above is for reference only because slight variations in battery voltage may occur among different batteries.
Battery Management System
The battery is equipped with a Battery Management System (BMS) that provides warnings and protections against overvoltage, undervoltage, overcurrent, short circuit, high temperature, and low temperature conditions. Refer to the table below for the triggering and recovery conditions of each warning and protection.
Troubleshooting
For further assitance, contact Renogy technical support service at: https://www.renogy.com/contact-us.
Specifications
General
Operation Parameters
Maintenance & Storage
Inspection
Please perform regular inspections following the steps below:
- Examine the external appearance of the battery. The housing and terminals of the battery shall be clean, dry, and free of corrosion.
- Check battery cables and connections. Replace any damaged cables and tighten any loose connections.
Warning: In certain application scenarios, corrosion may occur around the terminals. Corrosion can cause increased resistance and poor contact. It is recommended to regularly apply insulation grease to each terminal. Insulation grease can form a moisture-resistant seal and protect the terminals from corrosion.
Cleaning
Please clean the battery at regular intervals following the steps below:
- Disconnect the battery from the system.
- Clear the leaves and debris from the battery.
- Clean the battery with a soft, lint-free cloth. The cloth can be dampened with water or mild soap and water if the battery is extremely dirty.
- Dry the battery with a soft, lint-free cloth.
- Keep the area around the battery clean.
- Reconnect the battery to the system.
Checking Voltage
Please check the battery voltage periodically to assess battery health. If the battery is unable to be activated with a charge/discharge current greater than 1A or the battery is activated with a resting voltage below 10V, the battery may have been severely overdischarged due to self-discharge or parasitic loads. Please stop using the battery until the fault can be corrected and the battery can be charged.
Storage
Please follow the tips below to ensure that the battery emerges from storage in a good condition:
- Charge the battery to 30% to 50% SOC.
- Disconnect the battery from the system.
- Store the battery in a well-ventilated, dry, clean area with temperatures between -13°F (-25°C) and 149°F (65°C).
- Do not expose the battery to direct sunlight, moisture, or precipitation.
- Handle the battery carefully to avoid sharp impacts or extreme pressure on the battery housing.
- Charge the battery at least once every 3 to 6 months to prevent it from overdischarge.
- Fully charge the battery when it is taken out of storage.
Important Safety Instructions
The manufacturer accepts no liability for any damage caused by:
- Force majeure including fire, typhoon, flood, earthquake, war, and terrorism.
- Intentional or accidental misuse, abuse, neglect or improper maintenance, and use under abnormal conditions.
- Improper installation, improper operation, and malfunction of a peripheral device.
- Contamination with hazardous substances or radiation.
- Alterations to the product without express written consent from the manufacturer.
General
- Wear proper protective equipment and use insulated tools during installation and operation. Do not wear jewelry or other metal objects when working on or around the battery.
- Keep the battery out of the reach of children.
- Do not dispose of the battery as household waste. Comply with local, state, and federal laws and regulations and use recycling channels as required.
- In case of fire, put out the fire with a FM-200 or CO2 fire extinguisher.
- Do not expose the battery to flammable or harsh chemicals or vapors.
- Clean the battery regularly.
- It is recommended that all cables should not exceed 10 meters because excessively long cables result in a voltage drop.
- The cable specifications listed in the quick guide account for critical, less than 3% voltage drop and may not account for all configurations.
- Do not expose the battery to strong electrostatic fields, strong magnetic fields, or radiation.
Battery Safety
- Please keep the battery away from water, heat sources, sparks, and hazardous chemicals.
- Do not puncture, drop, crush, burn, penetrate, shake, strike, or step on the battery.
- Do not open, dismantle, repair, tamper with, or modify the battery.
- Do not touch any terminals or connectors.
- Please make sure any battery charger or charge controller has been disconnected before working on the battery.
- Do not connect or disconnect terminals from the battery without first disconnecting loads.
- Do not place tools on top of the battery.
- Please use suitable handling equipment for safe transportation of the battery.
- Do not insert foreign objects into the positive and negative terminals of the battery.
Renogy Support
To discuss inaccuracies or omissions in this quick guide or user manual, visit or contact us at:
For technical questions about your product in the U.S., contact the Renogy technical support team through:
- renogy.com/contact-us
- 1(909)2877111
For technical support outside the U.S., visit the local website below:
- Canada
- United Kingdom
- Australia
- South Korea
- China
- Japan
- Germany
- Other Europe
FCC Statement
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
- This device may not cause harmful interference, and
- This device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Orient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
FCC Radiation Exposure Statement
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body.
More Information
Renogy Empowered
- Renogy aims to empower people around the world through education and distribution of DIY-friendly renewable energy solutions.
- We intend to be a driving force for sustainable living and energy independence
- In support of this effort, our range of solar products makes it possible for you to minimize your carbon footprint by reducing the need for grid power.
EmpoweredLive Sustainably with Renogy
Did you know? In a given month, a 1 kW solar energy system will…
- Save 170 pounds of coal from being burned
- Save 300 pounds of CO2 from being released into the atmosphere
- Save 105 gallons of water from being consumed
Renogy Power PLUSRenogy
Renogy Power Plus allows you to stay in the loop with upcoming solar energy innovations, share your experiences with your solar energy journey, and connect with like-minded people who are changing the world in the Renogy Power Plus community.
- Youtube: @Renogy Solar
- Insta: @renogyofficial
- FB: @Renogy
Renogy reserves the right to change the contents of this manual without notice.
References
- Solar Power Kits & Equipment for Sale | Renogy Australia
- Renogy® Canada solar off-grid items, Canadian solar panels
- Renogy bietet alle Produkte für netzunabhängige Solarsysteme anRenogy DE
- Renogy Solar Korea
- Renogy® Official- offer all off grid solar system products
- Contact Us | Renogy Solar Panels & Complete Solar Kits
- Downloads
- Top off-grid solar kits, lithium batteries supplies | Renogy UK
- RENOGY如果新能源 | 让每个人拥有独立清洁的能源
- Renogy® Official- offer all off grid solar system products
- Contact Us | Renogy Solar Panels & Complete Solar Kits
- Downloads
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>